{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T19:03:48Z","timestamp":1754161428831,"version":"3.41.2"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>The purpose of this study was to evaluate the efficacy and safety of implantation of a new continuous corneal ring in keratoconic corneas of an Iranian population.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This study was conducted on 95 contact lens\u2013intolerant keratoconic eyes with clear central corneas. A continuous corneal ring, annular intrastromal corneal inlay (AICI), was inserted using femtosecond laser in all cases. Patients were followed up for 1, 3, and 12 months postsurgery. Visual and subjective refractive outcomes were evaluated in each examination. Besides, keratometry and aberrometric values were recorded before and 12 months after surgery. Finally, vector analysis of refractive astigmatism was performed using the Alpins method.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The uncorrected and corrected distance visual acuities improved significantly 12 months after surgery from 0.91 \u00b1 0.39 to 0.38 \u00b1 0.22 (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0 0.001) and 0.33 \u00b1 0.21 to 0.13 \u00b1 0.11 logMAR (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001), respectively. Moreover, spherical and cylindrical refractive components reduced from \u22122.52 \u00b1 2.62 to \u22120.76 \u00b1 1.78 D (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001) and \u22124.14 \u00b1 1.64 to \u22121.91 \u00b1 1.18 D (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001), respectively. The mean anterior keratometry had a significant reduction 12 months after AICI insertion (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt; 0.001). Primary coma and spherical aberration values showed a significant increase (both, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05). Our results showed 100% safety (safety index: 1.8) and 45% efficacy (efficacy index: 1).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>AICI implantation seemed to be a safe and effective procedure for improving visual acuity and refractive outcomes in subjects with keratoconus.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ico.0000000000002807","type":"journal-article","created":{"date-parts":[[2021,7,16]],"date-time":"2021-07-16T00:01:47Z","timestamp":1626393707000},"page":"435-442","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Clinical Outcomes of a New Type of Continuous Intrastromal Corneal Ring for Treatment of Keratoconus"],"prefix":"10.1097","volume":"41","author":[{"given":"Mahmoud","family":"Jabbarvand","sequence":"first","affiliation":[{"name":"Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hooman","family":"Ahmadzadeh","sequence":"additional","affiliation":[{"name":"School of Medicine, Tehran University of Medical Sciences, Tehran, Iran;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mehdi","family":"Khodaparast","sequence":"additional","affiliation":[{"name":"Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alireza","family":"Jamali","sequence":"additional","affiliation":[{"name":"Rehabilitation Research Center, Department of Optometry, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamadreza","family":"Aghamirsalim","sequence":"additional","affiliation":[{"name":"Translational Ophthalmology Research Center, Tehran University of Medical Sciences, Tehran, Iran."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,7,14]]},"reference":[{"key":"R1-20250728","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","article-title":"Keratoconus","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Surv Ophthalmol."},{"key":"R2-20250728","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1097\/ICO.0b013e31823f8d3c","article-title":"Epidemiology of keratoconus in an Iranian population","volume":"31","author":"Ziaei","year":"2012","journal-title":"Cornea"},{"key":"R3-20250728","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/s40662-016-0033-y","article-title":"Corneal surgery in keratoconus: which type, which technique, which outcomes?","volume":"3","author":"Arnalich-Montiel","year":"2016","journal-title":"Eye Vis."},{"key":"R4-20250728","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/ICL.0b013e3180515299","article-title":"Changes in the anterior and posterior radii of the corneal curvature and anterior chamber depth by orthokeratology","volume":"34","author":"Tsukiyama","year":"2008","journal-title":"Eye Contact Lens"},{"key":"R5-20250728","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1097\/ICO.0000000000000289","article-title":"Histological and confocal changes in rabbit cornea produced by an intrastromal inlay made of hexafocon A","volume":"34","author":"Salamatrad","year":"2015","journal-title":"Cornea"},{"key":"R6-20250728","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1016\/j.ophtha.2010.12.012","article-title":"Clinical outcomes after complete ring implantation in corneal ectasia using the femtosecond technology: a pilot study","volume":"118","author":"Alio","year":"2011","journal-title":"Ophthalmology"},{"key":"R7-20250728","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/S0886-3350(98)80305-2","article-title":"Format for reporting refractive surgical data","volume":"24","author":"Koch","year":"1998","journal-title":"J Cataract Refract Surg."},{"key":"R8-20250728","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0886-3350(00)00798-7","article-title":"Astigmatism analysis by the Alpins method","volume":"27","author":"Alpins","year":"2001","journal-title":"J Cataract Refract Surg."