{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T02:10:28Z","timestamp":1792548628839,"version":"4.5.0"},"reference-count":39,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>The purpose of this study was to determine whether the Scheimpflug tomographically normal fellow eyes of keratoconus patients are also classified as normal using an ectasia screening algorithm based on anterior segment optical coherence tomography (AS-OCT).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This monocentric cross-sectional study included 22 very asymmetric ectasia patients with tomographically significant keratoconus in 1 eye and normal Scheimpflug tomography in the fellow eye. Twenty-two eyes of 22 healthy subjects served as a control group. We performed corneal tomography using Pentacam AXL (Oculus, Wetzlar, Germany) and used Belin\/Ambr\u00f3sio Enhanced Ectasia total deviation index as well as Belin ABCD keratoconus classification to identify Scheimpflug tomographically normal eyes. We also performed AS-OCT using Anterion (Heidelberg Engineering, Heidelberg, Germany) and analyzed for the presence of ectasia using the Screening Corneal Objective Risk of Ectasia (SCORE) algorithm, with positive values indicating ectasia suspect tomography.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The SCORE value was positive in 9.1% (n = 2) of the healthy eyes, in 45.5% (n = 10) of the Scheimpflug tomographically normal eyes of keratoconus patients and in all eyes (n = 22) with tomographically significant keratoconus. The Scheimpflug tomographically normal eyes of keratoconus patients had higher SCORE values compared with healthy controls (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). The median (interquartile range) SCORE value was \u22121.7 (1.3) in healthy controls, \u22120.5 (2.2) in Scheimpflug tomographically normal eyes of keratoconus patients, and 11.1 (11.0) in tomographically significant keratoconus eyes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The Scheimpflug tomographically normal fellow eyes of keratoconus patients had higher AS-OCT\u2013based SCORE values than healthy controls, with positive SCORE values found in 46% of the eyes, indicating early tomographic ectatic changes.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ico.0000000000003518","type":"journal-article","created":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T16:01:06Z","timestamp":1710345666000},"page":"812-819","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Ectasia Detection by Anterior Segment Optical Coherence Tomography in Scheimpflug Tomographically Normal Keratoconus Fellow Eyes"],"prefix":"10.1097","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5118-3423","authenticated-orcid":false,"given":"Tadas","family":"Naujokaitis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6315-8484","authenticated-orcid":false,"given":"Victor A.","family":"Augustin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyeck-Soo","family":"Son","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"K\u00f6ppe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bogdana","family":"Kovalchuk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd U.","family":"Auffarth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramin","family":"Khoramnia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,3,13]]},"reference":[{"key":"R1-20250723","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.ophtha.2022.11.027","article-title":"Incidence and prevalence of keratoconus based on Scheimpflug imaging","volume":"130","author":"Chan","year":"2023","journal-title":"Ophthalmology"},{"key":"R2-20250723","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.ophtha.2020.08.020","article-title":"Prevalence of keratoconus based on Scheimpflug imaging: the raine study","volume":"128","author":"Chan","year":"2021","journal-title":"Ophthalmology"},{"key":"R3-20250723","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1097\/j.jcrs.0000000000000669","article-title":"Prevalence and risk factors for keratoconus in a university-based population in Turkey","volume":"47","author":"\u00d6zalp","year":"2021","journal-title":"J Cataract Refract Surg."},{"key":"R4-20250723","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/ICO.0000000000002150","article-title":"The prevalence and risk factors for keratoconus: a systematic review and meta-analysis","volume":"39","author":"Hashemi","year":"2020","journal-title":"Cornea"},{"key":"R5-20250723","doi-asserted-by":"crossref","first-page":"400","DOI":"10.3928\/1081-597X-19891101-10","article-title":"Computer-assisted corneal topography in keratoconus","volume":"5","author":"Rabinowitz","year":"1989","journal-title":"Refract Corneal Surg."},{"key":"R6-20250723","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/S0161-6420(00)00159-7","article-title":"Changes in anterior and posterior corneal curvatures in keratoconus","volume":"107","author":"Tomidokoro","year":"2000","journal-title":"Ophthalmology"},{"key":"R7-20250723","doi-asserted-by":"crossref","first-page":"664","DOI":"10.3928\/1081597X-20180823-02","article-title":"Differences in posterior corneal features between normal corneas and subclinical keratoconus","volume":"34","author":"Golan","year":"2018","journal-title":"J Refract Surg."