{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T14:44:34Z","timestamp":1768315474994,"version":"3.49.0"},"reference-count":41,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To investigate the correlations between the biomechanical indices determined in Scheimpflug-based corneal biomechanical assessments and the severity of keratoconus (KC) based on corneal tomographic assessments in patients with different stages of KC.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Fifty-three patients who presented with clinical KC in 1 eye and KC suspect in the fellow eye were included. Corneal tomographic and biomechanical assessments were performed using the Pentacam HR and Corvis ST (Oculus Optikger\u00e4te GmbH, Wetzlar, Germany). Correlations between the tomographic indices and biomechanical indices were assessed, including the anterior radius of curvature (ARC) and posterior radius of curvature (PRC) at a 3.0-mm optical zone and the thinnest pachymetry (Tmin), deformation amplitude ratio max 2 mm (DAR2mm), integrated radius, stiffness parameter at the first applanation, and linear Corvis Biomechanical Index (beta).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>DAR2mm correlated negatively with ARC (R = \u22120.722), PRC (R = \u22120.677), and Tmin (R= \u22120.650) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001 for all). Integrated radius correlated negatively with ARC (R = \u22120.700), PRC (R = \u22120.668), and Tmin (R= \u22120.648) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001 for all). Stiffness parameter at the first applanation correlated positively with ARC (R = 0.622), PRC (R = 0.601), and Tmin (R = 0.703) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001 for all). The Corvis Biomechanical Index beta correlated negatively with ARC (R = \u22120.754), PRC (R = \u22120.755), and Tmin (R= \u22120.765) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001 for all).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Corneal biomechanical indices correlated with corneal tomographic parameters in patients with KC. These findings support the possibility of developing biomechanical-based staging classification for KC in combination with topographic or tomographic indices.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ico.0000000000002129","type":"journal-article","created":{"date-parts":[[2019,9,2]],"date-time":"2019-09-02T04:58:16Z","timestamp":1567400296000},"page":"215-221","source":"Crossref","is-referenced-by-count":39,"title":["Correlation Between Corneal Biomechanical Indices and the Severity of Keratoconus"],"prefix":"10.1097","volume":"39","author":[{"given":"Shizuka","family":"Koh","sequence":"first","affiliation":[{"name":"Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan;"},{"name":"Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryota","family":"Inoue","sequence":"additional","affiliation":[{"name":"Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan;"},{"name":"SEED CO., LTD., Tokyo, Japan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Renato","family":"Ambr\u00f3sio","sequence":"additional","affiliation":[{"name":"Instituto de Olhos Renato Ambr\u00f3sio\/Visare Personal Laser, and Department of Ophthalmology, the Federal University of the State of Rio de Janeiro (UNIRIO) Rio de Janeiro, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoyuki","family":"Maeda","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsuya","family":"Miki","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kohji","family":"Nishida","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2019,8,29]]},"reference":[{"key":"R1-20230912","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/0039-6257(84)90094-8","article-title":"Keratoconus and relate noninflammatory corneal thinning disorders","volume":"28","author":"Krachmer","year":"1984","journal-title":"Surv Ophthalmol."},{"key":"R2-20230912","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","article-title":"Keratoconus","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Surv Ophthalmol."},{"key":"R3-20230912","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/S0886-3350(98)80284-8","article-title":"Live-epikeratophakia for keratoconus","volume":"24","author":"Krumeich","year":"1998","journal-title":"J Cataract Refract Surg."},{"key":"R4-20230912","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1097\/01.ico.0000226359.26678.d1","article-title":"A new method for grading the severity of keratoconus: the Keratoconus Severity Score (KSS)","volume":"25","author":"McMahon","year":"2006","journal-title":"Cornea."},{"key":"R5-20230912","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1097\/ICO.0000000000000408","article-title":"Global consensus on keratoconus and ectatic diseases","volume":"34","author":"Gomes","year":"2015","journal-title":"Cornea."},{"key":"R6-20230912","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.jcrs.2018.12.015","article-title":"Assessment of corneal biomechanical parameters in healthy and keratoconic eyes using dynamic bidirectional applanation device and dynamic Scheimpflug analyzer","volume":"45","author":"Herber","year":"2019","journal-title":"J Cataract Refract Surg."},{"key":"R7-20230912","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/j.ajo.2015.01.014","article-title":"Staging of keratoconus indices regarding tomography, topography, and biomechanical measurements","volume":"159","author":"Goebels","year":"2015","journal-title":"Am J Ophthalmol."