{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T01:05:56Z","timestamp":1792631156854,"version":"4.5.0"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Cataract Refract Surg"],"published-print":{"date-parts":[[2020,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To observe the distributions and changes in angle kappa and angle alpha preoperatively and postoperatively in patients with cataract who were implanted with a multifocal intraocular lens (mIOL).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Setting:<\/jats:title>\n                    <jats:p>The First Affiliated Hospital of Northwest University, Shaanxi, China.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Prospective nonrandomized noncomparative case series.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Eyes that underwent phacoemulsification were included. The magnitudes and orientations of angle kappa and angle alpha preoperatively and postoperatively were compared, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The study comprised 81 eyes of 70 patients. The magnitude of angle kappa significantly decreased after phacoemulsification. No significant differences were observed between preoperative and postoperative angle kappa in orientation, as well as between preoperative and postoperative angle alpha. The correlations between preoperative and postoperative angle kappa and angle alpha were significant. There were displacement vectors for angle kappa (0.15 \u00b1 0.10) and angle alpha (0.12 \u00b1 0.12) after phacoemulsification. Locations of angle kappa of right and left eyes were scattered mostly in the temporal side of corneal light reflection, whereas locations of angle alpha were well organized in the horizontal position on temporal sides of corneal light reflection.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The distribution of angle alpha was more organized compared with angle kappa. Angle kappa may change after phacoemulsification. During preoperative evaluation for patients with cataract planning for mIOLs implanted angle alpha may be a more reliable and stable factor compared with angle kappa.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/j.jcrs.0000000000000063","type":"journal-article","created":{"date-parts":[[2020,2,6]],"date-time":"2020-02-06T18:15:31Z","timestamp":1581012931000},"page":"365-371","source":"Crossref","is-referenced-by-count":54,"title":["Changes in angle kappa and angle alpha before and after cataract surgery"],"prefix":"10.1097","volume":"46","author":[{"given":"Rui","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tan","family":"Long","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Gu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ting","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230819","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","article-title":"Dissatisfaction after implantation of multifocal intraocular lenses","volume":"37","author":"de Vries","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R2-20230819","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1016\/j.jcrs.2009.01.031","article-title":"Dissatisfaction after multifocal intraocular lens implantation","volume":"35","author":"Woodward","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R3-20230819","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1007\/s004170100348","article-title":"Patient satisfaction after implantation of diffractive designed multifocal intraocular lenses in dependence on objective parameters","volume":"239","author":"Walkow","year":"2001","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R4-20230819","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1038\/eye.2011.150","article-title":"Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation","volume":"25","author":"Prakash","year":"2011","journal-title":"Eye (Lond)"},{"key":"R5-20230819","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1007\/s00347-008-1745-8","article-title":"Use of multifocal intraocular lenses and criteria for patient selection [in German]","volume":"105","author":"Kohnen","year":"2008","journal-title":"Ophthalmology"},{"key":"R6-20230819","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1016\/j.ajo.2008.07.033","article-title":"Maximizing satisfaction with presbyopia-correcting intraocular lenses: the missing links","volume":"146","author":"Pepose","year":"2008","journal-title":"Am J Ophthalmol"},{"key":"R7-20230819","first-page":"64","article-title":"The importance of angle kappa for centration of multifocal intraocular lenses","volume":"69","author":"Karhanov\u00e1","year":"2013","journal-title":"Cesk Slov Oftalmol"},{"key":"R8-20230819","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1016\/j.jcrs.2018.05.026","article-title":"Role of angle \u03ba in visual quality in patients with a trifocal diffractive intraocular lens","volume":"44","author":"Qi","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R9-20230819","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.jcrs.2018.08.025","article-title":"Evaluation of crystalline lens and intraocular lens tilt using a swept-source optical coherence tomography biometer","volume":"45","author":"Wang","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R10-20230819","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1001\/archopht.1993.01090060119035","article-title":"The Lens Opacities Classification System III","volume":"111","author":"Chylack","year":"1993","journal-title":"Arch Ophthalmol"},{"key":"R11-20230819","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1038\/eye.2017.232","article-title":"SIA-formula: an easy way to calculate surgically induced astigmatism","volume":"32","author":"S\u00e1nchez-Tabernero","year":"2018","journal-title":"Eye"},{"key":"R12-20230819","doi-asserted-by":"crossref","first-page":"966","DOI":"10.3928\/1081597X-20100114-06","article-title":"Distribution of angle kappa measurements with Orbscan II in a population-based survey","volume":"26","author":"Hashemi","year":"2010","journal-title":"J Refract Surg"},{"key":"R13-20230819","doi-asserted-by":"crossref","first-page":"616","DOI":"10.3928\/1081597X-20140815-02","article-title":"Repeatability, reproducibility, and agreement between three different Scheimpflug systems in measuring corneal and anterior segment biometry","volume":"30","author":"Hern\u00e1ndez-Camarena","year":"2014","journal-title":"J Refract Surg"},{"key":"R14-20230819","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.1016\/j.jcrs.2011.07.016","article-title":"Role of angle kappa in patient dissatisfaction with refractive-design multifocal intraocular lenses","volume":"37","author":"Prakash","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R15-20230819","doi-asserted-by":"crossref","first-page":"151","DOI":"10.4103\/0974-620X.122268","article-title":"Angle kappa and its importance in refractive surgery","volume":"6","author":"Moshirfar","year":"2013","journal-title":"Oman J Ophthalmol"},{"key":"R16-20230819","first-page":"2508","article-title":"Pupil location under mesopic, photopic, and pharmacologically dilated conditions","volume":"43","author":"Yang","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000063","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T04:20:39Z","timestamp":1692418839000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000063"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000063","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"value":"0886-3350","type":"print"},{"value":"1873-4502","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3]]}}}