{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T11:54:10Z","timestamp":1795175650659,"version":"4.10.3"},"reference-count":60,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2024,7,8]],"date-time":"2024-07-08T00:00:00Z","timestamp":1720396800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/ http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Osteoporotic vertebral compression fractures (OVCF) may necessitate percutaneous vertebral augmentation (PVA), a procedure not without its risks. One notable complication is cement leakage (CL), which can cause significant distress in patients. Despite its clinical importance, there remains a paucity of meta-analyses investigating these complications and their management in the existing literature.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and methods:<\/jats:title>\n                    <jats:p>The authors systematically reviewed PubMed, Cochrane Library, Embase, and Web of Science databases up to February 2024 to identify studies examining CL following PVA treatment in OVCF. The authors assessed the quality of eligible cohort studies using the Newcastle\u2013Ottawa Scale (NOS), extracted data on incidence, identified risk factors for CL, and conducting meta-analysis with Revman 5.2 software. The authors calculated odd ratios (OR) and mean differences (MD) with 95% CI applying random-effects models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The authors identified twelve cohort studies that matched our strict inclusion criteria. These studies included a total of 2388 patients and 3392 vertebrae. CL was identified in 1132 vertebrae. Notable risk factors for CL included compromised cortical bone integrity (OR 5.00, 95% CI 3.01\u20138.29,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.00001), presence of intravertebral vacuum clefts (OR 1.68, 95% CI 1.07\u20132.65,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.03), basivertebral foramen sign (OR 1.77, 95% CI 1.09\u20132.89,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.02), and volume of cement used (MD 0.75, 95% CI 0.41\u20131.10,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.0001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The authors\u2019 findings underscore the significance of cortical bone integrity, intravertebral vacuum cleft, basivertebral foramen sign, and cement volume as principal determinants of CL risk in PVA for OVCF. These insights advocate for tailored surgical strategies to mitigate the risk of CL in this patient population.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000001895","type":"journal-article","created":{"date-parts":[[2024,7,9]],"date-time":"2024-07-09T01:00:10Z","timestamp":1720486810000},"page":"1231-1243","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":25,"title":["Risk factors for cement leakage after percutaneous vertebral augmentation for osteoporotic vertebral compression fractures: a meta-analysis"],"prefix":"10.1097","volume":"111","author":[{"given":"Yu","family":"Wu","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Dongguan Hospital of Traditional Chinese Medicine, Dongguan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zelin","family":"Zhou","sequence":"additional","affiliation":[{"name":"The First Clinical Medical School of Guangzhou University of Chinese Medicine, Guangzhou"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guoliang","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Dongguan Hospital of Traditional Chinese Medicine, Dongguan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linqiang","family":"Ye","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Dongguan Hospital of Traditional Chinese Medicine, Dongguan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aotian","family":"Lao","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Dongguan Hospital of Traditional Chinese Medicine, Dongguan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuai","family":"Ouyang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Dongguan Hospital of Traditional Chinese Medicine, Dongguan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zefeng","family":"Song","sequence":"additional","affiliation":[{"name":"Medical Department, Dalian University of Technology, Dalian, P.R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhigang","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Dongguan Hospital of Traditional Chinese Medicine, Dongguan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,1]]},"reference":[{"key":"R1-20260304","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1007\/s00198-012-1965-2","article-title":"Life expectancy following diagnosis of a vertebral