{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T23:13:05Z","timestamp":1793142785936,"version":"4.5.0"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Cataract Refract Surg"],"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:p>The purpose was to review and document the methods used to calculate the power of the intraocular lens (IOL) to be implanted in cataract surgery in the specific scenario of eyes with keratoconus. This review included all scientific articles published in English that focused on the parameters and formulas used to calculate the power of the IOL to be implanted in eyes with keratoconus undergoing cataract surgery. There are few publications that show in detail how IOL power is calculated in these particular cases. If the keratometric value used was based on the standard refractive index (1.3375), it resulted in a postoperative refractive error with a tendency to hyperopia. The SRK\/T formula yielded the best outcomes. The greater the severity of keratoconus the greater was the deviation of the postoperative refractive status from the target outcome.<\/jats:p>","DOI":"10.1097\/j.jcrs.0000000000000082","type":"journal-article","created":{"date-parts":[[2020,5,2]],"date-time":"2020-05-02T03:36:28Z","timestamp":1588390588000},"page":"778-783","source":"Crossref","is-referenced-by-count":22,"title":["Intraocular lens power calculation in eyes with keratoconus"],"prefix":"10.1097","volume":"46","author":[{"given":"Nuria","family":"Garz\u00f3n","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Arriola-Villalobos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gema","family":"Felipe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Poyales","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mar\u00eda","family":"Garc\u00eda-Montero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230819","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","article-title":"Keratoconus","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Surv Ophthalmol"},{"key":"R2-20230819","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.clae.2010.04.006","article-title":"Keratoconus: a review","volume":"33","author":"Romero-Jimenez","year":"2010","journal-title":"Contact Lens Anterior Eye"},{"key":"R3-20230819","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/s40123-017-0099-1","article-title":"Keratoconus treatment algorithm","volume":"6","author":"Andreanos","year":"2017","journal-title":"Ophthalmol Ther"},{"key":"R4-20230819","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.jcrs.2006.11.023","article-title":"Validity of the keratometric index: large population-based study","volume":"33","author":"Fam","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R5-20230819","doi-asserted-by":"crossref","first-page":"13.1","DOI":"10.1167\/8.2.13","article-title":"How keratoconus influences optical performance of the eye","volume":"8","author":"Tan","year":"2008","journal-title":"J Vis."},{"key":"R6-20230819","doi-asserted-by":"crossref","first-page":"376","DOI":"10.3109\/08820538.2014.959193","article-title":"Cataract and keratoconus: minimizing complications in intraocular lens calculations","volume":"29","author":"Bozorg","year":"2014","journal-title":"Semin Ophthalmol"},{"key":"R7-20230819","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1038\/s41598-018-20040-w","article-title":"Predictability of intraocular lens power calculation for cataract with keratoconus: a multicenter study","volume":"8","author":"Kamiya","year":"2018","journal-title":"Scientific Rep"},{"key":"R8-20230819","doi-asserted-by":"crossref","first-page":"357","DOI":"10.3928\/1081597X-20090401-07","article-title":"Circular keratotomy to reduce astigmatism and improve vision in stage I and II keratoconus","volume":"25","author":"Krumeich","year":"2009","journal-title":"J Refract Surg"},{"key":"R9-20230819","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1136\/bjophthalmol-2013-303829","article-title":"Cataract surgery outcome in eyes with keratoconus","volume":"98","author":"Watson","year":"2014","journal-title":"Br J Ophthalmol"},{"key":"R10-20230819","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/S0886-3350(98)80284-8","article-title":"Live-epikeratophakia for keratoconus","volume":"24","author":"Krumeich","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R11-20230819","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","article-title":"Development of the SRK\/T intraocular lens implant power calculation formula","volume":"16","author":"Retzlaff","year":"1990","journal-title":"J Cataract Refract Surg"},{"key":"R12-20230819","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/j.jcrs.2018.11.029","article-title":"Intraocular lens power calculation in eyes with keratoconus","volume":"45","author":"Savini","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R14-20230819","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1007\/s004170000188","article-title":"Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis","volume":"238","author":"Haigis","year":"2000","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R15-20230819","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","article-title":"The