{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:07:52Z","timestamp":1786118872160,"version":"build-2736575974"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2008,12]]},"DOI":"10.1097\/ico.0b013e31817f812e","type":"journal-article","created":{"date-parts":[[2008,11,5]],"date-time":"2008-11-05T03:11:30Z","timestamp":1225854690000},"page":"1103-1108","source":"Crossref","is-referenced-by-count":18,"title":["Whole Globe Enucleation Versus In Situ Excision for Donor Corneal Retrieval-A Prospective Comparative Study"],"prefix":"10.1097","volume":"27","author":[{"given":"Vishal","family":"Jhanji","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Radhika","family":"Tandon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Namrata","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeewan S","family":"Titiyal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gita","family":"Satpathy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rasik B","family":"Vajpayee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-1-20210204","first-page":"293","article-title":"Excision of the donor cornea instead of enucleation.","volume":"14","author":"Vannas","year":"1975","journal-title":"Invest Ophthalmol"},{"key":"R2-1-20210204","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1007\/s003470050203","article-title":"Corneoscleral transplant excision in the cadaver. Experiences of the North Rhine Westphalia Lions Cornea Bank 1995 and 1996.","volume":"94","author":"Hudde","year":"1997","journal-title":"Ophthalmologe"},{"key":"R3-1-20210204","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1097\/ICO.0b013e31802c9e05","article-title":"In situ versus whole-globe harvesting of corneal tissue from remote donor sites: effects on initial tissue quality.","volume":"26","author":"Rootman","year":"2007","journal-title":"Cornea"},{"key":"R4-1-20210204","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/00003226-199407000-00004","article-title":"Whole globe enucleation versus in situ corneal excision: a study of tissue trauma and contamination.","volume":"13","author":"Lane","year":"1994","journal-title":"Cornea"},{"key":"R6-1-20210204","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/S0147-9563(96)80016-1","article-title":"Families experiences in consenting to eye donation of a recently deceased relative.","volume":"25","author":"Doering","year":"1996","journal-title":"Heart Lung"},{"key":"R7-1-20210204","first-page":"110","article-title":"Eye banking in India.","volume":"37","author":"Kalevar","year":"1989","journal-title":"Indian J Ophthalmol"},{"key":"R8-1-20210204","first-page":"318","article-title":"Eye donation movement in India.","volume":"97","author":"Kannan","year":"1999","journal-title":"J Indian Med Assoc"},{"key":"R9-1-20210204","first-page":"327","article-title":"Questions on organ donation. An exploratory study of medical students and overview of the literature.","volume":"46","author":"Strenge","year":"1996","journal-title":"Psychother Psychosom Med Psychol"},{"key":"R10-1-20210204","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1097\/01.ico.0000121706.58571.f6","article-title":"Factors affecting eye donation from postmortem cases in a tertiary care hospital.","volume":"23","author":"Tandon","year":"2004","journal-title":"Cornea"},{"key":"R11-1-20210204","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1111\/j.1600-0420.1997.tb00132.x","article-title":"Corneoscleral discs excised from enucleated and non-enucleated eyes are equally suitable for transplantation.","volume":"75","author":"Garweg","year":"1997","journal-title":"Acta Ophthalmol Scand"},{"key":"R12-1-20210204","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1097\/00003226-200108000-00006","article-title":"Corneoscleral rim cultures: lack of utility and implications of clinical decision-making and infection prevention in care of patients undergoing corneal transplantation.","volume":"20","author":"Everts","year":"2001","journal-title":"Cornea"},{"key":"R13-1-20210204","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1016\/j.ophtha.2006.09.006","article-title":"The prognostic role of donor corneoscleral rim cultures in corneal transplantation.","volume":"114","author":"Wilhelmus","year":"2007","journal-title":"Ophthalmology"},{"key":"R14-1-20210204","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1097\/ICO.0b013e3180415d7e","article-title":"Frequency of positive donor rim cultures after penetrating keratoplasty using hypothermic and organ-cultured donor corneas.","volume":"26","author":"Fontana","year":"2007","journal-title":"Cornea"},{"key":"R15-1-20210204","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/0002-9394(86)90082-6","article-title":"Donor corneal endothelial striae.","volume":"102","author":"Grutzmacher","year":"1986","journal-title":"Am J Ophthalmol"}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/ICO.0b013e31817f812e","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T17:12:09Z","timestamp":1786036329000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00003226-200812000-00001"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,12]]},"references-count":14,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2008]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0b013e31817f812e","relation":{},"ISSN":["0277-3740"],"issn-type":[{"value":"0277-3740","type":"print"}],"subject":[],"published":{"date-parts":[[2008,12]]}}}