compression fracture","volume":"24","author":"Edidin","year":"2013","journal-title":"Osteoporos Int"},{"key":"R2-20260304","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1007\/s00198-003-1412-5","article-title":"Incident vertebral fractures and mortality in older women: a prospective study","volume":"14","author":"Kado","year":"2003","journal-title":"Osteoporos Int"},{"key":"R3-20260304","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1007\/s00586-007-0308-z","article-title":"Balloon kyphoplasty in the management of vertebral compression fractures: an updated systematic review and meta-analysis","volume":"16","author":"Taylor","year":"2007","journal-title":"Eur Spine J"},{"key":"R4-20260304","doi-asserted-by":"crossref","first-page":"E13","DOI":"10.36076\/ppj.2017.1.E13","article-title":"Does percutaneous vertebroplasty or balloon kyphoplasty for osteoporotic vertebral compression fractures increase the incidence of new vertebral fractures? A meta-analysis","volume":"20","author":"Zhang","year":"2017","journal-title":"Pain Physician"},{"issue":"Suppl 2","key":"R5-20260304","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1007\/s00586-018-5605-1","article-title":"Osteoporotic thoracolumbar compression fractures: long-term retrospective comparison between vertebroplasty and conservative treatment","volume":"27","author":"Martikos","year":"2018","journal-title":"Eur Spine J"},{"key":"R6-20260304","first-page":"44","article-title":"Diagnosis and management of vertebral compression fractures","volume":"94","author":"McCarthy","year":"2016","journal-title":"Am Fam Physician"},{"key":"R7-20260304","doi-asserted-by":"crossref","first-page":"3947368","DOI":"10.1155\/2020\/3947368","article-title":"Advances in vertebral augmentation systems for osteoporotic vertebral compression fractures","volume":"2020","author":"Long","year":"2020","journal-title":"Pain Res Manag"},{"key":"R8-20260304","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1007\/s00264-015-3102-2","article-title":"Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients","volume":"40","author":"Zhu","year":"2016","journal-title":"Int Orthop"},{"key":"R9-20260304","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1186\/s13018-019-1459-4","article-title":"Risk factors of neurological deficit and pulmonary cement embolism after percutaneous vertebroplasty","volume":"14","author":"Hsieh","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R10-20260304","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1186\/s13018-018-0952-5","article-title":"Balloon kyphoplasty versus percutaneous vertebroplasty for osteoporotic vertebral compression fracture: a meta-analysis and systematic review","volume":"13","author":"Wang","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R11-20260304","first-page":"175","article-title":"Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body","volume":"25","author":"Lin","year":"2004","journal-title":"AJNR Am J Neuroradiol"},{"key":"R12-20260304","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1007\/s00586-015-3786-4","article-title":"Risk factors of new symptomatic vertebral compression fractures in osteoporotic patients undergone percutaneous vertebroplasty","volume":"24","author":"Ren","year":"2015","journal-title":"Eur Spine J"},{"key":"R13-20260304","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.reuma.2019.11.006","article-title":"Asymptomatic pulmonary embolism secondary to cement leakage after vertebroplasty","volume":"17","author":"Arana-Guajardo","year":"2021","journal-title":"Reumatol Clin (Engl Ed)"},{"key":"R14-20260304","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1186\/s13018-021-02337-1","article-title":"Risk factors of postoperative bone cement leakage on osteoporotic vertebral compression fracture: a retrospective study","volume":"16","author":"Zhang","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"R15-20260304","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1186\/s12891-020-03810-4","article-title":"Risk factors for cement leakage and nomogram for predicting the intradiscal cement leakage after the vertebra augmented surgery","volume":"21","author":"Zhang","year":"2020","journal-title":"BMC Musculoskelet Disord"},{"key":"R16-20260304","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.spinee.2010.07.394","article-title":"Pulmonary cement embolization after kyphoplasty: a case report and review of the literature","volume":"10","author":"Radcliff","year":"2010","journal-title":"Spine J"},{"key":"R17-20260304","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.3174\/ajnr.A2127","article-title":"Percutaneous vertebroplasty and pulmonary cement