{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T09:36:23Z","timestamp":1781775383018,"version":"3.54.5"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>Several techniques have been developed for graft unfolding approaches in Descemet membrane endothelial keratoplasty (DMEK). However, despite these techniques, graft deployment and configuration in eyes with deep anterior chambers remain challenging in some cases. Therefore, in this study, we described a modified technique for DMEK, known as the \u201cdouble-bubble technique assisted by holding forceps.\u201d<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This was a retrospective interventional case series. Patients who underwent DMEK between August 2022 and July 2023, including cases with a history of vitrectomy and scleral fixation of intraocular lens, were enrolled in this study. Two experienced surgeons performed DMEK. In brief, after graft insertion into the anterior chamber, the first bubble with a small volume of air was injected above the graft to open the tight roll, and the graft edge was held using a 25-gauge graft manipulator. The second bubble was injected underneath the graft for fixation, while the graft edge was grasped using forceps during gas injection. The graft was released from the forceps. Best spectacle corrected visual acuity, central corneal thickness, endothelial cell density, and incidence of postoperative complications were measured before and after DMEK.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Eleven eyes of 11 patients were included in this study (mean follow-up period, 4.5 \u00b1 4.4 months). Best spectacle corrected visual acuity and central corneal thickness significantly improved postoperatively (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). Rebubbling was required in 2 eyes; no other postoperative complications or primary graft failure were observed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The present technique enables safe and feasible DMEK surgery in vitrectomized eyes with scleral fixated IOLs and in those with a deep anterior chamber.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ico.0000000000003533","type":"journal-article","created":{"date-parts":[[2024,3,12]],"date-time":"2024-03-12T15:01:13Z","timestamp":1710255673000},"page":"799-803","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Double-Bubble Technique Assisted by Holding Forceps: A Modified Technique in Descemet Membrane Endothelial Keratoplasty for Vitrectomized Eyes With Scleral Fixated Intraocular Lens"],"prefix":"10.1097","volume":"43","author":[{"given":"Ami","family":"Igarashi","sequence":"first","affiliation":[{"name":"Division of Ophthalmology, Department of Visual Sciences, Nihon University School of Medicine, Itabashi, Tokyo, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideaki","family":"Yokogawa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kanazawa University Hospital, Kanazawa University Graduate School of Medical Science, Kanazawa, Ishikawa, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiki","family":"Shimizu","sequence":"additional","affiliation":[{"name":"Division of Ophthalmology, Department of Visual Sciences, Nihon University School of Medicine, Itabashi, Tokyo, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akira","family":"Kobayashi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kanazawa University Hospital, Kanazawa University Graduate School of Medical Science, Kanazawa, Ishikawa, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoru","family":"Yamagami","sequence":"additional","affiliation":[{"name":"Division of Ophthalmology, Department of Visual Sciences, Nihon University School of Medicine, Itabashi, Tokyo, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8704-680X","authenticated-orcid":false,"given":"Takahiko","family":"Hayashi","sequence":"additional","affiliation":[{"name":"Division of Ophthalmology, Department of Visual Sciences, Nihon University School of Medicine, Itabashi, Tokyo, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,3,12]]},"reference":[{"key":"R1-20250723","first-page":"987","article-title":"Descemet membrane endothelial keratoplasty (DMEK)","volume":"25","author":"Melles","year":"2006","journal-title":"Cornea"},{"key":"R2-20250723","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.ophtha.2011.09.019","article-title":"Risk of corneal transplant rejection significantly reduced with Descemet's membrane endothelial keratoplasty","volume":"119","author":"Anshu","year":"2012","journal-title":"Ophthalmology"},{"key":"R3-20250723","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1097\/ICO.0000000000000106","article-title":"Influence of donor characteristics on Descemet membrane endothelial keratoplasty","volume":"33","author":"Heinzelmann","year":"2014","journal-title":"Cornea"},{"key":"R4-20250723","doi-asserted-by":"crossref","first-page":"2459","DOI":"10.1007\/s00417-020-04852-z","article-title":"Impact of difficult unfolding and attachment of the graft lamella on the long-term outcome after Descemet membrane endothelial keratoplasty","volume":"258","author":"Gundlach","year":"2020","journal-title":"Graefes Arch Clin Exp Ophthalmol."},{"key":"R5-20250723","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1097\/ICO.0000000000001093","article-title":"Techniques for learning descemet membrane endothelial keratoplasty for eyes of asian patients with shallow anterior chamber","volume":"36","author":"Hayashi","year":"2017","journal-title":"Cornea"},{"key":"R6-20250723","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1001\/archophthalmol.2010.334","article-title":"Standardized \u201cno-touch\u201d technique for Descemet membrane endothelial keratoplasty","volume":"129","author":"Dapena","year":"2011","journal-title":"Arch Ophthalmol."