{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T16:02:22Z","timestamp":1777737742804,"version":"3.51.4"},"reference-count":18,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2013,6,1]],"date-time":"2013-06-01T00:00:00Z","timestamp":1370044800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Innovations\ufffd(Phila)"],"published-print":{"date-parts":[[2013,6]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The aim of this study was to investigate the short-term and midterm outcome of the Engager transcatheter aortic valve implantation (TAVI) system, a transapical self-expanding valve device with anatomic orientation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Transapical aortic valve implantation with the Engager valve prosthesis was performed in 10 patients. Endpoints were defined according to the Valve Academic Research Consortium recommendations for reporting outcomes of TAVI in clinical trials. Follow-up has been completed after 30 days and 1 year.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>All patients underwent the implantation procedure successfully. No device-related or delivery system\u2013related complications were observed. One patient died of non\u2013device-related reasons at postoperative day 23 in multiorgan failure. At 30-day follow-up, no more than mild transvalvular and paravalvular aortic regurgitation were seen. After 1 year, no transvalvular regurgitation was observed as assessed by transthoracic echocardiography. None of the patients had more than mild paravalvular leakage. The mean \u00b1 SD gradient was 15.3 \u00b1 4.2 mm Hg. New York Heart Association class decreased one degree in mean and sustained until 1-year follow-up. No more patients died until 1-year follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Application of the Engager TAVI system is safe and reliable. Prosthesis deployment in an anatomically correct position was facilitated by the design of the valve prosthesis and successful in all patients. No device-related or delivery system\u2013related complications occurred. Procedural, short-term, and midterm results up to 1 year concerning the aortic valve performance are promising, with stable mean gradients and low rates of even mild regurgitation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/imi.0000000000000018","type":"journal-article","created":{"date-parts":[[2013,12,17]],"date-time":"2013-12-17T06:32:42Z","timestamp":1387261962000},"page":"332-336","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":5,"title":["Outcome of Patients Treated with Engager Transapical Aortic Valve Implantation"],"prefix":"10.1177","volume":"8","author":[{"given":"Simon H.","family":"S\u00fcndermann","sequence":"first","affiliation":[{"name":"Division of Cardiovascular Surgery, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00fcrg","family":"Gr\u00fcnenfelder","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Surgery, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roberto","family":"Corti","sequence":"additional","affiliation":[{"name":"Division of Cardiology, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ardawan J.","family":"Rastan","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Heart Center Leipzig, Leipzig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Axel","family":"Linke","sequence":"additional","affiliation":[{"name":"\u00a7Department of Cardiology, Heart Center Leipzig, Leipzig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R\u00fcdiger","family":"Lange","sequence":"additional","affiliation":[{"name":"\u2016Department of Cardiovascular Surgery, German Heart Centre Munich, Munich, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Volkmar","family":"Falk","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Surgery, University Hospital Zurich, Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabine","family":"Bleiziffer","sequence":"additional","affiliation":[{"name":"\u2016Department of Cardiovascular Surgery, German Heart Centre Munich, Munich, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2013,9,1]]},"reference":[{"key":"bibr1-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.001545"},{"key":"bibr2-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2011.01.078"},{"key":"bibr3-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezs129"},{"key":"bibr4-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehq445"},{"key":"bibr5-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezs389"},{"key":"bibr6-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehq406"},{"key":"bibr7-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.12.014"},{"key":"bibr8-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2008.06.059"},{"key":"bibr9-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21867"},{"key":"bibr10-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2012.03.004"},{"key":"bibr11-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2010.217158"},{"key":"bibr12-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1200384"},{"key":"bibr13-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2009.12.048"},{"key":"bibr14-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2008.01.046"},{"key":"bibr15-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2011.01.059"},{"key":"bibr16-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2010.11.044"},{"key":"bibr17-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.108.837807"},{"key":"bibr18-imi.0000000000000018","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezs139"}],"container-title":["Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/imi.0000000000000018","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/imi.0000000000000018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T11:20:20Z","timestamp":1777461620000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1097\/imi.0000000000000018"}},"subtitle":["One-Year Results of the Feasibility Study"],"short-title":[],"issued":{"date-parts":[[2013,6]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2013,6]]}},"alternative-id":["10.1097\/imi.0000000000000018"],"URL":"https:\/\/doi.org\/10.1097\/imi.0000000000000018","relation":{},"ISSN":["1556-9845","1559-0879"],"issn-type":[{"value":"1556-9845","type":"print"},{"value":"1559-0879","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,6]]}}}