embolism: results from VERTOS II","volume":"31","author":"Venmans","year":"2010","journal-title":"AJNR Am J Neuroradiol"},{"key":"R18-20260304","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1097\/01.BRS.0000128758.64381.75","article-title":"Anatomical and pathological considerations in percutaneous vertebroplasty and kyphoplasty: a reappraisal of the vertebral venous system","volume":"29","author":"Groen","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R19-20260304","doi-asserted-by":"crossref","first-page":"1227056","DOI":"10.3389\/fsurg.2023.1227056","article-title":"Case report: Inspiration from a rare fatal heart perforation after percutaneous vertebroplasty","volume":"10","author":"Deng","year":"2023","journal-title":"Front Surg"},{"key":"R20-20260304","doi-asserted-by":"crossref","first-page":"3000605221102088","DOI":"10.1177\/03000605221102088","article-title":"Life-threatening intracardiac cement embolisms after percutaneous kyphoplasty: a case report and literature review","volume":"50","author":"Huang","year":"2022","journal-title":"J Int Med Res"},{"key":"R21-20260304","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1111\/os.13192","article-title":"Cardiac perforation caused by cement embolism after percutaneous vertebroplasty: a report of two cases","volume":"14","author":"Zhang","year":"2022","journal-title":"Orthop Surg"},{"key":"R22-20260304","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1177\/0284185117732599","article-title":"Clinical outcome and subsequent sequelae of cement extravasation after percutaneous kyphoplasty and vertebroplasty: a comparative review","volume":"59","author":"Semaan","year":"2018","journal-title":"Acta Radiol"},{"key":"R23-20260304","doi-asserted-by":"crossref","first-page":"105906","DOI":"10.1016\/j.ijsu.2021.105906","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"88","author":"Page","year":"2021","journal-title":"Int J Surg"},{"key":"R24-20260304","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1002\/jbmr.5650080915","article-title":"Vertebral fracture assessment using a semiquantitative technique","volume":"8","author":"Genant","year":"1993","journal-title":"J Bone Miner Res"},{"key":"R25-20260304","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1186\/s12891-021-04685-9","article-title":"The impact of intravertebral cleft on cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a case-control study","volume":"22","author":"Tang","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"key":"R27-20260304","doi-asserted-by":"crossref","first-page":"E171","DOI":"10.1097\/BSD.0000000000000229","article-title":"Cement leakage in percutaneous vertebral augmentation for osteoporotic vertebral compression fractures: analysis of risk factors","volume":"29","author":"Xie","year":"2016","journal-title":"Clin Spine Surg"},{"key":"R28-20260304","doi-asserted-by":"crossref","first-page":"3411","DOI":"10.1007\/s00586-015-3923-0","article-title":"Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures","volume":"25","author":"Ding","year":"2016","journal-title":"Eur Spine J"},{"key":"R29-20260304","first-page":"E513","article-title":"Nomogram for predicting intradiscal cement leakage following percutaneous vertebroplasty in patients with osteoporotic related vertebral compression fractures","volume":"20","author":"Zhong","year":"2017","journal-title":"Pain Physician"},{"key":"R30-20260304","doi-asserted-by":"crossref","first-page":"e935080","DOI":"10.12659\/MSM.935080","article-title":"A retrospective study to evaluate the effect of dynamic fracture mobility on cement leakage in percutaneous vertebroplasty and percutaneous kyphoplasty in 286 patients with osteoporotic vertebral compression fractures","volume":"28","author":"Ren","year":"2022","journal-title":"Med Sci Monit"},{"key":"R31-20260304","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.neurad.2013.07.004","article-title":"Analysis of intradiscal cement leakage during percutaneous vertebroplasty: multivariate study of risk factors emphasizing preoperative MR findings","volume":"41","author":"Hong","year":"2014","journal-title":"J Neuroradiol"},{"key":"R32-20260304","doi-asserted-by":"crossref","first-page":"e9","DOI":"10.1097\/BSD.0b013e3181c0cc94","article-title":"Correlative factor analysis on the complications resulting from cement leakage after percutaneous kyphoplasty in the treatment of osteoporotic vertebral compression fracture","volume":"23","author":"Ren","year":"2010","journal-title":"J Spinal Disord Tech"},{"key":"R33-20260304","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1016\/j.spinee.2011.07.027","article-title":"Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors","volume":"11","author":"Nieuwenhuijse","year":"2011","journal-title":"Spine