{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T04:36:30Z","timestamp":1790742990642,"version":"4.1.0"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To investigate the inflammatory response of the ocular surface with different soft contact lens (CL) replacement frequencies and materials.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Twenty soft CL wearers were required to wear 3 lens types: reusable Acuvue 2 (A2), reusable Acuvue Oasys (AO), and daily disposable Acuvue Oasys (AODD), for 1 week in random sequence in 1 eye with the nonlens-wearing eye acting as a control. Three methods were used to assess the subclinical response: tear cytokine evaluation, in vivo confocal microscopy (IVCM), and impression cytology.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Of 13 cytokines investigated, differences were observed only for IL-12p70, which was present in greater concentrations for A2 (interocular difference 8.8 pg\/mL, 95% confidence interval 5.5\u201312.1) and AO (8.9 [5.7\u201312.1]) compared with AODD (3.7 [0.6\u20136.8]). For IVCM, corneal presumed dendritic cell density was lower for AODD (interocular difference 1.9 [\u22120.1 to 3.9] cells\/mm<jats:sup>2<\/jats:sup>) than for both A2 (9.3 [7.2\u201311.4]) and AO (10.6 [8.6\u201312.6]). This trend was the same for the other 5 IVCM measures evaluated. The proportion of CD45<jats:sup>+<\/jats:sup> cells in the bulbar conjunctiva was lower for AODD (0.6 [\u22120.3 to 1.5]%) compared with A2 (4.6 [3.7\u20135.6]) and AO (4.8 [3.9\u20135.8]). Similar findings were observed for cells in the upper lid margin.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>This work has demonstrated for the first time that daily disposable CL wear produces a minimal subclinical inflammatory response compared with no lens wear over 1 week. By contrast, this inflammatory response is upregulated with reusable lenses but appears to be similar between hydrogel and silicone hydrogel materials over this short time frame.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ico.0000000000002192","type":"journal-article","created":{"date-parts":[[2019,11,13]],"date-time":"2019-11-13T19:44:57Z","timestamp":1573674297000},"page":"146-154","source":"Crossref","is-referenced-by-count":32,"title":["Subclinical Inflammation of the Ocular Surface in Soft Contact Lens Wear"],"prefix":"10.1097","volume":"39","author":[{"given":"Noor Haziq","family":"Saliman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip B.","family":"Morgan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew S.","family":"MacDonald","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carole","family":"Maldonado-Codina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,11,7]]},"reference":[{"key":"R1-20230912","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1016\/j.ophtha.2008.04.002","article-title":"The incidence of contact lens-related microbial keratitis in Australia","volume":"115","author":"Stapleton","year":"2008","journal-title":"Ophthalmology"},{"key":"R2-20230912","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1111\/cxo.12598","article-title":"Epidemiology of contact lens-induced infiltrates: an updated review","volume":"100","author":"Steele","year":"2017","journal-title":"Clin Exp Optom."},{"key":"R3-20230912","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1111\/j.1444-0938.2006.00069.x","article-title":"Rethinking contact lens associated keratitis","volume":"89","author":"Efron","year":"2006","journal-title":"Clin Exp Optom."},{"key":"R4-20230912","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/OPX.0b013e3180421c47","article-title":"Risk of corneal inflammatory events with silicone hydrogel and low dk hydrogel extended contact lens wear: a meta-analysis","volume":"84","author":"Szczotka-Flynn","year":"2007","journal-title":"Optom Vis Sci."},{"key":"R5-20230912","doi-asserted-by":"crossref","first-page":"6690","DOI":"10.1167\/iovs.10-7018","article-title":"Age and other risk factors for corneal infiltrative and inflammatory events in young soft contact lens wearers from the Contact Lens Assessment in Youth (CLAY) study","volume":"52","author":"Chalmers","year":"2011","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R6-20230912","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/OPX.0b013e318240c7ff","article-title":"Multicenter case-control study of the role of lens materials and care products on the development of corneal infiltrates","volume":"89","author":"Chalmers","year":"2012","journal-title":"Optom Vis Sci."},{"key":"R7-20230912","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1097\/OPX.0000000000001129","article-title":"Preinflammatory signs in established reusable and disposable contact lens wearers","volume":"94","author":"Chao","year":"2017","journal-title":"Optom Vis Sci."},{"key":"R8-20230912","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1111\/cxo.12399","article-title":"Longitudinal changes in Langerhans cell density of the cornea and conjunctiva in contact lens-induced dry eye","volume":"100","author":"Alzahrani","year":"2017","journal-title":"Clin Exp Optom."},{"key":"R9-20230912","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1097\/OPX.0000000000001224","article-title":"The effect of contact lens wear on the cellular morphology of the lid wiper area","volume":"95","author":"Alghamdi","year":"2018","journal-title":"Optom Vis Sci."