{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T15:39:23Z","timestamp":1777736363493,"version":"3.51.4"},"reference-count":22,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Innovations\ufffd(Phila)"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>\n                      Morbidity due to sternotomy continues to be a significant clinical problem. Poor approximation of the sternum may lead to complications such as sternal dehiscence, infection, and pain. A device to assist in tensioning and twisting standard steel wires during sternal closure has been developed (TORQ\n                      <jats:sup>TM<\/jats:sup>\n                      sternal closure device). Manually tightened interrupted wire closures were compared with those tightened and secured with the aid of the device. Performance of the device was assessed clinically.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Four cardiovascular surgeons performed manual and device-assisted closures on a biofidelic model. Closure force was measured to determine the residual force and its intraoperator variation. A retrospective review of patients treated before and after the introduction of the device was conducted. Predicted and actual outcomes were compared for the two groups (manual closure and deviceassisted closure).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Biomechanical testing measured a 75% increase in residual closure force ( P &lt; 0.001) and a significant reduction in the variability of the closure force ( P = 0.045) for device-assisted closures compared with manual closures. In the retrospective study, 3 of 173 manually closed patients had sterile sternal dehiscence and 1 of 173 had a deep sternal wound infection. In the device closure group, 2 of 127 had a sterile sternal dehiscence and no deep sternal wound infections were reported. No other device-related serious adverse events were reported.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Biomechanical data showed stronger, more consistent closure forces with the device. The retrospective data attest to the performance of the device.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/imi.0000000000000425","type":"journal-article","created":{"date-parts":[[2018,1,5]],"date-time":"2018-01-05T17:39:34Z","timestamp":1515173974000},"page":"40-46","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["A New Device for Securing Sternal Wires after Median Sternotomy"],"prefix":"10.1177","volume":"13","author":[{"given":"Matthew R.","family":"Danter","sequence":"first","affiliation":[{"name":"Department of Cardiac and Thoracic Surgery, Vanderbilt University Medical Center, Nashville, TN USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amy","family":"Saari","sequence":"additional","affiliation":[{"name":"Kardium, Inc, Burnaby, BC Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Min","family":"Gao","sequence":"additional","affiliation":[{"name":"Providence Health Care Research Institute, Vancouver, BC Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anson","family":"Cheung","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Surgery, St. Paul's Hospital, Vancouver, BC Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel V.","family":"Lichtenstein","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Surgery, St. Paul's Hospital, Vancouver, BC Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James G.","family":"Abel","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Surgery, St. Paul's Hospital, Vancouver, BC Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,1,1]]},"reference":[{"key":"bibr1-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2006.04.058"},{"key":"bibr2-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.03.038"},{"key":"bibr3-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1988.01400270126021"},{"key":"bibr4-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(10)62920-7"},{"key":"bibr5-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.3109\/14017438309099365"},{"key":"bibr6-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(10)60767-9"},{"key":"bibr7-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(99)00014-7"},{"key":"bibr8-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2006.03.015"},{"key":"bibr9-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(10)62035-8"},{"key":"bibr10-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(19)39957-X"},{"key":"bibr11-imi.0000000000000425","first-page":"512","volume":"27","author":"Goodman F.","year":"1986","journal-title":"J Cardiovasc Surg (Torino)."},{"key":"bibr12-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2004.07.043"},{"key":"bibr13-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(96)00025-2"},{"key":"bibr14-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2004.04.038"},{"key":"bibr15-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.01.089"},{"key":"bibr16-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2011.05.014"},{"key":"bibr17-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.07.005"},{"key":"bibr18-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/S0268-0033(98)00005-9"},{"key":"bibr19-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(99)70251-5"},{"key":"bibr20-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.29.2.351"},{"key":"bibr21-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.102.12.1375"},{"key":"bibr22-imi.0000000000000425","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.165.21.2486"}],"container-title":["Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/imi.0000000000000425","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/imi.0000000000000425","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T11:16:07Z","timestamp":1777461367000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1097\/imi.0000000000000425"}},"subtitle":["Biomechanical Study and Retrospective Clinical Assessment"],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["10.1097\/imi.0000000000000425"],"URL":"https:\/\/doi.org\/10.1097\/imi.0000000000000425","relation":{},"ISSN":["1556-9845","1559-0879"],"issn-type":[{"value":"1556-9845","type":"print"},{"value":"1559-0879","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1]]}}}