J"},{"key":"R34-20260304","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.1007\/s00586-021-07064-z","article-title":"Establishment and validation of a nomogram and web calculator for the risk of new vertebral compression fractures and cement leakage after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures","volume":"31","author":"Li","year":"2022","journal-title":"Eur Spine J"},{"key":"R35-20260304","first-page":"21925682231204159","article-title":"Interpretable machine learning model to predict bone cement leakage in percutaneous vertebral augmentation for osteoporotic vertebral compression fracture based on SHapley Additive exPlanations","volume":"3","author":"Hu","year":"2023","journal-title":"Global Spine J"},{"key":"R36-20260304","doi-asserted-by":"crossref","first-page":"1120","DOI":"10.1097\/01.brs.0000216461.48751.d6","article-title":"Intradiscal cement leak following percutaneous vertebroplasty","volume":"31","author":"Mirovsky","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R37-20260304","doi-asserted-by":"crossref","first-page":"e828","DOI":"10.1016\/j.wneu.2022.12.117","article-title":"Systematic retrospective analysis of risk factors and preventive measures of bone cement leakage in percutaneous kyphoplasty","volume":"171","author":"Li","year":"2023","journal-title":"World Neurosurg"},{"key":"R38-20260304","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1186\/s13018-019-1499-9","article-title":"Therapeutic effect of percutaneous kyphoplasty combined with anti-osteoporosis drug on postmenopausal women with osteoporotic vertebral compression fracture and analysis of postoperative bone cement leakage risk factors: a retrospective cohort study","volume":"14","author":"Huang","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R39-20260304","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1177\/2192568219830327","article-title":"Effects of polymethylmethacrylate cement viscosity and bone porosity on cement leakage and new vertebral fractures after percutaneous vertebroplasty: a prospective study","volume":"9","author":"Alhashash","year":"2019","journal-title":"Global Spine J"},{"key":"R40-20260304","doi-asserted-by":"crossref","first-page":"812023","DOI":"10.3389\/fpubh.2021.812023","article-title":"Machine learning applications for the prediction of bone cement leakage in percutaneous vertebroplasty","volume":"9","author":"Li","year":"2021","journal-title":"Front Public Health"},{"key":"R41-20260304","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1302\/0301-620X.85B1.13026","article-title":"Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures","volume":"85","author":"Yeom","year":"2003","journal-title":"J Bone Joint Surg Br"},{"key":"R42-20260304","doi-asserted-by":"crossref","first-page":"E693","DOI":"10.1097\/BRS.0000000000000294","article-title":"Identication of risk factors for the occurrence of cement leakage during percutaneous vertebroplasty for painful osteoporotic or malignant vertebral fracture","volume":"39","author":"Tome-Bermejo","year":"2014","journal-title":"Spine(Phila Pa 1976)"},{"key":"R43-20260304","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/00007632-200501010-00016","article-title":"Predictors of outcomes of percutaneous vertebroplasty for osteoporotic vertebral fractures","volume":"30","author":"Alvarez","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"R44-20260304","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1177\/0284185117725368","article-title":"Analysis of risk factors causing short-term cement leakages and long-term complications after percutaneous kyphoplasty for osteoporotic vertebral compression fractures","volume":"59","author":"Gao","year":"2018","journal-title":"Acta Radiol"},{"key":"R45-20260304","doi-asserted-by":"crossref","first-page":"1983","DOI":"10.1097\/01.brs.0000229254.89952.6b","article-title":"Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies","volume":"31","author":"Hulme","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R46-20260304","doi-asserted-by":"crossref","first-page":"E761","DOI":"10.1097\/BRS.0b013e3181fc914e","article-title":"The volumetric analysis of cement in vertebroplasty: relationship with clinical outcome and complications","volume":"36","author":"Jin","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"R47-20260304","doi-asserted-by":"crossref","first-page":"1979","DOI":"10.1111\/os.13025","article-title":"Comparison of intravertebral clefts between k\u00fcmmell disease and acute osteoporotic vertebral compression fracture: a radiological