{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,17]],"date-time":"2025-05-17T04:13:16Z","timestamp":1747455196343,"version":"3.40.5"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Cataract Refract Surg"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To compare incision size enlargement at different times of cataract surgery and visual outcomes after surgery in 2 different intraocular lens (IOL) delivery systems (Vivinex iSert and UltraSert Preloaded IOL Delivery System).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Tertiary care eye institution.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective nonrandomized comparison study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>All eyes had uneventful temporal clear corneal phacoemulsification cataract surgery. The surgery was done by standard direct horizontal chop with a bimanual irrigation aspiration of the cortex. The primary incision size was measured after clear corneal incision, after the completion of phacoemulsification, and after IOL implantation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The study comprised 276 eyes of 220 patients. The mean initial corneal incision was similar in both groups (2.2 mm). There was no significant difference in the mean incision size after phacoemulsification between the 2 groups (2.250 mm \u00b1 0.068 mm [SD] vs 2.251 \u00b1 0.066 mm [SD], <jats:italic toggle=\"yes\">P<\/jats:italic> &gt; .99). There was no significant difference in the mean (SD) incision size after IOL insertion between the 2 groups (2.367 \u00b1 0.066 mm vs 2.369 \u00b1 0.062 mm [SD], <jats:italic toggle=\"yes\">P<\/jats:italic> = .815. The corrected distance visual acuity was 6\/6 at 1 month in 80% of the participants in the UltraSert group and 86% in the Vivinex group. After adjusting for age, sex, grade of cataract, and IOL power, no significant difference was found in the magnitude of surgically induced astigmatism (SIA) in the Vivinex group compared with the UltraSert group (0.06, 95% CI, \u22120.11 to 0.24; <jats:italic toggle=\"yes\">P<\/jats:italic> = .47).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>No significant difference was found in the change in the incision size, visual acuity, and SIA between UltraSert and Vivinex IOL delivery systems. This suggests that both IOL delivery systems are comparable in terms of post-IOL delivery incision enlargement for incisions of 2.2 mm.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/j.jcrs.0000000000000014","type":"journal-article","created":{"date-parts":[[2020,1,24]],"date-time":"2020-01-24T18:47:10Z","timestamp":1579891630000},"page":"222-227","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Incision size changes after cataract surgery with intraocular lens implantation: comparison of 2 preloaded IOL implantation injectors"],"prefix":"10.1097","volume":"46","author":[{"given":"Suhas S.","family":"Haldipurkar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vijay","family":"Shetty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tanvi","family":"Haldipurkar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rita","family":"Dhamankar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nancy","family":"Sehdev","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zain","family":"Khatib","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pranoti","family":"Nagvekar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paresh","family":"Mhatre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maninder Singh","family":"Setia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250516","doi-asserted-by":"crossref","first-page":"1549","DOI":"10.1016\/j.jcrs.2014.07.006","article-title":"Microincisions in cataract surgery","volume":"40","author":"Dewey","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R2-20250516","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1016\/S0886-3350(13)80613-X","article-title":"Effect of incision size on early postoperative visual rehabilitation after cataract surgery and intraocular lens implantation","volume":"19","author":"el-Maghraby","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R3-20250516","doi-asserted-by":"crossref","first-page":"2115","DOI":"10.1016\/j.jcrs.2009.06.037","article-title":"Incision sizes at different stages of phacoemulsification with foldable intraocular lens implantation","volume":"35","author":"Espiritu","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R4-20250516","doi-asserted-by":"crossref","first-page":"1675","DOI":"10.1016\/j.jcrs.2013.04.039","article-title":"Final incision size after cataract surgery with toric intraocular lens implantation using 2 techniques","volume":"39","author":"Guarnieri","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R5-20250516","doi-asserted-by":"crossref","first-page":"1748","DOI":"10.1016\/j.jcrs.2008.06.031","article-title":"Incision sizes before and after implantation of SN60WF intraocular lenses using the Monarch injector system with C and D cartridges","volume":"34","author":"Kohnen","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250516","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.jcrs.2011.08.038","article-title":"Final incision size after implantation of a hydrophobic acrylic aspheric intraocular lens: new motorized injector versus standard manual injector","volume":"38","author":"Allen","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R7-20250516","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1016\/j.jcrs.2018.10.047","article-title":"Variations in intraocular lens injector dimensions and corneal incision architecture after cataract surgery","volume":"45","author":"Arboleda","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R8-20250516","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/s10792-018-0825-2","article-title":"Corneal