},{"key":"R10-20230912","first-page":"300","article-title":"Dual-model automatic detection of nerve-fibres in corneal confocal microscopy images","volume":"13","author":"Dabbah","year":"2010","journal-title":"Med Image Comput Comput Assist Interv."},{"key":"R11-20230912","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1016\/j.media.2011.05.016","article-title":"Automatic analysis of diabetic peripheral neuropathy using multi-scale quantitative morphology of nerve fibres in corneal confocal microscopy imaging","volume":"15","author":"Dabbah","year":"2011","journal-title":"Med Image Anal."},{"key":"R12-20230912","first-page":"1611","article-title":"Evaluation of conjunctival inflammatory status by confocal scanning laser microscopy and conjunctival brush cytology in patients with atopic keratoconjunctivitis (AKC)","volume":"15","author":"Wakamatsu","year":"2009","journal-title":"Mol Vis."},{"key":"R13-20230912","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1016\/j.jclinepi.2006.02.007","article-title":"ANCOVA versus change from baseline had more power in randomized studies and more bias in nonrandomized studies","volume":"59","author":"Van Breukelen","year":"2006","journal-title":"J Clin Epidemiol."},{"key":"R14-20230912","first-page":"441","article-title":"Comparative analysis of tear film levels of inflammatory mediators in contact lens users","volume":"41","author":"Y\u00fcksel Elgin","year":"2016","journal-title":"Curr Eye Res."},{"key":"R15-20230912","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.clae.2010.12.001","article-title":"The effects of 2 week senofilcon-A silicone hydrogel contact lens daily wear on tear functions and ocular surface health status","volume":"34","author":"Dogru","year":"2011","journal-title":"Cont Lens Anterior Eye."},{"key":"R16-20230912","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1097\/OPX.0000000000000784","article-title":"Corneal sensitivity and inflammatory biomarkers in contact lens discomfort","volume":"93","author":"L\u00f3pez-de la Rosa","year":"2016","journal-title":"Optom Vis Sci."},{"key":"R17-20230912","first-page":"293","article-title":"Cytokine changes in tears and relationship to contact lens discomfort","volume":"21","author":"Willcox","year":"2015","journal-title":"Mol Vis."},{"key":"R18-20230912","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1097\/ICL.0b013e3181b3e87f","article-title":"Elevated nerve growth factor in dry eye associated with established contact lens wear","volume":"35","author":"Liu","year":"2009","journal-title":"Eye Contact Lens."},{"key":"R19-20230912","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/ICO.0b013e31802e3b55","article-title":"In vivo confocal microscopic evaluation of langerhans cell density and distribution in the corneal epithelium of healthy volunteers and contact lens wearers","volume":"26","author":"Zhivov","year":"2007","journal-title":"Cornea"},{"key":"R20-20230912","doi-asserted-by":"crossref","first-page":"511","DOI":"10.2147\/OPTH.S28083","article-title":"Dendritic immune cell densities in the central cornea associated with soft contact lens types and lens care solution types: a pilot study","volume":"6","author":"Sindt","year":"2012","journal-title":"Clin Ophthalmol."},{"key":"R21-20230912","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.clae.2017.08.001","article-title":"Corneal confocal microscopy and dry eye findings in contact lens discomfort patients","volume":"41","author":"Dogan","year":"2018","journal-title":"Cont Lens Anterior Eye."},{"key":"R22-20230912","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1080\/02713683.2017.1420804","article-title":"Are contact lens discomfort or soft contact lens material properties associated with alterations in the corneal sub-basal nerve plexus?","volume":"43","author":"L\u00f3pez-De La Rosa","year":"2018","journal-title":"Curr Eye Res."},{"key":"R23-20230912","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1097\/OPX.0000000000000865","article-title":"Inflammatory cell upregulation of the lid wiper in contact lens dry eye","volume":"93","author":"Alzahrani","year":"2016","journal-title":"Optom Vis Sci."},{"key":"R24-20230912","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/ICO.0b013e3181acf82a","article-title":"Confocal microscopy of the bulbar conjunctiva in contact lens wear","volume":"29","author":"Efron","year":"2010","journal-title":"Cornea"},{"key":"R25-20230912","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.clae.2016.02.008","article-title":"Changes in corneal Langerhans cell density during the first few hours of contact lens wear","volume":"39","author":"Alzahrani","year":"2016","journal-title":"Cont Lens Anterior Eye."},{"key":"R26-20230912","doi-asserted-by":"crossref","first-page":"e547","DOI":"10.1111\/j.1755-3768.2012.02482.x","article-title":"Assessing the human lid margin epithelium using impression cytology","volume":"90","author":"Jalbert","year":"2012","journal-title":"Acta Ophthalmol."},{"key":"R27-20230912","first-page":"109","article-title":"Impression cytology in different types of contact lens users","volume":"4","author":"Iskeleli","year":"2015","journal-title":"Med Hypothesis Discov Innov Ophthalmol."},{"key":"R28-20230912","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1097\/00003226-200111000-00009","article-title":"Ocular surface changes induced by contact lens wear","volume":"20","author":"Pisella","year":"2001","journal-title":"Cornea"},{"key":"R29-20230912","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1111\/aos.12103","article-title":"Ocular surface assessment in soft contact lens wearers; the contribution of tear osmolarity among other tests","volume":"92","author":"Muselier-Mathieu","year":"2014","journal-title":"Acta Ophthalmol."