{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T06:53:29Z","timestamp":1780469609167,"version":"3.54.1"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To assess the accuracy of various Pentacam indices in distinguishing keratoconus (KC) in pediatric patients with high astigmatism and to establish appropriate cutoff values.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective multicenter cross-sectional study included 312 eyes from 167 patients aged 6 to 18 years (mean age, 13.1 \u00b1 3.2 years) evaluated with Oculus Pentacam HR. Patients were categorized into 4 groups: KC, forme fruste keratoconus, astigmatism greater than 2 diopters (Cyl2D), and control. A subgroup of Cyl2D comprised patients with astigmatism greater than 4 diopters (Cyl4D). Twenty-three Pentacam indices were analyzed, and receiver operating characteristic curves determined optimal cutoff points, sensitivity, and specificity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The best indices for distinguishing KC from Cyl2D were high-order aberration root mean square of the anterior corneal surface (area under the receiver operating characteristic curve 0.987), Belin\/Ambrosio enhanced ectasia total derivation (0.971), index of vertical asymmetry (0.971), average pachymetric progression index (0.962), maximum Ambrosio relational thickness (0.960), posterior elevation (0.952), and anterior elevation (0.948). The accuracy of these indices was highest in the control group and lowest in the Cyl4D group. Area under the receiver operating characteristic curve was significantly lower for fruste keratoconus than KC. Optimal cutoff values were higher for astigmatic patients than for those with no refractive error.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Most indices effectively distinguished between KC and normal pediatric patients. For individuals with high astigmatism, we suggest focusing on specific indices such as high-order aberration root mean square, Belin\/Ambrosio enhanced ectasia total derivation value, maximum Ambrosio relational thickness, average pachymetric progression index, and index of vertical asymmetry. Optimal cutoff points for these patients were higher than those for nonastigmatic children and differed from adult populations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/ico.0000000000003755","type":"journal-article","created":{"date-parts":[[2024,11,6]],"date-time":"2024-11-06T10:00:32Z","timestamp":1730887232000},"page":"1521-1527","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Keratoconus Detection in High-Astigmatism Pediatric Patients: Optimal Pentacam Indices and Cutoff Points"],"prefix":"10.1097","volume":"44","author":[{"given":"Renato","family":"Souza Oliveira","sequence":"first","affiliation":[{"name":"Instituto Brasileiro de Oftalmologia \u2013 IBOL, Rio de Janeiro, Brazil;"},{"name":"Faculty of Medicine, University of Coimbra, Coimbra, Portugal;"},{"name":"Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of S\u00e3o Paulo \u2013 UNIFESP, S\u00e3o Paulo, Brazil; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00e3o Quadrado","family":"Gil","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of Coimbra, Coimbra, Portugal;"},{"name":"Centro de Responsabilidade Integrado de Oftalmologia, Centro Hospitalar e Universit\u00e1rio de Coimbra, Coimbra, Portugal."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreia","family":"Rosa","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of Coimbra, Coimbra, Portugal;"},{"name":"Centro de Responsabilidade Integrado de Oftalmologia, Centro Hospitalar e Universit\u00e1rio de Coimbra, Coimbra, Portugal."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Jo\u00e3o","family":"Quadrado","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, University of Coimbra, Coimbra, Portugal;"},{"name":"Centro de Responsabilidade Integrado de Oftalmologia, Centro Hospitalar e Universit\u00e1rio de Coimbra, Coimbra, Portugal."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauro","family":"Campos","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of S\u00e3o Paulo \u2013 UNIFESP, S\u00e3o Paulo, Brazil; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,11,6]]},"reference":[{"key":"R1-20251111","doi-asserted-by":"crossref","first-page":"2257","DOI":"10.1007\/s10792-017-0699-8","article-title":"Pediatric keratoconus: a review of the literature","volume":"38","author":"Mukhtar","year":"2018","journal-title":"Int Ophthalmol"},{"key":"R2-20251111","doi-asserted-by":"crossref","first-page":"8278","DOI":"10.1038\/s41598-022-12070-2","article-title":"Comparing the natural progression and clinical features of keratoconus between pediatric and adult patients","volume":"12","author":"Lin","year":"2022","journal-title":"Sci Rep"},{"key":"R3-20251111","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.optom.2019.11.001","article-title":"A review of corneal imaging methods for the early diagnosis of pre-clinical keratoconus","volume":"13","author":"Masiwa","year":"2020","journal-title":"J Optom"},{"key":"R4-20251111","doi-asserted-by":"crossref","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","article-title":"Detection of keratoconus with a new biomechanical index","volume":"32","author":"Vinciguerra","year":"2016","journal-title":"J Refract Surg"},{"key":"R5-20251111","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1016\/j.jcrs.2006.06.025","article-title":"Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus","volume":"32","author":"Ambr\u00f3sio","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R6-20251111","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1097\/ICO.0000000000002481","article-title":"Normative values of various pentacam HR parameters for pediatric corneas","volume":"39","author":"Hashem","year":"2020","journal-title":"Cornea"},{"key":"R7-20251111","first-page":"177","article-title":"Pentacam\u00ae corneal tomography for screening of refractive surgery candidates: a review of the literature, part I","volume":"8","author":"Motlagh","year":"2019","journal-title":"Med Hypothesis Discov Innov Ophthalmol"},{"key":"R8-20251111","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/ICL.0000000000000622","article-title":"Distribution of keratoconus indices in normal children 6 to 12 years of age","volume":"46","author":"Hashemi","year":"2020","journal-title":"Eye