{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T02:50:34Z","timestamp":1784775034850,"version":"3.55.0"},"reference-count":38,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose of review<\/jats:title>\n                    <jats:p>This review focuses on the use in patients with keratoconus, of corneal allogeneic intrastromal ring segments (CAIRS) as well as customized and custom shaped CAIRS for corneal reshaping, stabilization and individualized, tissue-based corneal contouring, while delaying or avoiding keratoplasty.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Recent findings<\/jats:title>\n                    <jats:p>CAIRS is being widely used in advanced cases of keratoconus, as biological replacement for synthetic intra-corneal ring segments and to prevent the need  for keratoplasty. It is also being adopted in early disease in combination with\u00a0corneal cross-linking. Various techniques and modifications are described as well as its use in different situations. Femtosecond and double bladed trephined CAIRS are discussed, including recent unpublished data demonstrating comparable dimensional accuracy with both. Double bladed trephines may also offer potential for greater segment thickness and customization.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary<\/jats:title>\n                    <jats:p>CAIRS is evolving into a customizable corneal contouring approach that may complement and potentially reduce reliance on, existing treatment modalities. When combined with corneal cross-linking, it offers both biomechanical stabilization and visual rehabilitation. Future advances are likely to center on data-driven personalization tailored to each patient's corneal phenotype and visual needs, an approach that becomes increasingly important as CAIRS use expands in keratoconus<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/icu.0000000000001237","type":"journal-article","created":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T20:00:10Z","timestamp":1778961610000},"page":"289-298","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Corneal Allogeneic Intrastromal Ring Segments for keratoconus \u2013 recent evidence and the move to customized and custom shaped CAIRS"],"prefix":"10.1097","volume":"37","author":[{"given":"Soosan","family":"Jacob","sequence":"first","affiliation":[{"name":"Dr Agarwal's Refractive and Cornea Foundation"},{"name":"Dr Agarwal's Eye Hospital, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shady T.","family":"Awwad","sequence":"additional","affiliation":[{"name":"American University of Beirut, Lebanon"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amar","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Dr Agarwal's Eye Hospital, Chennai, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,5,14]]},"reference":[{"key":"R1-20260528","doi-asserted-by":"crossref","first-page":"101559","DOI":"10.1016\/j.clae.2021.101559","article-title":"Keratoconus: an updated review","volume":"45","author":"Santodomingo-Rubido","year":"2022","journal-title":"Cont Lens Anterior Eye"},{"key":"R2-20260528","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","article-title":"Keratoconus","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Surv Ophthalmol"},{"key":"R3-20260528","doi-asserted-by":"crossref","first-page":"234","DOI":"10.4274\/tjo.galenos.2020.70481","article-title":"Update on contact lens treatment of keratoconus","volume":"50","author":"\u015eeng\u00f6r","year":"2020","journal-title":"Turk J Ophthalmol"},{"key":"R4-20260528","first-page":"e83","article-title":"Biomechanical, visual, and refractive outcomes of total corneal wavefront-guided transepithelial PRK with accelerated CXL in keratoconus using objective stability markers","volume":"42","author":"Graue-Hernandez","year":"2026","journal-title":"J Refract Surg"},{"key":"R5-20260528","doi-asserted-by":"crossref","first-page":"1324","DOI":"10.1177\/11206721231155213","article-title":"Intracorneal ring segment implantation in advanced keratoconus","volume":"33","author":"Dockery","year":"2023","journal-title":"Eur J Ophthalmol"},{"key":"R6-20260528","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18502\/jovr.v20.15222","article-title":"Deep anterior lamellar keratoplasty versus penetrating keratoplasty in keratoconus: a retrospective study using coarsened exact matching","volume":"20","author":"Karimian","year":"2025","journal-title":"J Ophthalmic Vis Res"},{"key":"R7-20260528","doi-asserted-by":"crossref","first-page":"296","DOI":"10.3928\/1081597X-20180223-01","article-title":"Corneal allogenic intrastromal ring segments (CAIRS) combined with corneal cross-linking for keratoconus","volume":"34","author":"Jacob","year":"2018","journal-title":"J Refract Surg"},{"key":"R9-20260528","doi-asserted-by":"crossref","first-page":"e863","DOI":"10.3928\/1081597X-20241002-02","article-title":"Corneal allogenic intrastromal ring segments (CAIRS) versus synthetic segments: a single segment comparative analysis using