incision architecture after IOL implantation with three different injectors: an environmental scanning electron microscopy study","volume":"39","author":"Mencucci","year":"2019","journal-title":"Int Ophthalmol"},{"key":"R9-20250516","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1016\/j.jcrs.2017.02.019","article-title":"Evaluation of preloaded intraocular lens injection systems: ex vivo study","volume":"43","author":"Nanavaty","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250516","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.jcrs.2018.10.050","article-title":"In vitro comparison of delivery performance of 4 preloaded intraocular lens injector systems for corneal and sclerocorneal incisions","volume":"45","author":"Oshika","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R11-20250516","doi-asserted-by":"crossref","first-page":"1814","DOI":"10.1016\/j.jcrs.2016.10.014","article-title":"In vitro delivery performance assessment of a new preloaded intraocular lens delivery system","volume":"42","author":"Wang","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R12-20250516","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1007\/s00347-008-1718-y","article-title":"Aspheric intraocular lenses [in German]","volume":"105","author":"Kohnen","year":"2008","journal-title":"Ophthalmologe"},{"key":"R13-20250516","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.ophtha.2004.06.030","article-title":"Incision sizes before and after implantation of 6-mm optic foldable intraocular lenses using Monarch and Unfolder injector systems","volume":"112","author":"Kohnen","year":"2005","journal-title":"Ophthalmology"},{"key":"R14-20250516","first-page":"1123","article-title":"The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery","volume":"10","author":"Jones","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"R15-20250516","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1136\/bjo.87.7.867","article-title":"A 10 year retrospective survey of cataract surgery and endophthalmitis in a single eye unit: injectable lenses lower the incidence of endophthalmitis","volume":"87","author":"Mayer","year":"2003","journal-title":"Br J Ophthalmol"},{"key":"R16-20250516","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1136\/bjophthalmol-2014-306372","article-title":"An 8-year retrospective study of cataract surgery and postoperative endophthalmitis: injectable intraocular lenses may reduce the incidence of postoperative endophthalmitis","volume":"99","author":"Weston","year":"2015","journal-title":"Br J Ophthalmol"},{"key":"R17-20250516","doi-asserted-by":"crossref","first-page":"9","DOI":"10.4103\/0301-4738.44491","article-title":"Wound construction in manual small incision cataract surgery","volume":"57","author":"Haldipurkar","year":"2009","journal-title":"Indian J Ophthalmol"},{"key":"R18-20250516","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1016\/j.jcrs.2003.11.034","article-title":"Surgically induced astigmatism after superotemporal and superonasal clear corneal incisions in phacoemulsification","volume":"30","author":"Ermis","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R19-20250516","first-page":"314","article-title":"Evaluation of surgically induced astigmatism after coaxial phacoemulsification through 1.8 mm microincision and standard phacoemulsification through 2.75 mm incision","volume":"113","author":"Wilczynski","year":"2011","journal-title":"Klin Oczna"},{"key":"R20-20250516","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3341\/kjo.2007.21.1.1","article-title":"Comparison of surgically induced astigmatisms after clear corneal incisions of different sizes","volume":"21","author":"Moon","year":"2007","journal-title":"Korean J Ophthalmol"},{"key":"R21-20250516","first-page":"1004","article-title":"Comparison of surgically induced astigmatism among different surgeons performing the same incision","volume":"10","author":"Theodoulidou","year":"2017","journal-title":"Int J Ophthalmol"},{"key":"R22-20250516","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.jfma.2011.03.002","article-title":"The influence of corneal wound size on surgically induced corneal astigmatism after phacoemulsification","volume":"111","author":"Wei","year":"2012","journal-title":"J Formos Med Assoc"},{"key":"R23-20250516","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.ajo.2014.03.001","article-title":"Intraocular lens injector-induced stress on the corneal incisions during lens implantation","volume":"158","author":"Kleinmann","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R24-20250516","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1016\/j.jcrs.2015.03.018","article-title":"Resistance force for intraocular lens insertion through lens cartridges and syringe-type injectors","volume":"41","author":"Usui","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R25-20250516","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1016\/j.jcrs.2012.11.018","article-title":"Incision integrity and postoperative outcomes after microcoaxial phacoemulsification performed using 2 incision-dependent systems","volume":"39","author":"Vasavada","year":"2013","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Cataract &amp; Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,16]],"date-time":"2025-05-16T19:00:58Z","timestamp":1747422058000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000014","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"type":"print","value":"0886-3350"},{"type":"electronic","value":"1873-4502"}],"subject":[],"published":{"date-parts":[[2020,2]]},"assertion":[{"value":"2019-04-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-09-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}