{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T09:31:25Z","timestamp":1758706285981},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Cataract Refract Surg"],"published-print":{"date-parts":[[2020,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate the level of agreement of partial coherence interferometry (IOLMaster) and an image-guided system (Verion) in terms of keratometric values and intraocular lens (IOL) power calculation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Department of Ophthalmology, University Hospital of Alexandroupolis, Greece.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Prospective comparative study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Keratometric (K) values and IOL power calculations were compared for 3 toric IOL models (SN6ATx, TFNTx0, and SV25Tx) using 4 formulas (SRK\/T, Holladay 1, Hoffer Q, and Haigis) in patients who had cataract surgery in a consecutive-if-eligible way.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Ninety-eight eyes from 54 patients were included in the study (mean age: 60.2 \u00b1 9.2 years). Compared with the IOLMaster, the Verion measured significantly steeper K1, K2, and Km values (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .05), but no significant difference was observed in astigmatism power and vectors J0 and J45 (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; .05). With the SRK\/T formula, the SN6ATx IOL showed significant difference in the mean IOL power calculated by the 2 devices, whereas no significant difference was observed in the TFNTx0 IOL and the SV25Tx IOL. However, with the Holladay 1, Hoffer Q, and Haigis formulas, a significant difference was found in the mean IOL power of all 3 toric IOL models. Generally, the Verion calculated a significantly lower mean IOL power for almost all formulas and IOL models. For 35 toric implantations, the mean residual astigmatism power, 6 months postoperatively, was 0.29 \u00b1 0.24 diopter.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The IOLMaster and the Verion seemed to present differences in IOL calculation and surgical planning that could lead to unexpected residual refractive error. When discrepancy is detected in IOL calculation, using the IOLMaster as the primary biometry and the Verion as a digital marker alone could provide excellent outcomes in terms of astigmatism correction.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/j.jcrs.0000000000000085","type":"journal-article","created":{"date-parts":[[2020,2,6]],"date-time":"2020-02-06T23:15:31Z","timestamp":1581030931000},"page":"573-580","source":"Crossref","is-referenced-by-count":5,"title":["Level of agreement of intraocular lens power measurements between an image-guided system and partial coherence interferometry"],"prefix":"10.1097","volume":"46","author":[{"given":"Georgios","family":"Labiris","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eirini-Kanella","family":"Panagiotopoulou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Panagiota","family":"Ntonti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Gkika","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aristeidis","family":"Konstantinidis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Irfan","family":"Perente","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Doukas","family":"Dardabounis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Konstantinos","family":"Ioannakis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230819","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1016\/S0039-6257(98)00052-6","article-title":"Risk management lessons from a review of 168 cataract surgery claims","volume":"43","author":"Brick","year":"1999","journal-title":"Surv Ophthalmol"},{"key":"R2-20230819","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1136\/bjo.87.8.960","article-title":"IOL master biometry: refractive results of 100 consecutive cases","volume":"87","author":"Eleftheriadis","year":"2003","journal-title":"Br J Ophthalmol"},{"key":"R3-20230819","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/S0146-2776(81)80031-6","article-title":"Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK implant power prediction formulas","volume":"7","author":"Sanders","year":"1981","journal-title":"Am Intraocul Implant Soc"},{"key":"R4-20230819","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/S0886-3350(88)80087-7","article-title":"Comparison of the SRK II formula and other second generation formulas","volume":"14","author":"Sanders","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R5-20230819","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/S0886-3350(13)80706-7","article-title":"Comparison of the SRK\/T formula and other theoretical and regression formulas","volume":"16","author":"Sanders","year":"1990","journal-title":"J Cataract Refract Surg"},{"key":"R6-20230819","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.sjopt.2010.03.006","article-title":"Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery","volume":"24","author":"El-Nafees","year":"2010","journal-title":"Saudi J Ophthalmol"},{"key":"R7-20230819","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","article-title":"A three-part system for refining intraocular lens power calculations","volume":"14","author":"Holladay","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R9-20230819","doi-asserted-by":"crossref","first-page":"2039","DOI":"10.1016\/j.jcrs.2003.10.009","article-title":"Calculating IOL power in eyes that have had refractive surgery","volume":"29","author":"Koch","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R10-20230819","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.ophtha.2010.07.008","article-title":"Accuracy of intraocular lens calculations using the IOLMaster in eyes with long axial length and a comparison of various formulas","volume":"118","author":"Bang","year":"2011","journal-title":"Ophthalmology"},{"key":"R11-20230819","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1016\/j.ajo.2007.02.043","article-title":"Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia","volume":"143","author":"MacLaren","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"R12-20230819","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","article-title":"The