propensity score matching","volume":"40","author":"Asfar","year":"2024","journal-title":"J Refract Surg"},{"key":"R10-20260528","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1097\/ICO.0000000000003431","article-title":"Bowman layer marking for correct placement of corneal allogeneic intrastromal ring segments","volume":"43","author":"Jacob","year":"2024","journal-title":"Cornea"},{"key":"R13-20260528","doi-asserted-by":"crossref","first-page":"3723","DOI":"10.4103\/IJO.IJO_1988_23","article-title":"Customized corneal allogenic intrastromal ring segments (CAIRS) for keratoconus with decentered asymmetric cone","volume":"71","author":"Jacob","year":"2023","journal-title":"Indian J Ophthalmol"},{"key":"R14-20260528","doi-asserted-by":"crossref","first-page":"3","DOI":"10.4103\/IJO.IJO_2589_24","article-title":"Custom-shaped CAIRS for personalized treatment of keratoconus","volume":"73","author":"Jacob","year":"2025","journal-title":"Indian J Ophthalmol"},{"key":"R15-20260528","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1007\/s10103-025-04689-0","article-title":"Novel application of diode engraving laser for preparing corneal allogenic intrastromal ring segments: a comparative study with femtosecond laser and manual trephine","volume":"40","author":"Alabbasi","year":"2025","journal-title":"Lasers Med Sci"},{"key":"R17-20260528","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1097\/ICO.0000000000003853","article-title":"A manual technique for corneal allogeneic intrastromal ring segments without a femtosecond laser","volume":"44","author":"Hayashi","year":"2025","journal-title":"Cornea"},{"key":"R19-20260528","doi-asserted-by":"crossref","first-page":"e37","DOI":"10.1097\/j.jcrs.0000000000000582","article-title":"Preimplantation dehydration for corneal allogenic intrastromal ring segment implantation","volume":"47","author":"Parker","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R20-20260528","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1097\/ICO.0000000000003328","article-title":"Extended dehydration of corneal allogenic intrastromal ring segments to facilitate insertion: the Corneal Jerky Technique","volume":"42","author":"Awwad","year":"2023","journal-title":"Cornea"},{"key":"R21-20260528","first-page":"1","article-title":"Rapid dehydration of corneal allogeneic intrastromal ring segments (CAIRSs) by thermal energy conduction and heating to facilitate implantation","volume":"00","author":"Awwad","year":"2025","journal-title":"Cornea"},{"key":"R22-20260528","doi-asserted-by":"crossref","first-page":"767","DOI":"10.3928\/1081597X-20231011-01","article-title":"Corneal allogenic intrastromal ring segments (CAIRS) for corneal ectasia: a comprehensive segmental tomography evaluation","volume":"39","author":"Bteich","year":"2023","journal-title":"J Refract Surg"},{"key":"R23-20260528","doi-asserted-by":"crossref","first-page":"856","DOI":"10.3928\/1081597X-20231018-04","article-title":"Asymmetric all-femtosecond laser-cut corneal allogenic intrastromal ring segments","volume":"39","author":"Bteich","year":"2023","journal-title":"J Refract Surg"},{"key":"R24-20260528","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1177\/11206721221142995","article-title":"Allograft corneal ring segment for keratoconus management: Istanbul nomogram clinical results","volume":"33","author":"Haciagaoglu","year":"2022","journal-title":"Eur J Ophthalmol"},{"key":"R25-20260528","first-page":"1","article-title":"Femtosecond laser created corneal allogenic intrastromal ring segments for keratoconus","author":"Gunn","year":"2026","journal-title":"Clin Exp Ophthalmol"},{"key":"R26-20260528","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1097\/j.jcrs.0000000000001187","article-title":"Corneal tissue addition keratoplasty: new intrastromal inlay procedure for keratoconus using femtosecond laser-shaped preserved corneal tissue","volume":"49","author":"Greenstein","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"R27-20260528","doi-asserted-by":"crossref","first-page":"e0083","DOI":"10.1097\/coa.0000000000000083","article-title":"Microbial keratitis after corneal allograft intrastromal ring segment implantation","volume":"5","author":"Kirat","year":"2026","journal-title":"Cornea Open"},{"key":"R29-20260528","doi-asserted-by":"crossref","first-page":"e1233","DOI":"10.3928\/1081597X-20250917-02","article-title":"Extracorporeal optimization of corneal allogenic intrastromal ring segments (ECO-CAIRS) using ultra-high-fluence corneal cross-linking","volume":"41","author":"Hafezi","year":"2025","journal-title":"J Refract Surg"},{"key":"R30-20260528","doi-asserted-by":"crossref","first-page":"5771","DOI":"10.3390\/jcm13195771","article-title":"Crosslinked all-femtosecond laser-cut corneal allogenic intracorneal ring segments (AFXL CAIRSs): pilot ex vivo study and report of first two cases performed in Italy","volume":"13","author":"Mazzotta","year":"2024","journal-title":"J Clin