{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T00:01:46Z","timestamp":1768435306564,"version":"3.49.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Cataract Refract Surg"],"published-print":{"date-parts":[[2020,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To investigate whether postoperative-induced refractive astigmatism after small-incision lenticule extraction (SMILE) could be predicted by preoperative objective astigmatism measured with autorefraction, keratometry, and Scheimpflug tomography.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>University eye clinic.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective case series.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Only eyes without preoperative subjective astigmatism treated with SMILE for myopia were included. Postoperative subjective astigmatism was compared with preoperative objective astigmatism. Examinations were performed before SMILE and 3 months postoperatively and included subjective refraction, keratometry, autorefraction, and Scheimpflug tomographer measurements. Astigmatism was analyzed using double-angle plots and multivariate statistics.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of 358 eyes of 358 patients were included. The mean preoperative sphere was \u22127.33 diopter (D) \u00b1 1.46 (SD). The postoperative spherical equivalent was \u22120.30 \u00b1 0.49 D. Postoperatively, 79.6% and 98.9% of patients had a subjective cylinder \u22640.50 D and \u22641.00 D, respectively. Preoperative objective astigmatism measured with keratometry, autorefraction, and Scheimpflug tomography was significantly different (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .05) from postoperative subjective refraction when all patients were analyzed; for patients with postoperative refractive astigmatism \u22650.50 D, preoperative astigmatism with keratometry and Scheimpflug tomography was not significantly different from postoperative refractive astigmatism. Preoperative objective astigmatism \u22650.50 D increased the risk ratio of postoperative subjective astigmatism \u22650.50 D by 2.2 (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Preoperative objective astigmatism could not be directly interchanged with postoperative subjective astigmatism, but the presence of preoperative astigmatism \u22650.50 D doubled the risk of inducing a postoperative subjective astigmatism \u22650.50 D. Extra care when performing subjective refraction should be taken in the presence of high objective astigmatism.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/j.jcrs.0000000000000083","type":"journal-article","created":{"date-parts":[[2020,2,6]],"date-time":"2020-02-06T23:15:31Z","timestamp":1581030931000},"page":"524-533","source":"Crossref","is-referenced-by-count":10,"title":["Astigmatism prediction in small-incision lenticule extraction"],"prefix":"10.1097","volume":"46","author":[{"given":"Anders","family":"Gyldenkerne","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jesper","family":"Hjortdal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anders","family":"Ivarsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230819","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/j.ophtha.2013.11.006","article-title":"Safety and complications of more than 1500 small-incision lenticule extraction procedures","volume":"121","author":"Ivarsen","year":"2014","journal-title":"Ophthalmology"},{"key":"R2-20230819","doi-asserted-by":"crossref","first-page":"240","DOI":"10.3928\/1081597X-20140320-02","article-title":"Correction of myopic astigmatism with small incision lenticule extraction","volume":"30","author":"Ivarsen","year":"2014","journal-title":"J Refract Surg"},{"key":"R3-20230819","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40662-017-0091-9","article-title":"Small incision lenticule extraction (SMILE) in the correction of myopic astigmatism: outcomes and limitations\u2014an update","volume":"4","author":"Ali\u00f3 del Barrio","year":"2017","journal-title":"Eye Vis"},{"key":"R4-20230819","doi-asserted-by":"crossref","first-page":"11","DOI":"10.3928\/1081597X-20161006-04","article-title":"Changes in astigmatism, densitometry, and aberrations after SMILE for low to high myopic astigmatism: a 12-month prospective study","volume":"33","author":"Pedersen","year":"2017","journal-title":"J Refract Surg"},{"key":"R5-20230819","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.jcrs.2018.08.030","article-title":"Small-incision lenticule extraction for the correction of myopic astigmatism","volume":"45","author":"Taneri","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R6-20230819","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.1016\/j.jcrs.2018.06.029","article-title":"Correction of astigmatism with small-incision lenticule extraction: impact of against-the-rule and with-the-rule astigmatism","volume":"44","author":"Ivarsen","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R7-20230819","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1016\/j.jcrs.2018.07.027","article-title":"Pursuing