{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T04:07:30Z","timestamp":1746504450664,"version":"3.40.4"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2024,7,16]],"date-time":"2024-07-16T00:00:00Z","timestamp":1721088000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["81970768"],"award-info":[{"award-number":["81970768"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate the outcomes of divided residual donor corneas obtained from endothelial keratoplasty in keratoconus with deep anterior lamellar keratoplasty (DALK).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>In this retrospective, comparative, clinical study, 103 keratoconic eyes that underwent DALK were enrolled; 67 eyes received thin grafts from Descemet stripping automated endothelial keratoplasty, and 36 received thick grafts from Descemet membrane endothelial keratoplasty. Baseline and postoperative central corneal thickness (CCT), inferior corneal thickness, uncorrected distance visual acuity, corrected distance visual acuity, corneal astigmatism, mean keratometry, biomechanical properties, and complication rates were measured.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Six months after transplantation, the group receiving thin grafts had a CCT of only 455.1 \u00b1 43.0 \u03bcm, whereas that of the group receiving thick grafts was 546.7 \u00b1 44.2 \u03bcm. Both CCT and inferior corneal thickness in the thin group were significantly lower than those in the thick group (measured with Pentacam at 36 months, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001) and remained throughout the 5-year follow-up period. Both procedures had comparable postoperative logarithm of the minimum angle of resolution UDVAs, logarithm of the minimum angle of resolution corrected distance visual acuity, astigmatism, and mean keratometry values (36 months; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.335, 0.286, 0.680, and 0.365, respectively). Corneal biomechanical analysis revealed that the thin group had a significantly higher stiffness parameter at the first applanation than the thick group at the 2-year follow-up (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.036) while other parameters were equivalent.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The outcomes of keratoplasty with donor tissue are comparable regardless of the thickness of the graft, which suggests that transplantation with either type of the split corneal procedure for DALK in patients with keratoconus is feasible.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ico.0000000000003580","type":"journal-article","created":{"date-parts":[[2024,7,16]],"date-time":"2024-07-16T04:01:27Z","timestamp":1721102487000},"page":"685-691","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Outcomes of Donor Corneas of Different Thicknesses From Endothelial Keratoplasty in Deep Anterior Lamellar Keratoplasty for Keratoconus"],"prefix":"10.1097","volume":"44","author":[{"given":"Yinghan","family":"Zhao","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital, Beijing, China; and"},{"name":"Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaiyue","family":"Du","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital, Beijing, China; and"},{"name":"Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rongmei","family":"Peng","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital, Beijing, China; and"},{"name":"Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8079-2073","authenticated-orcid":false,"given":"Jing","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital, Beijing, China; and"},{"name":"Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,7,16]]},"reference":[{"key":"R1-20250505","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1097\/00003226-200011000-00010","article-title":"Trends in the indications for penetrating keratoplasty in the midwestern United States","volume":"19","author":"Dobbins","year":"2000","journal-title":"Cornea"},{"key":"R2-20250505","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1001\/jamaophthalmol.2015.4776","article-title":"Global survey of corneal transplantation and eye banking","volume":"134","author":"Gain","year":"2016","journal-title":"JAMA Ophthalmol."},{"key":"R3-20250505","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.ophtha.2010.11.002","article-title":"Deep anterior lamellar keratoplasty as an alternative to penetrating keratoplasty a report by the american academy of ophthalmology","volume":"118","author":"Reinhart","year":"2011","journal-title":"Ophthalmology"},{"key":"R4-20250505","doi-asserted-by":"crossref","first-page":"31","DOI":"10.3129\/i08-187","article-title":"Efficacy of Routine Notification and Request on reducing corneal transplantation wait times in Canada","volume":"44","author":"Rasouli","year":"2009","journal-title":"Can J Ophthalmol."},{"key":"R5-20250505","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1001\/archopht.125.4.552","article-title":"One donor cornea for 3 recipients: a new concept for corneal transplantation surgery","volume":"125","author":"Vajpayee","year":"2007","journal-title":"Arch Ophthalmol."