Med"},{"key":"R33-20260528","doi-asserted-by":"crossref","first-page":"193","DOI":"10.3390\/bioengineering13020193","article-title":"Beyond decellularization: remnant mitochondrial DNA can act as hidden damage-associated molecular pattern","volume":"13","author":"Van Hengel","year":"2026","journal-title":"Bioengineering (Basel)"},{"key":"R34-20260528","doi-asserted-by":"crossref","first-page":"e709","DOI":"10.3928\/1081597X-20250515-04","article-title":"Customized corneal allogeneic intrastromal ring segments (CAIRS) with corneal cross-linking for post-LASIK ectasia","volume":"41","author":"Jacob","year":"2025","journal-title":"J Refract Surg"},{"key":"R35-20260528","first-page":"e1","article-title":"Corneal allogenic intrastromal ring segment implantation for post-LASIK ectasia","volume":"3","author":"Kalas","year":"2023","journal-title":"J Refract Surg Case Rep"},{"key":"R36-20260528","doi-asserted-by":"crossref","first-page":"256","DOI":"10.3928\/1081597X-20220223-01","article-title":"Management of anterior stromal necrosis after polymethylmethacrylate ICRS: explantation versus exchange with corneal allogenic intrastromal ring segments","volume":"38","author":"Kozhaya","year":"2022","journal-title":"J Refract Surg"},{"key":"R37-20260528","doi-asserted-by":"crossref","first-page":"e1022","DOI":"10.3928\/1081597X-20250630-01","article-title":"Use of preexisting ICRS tunnels for implantation of CAIRS following ICRS migration and corneal tissue necrosis: a case report","volume":"41","author":"Alabbasi","year":"2025","journal-title":"J Refract Surg"},{"key":"R38-20260528","doi-asserted-by":"crossref","first-page":"102287","DOI":"10.1016\/j.ajoc.2025.102287","article-title":"The role of corneal allogenic intrastromal ring segments (CAIRS) implantation after failed synthetic intracorneal ring segments (ICRS): a rescuer","volume":"38","author":"AlQahtani","year":"2025","journal-title":"Am J Ophthalmol Case Rep"},{"key":"R39-20260528","first-page":"267","article-title":"Femtosecond laser-assisted customized CAIRS in keratoconus patients after ICRS explantation: a prospective case series: customized CAIRS in post ICRS extrusion keratoconus patients","volume":"51","author":"Susanna","year":"2024","journal-title":"J Cataract Refract Surg"},{"key":"R40-20260528","doi-asserted-by":"crossref","first-page":"13209","DOI":"10.1038\/s41598-026-43962-2","article-title":"Corneal allogenic intrastromal ring segments improve visual and topographic outcomes in advanced keratoconus","volume":"16","author":"Yesilirmak","year":"2026","journal-title":"Sci Rep"},{"key":"R41-20260528","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.ajo.2025.03.028","article-title":"Visual and topographic outcomes after corneal allogeneic intrastromal ring segments for keratoconus: a systematic review and meta-analysis","volume":"276","author":"Friedrich","year":"2025","journal-title":"Am J Ophthalmol"},{"key":"R42-20260528","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.3390\/jcm14041340","article-title":"Corneal allogenic intrastromal ring segments: a literature review","volume":"14","author":"Levy","year":"2025","journal-title":"J Clin Med"},{"key":"R43-20260528","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1097\/ICO.0000000000003831","article-title":"Six-month results of multiple femtosecond laser-assisted corneal allogeneic ring segments implantation: a case series","volume":"45","author":"Mechleb","year":"2026","journal-title":"Cornea"},{"key":"R44-20260528","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1097\/ICO.0000000000003751","article-title":"Femtosecond Laser-Assisted Graft Preparation and Implantation of Corneal Allogeneic Intrastromal Ring Segments for Corneal Ectasia: 1-Year Results","volume":"44","author":"Bteich","year":"2024","journal-title":"Cornea"},{"key":"R45-20260528","doi-asserted-by":"crossref","first-page":"e814","DOI":"10.3928\/1081597X-20250515-05","article-title":"Postoperative adjustment of implanted corneal allogeneic intrastromal ring segments (CAIRS) to improve visual and topographic outcomes","volume":"41","author":"Jacob","year":"2025","journal-title":"J Refract Surg"},{"key":"R46-20260528","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1097\/ICO.0000000000003851","article-title":"Anterior stromal melt with corneal allogeneic intrastromal ring segments in a patient with severe atopy","volume":"44","author":"Awwad","year":"2025","journal-title":"Cornea"}],"container-title":["Current Opinion in Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICU.0000000000001237","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T12:01:09Z","timestamp":1779969669000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICU.0000000000001237"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,14]]},"references-count":38,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/icu.0000000000001237","relation":{},"ISSN":["1040-8738","1531-7021"],"issn-type":[{"value":"1040-8738","type":"print"},{"value":"1531-7021","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,14]]}}}