Hoffer Q formula: a comparison of theoretic and regression formulas","volume":"19","author":"Hoffer","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R16-20230819","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","article-title":"A three-part system for refining intraocular lens power calculations","volume":"14","author":"Holladay","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R17-20230819","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1016\/j.jcrs.2006.01.063","article-title":"Refractive lens exchange in keratoconus","volume":"32","author":"Leccisotti","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R19-20230819","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1097\/ICL.0000000000000136","article-title":"Evaluation of the results of using toric IOL in the cataract surgery of keratoconus patients","volume":"41","author":"Hashemi","year":"2015","journal-title":"Eye Contact Lens"},{"key":"R20-20230819","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/S0886-3350(88)80087-7","article-title":"Comparison of the SRK II\u2122 formula and other second generation formulas","volume":"14","author":"Sanders","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R21-20230819","doi-asserted-by":"crossref","first-page":"658","DOI":"10.3928\/1081597X-20110531-01","article-title":"Refractive lens exchange with toric intraocular lenses in keratoconus","volume":"27","author":"Jaimes","year":"2011","journal-title":"J Refractive Surg"},{"key":"R22-20230819","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1136\/bjophthalmol-2013-303765","article-title":"MICS with toric intraocular lenses in keratoconus: outcomes and predictability analysis of postoperative refraction","volume":"98","author":"Alio","year":"2014","journal-title":"Br J Ophthalmol"},{"key":"R23-20230819","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1097\/ICL.0b013e318030c96d","article-title":"Cataract surgery in keratoconus","volume":"33","author":"Thebpatiphat","year":"2007","journal-title":"Eye Contact Lens"},{"key":"R24-20230819","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/S0146-2776(81)80031-6","article-title":"Comparison of the accuracy of the Binkhorst, Colenbrander, and SRKtm implant power prediction formulas","volume":"7","author":"Sanders","year":"1981","journal-title":"Am Intra-Ocular Implant Soc J"},{"key":"R25-20230819","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1016\/j.jcrs.2015.11.001","article-title":"Intraocular lens power calculation in cases with posterior keratoconus","volume":"41","author":"Tamaoki","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R26-20230819","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1097\/ICO.0b013e31820009d4","article-title":"Cataract surgery with toric intraocular lens implantation in keratoconus: a case report","volume":"30","author":"Visser","year":"2011","journal-title":"Cornea"},{"key":"R27-20230819","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/S0886-3350(96)80049-6","article-title":"Calculating intraocular lens power in eyes with keratoconus using videokeratography","volume":"22","author":"Celikkol","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"R28-20230819","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1097\/ICO.0b013e3182797900","article-title":"Intraocular lens power calculations in a patient with posterior keratoconus","volume":"32","author":"Park","year":"2013","journal-title":"Cornea"},{"key":"R29-20230819","doi-asserted-by":"crossref","first-page":"690","DOI":"10.4103\/ijo.IJO_274_16","article-title":"Preliminary validation of an optimized algorithm for intraocular lens power calculation in keratoconus","volume":"65","author":"Camps","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"R30-20230819","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1097\/ICO.0000000000000048","article-title":"Estimation of the central corneal power in keratoconus: theoretical and clinical assessment of the error of the keratometric approach","volume":"33","author":"Pinero","year":"2014","journal-title":"Cornea"},{"key":"R31-20230819","doi-asserted-by":"crossref","first-page":"194","DOI":"10.2174\/1874364101711010194","article-title":"Cataract surgery in patients with keratoconus: pearls and pitfalls","volume":"11","author":"Aiello","year":"2017","journal-title":"Open Ophthalmol J"},{"key":"R32-20230819","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/ICU.0000000000000440","article-title":"Cataract surgery in eyes with keratoconus: a review of the current literature","volume":"29","author":"Moshirfar","year":"2018","journal-title":"Curr Opin Ophthalmol"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000082","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T08:22:21Z","timestamp":1692433341000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000082"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000082","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"value":"0886-3350","type":"print"},{"value":"1873-4502","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5]]}}}