{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T15:56:05Z","timestamp":1777737365486,"version":"3.51.4"},"reference-count":8,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2010,7,1]],"date-time":"2010-07-01T00:00:00Z","timestamp":1277942400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Innovations\ufffd(Phila)"],"published-print":{"date-parts":[[2010,7]]},"abstract":"<jats:p>Because the use of percutaneous intervention is increasing for the closure of the patent ductus arteriosus, the procedure-related complications are also on rise, with migration of the device being most common. The routine practice is to remove the migrated duct occluder device under cardiopulmonary bypass. Amplatzer duct occluder used in a 4-month-old infant dislodged into the descending thoracic aorta. It was removed by the posterolateral thoracotomy under mild hypothermia through juxtaductal aortotomy between the aortic cross-clamps. The use of cardiopulmonary bypass is thus avoided.<\/jats:p>","DOI":"10.1097\/imi.0b013e3181f01fa1","type":"journal-article","created":{"date-parts":[[2010,8,25]],"date-time":"2010-08-25T03:31:00Z","timestamp":1282707060000},"page":"311-312","source":"Crossref","is-referenced-by-count":0,"title":["Surgical Removal of Duct Occluder Device under Mild Hypothermia without Cardiopulmonary Bypass"],"prefix":"10.1177","volume":"5","author":[{"given":"Prashant N.","family":"Mohite","sequence":"first","affiliation":[{"name":"Departments of Cardiovascular and Thoracic Surgery, Chandigarh, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sachin A.","family":"Kuthe","sequence":"additional","affiliation":[{"name":"Departments of Cardiovascular and Thoracic Surgery, Chandigarh, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shyam K.","family":"Thingnam","sequence":"additional","affiliation":[{"name":"Departments of Cardiovascular and Thoracic Surgery, Chandigarh, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manoj K.","family":"Rohit","sequence":"additional","affiliation":[{"name":"Cardiology, Postgraduation Institute of Medical Research and Education, Chandigarh, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sachin","family":"Mahajan","sequence":"additional","affiliation":[{"name":"Departments of Cardiovascular and Thoracic Surgery, Chandigarh, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rajiv","family":"Mahajan","sequence":"additional","affiliation":[{"name":"Cardiology, Postgraduation Institute of Medical Research and Education, Chandigarh, India."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2010,7,1]]},"reference":[{"key":"bibr1-imi.0b013e3181f01fa1","first-page":"469","volume":"63","author":"Jatene F.B.","year":"1994","journal-title":"Arq Bras Cardiol."},{"key":"bibr2-imi.0b013e3181f01fa1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.97.6.609"},{"key":"bibr3-imi.0b013e3181f01fa1","first-page":"114","volume":"79","author":"Parra-Bravo J.R.","year":"2009","journal-title":"Arch Cardiol Mex."},{"key":"bibr4-imi.0b013e3181f01fa1","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-8932(09)72069-X"},{"key":"bibr5-imi.0b013e3181f01fa1","doi-asserted-by":"publisher","DOI":"10.1053\/euhj.2001.2605"},{"key":"bibr6-imi.0b013e3181f01fa1","first-page":"80","volume":"83","author":"Atik F.A.","year":"2004","journal-title":"Arq Bras Cardiol."},{"key":"bibr7-imi.0b013e3181f01fa1","doi-asserted-by":"publisher","DOI":"10.1510\/icvts.2007.152298"},{"key":"bibr8-imi.0b013e3181f01fa1","doi-asserted-by":"publisher","DOI":"10.1510\/icvts.2008.201152"}],"container-title":["Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/imi.0b013e3181f01fa1","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/imi.0b013e3181f01fa1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T11:19:22Z","timestamp":1777461562000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1097\/imi.0b013e3181f01fa1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7]]},"references-count":8,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2010,7]]}},"alternative-id":["10.1097\/imi.0b013e3181f01fa1"],"URL":"https:\/\/doi.org\/10.1097\/imi.0b013e3181f01fa1","relation":{},"ISSN":["1556-9845","1559-0879"],"issn-type":[{"value":"1556-9845","type":"print"},{"value":"1559-0879","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,7]]}}}