{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T00:02:06Z","timestamp":1755216126254,"version":"3.43.0"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:sec>\n            <jats:title>Abstract:<\/jats:title>\n            <jats:p>The Xen gel stent is a minimally invasive glaucoma surgical implant designed to decrease intraocular pressure (IOP) by creating an aqueous outflow path into the subconjunctival space. Since FDA approval, it has demonstrated good safety and efficacy data; however, there are multiple reports of Xen stent occlusions with debris from the anterior chamber. Herein, we report a case of a Descemet\u2019s membrane Xen stent occlusion in a 67-year-old woman with a past medical history of primary open angle glaucoma who underwent Xen stent placement through the ab externo approach. Her Descemet\u2019s membrane occlusion was successfully managed by Nd:YAG laser lysis. Although uncommon, small Descemet\u2019s tears or flaps can occlude the ostia of Xen stents causing elevated IOP or bleb failure. Few reports have described the use of Nd:YAG laser to successfully treat ostium occlusion of any kind with the Xen stent. We discuss the importance of early Nd:YAG laser to relieve Descemet\u2019s membrane occlusions, lower IOP, and rescue the bleb from failure.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ijg.0000000000002467","type":"journal-article","created":{"date-parts":[[2024,7,12]],"date-time":"2024-07-12T10:01:20Z","timestamp":1720778480000},"page":"e89-e91","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Occlusion of Xen Gel Stent With Descemet\u2019s Membrane Relieved by Nd:YAG Laser"],"prefix":"10.1097","volume":"33","author":[{"given":"Anne","family":"Strong Caldwell","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zafar S.","family":"Gill","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Deidre M.","family":"St. Peter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,7,15]]},"reference":[{"key":"R1-20250803","doi-asserted-by":"crossref","first-page":"773","DOI":"10.2147\/OPTH.S146919","article-title":"XEN glaucoma treatment system in the management of refractory glaucomas: a short review on trial data and potential role in clinical practice","volume":"12","author":"De Gregorio","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"R2-20250803","doi-asserted-by":"crossref","first-page":"25","DOI":"10.2147\/OPTH.S390955","article-title":"Intraocular pressure and medication changes associated with Xen gel stent: a systematic review of the literature","volume":"17","author":"Panarelli","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"R3-20250803","doi-asserted-by":"crossref","first-page":"804847","DOI":"10.3389\/fmed.2022.804847","article-title":"The outcomes of XEN gel stent implantation: a systematic review and meta-analysis","volume":"9","author":"Chen","year":"2022","journal-title":"Front Med"},{"key":"R4-20250803","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1007\/s10792-021-02069-5","article-title":"A retrospective review of XEN implant surgery: efficacy, safety and the effect of combined cataract surgery","volume":"42","author":"Nicolaou","year":"2022","journal-title":"Int Ophthalmol"},{"key":"R5-20250803","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1038\/s41433-023-02642-5","article-title":"Effectiveness and safety of XEN45 implant over 12 months of follow-up: data from the XEN-Glaucoma Treatment Registry","volume":"38","author":"Oddone","year":"2024","journal-title":"Eye"},{"key":"R6-20250803","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.2147\/OPTH.S405821","article-title":"Long-term effectiveness of XEN 45 gel-stent in open-angle glaucoma patients","volume":"17","author":"Marcos-Parra","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"R7-20250803","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1111\/ceo.13658","article-title":"Xen gel stent occlusion with iris pigment epithelium","volume":"48","author":"Eagle","year":"2020","journal-title":"Clin Exp Ophthalmol"},{"key":"R8-20250803","doi-asserted-by":"crossref","first-page":"e338","DOI":"10.1097\/IJG.0000000000001847","article-title":"Rescue