},{"key":"R30-20230912","doi-asserted-by":"crossref","first-page":"1517","DOI":"10.1007\/s11357-011-9316-3","article-title":"The dominant human conjunctival epithelial CD8alphabeta+ T cell population is maintained with age but the number of CD4+ T cells increases","volume":"34","author":"Williams","year":"2012","journal-title":"Age (Dordr)"},{"key":"R31-20230912","doi-asserted-by":"crossref","first-page":"5457","DOI":"10.1167\/iovs.16-19247","article-title":"Conjunctival neutrophils predict progressive scarring in ocular mucous membrane pemphigoid","volume":"57","author":"Williams","year":"2016","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R32-20230912","first-page":"71","article-title":"Inactivation and denaturation of some proteins by enzyme system: myeloperoxidase, chloride and hydrogen peroxide","volume":"31","author":"Drozdz","year":"1993","journal-title":"Folia Histochem Cytobiol."},{"key":"R33-20230912","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/ICL.0b013e31823fdb2a","article-title":"Preservation of human tear protein structure and function by a novel contact lens multipurpose solution containing protein-stabilizing agents","volume":"38","author":"Wright","year":"2012","journal-title":"Eye Contact Lens."},{"key":"R34-20230912","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1167\/iovs.13-12881","article-title":"Evidence of lipid degradation during overnight contact lens wear: gas chromatography mass spectrometry as the diagnostic tool","volume":"55","author":"Panaser","year":"2014","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R35-20230912","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1097\/OPX.0b013e318288e10c","article-title":"Effect of lens care systems on the clinical performance of a contact lens","volume":"90","author":"Lazon de la Jara","year":"2013","journal-title":"Optom Vis Sci."},{"key":"R36-20230912","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1097\/OPX.0000000000000008","article-title":"Combined effect of comfort and adverse events on contact lens performance","volume":"90","author":"Diec","year":"2013","journal-title":"Optom Vis Sci."},{"key":"R37-20230912","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1167\/iovs.14-15582","article-title":"Rates of adverse events with hydrogel and silicone hydrogel daily disposable lenses in a large postmarket surveillance registry: the TEMPO Registry","volume":"56","author":"Chalmers","year":"2015","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R38-20230912","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.ophtha.2008.09.053","article-title":"Risk factors for nonulcerative contact lens complications in an ophthalmic accident and emergency department: a case-control study","volume":"116","author":"Radford","year":"2009","journal-title":"Ophthalmology"},{"key":"R39-20230912","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/S1367-0484(98)80040-4","article-title":"Soft contact lens care systems and corneal staining in Hong Kong-Chinese","volume":"21","author":"Cho","year":"1998","journal-title":"Cont Lens Anterior Eye."},{"key":"R40-20230912","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1167\/iovs.15-18512","article-title":"Case-control pilot study of soft contact lens wearers with corneal infiltrative events and healthy controls","volume":"57","author":"Richdale","year":"2016","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R41-20230912","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1097\/OPX.0000000000000746","article-title":"Contact lens corneal inflammatory events in a university population","volume":"93","author":"Zimmerman","year":"2016","journal-title":"Optom Vis Sci."},{"key":"R42-20230912","doi-asserted-by":"crossref","first-page":"1616","DOI":"10.1001\/archophthalmol.2009.313","article-title":"Contact lens-related adverse events and the silicone hydrogel lenses and daily wear care system used","volume":"127","author":"Carnt","year":"2009","journal-title":"Arch Ophthalmol."},{"key":"R43-20230912","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1097\/OPX.0b013e31816bf5a3","article-title":"To the editor: risk of corneal inflammatory events with silicone hydrogel and low dk hydrogel extended contact lens wear: a meta-analysis","volume":"85","author":"Brennan","year":"2008","journal-title":"Optom Vis Sci."},{"key":"R44-20230912","first-page":"14","article-title":"Factors influencing bacterial adhesion to contact lenses","volume":"18","author":"Dutta","year":"2012","journal-title":"Mol Vis."},{"key":"R45-20230912","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1111\/cxo.12487","article-title":"Contact lens wear is intrinsically inflammatory","volume":"100","author":"Efron","year":"2017","journal-title":"Clin Exp Optom."}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000002192","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T19:28:18Z","timestamp":1694546898000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000002192"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,7]]},"references-count":45,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0000000000002192","relation":{},"ISSN":["0277-3740"],"issn-type":[{"value":"0277-3740","type":"print"}],"subject":[],"published":{"date-parts":[[2019,11,7]]}}}