},{"key":"R6-20250505","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.ophtha.2010.05.025","article-title":"Split cornea transplantation for 2 recipients: a new strategy to reduce corneal tissue cost and shortage","volume":"118","author":"Heindl","year":"2011","journal-title":"Ophthalmology"},{"key":"R7-20250505","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.ajo.2011.03.021","article-title":"Split cornea transplantation for 2 recipients - review of the first 100 consecutive patients","volume":"152","author":"Heindl","year":"2011","journal-title":"Am J Ophthalmol."},{"key":"R8-20250505","doi-asserted-by":"crossref","first-page":"1140","DOI":"10.1097\/ICO.0b013e318209d23c","article-title":"Optimal use of donor corneal tissue: one cornea for two recipients","volume":"30","author":"Sharma","year":"2011","journal-title":"Cornea"},{"key":"R9-20250505","first-page":"987","article-title":"Descemet membrane endothelial keratoplasty (DMEK)","volume":"25","author":"Melles","year":"2006","journal-title":"Cornea"},{"key":"R10-20250505","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.ajo.2021.06.013","article-title":"Long-term outcomes in fellow eyes comparing DSAEK and DMEK for treatment of fuchs corneal dystrophy","volume":"233","author":"Weisenthal","year":"2022","journal-title":"Am J Ophthalmol."},{"key":"R11-20250505","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/ICO.0000000000002118","article-title":"Surgeon preference for endothelial keratoplasty techniques","volume":"39","author":"Varadaraj","year":"2020","journal-title":"Cornea"},{"key":"R12-20250505","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.jcjo.2016.05.005","article-title":"Dual-purpose corneal tissue for anterior lamellar keratoplasty and Descemet's membrane endothelial keratoplasty","volume":"51","author":"Menant-Tay","year":"2016","journal-title":"Can J Ophthalmol."},{"key":"R13-20250505","doi-asserted-by":"crossref","first-page":"2441","DOI":"10.4103\/ijo.IJO_3044_20","article-title":"A simple surgical technique for splitting a single donor cornea for performing deep anterior lamellar keratoplasty and Descemet membrane endothelial keratoplasty without using a microkeratome","volume":"69","author":"Siddharthan","year":"2021","journal-title":"Indian J Ophthalmol."},{"key":"R14-20250505","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1097\/OPX.0000000000001193","article-title":"Effects of thickness on corneal biomechanical properties using optical coherence elastography","volume":"95","author":"Vantipalli","year":"2018","journal-title":"Optom Vis Sci."},{"key":"R15-20250505","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1097\/ICL.0000000000000076","article-title":"Deep anterior lamellar keratoplasty for keratoconus: a review","volume":"40","author":"Maharana","year":"2014","journal-title":"Eye Contact Lens"},{"key":"R16-20250505","doi-asserted-by":"crossref","first-page":"2831","DOI":"10.4103\/ijo.IJO_2078_20","article-title":"ABCD: a new classification for keratoconus","volume":"68","author":"Belin","year":"2020","journal-title":"Indian J Ophthalmol."},{"key":"R17-20250505","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.jfo.2017.06.006","article-title":"Intraocular pressure measurements and corneal biomechanical properties using a dynamic Scheimpflug analyzer, after several keratoplasty techniques, versus normal eyes","volume":"41","author":"Hugo","year":"2018","journal-title":"J Fr Ophtalmol"},{"key":"R18-20250505","doi-asserted-by":"crossref","first-page":"35","DOI":"10.4103\/0301-4738.90490","article-title":"Corneal endothelium after deep anterior lamellar keratoplasty and penetrating keratoplasty for keratoconus: a four-year comparative study","volume":"60","author":"Kubaloglu","year":"2012","journal-title":"Indian J Ophthalmol."},{"key":"R19-20250505","doi-asserted-by":"crossref","first-page":"18594","DOI":"10.1038\/s41598-020-75412-y","article-title":"Risk factors and evaluation of keratoconus progression after penetrating keratoplasty with anterior segment optical coherence tomography","volume":"10","author":"Yoshida","year":"2020","journal-title":"Sci Rep."},{"key":"R20-20250505","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1136\/bjo.2003.027037","article-title":"Late onset post-keratoplasty astigmatism in patients with keratoconus","volume":"88","author":"Lim","year":"2004","journal-title":"Br J Ophthalmol."},{"key":"R21-20250505","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.ajo.2008.08.001","article-title":"Long-term keratometric changes after penetrating keratoplasty for keratoconus and Fuchs Endothelial dystrophy","volume":"147","author":"Raecker","year":"2009","journal-title":"Am J Ophthalmol."},{"key":"R22-20250505","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.1007\/s00417-018-4131-5","article-title":"Characteristics and risk factors of recurrent keratoconus over the long term after penetrating keratoplasty","volume":"256","author":"Yoshida","year":"2018","journal-title":"Graefes Arch Clin Exp Ophthalmol."