},{"key":"R7-20250723","doi-asserted-by":"crossref","first-page":"1334","DOI":"10.1097\/ICO.0000000000001614","article-title":"Novel technique for improving graft unfolding in vitrectomized eyes using a temporary diaphragm in descemet membrane endothelial keratoplasty","volume":"37","author":"Yoeruek","year":"2018","journal-title":"Cornea"},{"key":"R8-20250723","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1001\/2013.jamaophthalmol.4","article-title":"Intraocular graft unfolding techniques in Descemet membrane endothelial keratoplasty","volume":"131","author":"Liarakos","year":"2013","journal-title":"JAMA Ophthalmol."},{"key":"R9-20250723","doi-asserted-by":"crossref","first-page":"101882","DOI":"10.1016\/j.ajoc.2023.101882","article-title":"Descemet membrane endothelial keratoplasty with cornea press technique and implantation of a Carlevale scleral-fixated intraocular lens","volume":"32","author":"Ghazal","year":"2023","journal-title":"Am J Ophthalmol Case Rep."},{"key":"R10-20250723","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1097\/ICO.0000000000001606","article-title":"Double-bubble technique in descemet membrane endothelial keratoplasty for vitrectomized eyes: a case series","volume":"37","author":"Hayashi","year":"2018","journal-title":"Cornea"},{"key":"R11-20250723","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1159\/000493571","article-title":"Development of a donor tissue holding technique for descemet's membrane endothelial keratoplasty using a 25-gauge graft manipulator","volume":"9","author":"Kobayashi","year":"2018","journal-title":"Case Rep Ophthalmol."},{"key":"R12-20250723","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1097\/ICO.0000000000002024","article-title":"C-press technique to facilitate descemet membrane endothelial keratoplasty surgery in vitrectomized patients: a case series","volume":"38","author":"Saad","year":"2019","journal-title":"Cornea"},{"key":"R13-20250723","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1097\/ICO.0000000000002228","article-title":"Long-term outcomes of descemet membrane endothelial keratoplasty in postvitrectomized eyes with the use of pars plana infusion","volume":"39","author":"Mednick","year":"2020","journal-title":"Cornea"},{"key":"R14-20250723","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.ophtha.2015.10.050","article-title":"Contact lens-assisted pull-through technique for delivery of tri-folded (endothelium in) DMEK grafts minimizes surgical time and cell loss","volume":"123","author":"Busin","year":"2016","journal-title":"Ophthalmology"},{"key":"R15-20250723","doi-asserted-by":"crossref","first-page":"2425","DOI":"10.1007\/s10792-021-01797-y","article-title":"Descemet membrane endothelial keratoplasty in vitrectomized eyes: a case series of outcomes and complications","volume":"41","author":"Phylactou","year":"2021","journal-title":"Int Ophthalmol."},{"key":"R16-20250723","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1136\/bjophthalmol-2020-316478","article-title":"The Cologne rebubbling study: a reappraisal of 624 rebubblings after Descemet membrane endothelial keratoplasty","volume":"105","author":"Siebelmann","year":"2021","journal-title":"Br J Ophthalmol."},{"key":"R17-20250723","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.survophthal.2017.07.003","article-title":"Graft detachment and rebubbling rate in Descemet membrane endothelial keratoplasty","volume":"63","author":"Parekh","year":"2018","journal-title":"Surv Ophthalmol."},{"key":"R18-20250723","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1001\/jamaophthalmol.2015.3064","article-title":"Endothelial survival after descemet membrane endothelial keratoplasty: effect of surgical indication and graft adherence status","volume":"133","author":"Baydoun","year":"2015","journal-title":"JAMA Ophthalmol."},{"key":"R19-20250723","doi-asserted-by":"crossref","first-page":"e0234202","DOI":"10.1371\/journal.pone.0234202","article-title":"Factors associated with endothelial cell density loss post Descemet membrane endothelial keratoplasty for bullous keratopathy in Asia","volume":"15","author":"Inoda","year":"2020","journal-title":"PLoS One"},{"key":"R20-20250723","doi-asserted-by":"crossref","first-page":"101688","DOI":"10.1016\/j.ajoc.2022.101688","article-title":"Temporary iris-lens diaphragm to assist Descemet membrane endothelial keratoplasty in aphakic patients","volume":"28","author":"Szurman","year":"2022","journal-title":"Am J Ophthalmol Case Rep."},{"key":"R21-20250723","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1097\/ICO.0000000000003213","article-title":"Posterior segment air injection-assisted descemet membrane endothelial keratoplasty in pseudophakic and vitrectomized eyes","volume":"42","author":"Li","year":"2023","journal-title":"Cornea"}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000003533","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T14:04:25Z","timestamp":1753279465000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000003533"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,12]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0000000000003533","relation":{},"ISSN":["0277-3740"],"issn-type":[{"value":"0277-3740","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3,12]]},"assertion":[{"value":"2023-12-18","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-02-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}