perfection in intraocular lens calculations: IV. Rethinking astigmatism analysis for intraocular lens-based surgery: suggested terminology, analysis, and standards for outcome reports","volume":"44","author":"Abulafia","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R8-20230819","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1111\/j.1755-3768.2008.01287.x","article-title":"Assessment and statistics of surgically induced astigmatism","volume":"86","author":"Naeser","year":"2008","journal-title":"Acta Ophthalmol"},{"key":"R9-20230819","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.jcrs.2018.10.046","article-title":"Astigmatism terminology for corneal and intraocular lens\u2013based surgery","volume":"45","author":"Naeser","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R10-20230819","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/00006324-199706000-00019","article-title":"Power vectors: an application of Fourier analysis to the description and statistical analysis of refractive error","volume":"74","author":"Thibos","year":"1997","journal-title":"Optom Vis Sci"},{"key":"R11-20230819","doi-asserted-by":"crossref","first-page":"2316","DOI":"10.1167\/iovs.17-23451","article-title":"Relationship between decentration and induced corneal higher-order aberrations following small-incision lenticule extraction procedure","volume":"59","author":"Lee","year":"2018","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"R12-20230819","first-page":"171","article-title":"Fourier analysis of video-keratographic data. A tool for separation of spherical, regular astigmatic and irregular astigmatic corneal power components","volume":"15","author":"Hjortdal","year":"1995","journal-title":"Ophthalmic Physiol Opt"},{"key":"R13-20230819","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1097\/00006324-199808000-00028","article-title":"The repeatability of automated and clinician refraction","volume":"75","author":"Bullimore","year":"1998","journal-title":"Optom Vis Sci"},{"key":"R14-20230819","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/00006324-199504000-00008","article-title":"Spherocylindrical refractive errors and visual acuity","volume":"72","author":"Raasch","year":"1995","journal-title":"Optom Vis Sci"},{"key":"R15-20230819","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0886-3350(00)00816-6","article-title":"Multivariate analysis of refractive data: mathematics and statistics of spherocylinders","volume":"27","author":"Naeser","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R16-20230819","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1111\/opo.12202","article-title":"Assessing the corneal power change after refractive surgery using Scheimpflug imaging","volume":"35","author":"Gyldenkerne","year":"2015","journal-title":"Ophthalmic Physiol Opt"},{"key":"R17-20230819","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1177\/096228029900800204","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"Bland","year":"1999","journal-title":"Stat Methods Med Res"},{"key":"R18-20230819","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.jcrs.2013.09.010","article-title":"Minimum amount of astigmatism that should be corrected","volume":"40","author":"Villegas","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R19-20230819","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1097\/OPX.0b013e31804f81a9","article-title":"The precision of wavefront refraction compared to subjective refraction and autorefraction","volume":"84","author":"Pesudovs","year":"2007","journal-title":"Optom Vis Sci"},{"key":"R20-20230819","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.jcrs.2018.08.022","article-title":"Assessment of subjective refraction with a clinical adaptive optics visual simulator","volume":"45","author":"Hervella","year":"201","journal-title":"J Cataract Refract Surg"},{"key":"R21-20230819","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.2147\/OPTH.S37489","article-title":"Astigmatism induced by conventional spherical ablation after PRK and LASIK in myopia with astigmatism < 1.00 D","volume":"6","author":"Christiansen","year":"2012","journal-title":"Clin Ophthalmol"},{"key":"R22-20230819","article-title":"Reproducibility of subjective refraction before and after small incision lenticule extraction (SMILE) for myopia","author":"Nielsen","year":"2019","journal-title":"Acta Ophthalmol"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000083","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T08:28:43Z","timestamp":1692433723000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000083"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4]]},"references-count":22,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000083","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"value":"0886-3350","type":"print"},{"value":"1873-4502","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4]]}}}