{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T12:12:25Z","timestamp":1793880745652,"version":"4.7.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Cataract Refract Surg","Journal of Cataract and Refractive Surgery"],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To report the initial experience with a new presbyopic phakic intraocular lens (pIOL) in the correction of high myopia and presbyopia.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Gemini Eye Clinic, Zlin, Czech Republic.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective cohort study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Presbyopic eyes with moderate to high myopia were implanted with a presbyopic posterior chamber pIOL (IPCL). The visual acuities at near and distance, endothelial cell density, and ocular condition were examined 1 week, 3 months, 1 year and 2 years postoperatively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The mean uncorrected distance visual acuity improved significantly from 1.25 logarithm of the minimum angle of resolution (logMAR) (1.15 to 1.35 95% confidence interval [CI]) to 0.11 logMAR (95% CI, 0.03 to 0.17) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .0001). No eye lost 1 or more lines of corrected distance visual acuity. The mean distance refraction improved significantly from \u22126.9 diopters (D) (range \u22128.6 to \u22125.3 D) preoperatively to \u22120.35 D (range \u22120.55 to \u22120.15 D, <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .0001) with less than \u22120.5 D residual refraction in 11 of 17 eyes. Fifteen of 17 eyes had improved uncorrected near visual acuity to J1 (Jaeger chart) at the 2-year follow-up. The near addition at the 2-year follow-up decreased from preoperatively +1.26 D (range 0.19 to 2.34 D) to +0.39 D (range 0.18 to 0.60 D). The mean endothelial cell density was reduced from 2552 cells\/mm<jats:sup>2<\/jats:sup> (range 2421 to 2682 cells\/mm<jats:sup>2<\/jats:sup>) to 2299 cells\/mm<jats:sup>2<\/jats:sup> (range 2108 to 2490 cells\/mm<jats:sup>2<\/jats:sup>) after 2 years. All patients were subjectively satisfied with the outcomes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The new pIOL provided good visual outcomes in near and far distances in an initial case series of patients.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/j.jcrs.0000000000000033","type":"journal-article","created":{"date-parts":[[2020,1,16]],"date-time":"2020-01-16T16:32:02Z","timestamp":1579192322000},"page":"40-44","source":"Crossref","is-referenced-by-count":21,"title":["Posterior chamber phakic intraocular lens for the correction of presbyopia in highly myopic patients"],"prefix":"10.1097","volume":"46","author":[{"given":"Pavel","family":"Stodulka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Slovak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Sramka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaroslav","family":"Polisensky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karel","family":"Liska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230819","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.1016\/j.ophtha.2018.04.013","article-title":"Global prevalence of presbyopia and vision impairment from uncorrected presbyopia: systematic review, meta-analysis, and modelling","volume":"125","author":"Fricke","year":"2018","journal-title":"Ophthalmology"},{"key":"R2-20230819","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1001\/archopht.126.12.1731","article-title":"Global vision impairment due to uncorrected presbyopia","volume":"126","author":"Holden","year":"2008","journal-title":"Arch Ophthalmol"},{"key":"R3-20230819","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050","volume":"123","author":"Holden","year":"2016","journal-title":"Ophthalmology"},{"key":"R4-20230819","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.oftal.2017.04.005","article-title":"Non-lens-based surgical techniques for presbyopia correction [in Spanish]","volume":"92","author":"Bilbao-Calabuig","year":"2017","journal-title":"Arch la Soc Espa\u00f1ola Oftalmol"},{"key":"R5-20230819","first-page":"339","article-title":"Multifocal intraocular lenses and extended depth of focus intraocular lenses","volume":"6","author":"Breyer","year":"2017","journal-title":"Asia-Pacific J Ophthalmol"},{"key":"R6-20230819","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1097\/ICU.0000000000000490","article-title":"Extended depth of focus intraocular lenses for presbyopia","volume":"29","author":"Akella","year":"2018","journal-title":"Curr Opin Ophthalmol"},{"key":"R7-20230819","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1136\/bjo.2004.052720","article-title":"Refractive lens exchange in high myopia: long term follow