{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T03:18:55Z","timestamp":1767842335612,"version":"3.49.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:sec>\n            <jats:title>Pr\u00e9cis:<\/jats:title>\n            <jats:p>Circumpapillary retinal nerve fiber layer (RNFL) thickness change induced by optical coherence tomography (OCT) scan circle location displacement was not completely compensated despite the use of Guided Progression Analysis (GPA), especially when the \u201cR1\u201d registration method was applied.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>The purpose of this study was to evaluate the effect of inconsistent OCT scan location on glaucoma progression detection using GPA.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Eighty-four glaucomatous eyes with at least 4 serial OCT tests were included. To evaluate the ability of OCT GPA to adjust the OCT scan location, an analysis was performed without manipulation (control set), and after the OCT scan of the latest test was intentionally moved inferotemporally (test set). The eyes were classified into the adjustment and nonadjustment groups based on the superior or inferior quadrant RNFL thickness agreement between the control and test sets.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>When the OCT GPA parameters between the control and test sets were compared, the test set showed a greater superior RNFL thickness and lesser inferior RNFL thickness compared with the control set (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.05). The eyes in the nonadjustment group (n=21, 25%) had a lower chance of applying the eye-tracking function (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.003) and a higher frequency of the \u201cR1\u201d registration method of OCT GPA (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.001) than the adjustment group (n=63, 75%); all eyes with the \u201cR1\u201d method were in the nonadjustment group and all eyes with the \u201cR2\u201d method were in the adjustment group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Inconsistent OCT scan location induced changes in RNFL thickness that were not completely compensated despite the use of OCT GPA, especially when the \u201cR1\u201d registration method was applied. These findings indicates a potential for misidentified glaucoma progression.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ijg.0000000000002000","type":"journal-article","created":{"date-parts":[[2022,2,18]],"date-time":"2022-02-18T16:03:42Z","timestamp":1645200222000},"page":"392-398","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Effect of Inconsistent Optical Coherence Tomography Scan Location on Glaucoma Progression Analysis"],"prefix":"10.1097","volume":"31","author":[{"given":"Young Hoon","family":"Hwang","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Chungnam National University Hospital, Daejeon"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mi Yeon","family":"Song","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kim\u2019s Eye Hospital, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2022,2,18]]},"reference":[{"key":"R1-20250803","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1016\/j.ophtha.2009.04.013","article-title":"Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study","volume":"116","author":"Leung","year":"2009","journal-title":"Ophthalmol"},{"key":"R2-20250803","first-page":"241.e1","article-title":"Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes","volume":"118","author":"Mwanza","year":"2011","journal-title":"Ophthalmol"},{"key":"R3-20250803","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.1016\/j.ophtha.2012.12.048","article-title":"Ability of cirrus high-definition spectral-domain optical coherence tomography clock-hour, deviation, and thickness maps in detecting photographic retinal nerve fiber layer abnormalities","volume":"120","author":"Hwang","year":"2013","journal-title":"Ophthalmol"},{"key":"R4-20250803","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/j.ophtha.2014.02.019","article-title":"Macular ganglion cell analysis for early detection of glaucoma","volume":"121","author":"Hwang","year":"2014","journal-title":"Ophthalmol"},{"key":"R5-20250803","doi-asserted-by":"crossref","first-page":"e526","DOI":"10.1097\/IJG.0000000000000385","article-title":"Repeatability of spectral domain optical coherence tomography measurements in high myopia","volume":"25","author":"Rao","year":"2016","journal-title":"J Glaucoma"},{"key":"R6-20250803","doi-asserted-by":"crossref","first-page":"11037","DOI":"10.1038\/s41598-018-29466-8","article-title":"Long-term reproducibility of GC-IPL thickness measurements using spectral domain optical coherence tomography in eyes with high myopia","volume":"8","author":"Lee","year":"2018","journal-title":"Sci