Hoffer Q formula: a comparison of theoretic and regression formulas","volume":"19","author":"Hoffer","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R13-20230819","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1016\/S0886-3350(00)00376-X","article-title":"Clinical results using the Holladay 2 intraocular lens power formula","volume":"26","author":"Hoffer","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R14-20230819","first-page":"78","article-title":"The comparative study of refractive index variations between Haigis, Srk\/T and Hoffer-Q formulas used for preoperative biometry calculation in patients with the axial length >25 mm","volume":"6","author":"Razmjoo","year":"2017","journal-title":"Adv Biomed Res"},{"key":"R15-20230819","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1001\/archopht.1993.01090060119035","article-title":"The Lens Opacities Classification System III","volume":"111","author":"Chylack","year":"1993","journal-title":"Arch Ophthalmol"},{"key":"R16-20230819","doi-asserted-by":"crossref","first-page":"333","DOI":"10.3928\/1081597X-20150424-01","article-title":"Repeatability data and agreement of keratometry with the VERION system compared to the IOLMaster","volume":"31","author":"Nemeth","year":"2015","journal-title":"J Refract Surg"},{"key":"R17-20230819","first-page":"135","article-title":"Image-guided lens extraction surgery: a systematic review","volume":"12","author":"Panagiotopoulou","year":"2019","journal-title":"Int J Ophthalmol"},{"key":"R18-20230819","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/j.jcrs.2016.01.042","article-title":"Comparison of a new image-guided system versus partial coherence interferometry, Scheimpflug imaging, and optical low-coherence reflectometry devices: keratometry and repeatability","volume":"42","author":"Mueller","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R19-20230819","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/S0886-3350(00)00797-5","article-title":"Power vector analysis of the optical outcome of refractive surgery","volume":"27","author":"Thibos","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R20-20230819","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/00006324-199706000-00019","article-title":"Power vectors: an application of Fourier analysis to the description and statistical analysis of refractive error","volume":"74","author":"Thibos","year":"1997","journal-title":"Optom Vis Sci"},{"key":"R21-20230819","doi-asserted-by":"crossref","first-page":"115","DOI":"10.14712\/18059694.2018.129","article-title":"Patients' expectations in lens extraction surgery: a systematic review","volume":"61","author":"Panagiotopoulou","year":"2018","journal-title":"Acta Med (Hradec Kralove)"},{"key":"R22-20230819","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1055\/s-2006-927221","article-title":"Refraktive Gesichtspunkte moderner Katarakt-Chirurgie [Refractive aspects of modern cataract surgery]","volume":"223","author":"Riederle","year":"2006","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"R23-20230819","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","article-title":"Dissatisfaction after implantation of multifocal intraocular lenses","volume":"37","author":"de Vries","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R24-20230819","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/s40662-016-0067-1","article-title":"Evaluation of activities of daily living following pseudophakic presbyopic correction","volume":"4","author":"Labiris","year":"2017","journal-title":"Eye Vis (Lond)"},{"key":"R25-20230819","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.jcrs.2014.06.015","article-title":"Mini-monovision versus multifocal intraocular lens implantation","volume":"41","author":"Labiris","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R26-20230819","first-page":"992","article-title":"A systematic review of pseudophakic monovision for presbyopia correction","volume":"10","author":"Labiris","year":"2017","journal-title":"Int J Ophthalmol"},{"key":"R27-20230819","doi-asserted-by":"crossref","first-page":"2034","DOI":"10.1016\/j.jcrs.2011.05.041","article-title":"Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation","volume":"37","author":"Visser","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R28-20230819","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1159\/000333820","article-title":"Effect of decentration on the optical performance in multifocal intraocular lenses","volume":"227","author":"Soda","year":"2012","journal-title":"Ophthalmologica"},{"key":"R29-20230819","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1007\/s10792-016-0274-8","article-title":"Comparison of keratometric measurements obtained by the Verion Image Guided System with optical biometry and auto-keratorefractometer","volume":"37","author":"Asena","year":"2017","journal-title":"Int Ophthalmol"},{"key":"R30-20230819","doi-asserted-by":"crossref","first-page":"1588","DOI":"10.1016\/j.jcrs.2016.08.028","article-title":"Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system","volume":"42","author":"Thomas","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R31-20230819","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/ceo.12687","article-title":"Assessment of corneal curvature using verion optical imaging system: a comparative study","volume":"44","author":"Lauschke","year":"2016","journal-title":"Clin Exp Ophthalmol"},{"key":"R32-20230819","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1016\/j.jcrs.2016.01.048","article-title":"Comparability of an image-guided system with other instruments in measuring corneal keratometry and astigmatism","volume":"42","author":"Schultz","year":"2016","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000085","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T08:30:09Z","timestamp":1692433809000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000085"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000085","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"value":"0886-3350","type":"print"},{"value":"1873-4502","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4]]}}}