},{"key":"R9-20250728","doi-asserted-by":"crossref","first-page":"406","DOI":"10.3928\/1081597X-20190625-01","article-title":"ASSORT Group analysis calculator: a benefit for the journal of refractive surgery and ISRS members","volume":"35","author":"Randleman","year":"2019","journal-title":"J Refract Surg."},{"key":"R10-20250728","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/00004397-196606010-00004","article-title":"Modification of refraction by means of intracorneal inclusions","volume":"6","author":"Barraquer","year":"1966","journal-title":"Int Ophthalmol Clin."},{"key":"R11-20250728","doi-asserted-by":"crossref","first-page":"227","DOI":"10.3928\/1081-597X-19871101-07","article-title":"The intrastromal corneal ring: two cases in rabbits","volume":"3","author":"Fleming","year":"1987","journal-title":"J Refract Surg."},{"key":"R12-20250728","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/00055735-199808000-00003","article-title":"Intrastromal corneal ring technology: results and indications","volume":"9","author":"Burris","year":"1998","journal-title":"Curr Opin Ophthalmol."},{"key":"R13-20250728","doi-asserted-by":"crossref","first-page":"20","DOI":"10.3928\/1081-597X-19960101-08","article-title":"Intrastromal corneal ring: 12-month sighted myopic eyes","volume":"12","author":"Nos\u00e9","year":"1996","journal-title":"J Refract Surg."},{"key":"R14-20250728","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1016\/S0161-6420(97)30183-3","article-title":"The intrastromal corneal ring segments: phase II results for the correction of myopia","volume":"104","author":"Schanzlin","year":"1997","journal-title":"Ophthalmology"},{"key":"R15-20250728","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1016\/S0886-3350(00)00451-X","article-title":"Correcting keratoconus with intracorneal rings","volume":"26","author":"Colin","year":"2000","journal-title":"J Cataract Refract Surg."},{"key":"R16-20250728","doi-asserted-by":"crossref","first-page":"1886","DOI":"10.1016\/j.jcrs.2007.06.055","article-title":"Intracorneal ring segment implantation for the management of keratoconus: safety and efficacy","volume":"33","author":"Zare","year":"2007","journal-title":"J Cataract Refract Surg."},{"key":"R17-20250728","doi-asserted-by":"crossref","first-page":"4415","DOI":"10.2147\/OPTH.S283387","article-title":"Asymmetric thickness intracorneal ring segments for keratoconus","volume":"14","author":"Baptista","year":"2020","journal-title":"Clin Ophthalmol."},{"key":"R18-20250728","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.jcrs.2007.10.011","article-title":"Corneal intrastromal implantation surgery for the treatment of moderate and high myopia","volume":"34","author":"Daxer","year":"2008","journal-title":"J Cataract Refract Surg."},{"key":"R19-20250728","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1016\/j.jcrs.2013.02.054","article-title":"Continuous intracorneal ring implantation for keratoconus using a femtosecond laser","volume":"39","author":"Jabbarvand","year":"2013","journal-title":"J Cataract Refract Surg."},{"key":"R20-20250728","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1016\/j.ajo.2007.12.022","article-title":"One-year results of intrastromal corneal ring segment implantation (KeraRing) using femtosecond laser in patients with keratoconus","volume":"145","author":"Coskunseven","year":"2008","journal-title":"Am J Ophthalmol."},{"key":"R21-20250728","doi-asserted-by":"crossref","first-page":"15","DOI":"10.5005\/jp-journals-10025-1071","article-title":"Corneal thickness after MyoRing implantation for keratoconus","volume":"3","author":"Daxer","year":"2014","journal-title":"Int J Keratoconus Ectatic Corneal Dis."},{"key":"R22-20250728","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.optom.2016.01.002","article-title":"Long-term results of MyoRing treatment of keratoconus","volume":"10","author":"Daxer","year":"2017","journal-title":"J Optom."},{"key":"R23-20250728","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1097\/01.ico.0000167883.63266.60","article-title":"Modified intracorneal ring segment implantations (INTACS) for the management of moderate to advanced keratoconus: efficacy and complications","volume":"25","author":"Kanellopoulos","year":"2006","journal-title":"Cornea"},{"key":"R24-20250728","doi-asserted-by":"crossref","first-page":"191","DOI":"10.3928\/1081597X-20190109-02","article-title":"Effectiveness of intrastromal corneal ring implantation in the treatment of adult patients with keratoconus: a systematic review","volume":"35","author":"Izquierdo","year":"2019","journal-title":"J Refract Surg."},{"key":"R25-20250728","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.ajo.2020.09.041","article-title":"Incidence and reasons for intrastromal corneal ring segment explantation","volume":"222","author":"D'Oria","year":"2021","journal-title":"Am J Ophthalmol."},{"key":"R26-20250728","doi-asserted-by":"crossref","first-page":"76","DOI":"10.5005\/jp-journals-10025-1104","article-title":"MyoRing treatment of keratoconus","volume":"4","author":"Daxer","year":"2015","journal-title":"Int J Keratoconus Ectatic Corneal Dis."},{"key":"R27-20250728","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1016\/j.ajo.2012.11.015","article-title":"Continuous corneal intrastromal ring implantation for treatment of keratoconus in an Iranian population","volume":"155","author":"Jabbarvand","year":"2013","journal-title":"Am J Ophthalmol."