Rep"},{"key":"R7-20250803","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1097\/IJG.0000000000001914","article-title":"Reproducibility of retinal nerve fiber layer and macular ganglion cell layer thickness measurements by optical coherence tomography in myopic eyes","volume":"30","author":"Park","year":"2021","journal-title":"J Glaucoma"},{"key":"R8-20250803","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.1136\/bjophthalmol-2012-301713","article-title":"Errors in neuroretinal rim measurement by Cirrus high-definition optical coherence tomography in myopic eyes","volume":"96","author":"Hwang","year":"2012","journal-title":"Br J Ophthalmol"},{"key":"R9-20250803","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1097\/IJG.0000000000000448","article-title":"Consistency of Bruch membrane opening detection as determined by optical coherence tomography","volume":"25","author":"Hwang","year":"2016","journal-title":"J Glaucoma"},{"key":"R10-20250803","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1159\/000221836","article-title":"The influence of eccentric scanning of optical coherence tomography on retinal nerve fiber layer analysis in normal subjects","volume":"223","author":"Yoo","year":"2009","journal-title":"Ophthalmol"},{"key":"R11-20250803","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.1038\/eye.2008.258","article-title":"Effects of scan circle displacement in optical coherence tomography retinal nerve fibre layer thickness measurement: a RNFL modelling study","volume":"23","author":"Cheung","year":"2009","journal-title":"Eye"},{"key":"R12-20250803","doi-asserted-by":"crossref","first-page":"2251","DOI":"10.1167\/iovs.13-13276","article-title":"Effect of motion artifacts and scan circle displacements on Cirrus HD-OCT retinal nerve fiber layer thickness measurements","volume":"55","author":"Taibbi","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R13-20250803","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1016\/j.ophtha.2016.02.017","article-title":"Risk of visual field progression in glaucoma patients with progressive retinal nerve fiber layer thinning: a 5-year prospective study","volume":"123","author":"Yu","year":"2016","journal-title":"Ophthalmol"},{"key":"R14-20250803","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1111\/cxo.12656","article-title":"Glaucomatous progression in the retinal nerve fibre and retinal ganglion cell-inner plexiform layers determined using optical coherence tomography-guided progression analysis","volume":"101","author":"Hwang","year":"2018","journal-title":"Clin Exp Optom"},{"key":"R15-20250803","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.ajo.2019.11.002","article-title":"Ganglion cell-inner plexiform layer and retinal nerve fiber layer changes in glaucoma suspects enable prediction of glaucoma development","volume":"210","author":"Shin","year":"2020","journal-title":"Am J Ophthalmol"},{"key":"R16-20250803","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.ophtha.2017.04.023","article-title":"Ganglion cell-inner plexiform layer change detected by optical coherence tomography indicates progression in advanced glaucoma","volume":"124","author":"Shin","year":"2017","journal-title":"Ophthalmol"},{"key":"R17-20250803","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1136\/bjophthalmol-2019-315715","article-title":"Effect of baseline test selection on glaucoma progression detection by optical coherence tomography-guided progression analysis","volume":"105","author":"Kang","year":"2021","journal-title":"Br J Ophthalmol"},{"key":"R18-20250803","doi-asserted-by":"crossref","first-page":"e214","DOI":"10.1097\/IJG.0000000000000250","article-title":"Retinal nerve fiber layer thickness measurement repeatability for Cirrus HD-OCT retinal tracking system during eye movement","volume":"25","author":"Hwang","year":"2016","journal-title":"J Glaucoma"},{"key":"R19-20250803","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.ajo.2004.08.076","article-title":"Optic disk ovality as an index of tilt and its relationship to myopia and perimetry","volume":"139","author":"Tay","year":"2005","journal-title":"Am J Ophthalmol"}],"container-title":["Journal of Glaucoma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IJG.0000000000002000","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,3]],"date-time":"2025-08-03T20:05:21Z","timestamp":1754251521000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IJG.0000000000002000"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,18]]},"references-count":19,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/ijg.0000000000002000","relation":{},"ISSN":["1057-0829"],"issn-type":[{"value":"1057-0829","type":"print"}],"subject":[],"published":{"date-parts":[[2022,2,18]]},"assertion":[{"value":"2021-11-30","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-01-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}