},{"issue":"Suppl 10","key":"R8-20250723","doi-asserted-by":"crossref","first-page":"S16","DOI":"10.1097\/ICO.0000000000000504","article-title":"Contemporary treatment paradigms in keratoconus","volume":"34","author":"McGhee","year":"2015","journal-title":"Cornea"},{"key":"R9-20250723","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.ophtha.2007.03.073","article-title":"Risk assessment for ectasia after corneal refractive surgery","volume":"115","author":"Randleman","year":"2008","journal-title":"Ophthalmology"},{"key":"R10-20250723","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.3390\/diagnostics11081466","article-title":"Current developments in corneal topography and tomography","volume":"11","author":"Kanclerz","year":"2021","journal-title":"Diagnostics (Basel)"},{"key":"R11-20250723","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1177\/11206721211063740","article-title":"Detecting subclinical keratoconus by biomechanical analysis in tomographically regular keratoconus fellow eyes","volume":"32","author":"Augustin","year":"2022","journal-title":"Eur J Ophthalmol."},{"key":"R12-20250723","doi-asserted-by":"crossref","first-page":"399","DOI":"10.3928\/1081597X-20170213-01","article-title":"Biomechanical characterization of subclinical keratoconus without topographic or tomographic abnormalities","volume":"33","author":"Vinciguerra","year":"2017","journal-title":"J Refract Surg."},{"key":"R13-20250723","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1016\/j.jcrs.2005.03.058","article-title":"Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry","volume":"31","author":"Barkana","year":"2005","journal-title":"J Cataract Refract Surg."},{"key":"R14-20250723","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1055\/s-0042-100626","article-title":"Keratoconus: the ABCD grading system","volume":"233","author":"Belin","year":"2016","journal-title":"Klin Monbl Augenheilkd"},{"key":"R15-20250723","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/ICO.0000000000002781","article-title":"Keratoconus: diagnosis and staging","volume":"41","author":"Belin","year":"2022","journal-title":"Cornea"},{"key":"R16-20250723","doi-asserted-by":"crossref","first-page":"92","DOI":"10.5005\/jp-journals-10025-1018","article-title":"Topometric and tomographic indices for the diagnosis of keratoconus","volume":"1","author":"Ramos","year":"2012","journal-title":"Int J Keratoconus Ectatic Corneal Dis."},{"key":"R17-20250723","doi-asserted-by":"crossref","first-page":"1","DOI":"10.5005\/jp-journals-10025-1069","article-title":"Independent population validation of the Belin\/Ambrosio enhanced ectasia display: implications for keratoconus studies and screening","volume":"3","author":"Villavicencio","year":"2014","journal-title":"Int J Keratoconus Ectatic Corneal Dis."},{"key":"R18-20250723","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1167\/tvst.9.9.14","article-title":"Intradevice repeatability and interdevice agreement of ocular biometric measurements: a comparison of two swept-source anterior segment OCT devices","volume":"9","author":"Pardeshi","year":"2020","journal-title":"Transl Vis Sci Technol."},{"key":"R19-20250723","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1097\/ICO.0000000000000529","article-title":"Validation of an objective scoring system for forme fruste keratoconus detection and post-LASIK ectasia risk assessment in asian eyes","volume":"34","author":"Chan","year":"2015","journal-title":"Cornea"},{"key":"R20-20250723","doi-asserted-by":"crossref","first-page":"5546","DOI":"10.1167\/iovs.10-5369","article-title":"Topographic and tomographic properties of forme fruste keratoconus corneas","volume":"51","author":"Saad","year":"2010","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R22-20250723","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1097\/APO.0000000000000333","article-title":"Determining progression in ectatic corneal disease","volume":"9","author":"Belin","year":"2020","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"R23-20250723","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.ajo.2017.06.031","article-title":"Keratoconus screening indices and their diagnostic ability to distinguish normal from ectatic corneas","volume":"181","author":"Shetty","year":"2017","journal-title":"Am J Ophthalmol."},{"key":"R24-20250723","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1080\/09286586.2019.1600199","article-title":"Repeatability and reproducibility of slit lamp, optical coherence tomography, and Scheimpflug measurements of corneal scars","volume":"26","author":"Das","year":"2019","journal-title":"Ophthalmic Epidemiol."},{"key":"R25-20250723","doi-asserted-by":"crossref","first-page":"250","DOI":"10.3928\/1081597X-20220114-02","article-title":"Repeatability and comparison of corneal tomography in mild to severe keratoconus between the anterior segment OCT MS-39 and Pentacam HR","volume":"38","author":"Seiler","year":"2022","journal-title":"J Refract Surg."