},{"key":"R28-20250728","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1007\/s10792-016-0385-2","article-title":"Clinical evaluation of two types of intracorneal ring segments (ICRS) for keratoconus","volume":"37","author":"Al-Tuwairqi","year":"2017","journal-title":"Int Ophthalmol."},{"key":"R29-20250728","doi-asserted-by":"crossref","first-page":"473","DOI":"10.2147\/OPTH.S241755","article-title":"Vector analysis of astigmatism in keratoconic eyes after combined intrastromal corneal ring segments implantation and collagen cross-linking","volume":"14","author":"Abozaid","year":"2020","journal-title":"Clin Ophthalmol."},{"key":"R30-20250728","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1016\/j.jcrs.2006.02.012","article-title":"Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction","volume":"32","author":"Ali\u00f3","year":"2006","journal-title":"J Cataract Refract Surg."},{"key":"R31-20250728","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1016\/j.jcrs.2008.05.028","article-title":"Intacs implantation using a femtosecond laser for management of keratoconus: comparison of 306 cases in different stages","volume":"34","author":"Ertan","year":"2008","journal-title":"J Cataract Refract Surg."},{"key":"R32-20250728","doi-asserted-by":"crossref","first-page":"S69","DOI":"10.5301\/ejo.5000063","article-title":"Vectorial astigmatic changes after corneal collagen crosslinking in keratoconic corneas previously treated with intracorneal ring segments: a preliminary study","volume":"22","author":"Pi\u00f1ero","year":"2012","journal-title":"Eur J Ophthalmol."},{"key":"R33-20250728","first-page":"2244","article-title":"The three-dimensional organization of collagen fibrils in the human cornea and sclera","volume":"32","author":"Komai","year":"1991","journal-title":"Investig Ophthalmol Vis Sci."},{"key":"R34-20250728","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1097\/ICO.0000000000000026","article-title":"Implantation of a complete intrastromal corneal ring at 2 different stromal depths in keratoconus","volume":"33","author":"Jabbarvand","year":"2014","journal-title":"Cornea"},{"key":"R35-20250728","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1097\/ICL.0000000000000595","article-title":"Anatomical and visual effects of the MyoRing implantation measured by the ABCD keratoconus grading system","volume":"46","author":"Sedaghat","year":"2020","journal-title":"Eye Contact Lens"},{"key":"R36-20250728","doi-asserted-by":"crossref","first-page":"46","DOI":"10.3928\/1081-597X-19910101-14","article-title":"Effects of intrastromal corneal ring size and thickness on corneal flattening in human eyes","volume":"7","author":"Burris","year":"1991","journal-title":"Refract Corneal Surg."},{"key":"R37-20250728","doi-asserted-by":"crossref","first-page":"1493","DOI":"10.1097\/ICO.0000000000000591","article-title":"Biomechanics of corneal ring implants","volume":"34","author":"Daxer","year":"2015","journal-title":"Cornea"},{"key":"R38-20250728","doi-asserted-by":"crossref","first-page":"217","DOI":"10.3928\/1081597X-20100224-08","article-title":"Adjustable intracorneal ring in a lamellar pocket for keratoconus","volume":"26","author":"Daxer","year":"2010","journal-title":"J Refract Surg."},{"key":"R39-20250728","doi-asserted-by":"crossref","first-page":"910","DOI":"10.12816\/0038191","article-title":"Comparative study between Myoring and Ferrara Ring intracorneal implantation using femtosecond laser for treatment of keratoconus","volume":"68","author":"Sammour","year":"2017","journal-title":"Egypt J Hosp Med."},{"key":"R40-20250728","doi-asserted-by":"crossref","first-page":"121","DOI":"10.2147\/OPTH.S73855","article-title":"Femtosecond laser-assisted implantation of complete versus incomplete rings for keratoconus treatment","volume":"9","author":"Hosny","year":"2015","journal-title":"Clin Ophthalmol."},{"key":"R41-20250728","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.jcrs.2017.12.020","article-title":"Comparative study of 3 intracorneal implant types to manage central keratoconus","volume":"44","author":"Yousif","year":"2018","journal-title":"J Cataract Refract Surg."},{"key":"R42-20250728","doi-asserted-by":"crossref","first-page":"2929","DOI":"10.1007\/s10792-019-01121-9","article-title":"Efficacy of complete rings (MyoRing) in treatment of keratoconus: a systematic review and meta-analysis","volume":"39","author":"Janani","year":"2019","journal-title":"Int Ophthalmol."},{"key":"R43-20250728","doi-asserted-by":"crossref","first-page":"248","DOI":"10.3928\/1081-597X-19950701-08","article-title":"Model for deriving the optical performance of the myopic eye corrected with an intracorneal ring","volume":"11","author":"Patel","year":"1995","journal-title":"J Refract Surg."}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000002807","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,28]],"date-time":"2025-07-28T22:06:51Z","timestamp":1753740411000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000002807"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,14]]},"references-count":43,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0000000000002807","relation":{},"ISSN":["0277-3740"],"issn-type":[{"type":"print","value":"0277-3740"}],"subject":[],"published":{"date-parts":[[2021,7,14]]},"assertion":[{"value":"2021-01-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-05-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}