up","volume":"89","author":"Horgan","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"R8-20230819","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/s40662-014-0010-2","article-title":"Refractive lens exchange in modern practice: when and when not to do it?","volume":"1","author":"Ali\u00f3","year":"2014","journal-title":"Eye Vis"},{"key":"R9-20230819","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1590\/S0004-27492007000400009","article-title":"Phakic intraocular lens for presbyopia correction [in Portuguese]","volume":"70","author":"Ferraz","year":"2007","journal-title":"Arq Bras Oftalmol"},{"key":"R10-20230819","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.preteyeres.2018.09.004","article-title":"Presbyopia: effectiveness of correction strategies","volume":"68","author":"Wolffsohn","year":"2019","journal-title":"Prog Retin Eye Res"},{"key":"R11-20230819","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1097\/ICU.0b013e32834cd5d1","article-title":"Refractive lens exchange versus phakic intraocular lenses","volume":"23","author":"Nanavaty","year":"2012","journal-title":"Curr Opin Ophthalmol"},{"key":"R12-20230819","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1111\/ceo.12691","article-title":"Long-term clinical results of posterior chamber phakic intraocular lens implantation to correct myopia","volume":"44","author":"Lee","year":"2016","journal-title":"Clin Exp Ophthalmol"},{"key":"R13-20230819","first-page":"87","article-title":"Incidence of cataract following implantation of a posterior-chamber phakic lens ICL (Implantable Collamer Lens)\u2014long-term results","volume":"73","author":"Kocova","year":"2017","journal-title":"Cesk Slov Oftalmol"},{"key":"R14-20230819","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.joco.2016.01.001","article-title":"Implantable Collamer Lens V4b and V4c for correction of high myopia","volume":"27","author":"Bhandari","year":"2016","journal-title":"J Curr Ophthalmol"},{"key":"R15-20230819","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.jcrs.2018.03.005","article-title":"Phakic intraocular lenses: where are we now?","volume":"44","author":"Kohnen","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R16-20230819","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/S0161-6420(00)00403-6","article-title":"Safety of posterior chamber phakic intraocular lenses for the correction of high myopia: anterior segment changes after posterior chamber phakic intraocular lens implantation","volume":"108","author":"Jim\u00e9nez-Alfaro","year":"2001","journal-title":"Ophthalmology"},{"key":"R17-20230819","doi-asserted-by":"crossref","first-page":"1329874","DOI":"10.1155\/2018\/1329874","article-title":"Early results with a new posterior chamber phakic intraocular lens in patients with high myopia","volume":"2018","author":"Yasa","year":"2018","journal-title":"J Ophthalmol"},{"key":"R18-20230819","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/j.jcrs.2003.09.047","article-title":"Corneal endothelial assessment after ICL implantation","volume":"30","author":"Edelhauser","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R19-20230819","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.ophtha.2016.09.034","article-title":"Special report: American Academy of Ophthalmology Task Force recommendations for specular microscopy for phakic intraocular lenses","volume":"124","author":"MacRae","year":"2017","journal-title":"Ophthalmology"},{"key":"R20-20230819","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1136\/bjophthalmol-2016-309363","article-title":"Comparison of corneal endothelial cell density and morphology after posterior chamber phakic intraocular lens implantation with and without a central hole","volume":"101","author":"Goukon","year":"2017","journal-title":"Br J Ophthalmol"},{"key":"R21-20230819","doi-asserted-by":"crossref","first-page":"e3270","DOI":"10.1097\/MD.0000000000003270","article-title":"Long-term comparison of posterior chamber phakic intraocular lens with and without a central hole (hole ICL and conventional ICL) implantation for moderate to high myopia and myopic astigmatism","volume":"95","author":"Shimizu","year":"2016","journal-title":"Medicine (Baltimore)"},{"key":"R22-20230819","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1016\/j.ophtha.2009.12.013","article-title":"Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients","volume":"117","author":"Schmidinger","year":"2010","journal-title":"Ophthalmology"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000033","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T07:52:58Z","timestamp":1692431578000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000033"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000033","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"value":"0886-3350","type":"print"},{"value":"1873-4502","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}