Contact Lens"},{"key":"R9-20251111","doi-asserted-by":"crossref","first-page":"6370791","DOI":"10.1155\/2022\/6370791","article-title":"Clinical study on the differential diagnosis of high myopia astigmatism and subclinical keratoconus in adolescents by pentacam anterior segment analyzer","volume":"2022","author":"Ruan","year":"2022","journal-title":"Contrast Media Mol Imaging"},{"issue":"suppl 10","key":"R10-20251111","doi-asserted-by":"crossref","first-page":"S57","DOI":"10.1097\/ICO.0000000000000608","article-title":"Intereye asymmetry in eyes with keratoconus and high ammetropia: scheimpflug imaging analysis","volume":"34","author":"Henriquez","year":"2015","journal-title":"Cornea"},{"key":"R11-20251111","first-page":"213","article-title":"Prevalence of keratoconus and subclinical keratoconus in subjects with astigmatism using pentacam derived parameters","volume":"8","author":"Serdarogullari","year":"2013","journal-title":"J Ophthalmic Vis Res"},{"key":"R12-20251111","doi-asserted-by":"crossref","first-page":"e0260648","DOI":"10.1371\/journal.pone.0260648","article-title":"The utility of measures of anterior segment parameters of a Pentacam Scheimpflug tomographer in discriminating high myopic astigmatism from keratoconus","volume":"16","author":"Zaabaar","year":"2021","journal-title":"PLoS One"},{"key":"R13-20251111","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1001\/archopht.1995.01100070044023","article-title":"Comparison of methods for detecting keratoconus using videokeratography","volume":"113","author":"Maeda","year":"1995","journal-title":"Arch Ophthalmol"},{"key":"R14-20251111","doi-asserted-by":"crossref","first-page":"400","DOI":"10.3928\/1081-597X-19891101-10","article-title":"Computer-assisted corneal topography in keratoconus","volume":"5","author":"Rabinowitz","year":"1989","journal-title":"Refract Corneal Surg"},{"key":"R15-20251111","doi-asserted-by":"crossref","first-page":"270","DOI":"10.3928\/1081597X-20200212-03","article-title":"A systematic review of subclinical keratoconus and forme fruste keratoconus","volume":"36","author":"Henriquez","year":"2020","journal-title":"J Refract Surg"},{"key":"R17-20251111","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1136\/bmj.309.6948.188","article-title":"Diagnostic tests 3: receiver operating characteristic plots","volume":"309","author":"Altman","year":"1994","journal-title":"BMJ"},{"key":"R18-20251111","doi-asserted-by":"crossref","first-page":"837","DOI":"10.2307\/2531595","article-title":"Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach","volume":"44","author":"DeLong","year":"1988","journal-title":"Biometrics"},{"key":"R19-20251111","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1002\/bimj.200410133","article-title":"The Youden Index and the optimal cut-point corrected for measurement error","volume":"47","author":"Perkins","year":"2005","journal-title":"Biom J"},{"key":"R20-20251111","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1097\/ICO.0000000000001579","article-title":"Corneal cross-linking for pediatric keratcoconus review","volume":"37","author":"Perez-Straziota","year":"2018","journal-title":"Cornea"},{"key":"R21-20251111","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1007\/s40123-022-00508-9","article-title":"Pediatric crosslinking: current protocols and approach","volume":"11","author":"Polido","year":"2022","journal-title":"Ophthalmol Ther"},{"key":"R22-20251111","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.1038\/s41433-022-02070-x","article-title":"Diagnostic accuracy of different keratoconus detection indices of pentacam in paediatric eyes","volume":"37","author":"Hashem","year":"2023","journal-title":"Eye (Lond)"},{"key":"R23-20251111","doi-asserted-by":"crossref","first-page":"24275","DOI":"10.1038\/s41598-021-03818-3","article-title":"Corneal Scheimpflug topography values to distinguish between normal eyes, ocular allergy, and keratoconus in children","volume":"11","author":"Vieira","year":"2021","journal-title":"Sci Rep"},{"key":"R24-20251111","doi-asserted-by":"crossref","first-page":"2532","DOI":"10.1177\/11206721221081467","article-title":"The false positive rates for detecting keratoconus and potential ectatic corneal conditions when evaluating astigmatic eyes with Scheimpflug Technology","volume":"32","author":"Henriquez","year":"2022","journal-title":"Eur J Ophthalmol"},{"key":"R25-20251111","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.ajo.2017.06.031","article-title":"Keratoconus screening indices and their diagnostic ability to distinguish normal from ectatic corneas","volume":"181","author":"Shetty","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"R26-20251111","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1097\/ICL.0000000000001072","article-title":"Prevalence of keratoconus based on scheimpflug corneal tomography metrics in a pediatric population from a chicago-based school age vision clinic","volume":"50","author":"Harthan","year":"2024","journal-title":"Eye Contact Lens"},{"key":"R27-20251111","doi-asserted-by":"crossref","first-page":"434","DOI":"10.3928\/1081597X-20170426-02","article-title":"Integration of Scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection","volume":"33","author":"Ambr\u00f3sio","year":"2017","journal-title":"J Refract Surg"},{"key":"R28-20251111","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1097\/j.jcrs.0000000000000990","article-title":"Systematic detection of keratoconus in OCT: corneal and epithelial thickness maps","volume":"48","author":"Y\u00fccekul","year":"2022","journal-title":"J Cataract Refract Surg"}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000003755","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T20:01:48Z","timestamp":1762891308000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0000000000003755"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,6]]},"references-count":27,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0000000000003755","relation":{},"ISSN":["0277-3740","1536-4798"],"issn-type":[{"value":"0277-3740","type":"print"},{"value":"1536-4798","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,6]]},"assertion":[{"value":"2024-08-02","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-10-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}