of failed XEN-45 gel implant by Nd:YAG shock wave to anterior chamber tip to dislodge hidden intraluminal occlusion","volume":"30","author":"Fellman","year":"2021","journal-title":"J Glaucoma"},{"key":"R9-20250803","doi-asserted-by":"crossref","first-page":"113","DOI":"10.5005\/jp-journals-10078-1258","article-title":"Delayed obstruction of XEN gel stent by cell debris in primary open-angle glaucoma: a new insight into the pathophysiology of filtration device failure","volume":"13","author":"Gillmann","year":"2019","journal-title":"J Curr Glaucoma Pract"},{"key":"R10-20250803","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1097\/IJG.0000000000001002","article-title":"Chronic intraocular inflammation as a risk factor for XEN gel stent occlusion: a case of microscopic examination of a fibrin-obstructed Xen stent","volume":"27","author":"Gillmann","year":"2018","journal-title":"J Glaucoma"},{"key":"R11-20250803","doi-asserted-by":"crossref","first-page":"e150","DOI":"10.1097\/IJG.0000000000000625","article-title":"XEN gel stent internal ostium occlusion: ab-interno revision","volume":"26","author":"Pinto Ferreira","year":"2017","journal-title":"J Glaucoma"},{"key":"R12-20250803","doi-asserted-by":"crossref","first-page":"e91","DOI":"10.1097\/IJG.0000000000001589","article-title":"Laser iridoplasty to treat iris-occluded XEN gel stent","volume":"29","author":"Tadrosse","year":"2020","journal-title":"J Glaucoma"},{"key":"R13-20250803","doi-asserted-by":"crossref","first-page":"e26652","DOI":"10.1097\/MD.0000000000026652","article-title":"Combined argon laser peripheral iridoplasty and Nd: YAG laser shock wave therapy for recurrent XEN gel stent obstruction due to iris incarceration: a case report","volume":"100","author":"Rho","year":"2021","journal-title":"Medicine (Baltimore)"},{"key":"R14-20250803","first-page":"2936047","article-title":"Iris-occlusion of XEN gel stent following ab externo transconjunctival implantation technique","volume":"2021","author":"Ruparelia","year":"2021","journal-title":"Case Rep Ophthalmol Med"},{"key":"R15-20250803","doi-asserted-by":"crossref","first-page":"e77","DOI":"10.1097\/IJG.0000000000001194","article-title":"Postoperative complications of ab interno gelatin microstent","volume":"28","author":"Rooney","year":"2019","journal-title":"J Glaucoma"},{"key":"R16-20250803","doi-asserted-by":"crossref","first-page":"e71","DOI":"10.1097\/IJG.0000000000002208","article-title":"Short-term outcomes of Xen-45 gel stent ab interno versus ab externo transconjunctival approaches","volume":"32","author":"Yuan","year":"2023","journal-title":"J Glaucoma"},{"key":"R17-20250803","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/IJG.0000000000001423","article-title":"Neodymium laser treatment of IOP rise following ex-press glaucoma device implantation: a retrospective review from 4 institutions","volume":"29","author":"Mustafa","year":"2020","journal-title":"J Glaucoma"},{"key":"R18-20250803","doi-asserted-by":"crossref","first-page":"299","DOI":"10.2147\/OPTH.S292007","article-title":"Comparison of safety and efficacy between ab interno and ab externo approaches to XEN gel stent placement","volume":"15","author":"Tan","year":"2021","journal-title":"Clin Ophthalmol"}],"container-title":["Journal of Glaucoma"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IJG.0000000000002467","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,3]],"date-time":"2025-08-03T19:01:17Z","timestamp":1754247677000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IJG.0000000000002467"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,15]]},"references-count":18,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/ijg.0000000000002467","relation":{},"ISSN":["1057-0829","1536-481X"],"issn-type":[{"type":"print","value":"1057-0829"},{"type":"electronic","value":"1536-481X"}],"subject":[],"published":{"date-parts":[[2024,7,15]]},"assertion":[{"value":"2024-03-24","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-04","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}