{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T23:17:06Z","timestamp":1773184626430,"version":"3.50.1"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Cataract Refract Surg"],"published-print":{"date-parts":[[2020,3]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To compare the safety, efficacy, and predictability of femtosecond laser\u2013enabled anterior penetrating and intrastromal arcuate incisions for the correction of preoperative astigmatism at the time of cataract surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Nethradhama Super Speciality Eye Hospital, Bangalore, India.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective randomized comparison study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This study included 50 eyes of 50 patients who had femtosecond laser\u2013assisted cataract surgery with the CATALYS Precision System (Johnson &amp; Johnson Vision Care, Inc.). Twenty-five eyes received anterior penetrating and 25 eyes received intrastromal arcuate incisions for the correction of corneal astigmatism in the range of 0.75 to 2.00 diopters (D). Six months postoperatively, vector analysis of astigmatism was performed using the Alpins method with the ASSORT software.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The mean preoperative keratometric astigmatism and target-induced astigmatism were 1.07 D and 1.16 D in the anterior penetrating group and 1.23 D and 1.50 D in the intrastromal group, respectively. There was no statistically significant difference between the postoperative keratometric astigmatism (anterior penetrating = 0.65, intrastromal = 0.90, <jats:italic toggle=\"yes\">P<\/jats:italic> value = .13) and surgically induced astigmatism (anterior penetrating = 1.23, intrastromal = 1.08, <jats:italic toggle=\"yes\">P<\/jats:italic> value = .55) at 6 months postoperatively. The correction index was 0.95 in the anterior penetrating group and 0.55 in the intrastromal group, signifying an undercorrection of 5% and 45% of eyes in the anterior penetrating and intrastromal group, respectively. Eighty percent of eyes in the anterior penetrating group and 72% of eyes in the intrastromal group were within \u00b10.5 D of refractive astigmatism.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Both anterior penetrating and intrastromal incisions were effective in reducing preoperative astigmatism using the femtosecond laser technology. However, the anterior penetrating incisions showed comparatively better correction, whereas the intrastromal incisions resulted in significant undercorrection at 6 months.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/j.jcrs.0000000000000069","type":"journal-article","created":{"date-parts":[[2020,2,6]],"date-time":"2020-02-06T23:15:31Z","timestamp":1581030931000},"page":"394-402","source":"Crossref","is-referenced-by-count":18,"title":["Comparison of astigmatism correction between anterior penetrating and intrastromal arcuate incisions in eyes undergoing femtosecond laser\u2013assisted cataract surgery"],"prefix":"10.1097","volume":"46","author":[{"given":"Sri","family":"Ganesh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sheetal","family":"Brar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raghavender","family":"Reddy Arra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230819","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/ICU.0b013e328319c27a","article-title":"Correction of astigmatism at the time of cataract surgery","volume":"20","author":"Amesbury","year":"2009","journal-title":"Curr Opin Ophthalmol"},{"key":"R2-20230819","doi-asserted-by":"crossref","first-page":"2261","DOI":"10.1016\/j.jcrs.2005.08.046","article-title":"Limbal relaxing incisions versus on-axis incisions to reduce corneal astigmatism at the time of cataract surgery","volume":"31","author":"Kaufmann","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R3-20230819","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1001\/archopht.1995.01100030031017","article-title":"Astigmatism reduction clinical trial: a multicentre prospective evaluation of the predictability of arcuate keratotomy; evaluation of surgical nomogram predictability","volume":"113","author":"Price","year":"1995","journal-title":"Arch Ophthalmol"},{"key":"R4-20230819","doi-asserted-by":"crossref","first-page":"1916","DOI":"10.1016\/j.jcrs.2013.08.019","article-title":"Bilateral femtosecond laser\u2013enabled intrastromal astigmatic keratotomy to correct high post-penetrating keratoplasty astigmatism","volume":"39","author":"Viswanathan","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R5-20230819","doi-asserted-by":"crossref","first-page":"180","DOI":"10.3928\/1081597X-20130129-09","article-title":"Nonpenetrating femtosecond laser intrastromal astigmatic keratotomy in patients with mixed astigmatism after previous refractive surgery","volume":"29","author":"Venter","year":"2013","journal-title":"J Refract Surg"},{"key":"R6-20230819","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.jcrs.2015.07.045","article-title":"Nonpenetrating femtolaser intrastromal astigmatic keratotomy in eyes having cataract surgery","volume":"42","author":"Day","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R7-20230819","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","article-title":"Development of the SRK\/T intraocular lens implant power calculation formula","volume":"16","author":"Retzlaff","year":"1990","journal-title":"J Cataract Refract Surg"},{"key":"R8-20230819","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","article-title":"A three-part system for refining intraocular lens power calculations","volume":"14","author":"Holladay","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R9-20230819","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1007\/s004170000188","article-title":"Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis","volume":"238","author":"Haigis","year":"2000","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R10-20230819","doi-asserted-by":"crossref","first-page":"511","DOI":"10.3928\/1081597X-20140711-02","article-title":"Anterior gas breakthrough during femtosecond intrastromal astigmatic keratotomy (FISK) [letter]","volume":"30","author":"Kankariya","year":"2014","journal-title":"J Refract Surg"},{"key":"R11-20230819","doi-asserted-by":"crossref","first-page":"1224","DOI":"10.1016\/j.jcrs.2014.04.021","article-title":"Corneal perforation by an astigmatic keratotomy performed with an optical coherence tomography guided femtosecond laser","volume":"40","author":"Cherfan","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R12-20230819","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1016\/S0886-3350(13)80617-7","article-title":"A new method of analyzing vectors for changes in astigmatism","volume":"19","author":"Alpins","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R13-20230819","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0886-3350(00)00798-7","article-title":"Astigmatism analysis by the Alpins method","volume":"27","author":"Alpins","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R14-20230819","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.ajo.2015.05.004","article-title":"Vector analysis of corneal astigmatism after combined femtosecond-assisted phacoemulsification and arcuate keratotomy","volume":"160","author":"Chan","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R15-20230819","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jcrs.2015.09.028","article-title":"Predictors of femtosecond laser intrastromal astigmatic keratotomy efficacy for astigmatism management in cataract surgery","volume":"42","author":"Day","year":"2016","journal-title":"J Cataract Refractive Surg"},{"key":"R16-20230819","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.ajo.2016.07.022","article-title":"Corneal astigmatism and aberrations after combined femtosecond-assisted phacoemulsification and arcuate keratotomy: two-year results","volume":"170","author":"Chan","year":"2016","journal-title":"Am J Ophthalmol"},{"key":"R17-20230819","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.joco.2016.05.004","article-title":"Age-related variations in corneal biomechanical properties","volume":"28","author":"Sharifipour","year":"2016","journal-title":"J Curr Ophthalmol"},{"key":"R18-20230819","doi-asserted-by":"crossref","first-page":"1676","DOI":"10.1016\/j.jcrs.2014.01.045","article-title":"Long-term stability of keratometric astigmatism after limbal relaxing incisions","volume":"40","author":"Lim","year":"2014","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000069","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T08:33:35Z","timestamp":1692434015000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000069"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000069","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"value":"0886-3350","type":"print"},{"value":"1873-4502","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3]]}}}