study","volume":"13","author":"Chen","year":"2021","journal-title":"Orthop Surg"},{"key":"R48-20260304","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.2214\/AJR.06.0903","article-title":"Cement leakage during vertebroplasty can be predicted on preoperative MRI","volume":"188","author":"Hiwatashi","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"R49-20260304","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.ijsu.2017.02.019","article-title":"The therapeutic effect of intravertebral vacuum cleft with osteoporotic vertebral compression fractures: a systematic review and meta-analysis","volume":"40","author":"Yu","year":"2017","journal-title":"Int J Surg"},{"key":"R50-20260304","doi-asserted-by":"crossref","first-page":"E589","DOI":"10.1097\/BRS.0b013e31814b84ba","article-title":"Delayed presentation of pulmonary polymethylmethacrylate emboli after percutaneous vertebroplasty","volume":"32","author":"Abdul-Jalil","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R51-20260304","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1007\/s00270-006-0133-5","article-title":"Complications in percutaneous vertebroplasty associated with puncture or cement leakage","volume":"30","author":"Baumann","year":"2007","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R52-20260304","doi-asserted-by":"crossref","first-page":"1551","DOI":"10.1016\/j.spinee.2013.09.025","article-title":"Basivertebral foramen could be connected with intravertebral cleft: a potential risk factor of cement leakage in percutaneous kyphoplasty","volume":"14","author":"Wang","year":"2014","journal-title":"Spine J"},{"key":"R53-20260304","doi-asserted-by":"crossref","first-page":"121","DOI":"10.3174\/ajnr.A2233","article-title":"The value of dynamic radiographs in diagnosing painful vertebrae in osteoporotic compression fractures","volume":"32","author":"Chen","year":"2011","journal-title":"AJNR Am J Neuroradiol"},{"key":"R54-20260304","doi-asserted-by":"crossref","first-page":"2517","DOI":"10.1097\/01.BRS.0000092424.29886.C9","article-title":"Reporting height restoration in vertebral compression fractures","volume":"28","author":"McKiernan","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"R55-20260304","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1359\/jbmr.2003.18.1.24","article-title":"The dynamic mobility of vertebral compression fractures","volume":"18","author":"McKiernan","year":"2003","journal-title":"J Bone Miner Res"},{"issue":"2 Pt 1","key":"R56-20260304","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/S1051-0443(07)61929-0","article-title":"Is intraosseous venography a significant safety measure in performance of vertebroplasty?","volume":"13","author":"Wong","year":"2002","journal-title":"J Vasc Interv Radiol"},{"key":"R57-20260304","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.wneu.2017.01.124","article-title":"Risk factors for cement leakage after vertebroplasty or kyphoplasty: a meta-analysis of published evidence","volume":"101","author":"Zhan","year":"2017","journal-title":"World Neurosurg"},{"key":"R58-20260304","doi-asserted-by":"crossref","first-page":"1559325816682867","DOI":"10.1177\/1559325816682867","article-title":"Is there a dose-response relationship of cement volume with cement leakage and pain relief after vertebroplasty?","volume":"14","author":"Fu","year":"2016","journal-title":"Dose Response"},{"key":"R59-20260304","doi-asserted-by":"crossref","first-page":"2721","DOI":"10.1016\/S0142-9612(03)00086-3","article-title":"Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure","volume":"24","author":"Bohner","year":"2003","journal-title":"Biomaterials"},{"key":"R60-20260304","doi-asserted-by":"crossref","first-page":"1352","DOI":"10.1097\/BRS.0b013e3181732aa9","article-title":"Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate","volume":"33","author":"Loeffel","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R61-20260304","doi-asserted-by":"crossref","first-page":"2562","DOI":"10.1097\/01.brs.0000240695.58651.62","article-title":"High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage","volume":"31","author":"Baroud","year":"2006","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000001895","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T12:05:02Z","timestamp":1772625902000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000001895"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,8]]},"references-count":60,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000001895","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,8]]},"assertion":[{"value":"2024-03-14","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-06-18","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}