},{"key":"R26-20250723","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s40662-022-00290-6","article-title":"Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis","volume":"9","author":"Herber","year":"2022","journal-title":"Eye Vis (Lond)"},{"key":"R27-20250723","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.jcrs.2012.10.033","article-title":"Intrasubject repeatability in keratoconus-eye measurements obtained with a new Scheimpflug photography-based system","volume":"39","author":"Montalb\u00e1n","year":"2013","journal-title":"J Cataract Refract Surg."},{"key":"R28-20250723","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1136\/bjophthalmol-2019-314954","article-title":"Multicentre study: reliability and repeatability of Scheimpflug system measurement in keratoconus","volume":"105","author":"de Luis Eguileor","year":"2021","journal-title":"Br J Ophthalmol."},{"key":"R29-20250723","doi-asserted-by":"crossref","first-page":"1378","DOI":"10.1097\/ICO.0000000000002925","article-title":"Scheimpflug versus optical coherence tomography to detect subclinical corneal edema in fuchs endothelial corneal dystrophy","volume":"41","author":"Augustin","year":"2022","journal-title":"Cornea"},{"key":"R30-20250723","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.joco.2016.01.009","article-title":"Pentacam top indices for diagnosing subclinical and definite keratoconus","volume":"28","author":"Hashemi","year":"2016","journal-title":"J Curr Ophthalmol."},{"key":"R31-20250723","doi-asserted-by":"crossref","first-page":"616","DOI":"10.3928\/1081597X-20180705-02","article-title":"Comparison of corneal tomography and a new combined tomographic biomechanical index in subclinical keratoconus","volume":"34","author":"Chan","year":"2018","journal-title":"J Refract Surg."},{"key":"R32-20250723","doi-asserted-by":"crossref","first-page":"1748579","DOI":"10.1155\/2019\/1748579","article-title":"Assessment of corneal pachymetry distribution and morphologic changes in subclinical keratoconus with normal biomechanics","volume":"2019","author":"Song","year":"2019","journal-title":"Biomed Res Int."},{"key":"R33-20250723","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1159\/000484712","article-title":"Unilateral keratoconus after chronic eye rubbing by the nondominant hand","volume":"8","author":"Bral","year":"2017","journal-title":"Case Rep Ophthalmol."},{"key":"R34-20250723","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1186\/s12886-022-02412-z","article-title":"Fourteen years follow-up of a stable unilateral Keratoconus: unique case report of clinical, tomographical and biomechanical stability","volume":"22","author":"Saad","year":"2022","journal-title":"BMC Ophthalmol."},{"key":"R35-20250723","doi-asserted-by":"crossref","first-page":"736","DOI":"10.3928\/1081597X-20151021-02","article-title":"Detection of keratoconus in clinically and algorithmically topographically normal fellow eyes using epithelial thickness analysis","volume":"31","author":"Reinstein","year":"2015","journal-title":"J Refract Surg."},{"key":"R36-20250723","doi-asserted-by":"crossref","first-page":"e0001","DOI":"10.1097\/coa.0000000000000001","article-title":"Three-year follow-up of biomechanical changes in very asymmetric ectasia","volume":"1","author":"Koh","year":"2022","journal-title":"Cornea Open"},{"key":"R37-20250723","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1097\/ICO.0000000000002283","article-title":"A case-control study of keratoconus risk factors","volume":"39","author":"Moran","year":"2020","journal-title":"Cornea"},{"key":"R38-20250723","doi-asserted-by":"crossref","first-page":"2431","DOI":"10.1007\/s00417-020-04771-z","article-title":"Incorrect sleeping position and eye rubbing in patients with unilateral or highly asymmetric keratoconus: a case-control study","volume":"258","author":"Mazharian","year":"2020","journal-title":"Graefes Arch Clin Exp Ophthalmol."},{"key":"R39-20250723","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1097\/ICU.0000000000000764","article-title":"The role of environment in the pathogenesis of keratoconus","volume":"32","author":"de Azevedo Magalh\u00e3es","year":"2021","journal-title":"Curr Opin Ophthalmol."},{"key":"R40-20250723","doi-asserted-by":"crossref","first-page":"66","DOI":"10.5005\/jp-journals-10025-1161","article-title":"Challenging the \u201cno rub, no cone\u201d keratoconus conjecture","volume":"7","author":"Gatinel","year":"2018","journal-title":"Int J Keratoconus Ectatic Corneal Dis."}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000003518","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T14:02:39Z","timestamp":1753279359000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000003518"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,13]]},"references-count":39,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0000000000003518","relation":{},"ISSN":["0277-3740"],"issn-type":[{"value":"0277-3740","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3,13]]},"assertion":[{"value":"2023-06-03","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-01-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}