{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T04:26:47Z","timestamp":1784262407060,"version":"3.55.0"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Cataract Refract Surg"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To implant a small-aperture intraocular lens (IOL) (IC-8) in eyes with severe corneal irregularities to reduce higher-order aberrations and provide better central visual acuity.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>University Hospital, LMU Munich, Germany.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective nonrandomized interventional case series.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Eyes with severe corneal irregularities due to keratoconus, previous penetrating keratoplasty, status postradial keratotomy, or scarring after ocular trauma were enrolled. Exclusion criteria were progressive keratoconus, pseudoexfoliation, glaucoma, maculopathy, reduced endothelial cells (&lt;1800 cells\/mm<jats:sup>2<\/jats:sup>), and central corneal opacity. Conventional phacoemulsification with implantation of the small-aperture IOL was performed. The primary efficacy endpoint was corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), and uncorrected near visual acuity (UNVA). Secondary endpoints were life quality assessment using the Visual Function Questionnaire-25 and determination of the refractive defocus curve.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Seventeen eyes of 17 patients were enrolled. In all 17 patients, CDVA improved from 0.37 \u00b1 0.09 to 0.19 \u00b1 0.06 logarithm of the minimum angle of resolution (logMAR) 3 months postoperatively (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .0001). Similarly, postoperative UDVA, UIVA, and UNVA improved significantly in 100%, 88%, and 88%, respectively. The defocus curve showed best results at 0.17 logMAR with a defocus of \u22120.5 diopter. In addition, overall life quality analyses reported less difficulty with activities under reduced optical phenomena conditions.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The small-aperture IOL was a useful option in eyes with severe corneal irregularities, had a high safety index and a high satisfaction rate, and can lead to better visual quality in these cases. Further studies are needed to improve power calculation of this IOL.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/j.jcrs.0000000000000045","type":"journal-article","created":{"date-parts":[[2020,1,24]],"date-time":"2020-01-24T18:47:10Z","timestamp":1579891630000},"page":"188-192","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":49,"title":["Safety and efficacy of a small-aperture capsular bag\u2013fixated intraocular lens in eyes with severe corneal irregularities"],"prefix":"10.1097","volume":"46","author":[{"given":"Mehdi","family":"Shajari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc J.","family":"Mackert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian","family":"Langer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Kreutzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Armin","family":"Wolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Kohnen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siegfried","family":"Priglinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang J.","family":"Mayer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250516","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/S0886-3350(13)80339-2","article-title":"An improved universal theoretical formula for intraocular lens power prediction","volume":"19","author":"Barrett","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R2-20250516","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1167\/iovs.14-15659","article-title":"Anterior surface-based keratometry compared with Scheimpflug tomography-based total corneal astigmatism","volume":"56","author":"Tonn","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R3-20250516","doi-asserted-by":"crossref","first-page":"1176","DOI":"10.1016\/j.ajo.2015.08.017","article-title":"The small-aperture IC-8 intraocular lens: a new concept for added depth of focus in cataract patients","volume":"160","author":"Grabner","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R4-20250516","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1038\/s41433-019-0363-9","article-title":"Small aperture IC-8 intraocular lens in cataract patients: achieving extended depth of focus through small aperture optics","volume":"33","author":"Hooshmand","year":"2019","journal-title":"Eye (Lond)"},{"key":"R5-20250516","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1007\/s004170000188","article-title":"Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis","volume":"238","author":"Haigis","year":"2000","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R6-20250516","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","article-title":"Development of the SRK\/T intraocular lens implant power calculation formula","volume":"16","author":"Retzlaff","year":"1990","journal-title":"J Cataract Refract Surg"},{"key":"R8-20250516","doi-asserted-by":"crossref","first-page":"706","DOI":"10.3928\/1081597X-20160721-01","article-title":"Small-aperture intraocular lens implantation in a patient with an irregular cornea","volume":"32","author":"Schultz","year":"2016","journal-title":"J Refract Surg"},{"key":"R9-20250516","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1016\/j.jcrs.2018.06.047","article-title":"Phacoemulsification with intraocular pinhole implantation associated with Descemet membrane endothelial keratoplasty to treat failed full-thickness graft with dense cataract","volume":"44","author":"Trindade","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250516","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1016\/j.jcrs.2017.09.014","article-title":"New pinhole sulcus implant for the correction of irregular corneal astigmatism","volume":"43","author":"Trindade","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R11-20250516","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1038\/eye.2017.239","article-title":"Assessment of a novel pinhole supplementary implant for sulcus fixation in pseudophakic cadaver eyes","volume":"32","author":"Tsaousis","year":"2018","journal-title":"Eye (Lond)"},{"key":"R12-20250516","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1016\/j.jcrs.2017.04.038","article-title":"Prospective multicenter trial of a small-aperture intraocular lens in cataract surgery","volume":"43","author":"Dick","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250516","doi-asserted-by":"crossref","first-page":"629","DOI":"10.3928\/1081597X-20180716-02","article-title":"Binocular and monocular implantation of small-aperture intraocular lenses in cataract surgery","volume":"34","author":"Dick","year":"2018","journal-title":"J Refract Surg"},{"key":"R14-20250516","doi-asserted-by":"crossref","first-page":"175","DOI":"10.5301\/EJO.2011.8371","article-title":"Visual acuity, contrast sensitivity, subjective quality of vision, and quality of life with 4 different multifocal IOLs","volume":"22","author":"Gil","year":"2012","journal-title":"Eur J Ophthalmol"},{"key":"R15-20250516","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1097\/00055735-200502000-00006","article-title":"Multifocal intraocular lenses","volume":"16","author":"Bellucci","year":"2005","journal-title":"Curr Opin Ophthalmol"},{"key":"R16-20250516","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1136\/bjophthalmol-2017-311651","article-title":"Evaluation of keratoconus progression","volume":"103","author":"Shajari","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"R17-20250516","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1097\/ICO.0000000000001143","article-title":"Characteristics of corneal astigmatism of anterior and posterior surface in a normal control group and patients with keratoconus","volume":"36","author":"Shajari","year":"2017","journal-title":"Cornea"}],"container-title":["Journal of Cataract &amp; Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000045","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,16]],"date-time":"2025-05-16T19:00:25Z","timestamp":1747422025000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000045"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2]]},"references-count":16,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000045","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"value":"0886-3350","type":"print"},{"value":"1873-4502","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2]]},"assertion":[{"value":"2019-04-26","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-09-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}