{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T15:42:37Z","timestamp":1777736557349,"version":"3.51.4"},"reference-count":27,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Innovations\ufffd(Phila)"],"published-print":{"date-parts":[[2018,9]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The aim of this retrospective, single-center study was to evaluate the occurrence of conduction disorders after rapid deployment aortic bioprosthesis implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Electrocardiograms of patients undergoing INTUITY (Edwards Lifesciences, Irvine, CA USA) bioprosthesis implantation were collected at admission, during postoperative course, and at discharge. Primary end point was the occurrence of new-onset conduction disorders, defined as complete left bundle branch block, complete right bundle branch block, permanent pacemaker implantation, and worsening of pre-existing rhythm abnormalities. Secondary end points were the assessment of preoperative and postoperative QRS duration and the identification of transitory conduction disorders.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Forty-four patients (July 2015\u2013December 2016) were included in the analysis. Preoperatively, patients with normal conduction and with already existing disorders were 25 (56.8%) and 19 (43.2%), respectively. Primary end point occurred in 14 patients (31.8%). Two patients (4.5%) received pacemaker implantation. In patients with normal preoperative conduction, new abnormalities were found in eight cases (32%): all left bundle branch blocks with one pacemaker implantation. Worsening of pre-existing conduction disorders was found in six patients (31.6%) with one pacemaker implantation. QRS duration increased in 20 patients (45.4%), and average increase was 37 milliseconds. Overall, we observed a significant increase of QRS (96 \u00b1 21 milliseconds vs. 111 \u00b1 28 milliseconds, P &lt; 0.001). Three patients experienced a new-onset temporary left bundle branch block.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>New-onset conduction disorders or worsening of pre-existing rhythm abnormalities occur in one third of patients after rapid deployment aortic bioprosthesis implantation. Although the incidence of postoperative pacemaker implantation before discharge is low, strict follow-up is mandatory to identify a potential need for pacemaker implantation in a timely manner.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/imi.0000000000000558","type":"journal-article","created":{"date-parts":[[2018,11,3]],"date-time":"2018-11-03T02:31:08Z","timestamp":1541212268000},"page":"356-360","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":8,"title":["Evaluation of Conduction Disorders after Aortic Valve Replacement                     with Rapid Deployment Bioprostheses"],"prefix":"10.1177","volume":"13","author":[{"given":"Augusto","family":"D'Onofrio","sequence":"first","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenzo","family":"Bagozzi","sequence":"additional","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chiara","family":"Tessari","sequence":"additional","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annalisa","family":"Francescato","sequence":"additional","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giorgia","family":"Cibin","sequence":"additional","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Besola","sequence":"additional","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rita","family":"Pesce","sequence":"additional","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giuseppe","family":"Toscano","sequence":"additional","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gino","family":"Gerosa","sequence":"additional","affiliation":[{"name":"From the Division of Cardiac Surgery, University of\r                Padova, Padova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,9,1]]},"reference":[{"key":"bibr1-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12569"},{"key":"bibr2-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2015-307666"},{"key":"bibr3-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.113.005479"},{"key":"bibr4-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2013.08.001"},{"key":"bibr5-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2010.10.054"},{"key":"bibr6-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2009.05.029"},{"key":"bibr7-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2012.07.108"},{"key":"bibr8-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2016.09.062"},{"key":"bibr9-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.12.013"},{"key":"bibr10-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.02.032"},{"key":"bibr11-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2014.07.049"},{"key":"bibr12-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezx103"},{"key":"bibr13-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1510\/icvts.2010.249904"},{"key":"bibr14-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2011.02211.x"},{"key":"bibr15-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.04.033"},{"key":"bibr16-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1510\/icvts.2010.256578"},{"key":"bibr17-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2014.07.022"},{"key":"bibr18-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1103510"},{"key":"bibr19-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.ancard.2016.09.003"},{"key":"bibr20-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1114705"},{"key":"bibr21-IMI.0000000000000558","doi-asserted-by":"crossref","first-page":"E569","DOI":"10.1002\/ccd.24915","volume":"82","author":"Ledwoch J","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"bibr22-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.21037\/jtd.2017.03.24"},{"key":"bibr23-IMI.0000000000000558","first-page":"319","volume":"23","author":"Van Boxtel AG","year":"2014","journal-title":"J Heart Valve Dis"},{"key":"bibr24-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.07.035"},{"key":"bibr25-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1093\/icvts\/ivx050"},{"key":"bibr26-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.4244\/EIJ30V6I4A80"},{"key":"bibr27-IMI.0000000000000558","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24657"}],"container-title":["Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/IMI.0000000000000558","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/IMI.0000000000000558","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T11:16:31Z","timestamp":1777461391000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1097\/IMI.0000000000000558"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,9]]}},"alternative-id":["10.1097\/IMI.0000000000000558"],"URL":"https:\/\/doi.org\/10.1097\/imi.0000000000000558","relation":{},"ISSN":["1556-9845","1559-0879"],"issn-type":[{"value":"1556-9845","type":"print"},{"value":"1559-0879","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9]]}}}