},{"key":"R23-20250505","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1016\/j.survophthal.2021.11.005","article-title":"Post-penetrating keratoplasty astigmatism","volume":"67","author":"Deshmukh","year":"2022","journal-title":"Surv Ophthalmol."},{"key":"R24-20250505","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1016\/j.survophthal.2018.05.004","article-title":"Biomechanics and structure of the cornea: implications and association with corneal disorders","volume":"63","author":"Ma","year":"2018","journal-title":"Surv Ophthalmol."},{"key":"R25-20250505","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1098\/rsif.2004.0002","article-title":"Application of structural analysis to the mechanical behaviour of the cornea","volume":"1","author":"Anderson","year":"2004","journal-title":"J R Soc Interf."},{"key":"R26-20250505","doi-asserted-by":"crossref","first-page":"4490","DOI":"10.1167\/iovs.14-14450","article-title":"Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy","volume":"55","author":"Scarcelli","year":"2014","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"R27-20250505","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1136\/bjophthalmol-2017-310355","article-title":"Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus","volume":"102","author":"Chan","year":"2018","journal-title":"Br J Ophthalmol."},{"key":"R28-20250505","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.joco.2017.05.002","article-title":"Keratoconus diagnosis using Corvis ST measured biomechanical parameters","volume":"29","author":"Elham","year":"2017","journal-title":"J Curr Ophthalmol."},{"key":"R29-20250505","doi-asserted-by":"crossref","first-page":"434","DOI":"10.3928\/1081597X-20170426-02","article-title":"Integration of scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection","volume":"33","author":"Ambr\u00f3sio","year":"2017","journal-title":"J Refract Surg."},{"key":"R30-20250505","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/ICU.0b013e3283622a94","article-title":"Scheimpflug imaging for laser refractive surgery","volume":"24","author":"Ambr\u00f3sio","year":"2013","journal-title":"Curr Opin Ophthalmol."},{"key":"R31-20250505","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1111\/ceo.13677","article-title":"Comparison of corneal biomechanical properties following penetrating keratoplasty and deep anterior lamellar keratoplasty for keratoconus","volume":"48","author":"Ziaei","year":"2020","journal-title":"Clin Exp Ophthalmol."},{"key":"R32-20250505","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/s40662-020-00225-z","article-title":"Relationship between corneal biomechanical parameters and corneal sublayer thickness measured by Corvis ST and UHR-OCT in keratoconus and normal eyes","volume":"8","author":"Li","year":"2021","journal-title":"Eye Vis (Lond)"},{"key":"R33-20250505","doi-asserted-by":"crossref","first-page":"550","DOI":"10.3928\/1081597X-20160524-01","article-title":"Influence of pachymetry and intraocular pressure on dynamic corneal response parameters in healthy patients","volume":"32","author":"Vinciguerra","year":"2016","journal-title":"J Refract Surg."},{"key":"R34-20250505","doi-asserted-by":"crossref","first-page":"147516","DOI":"10.1155\/2014\/147516","article-title":"Corneal biomechanical assessment using corneal visualization scheimpflug technology in keratoconic and normal eyes","volume":"2014","author":"Tian","year":"2014","journal-title":"J Ophthalmol."},{"key":"R35-20250505","doi-asserted-by":"crossref","first-page":"105","DOI":"10.3389\/fbioe.2019.00105","article-title":"Determination of corneal biomechanical behavior in-vivo for healthy eyes using CorVis ST tonometry: stress-strain index","volume":"7","author":"Eliasy","year":"2019","journal-title":"Front Bioeng Biotechnol."},{"key":"R36-20250505","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/j.survophthal.2019.02.011","article-title":"Intraocular pressure measurement after corneal transplantation","volume":"64","author":"de Padua Soares Bezerra","year":"2019","journal-title":"Surv Ophthalmol."},{"key":"R37-20250505","first-page":"120","article-title":"Costs and financing. A cost calculation of an up-to-date eye bank in Germany","volume":"43","author":"B\u00f6hringer","year":"2009","journal-title":"Dev Ophthalmol."}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000003580","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T20:04:48Z","timestamp":1746475488000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000003580"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,16]]},"references-count":37,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0000000000003580","relation":{},"ISSN":["0277-3740","1536-4798"],"issn-type":[{"type":"print","value":"0277-3740"},{"type":"electronic","value":"1536-4798"}],"subject":[],"published":{"date-parts":[[2024,7,16]]},"assertion":[{"value":"2024-03-19","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-04-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}