},{"key":"R8-20230912","doi-asserted-by":"crossref","first-page":"219","DOI":"10.3928\/1081-597X-19930501-13","article-title":"Nomenclature for keratoconus suspects","volume":"9","year":"1993","journal-title":"Refract Corneal Surg."},{"key":"R9-20230912","doi-asserted-by":"crossref","first-page":"383","DOI":"10.3928\/1081597X-20190417-01","article-title":"Detection of subclinical corneal ectasia using corneal tomographic and biomechanical assessments","volume":"35","author":"Koh","year":"2019","journal-title":"J Refract Surg."},{"key":"R10-20230912","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s40662-016-0038-6","article-title":"Assessing progression of keratoconus: novel tomographic determinants","volume":"3","author":"Duncan","year":"2016","journal-title":"Eye Vis (Lond)."},{"key":"R11-20230912","doi-asserted-by":"crossref","first-page":"85","DOI":"10.5005\/jp-journals-10025-1105","article-title":"A new tomographic method of staging\/classifying keratoconus: the ABCD grading system","volume":"4","author":"Belin","year":"2015","journal-title":"Int J Keratoconus Ectatic Dis."},{"key":"R12-20230912","doi-asserted-by":"crossref","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","article-title":"Detection of keratoconus with a new biomechanical index","volume":"32","author":"Vinciguerra","year":"2016","journal-title":"J Refract Surg."},{"key":"R13-20230912","doi-asserted-by":"crossref","first-page":"1948","DOI":"10.1167\/iovs.04-1253","article-title":"Changes in collagen orientation and distribution in keratoconus corneas","volume":"46","author":"Meek","year":"2005","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R14-20230912","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1016\/j.jcrs.2014.04.013","article-title":"Biomechanics of corneal ectasia and biomechanical treatments","volume":"40","author":"Roberts","year":"2014","journal-title":"J Cataract Refract Surg."},{"key":"R15-20230912","doi-asserted-by":"crossref","first-page":"4490","DOI":"10.1167\/iovs.14-14450","article-title":"Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy","volume":"55","author":"Scarcelli","year":"2014","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R16-20230912","doi-asserted-by":"crossref","first-page":"840","DOI":"10.3928\/1081597X-20170922-02","article-title":"In vivo early corneal biomechanical changes after corneal cross-linking in patients with progressive keratoconus","volume":"33","author":"Vinciguerra","year":"2017","journal-title":"J Refract Surg."},{"key":"R17-20230912","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1136\/bjophthalmol-2017-311627","article-title":"Biomechanical assessment of healthy and keratoconic corneas (with\/without crosslinking) using dynamic ultrahigh-speed Scheimpflug technology and the relevance of the parameter (A1L-A2L)","volume":"103","author":"Fuchsluger","year":"2019","journal-title":"Br J Ophthalmol."},{"key":"R18-20230912","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1097\/ICO.0000000000001639","article-title":"Diagnostic ability of corneal shape and biomechanical parameters for detecting frank keratoconus","volume":"37","author":"Sedaghat","year":"2018","journal-title":"Cornea."},{"key":"R19-20230912","doi-asserted-by":"crossref","first-page":"399","DOI":"10.3928\/1081597X-20170213-01","article-title":"Biomechanical characterization of subclinical keratoconus without topographic or tomographic abnormalities","volume":"33","author":"Vinciguerra","year":"2017","journal-title":"J Refract Surg."},{"key":"R20-20230912","first-page":"2749","article-title":"Automated keratoconus screening with corneal topography analysis","volume":"35","author":"Maeda","year":"1994","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R21-20230912","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1001\/archopht.1995.01100070044023","article-title":"Comparison of methods for detecting keratoconus using videokeratography","volume":"113","author":"Maeda","year":"1995","journal-title":"Arch Ophthalmol."},{"key":"R22-20230912","first-page":"2290","article-title":"Current keratoconus detection methods compared with a neural network approach","volume":"38","author":"Smolek","year":"1997","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R23-20230912","doi-asserted-by":"crossref","first-page":"e258","DOI":"10.1111\/aos.12056","article-title":"Biomechanical diagnosis of keratoconus: evaluation of the keratoconus match index and the keratoconus match probability","volume":"91","author":"Labiris","year":"2013","journal-title":"Acta Ophthalmol."},{"key":"R24-20230912","doi-asserted-by":"crossref","first-page":"3651","DOI":"10.1167\/iovs.13-13715","article-title":"Biomechanical responses of healthy and keratoconic corneas measured using a noncontact scheimpflug-based tonometer","volume":"55","author":"Ali","year":"2014","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R25-20230912","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1097\/OPX.0b013e318279eb87","article-title":"Corneal deformation measurement using Scheimpflug noncontact tonometry","volume":"90","author":"Hon","year":"2013","journal-title":"Optom Vis Sci."