{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T09:36:26Z","timestamp":1791106586636,"version":"4.1.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2011,8]]},"DOI":"10.1097\/ico.0b013e31820143d1","type":"journal-article","created":{"date-parts":[[2011,3,9]],"date-time":"2011-03-09T10:11:00Z","timestamp":1299665460000},"page":"917-919","source":"Crossref","is-referenced-by-count":89,"title":["Limitation of Collagen Cross-Linking With Hypoosmolar Riboflavin Solution: Failure in an Extremely Thin Cornea"],"prefix":"10.1097","volume":"30","author":[{"given":"Farhad","family":"Hafezi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-15-20210227","first-page":"711","article-title":"Techniques for stiffening the cornea.","volume":"15","author":"Spoerl","year":"1999","journal-title":"J Refract Surg"},{"key":"R2-15-20210227","doi-asserted-by":"crossref","first-page":"371","DOI":"10.3928\/1081597X-20090401-02","article-title":"Contralateral eye study of corneal collagen cross-linking with riboflavin and UVA irradiation in patients with keratoconus.","volume":"25","author":"Coskunseven","year":"2009","journal-title":"J Refract Surg"},{"key":"R3-15-20210227","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/S0002-9394(02)02220-1","article-title":"Riboflavin\/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus.","volume":"135","author":"Wollensak","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R4-15-20210227","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1016\/j.jcrs.2007.07.028","article-title":"Corneal collagen cross-linking with riboflavin\/UVA for the treatment of induced keratectasia after laser in situ keratomileusis.","volume":"33","author":"Hafezi","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R5-15-20210227","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1097\/ICO.0b013e318169d698","article-title":"Ultraviolet A\/riboflavin corneal cross-linking for infectious keratitis associated with corneal melts.","volume":"27","author":"Iseli","year":"2008","journal-title":"Cornea"},{"key":"R7-15-20210227","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1097\/ICO.0b013e3180334f78","article-title":"Safety of UVA-riboflavin cross-linking of the cornea.","volume":"26","author":"Spoerl","year":"2007","journal-title":"Cornea"},{"key":"R8-15-20210227","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/j.jcrs.2008.10.060","article-title":"Collagen crosslinking with ultraviolet-A and hypoosmolar riboflavin solution in thin corneas.","volume":"35","author":"Hafezi","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R9-15-20210227","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1097\/ICU.0b013e3281ca7121","article-title":"Measuring the cornea: the latest developments in corneal topography.","volume":"18","author":"Swartz","year":"2007","journal-title":"Curr Opin Ophthalmol"},{"key":"R10-15-20210227","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1097\/01.ico.0000225720.38748.58","article-title":"Corneal cross-linking-induced stromal demarcation line.","volume":"25","author":"Seiler","year":"2006","journal-title":"Cornea"},{"key":"R11-15-20210227","first-page":"158","article-title":"The swelling pressure of the corneal stroma.","volume":"1","author":"Dohlman","year":"1962","journal-title":"Invest Ophthalmol"},{"key":"R12-15-20210227","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1136\/bjo.35.12.791","article-title":"Swelling of the cornea in vivo after the destruction of its limiting layers.","volume":"35","author":"Maurice","year":"1951","journal-title":"Br J Ophthalmol"},{"key":"R14-15-20210227","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/0014-4835(72)90140-6","article-title":"Changes in the swelling pressure of the corneal stroma with time, hydration and temperature, determined by a new method.","volume":"14","author":"Hara","year":"1972","journal-title":"Exp Eye Res"}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00003226-201108000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T18:49:45Z","timestamp":1786042185000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00003226-201108000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,8]]},"references-count":12,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2011]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0b013e31820143d1","relation":{},"ISSN":["0277-3740"],"issn-type":[{"value":"0277-3740","type":"print"}],"subject":[],"published":{"date-parts":[[2011,8]]}}}