{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T15:39:38Z","timestamp":1777736378592,"version":"3.51.4"},"reference-count":12,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Innovations\ufffd(Phila)"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Recently, the PARTNER 2A trial reported results of transcatheter aortic valve replacement versus surgical aortic valve replacement in 2032 intermediate-risk patients at 2 years. Two hundred thirty-six patients (24%) required an access route other than transfemoral. Compared with transfemoral and surgical aortic valve replacement, nontransfemoral transcatheter aortic valve replacement was associated with a numerically higher rate of death and disabling stroke at 30 days. This underscores the need for a better alternative surgical approach for patients with marginal femoral access. We reviewed our multicenter experience with minimally invasive suprasternal transcatheter aortic valve replacement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Consecutive patients with symptomatic severe aortic stenosis at high or intermediate risk for surgical aortic valve replacement underwent suprasternal transcatheter aortic valve replacement. A commercially available transcatheter heart valve was deployed under fluoroscopic guidance through the innominate artery or ascending aorta. Using a 3-cm skin incision just above the sternal notch, the Aegis Transit System (Aegis Surgical Ltd, Galway, Ireland) provided illuminated access to the mediastinum without bone disruption. Through a purse-string suture placed in the innominate artery or ascending aorta, transcatheter aortic valve replacement proceeded similarly to the direct aortic approach.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Thirty patients at six medical centers successfully underwent suprasternal transcatheter aortic valve replacement. Implanted valves included 2 CoreValve and 12 Evolut-R (Medtronic, Inc, Minneapolis, MN USA), as well as 10 SAPIEN 3 and 6 SAPIEN XT (Edwards Lifesciences, Corp, Irvine, CA USA) with sizes ranging from 23 to 31 mm. Median procedure time was 90 minutes and median hospital stay was 4 days. Postoperatively, new permanent pacemaker (n = 3) was the most common Vascular Academic Research Consortium 2 complication.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>These data demonstrate the early clinical feasibility of suprasternal transcatheter aortic valve replacement. Key advantages of this approach include direct access to the innominate artery and ascending aorta, precise sheath control, and confident arterial closure. Additional experience is warranted to confirm these favorable results.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/imi.0000000000000462","type":"journal-article","created":{"date-parts":[[2018,2,16]],"date-time":"2018-02-16T16:32:47Z","timestamp":1518798767000},"page":"1-4","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["Suprasternal Transcatheter Aortic Valve Replacement in Patients with Marginal Femoral Access"],"prefix":"10.1177","volume":"13","author":[{"given":"Andy C.","family":"Kiser","sequence":"first","affiliation":[{"name":"East Carolina Heart Institute, East Carolina University, Greenville, NC USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas G.","family":"Caranasos","sequence":"additional","affiliation":[{"name":"Department of Surgery, University of North Carolina School of Medicine, Chapel Hill, NC USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark D.","family":"Peterson","sequence":"additional","affiliation":[{"name":"St. Michael's Hospital, University of Toronto, Toronto, ON Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David M.","family":"Holzhey","sequence":"additional","affiliation":[{"name":"University of Leipzig Heart Center, Leipzig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Kiefer","sequence":"additional","affiliation":[{"name":"University of Leipzig Heart Center, Leipzig, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Wiley Nifong","sequence":"additional","affiliation":[{"name":"East Carolina Heart Institute, East Carolina University, Greenville, NC USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael A.","family":"Borger","sequence":"additional","affiliation":[{"name":"Division of Cardiothoracic Surgery, New York-Presbyterian Hospital, Columbia University, New York, NY USA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,1,1]]},"reference":[{"key":"bibr1-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1514616"},{"key":"bibr2-imi.0000000000000462","unstructured":"Supplement to: LeonM.B., SmithC.R., MackM.J. Transcatheter or surgical aortic-valve replacement in inter-mediate-risk patients. Available at: http:\/\/www.nejm.org\/action\/showSupplements?doi=10.1056%2FNEJMoa1514616. Accessed April 28, 2016."},{"key":"bibr3-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2011.10.056"},{"key":"bibr4-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1053\/j.semtcvs.2014.10.001"},{"key":"bibr5-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2014.02.049"},{"key":"bibr6-imi.0000000000000462","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/S1052-3359(25)00234-0","volume":"6","author":"Ginsberg R.J.","year":"1996","journal-title":"Chest Surg Clin N Am."},{"key":"bibr7-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezu524"},{"key":"bibr8-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2017.04.032"},{"key":"bibr9-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.02.076"},{"key":"bibr10-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1093\/ehjci\/jeu103"},{"key":"bibr11-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2012.11.003"},{"key":"bibr12-imi.0000000000000462","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(03)12978-9"}],"container-title":["Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/imi.0000000000000462","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/imi.0000000000000462","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T11:16:09Z","timestamp":1777461369000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1097\/imi.0000000000000462"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":12,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["10.1097\/imi.0000000000000462"],"URL":"https:\/\/doi.org\/10.1097\/imi.0000000000000462","relation":{},"ISSN":["1556-9845","1559-0879"],"issn-type":[{"value":"1556-9845","type":"print"},{"value":"1559-0879","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1]]}}}