{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T07:50:21Z","timestamp":1758268221349},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012,11]]},"DOI":"10.1097\/iop.0b013e318261169a","type":"journal-article","created":{"date-parts":[[2012,11,8]],"date-time":"2012-11-08T08:59:03Z","timestamp":1352365143000},"page":"401-404","source":"Crossref","is-referenced-by-count":6,"title":["A Comparison of Surgical Outcomes With the Use of 2 Different Biodegradable Multipoint Fixation Devices for Endoscopic Forehead Elevation"],"prefix":"10.1097","volume":"28","author":[{"given":"J. Javier","family":"Servat","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Evan H.","family":"Black","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-4-20210129","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1016\/j.asj.2008.07.013","article-title":"Preliminary evaluation of a fast-absorbing multipoint fixation device.","volume":"28","author":"Berkowitz","year":"2008","journal-title":"Aesthet Surg J"},{"key":"R2-4-20210129","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1001\/archfaci.9.3.212","article-title":"Efficacy and safety of endotine fixation device in endoscopic brow-lift.","volume":"9","author":"Byrne","year":"2007","journal-title":"Arch Facial Plast Surg"},{"key":"R3-4-20210129","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1001\/archfaci.10.4.280","article-title":"Multispecialty contralateral study of clinical experience with the Ultratine forehead fixation device: evolution of the original Endotine device.","volume":"10","author":"Apfelberg","year":"2008","journal-title":"Arch Facial Plast Surg"},{"key":"R6-4-20210129","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1302\/0301-620X.74B6.1332975","article-title":"Osteolysis after biodegradable pin fixation of fractures in children.","volume":"74","author":"Fraser","year":"1992","journal-title":"J Bone Joint Surg Br"},{"key":"R7-4-20210129","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1302\/0301-620X.74B6.1332974","article-title":"Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial.","volume":"74","author":"Casteleyn","year":"1992","journal-title":"J Bone Joint Surg Br"},{"key":"R8-4-20210129","first-page":"78","article-title":"Biodegradable fixation in intraarticulate fractures of the elbow joint.","volume":"227","author":"Hirvensalo","year":"1988","journal-title":"Acta Orthop Scand Suppl"},{"key":"R9-4-20210129","doi-asserted-by":"crossref","first-page":"189","DOI":"10.7547\/87507315-82-4-189","article-title":"Effectiveness of absorbable fixation devices in Austin bunionectomies.","volume":"82","author":"Gerbert","year":"1992","journal-title":"J Am Podiatr Med Assoc"},{"key":"R10-4-20210129","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1177\/107110079101100405","article-title":"Chevron osteotomy fixed with absorbable polyglycolide pins.","volume":"11","author":"Hirvensalo","year":"1991","journal-title":"Foot Ankle"},{"key":"R13-4-20210129","doi-asserted-by":"crossref","first-page":"1942","DOI":"10.1097\/01.PRS.0000055045.08656.D0","article-title":"The temporal sequence of periosteal attachment after elevation.","volume":"111","author":"Boutros","year":"2003","journal-title":"Plast Reconstr Surg"},{"key":"R14-4-20210129","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1097\/00006534-199509000-00007","article-title":"A study of the supraorbital nerve.","volume":"96","author":"Knize","year":"1995","journal-title":"Plast Reconstr Surg"},{"key":"R17-4-20210129","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1097\/IOP.0b013e3181b8c3c5","article-title":"Ultratine retention: report of a case.","volume":"25","author":"Savar","year":"2009","journal-title":"Ophthal Plast Reconstr Surg"}],"container-title":["Ophthalmic Plastic &amp; Reconstructive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IOP.0b013e318261169a","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,14]],"date-time":"2021-05-14T01:51:04Z","timestamp":1620957064000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00002341-201211000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11]]},"references-count":11,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.1097\/iop.0b013e318261169a","relation":{},"ISSN":["0740-9303"],"issn-type":[{"value":"0740-9303","type":"print"}],"subject":[],"published":{"date-parts":[[2012,11]]}}}