},{"key":"R26-20230912","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2014\/147516","article-title":"Corneal biomechanical assessment using corneal visualization scheimpflug technology in keratoconic and normal eyes","volume":"2014","author":"Tian","year":"2014","journal-title":"J Ophthalmol."},{"key":"R27-20230912","doi-asserted-by":"crossref","first-page":"2885","DOI":"10.1167\/iovs.12-11563","article-title":"An ultra-high-speed Scheimpflug camera for evaluation of corneal deformation response and its impact on IOP measurement","volume":"54","author":"Leung","year":"2013","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R28-20230912","doi-asserted-by":"crossref","first-page":"408","DOI":"10.3928\/1081597X-20140513-02","article-title":"Dynamic Scheimpflug-based assessment of keratoconus and the effects of corneal cross-linking","volume":"30","author":"Bak-Nielsen","year":"2014","journal-title":"J Refract Surg."},{"key":"R29-20230912","doi-asserted-by":"crossref","first-page":"773","DOI":"10.3928\/1081597X-20170807-02","article-title":"Keratoconus screening with dynamic biomechanical in vivo scheimpflug analyses: a proof-of-concept study","volume":"33","author":"Steinberg","year":"2017","journal-title":"J Refract Surg."},{"key":"R30-20230912","doi-asserted-by":"crossref","first-page":"434","DOI":"10.3928\/1081597X-20170426-02","article-title":"Integration of Scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection","volume":"33","author":"Ambr\u00f3sio","year":"2017","journal-title":"J Refract Surg."},{"key":"R31-20230912","doi-asserted-by":"crossref","first-page":"840","DOI":"10.3928\/1081597X-20181012-01","article-title":"Tomographic and biomechanical scheimpflug imaging for keratoconus characterization: a validation of current indices","volume":"34","author":"Steinberg","year":"2018","journal-title":"J Refract Surg."},{"key":"R32-20230912","doi-asserted-by":"crossref","first-page":"247","DOI":"10.3928\/1081597X-20190226-01","article-title":"Biomechanical analysis of subclinical keratoconus with normal topographic, topometric, and tomographic findings","volume":"35","author":"Koc","year":"2019","journal-title":"J Refract Surg."},{"key":"R33-20230912","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.ajo.2018.08.054","article-title":"Enhanced ectasia detection using corneal tomography and biomechanics","volume":"197","author":"Ferreira-Mendes","year":"2019","journal-title":"Am J Ophthalmol."},{"key":"R34-20230912","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/j.jcrs.2018.10.030","article-title":"Accuracy of Scheimpflug-derived corneal biomechanical and tomographic indices for detecting subclinical and mild keratectasia in a South Asian population","volume":"45","author":"Kataria","year":"2019","journal-title":"J Cataract Refract Surg."},{"key":"R35-20230912","doi-asserted-by":"crossref","first-page":"213","DOI":"10.3928\/1081597X-20180103-01","article-title":"Should the Corvis biomechanical index (CBI) include corneal thickness parameters?","volume":"34","author":"Vinciguerra","year":"2018","journal-title":"J Refract Surg."},{"key":"R36-20230912","doi-asserted-by":"crossref","first-page":"849","DOI":"10.3928\/1081597X-20181012-02","article-title":"Long-term evaluation of corneal biomechanical properties after corneal cross-linking for keratoconus: a 4-year longitudinal study","volume":"34","author":"Sedaghat","year":"2018","journal-title":"J Refract Surg."},{"key":"R37-20230912","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1097\/ICO.0000000000001890","article-title":"Long-term chronological changes in very asymmetric keratoconus","volume":"38","author":"Koh","year":"2019","journal-title":"Cornea."},{"key":"R38-20230912","doi-asserted-by":"crossref","first-page":"1","DOI":"10.5005\/jp-journals-10025-1113","article-title":"Corneal deformation response with dynamic ultra-high-speed scheimpflug imaging for detecting ectatic corneas","volume":"5","author":"Salom\u00e3o","year":"2016","journal-title":"Int J Keratoconus Ectatic Corneal Dis."},{"key":"R39-20230912","doi-asserted-by":"crossref","first-page":"550","DOI":"10.3928\/1081597X-20160524-01","article-title":"Influence of pachymetry and intraocular pressure on dynamic corneal response parameters in healthy patients","volume":"32","author":"Vinciguerra","year":"2016","journal-title":"J Refract Surg."},{"key":"R40-20230912","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1097\/ICO.0000000000000293","article-title":"Repeatability, reproducibility, and age dependency of dynamic Scheimpflug-based pneumotonometer and its correlation with a dynamic bidirectional pneumotonometry device","volume":"34","author":"Bak-Nielsen","year":"2015","journal-title":"Cornea."},{"key":"R41-20230912","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1590\/S0004-27492013000400008","article-title":"Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera","volume":"76","author":"Valbon","year":"2013","journal-title":"Arq Bras Oftalmol."}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000002129","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T19:28:13Z","timestamp":1694546893000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000002129"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,29]]},"references-count":41,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0000000000002129","relation":{},"ISSN":["0277-3740"],"issn-type":[{"value":"0277-3740","type":"print"}],"subject":[],"published":{"date-parts":[[2019,8,29]]}}}