{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,22]],"date-time":"2026-11-22T02:37:00Z","timestamp":1795315020798,"version":"4.10.3"},"reference-count":341,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T00:00:00Z","timestamp":1720656000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-sa\/4.0\/ http:\/\/creativecommons.org\/licenses\/by-sa\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>There have been many studies on human head\u2013neck biomechanical models in the last two decades, and the associated modelling techniques were constantly evolving at the same time. Computational approaches have been widely leveraged, in parallel to conventional physical tests, to investigate biomechanics and injuries of the head\u2013neck system in fields like the automotive industry, orthopedic, sports medicine, etc. The purpose of this manuscript is to provide a global review of the existing knowledge related to the modelling approaches, structural and biomechanical characteristics, validation, and application of the present head\u2013neck models. This endeavor aims to support further enhancements and validations in modelling practices, particularly addressing the lack of data for model validation, as well as to prospect future advances in terms of the topics. Seventy-four models subject to the proposed selection criteria are considered. Based on previously established and validated head\u2013neck computational models, most of the studies performed in-depth investigations of included cases, which revolved around four specific subjects: physiopathology, treatment evaluation, collision condition, and sports injury. Through the review of the recent 20 years of research, the summarized modelling information indicated existing deficiencies and future research topics, as well as provided references for subsequent head\u2013neck model development and application.<\/jats:p>","DOI":"10.1097\/js9.0000000000001941","type":"journal-article","created":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T12:04:26Z","timestamp":1720699466000},"page":"1042-1070","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Human head\u2013neck model and its application thresholds: a narrative review"],"prefix":"10.1097","volume":"111","author":[{"given":"Ziyang","family":"Liang","sequence":"first","affiliation":[{"name":"State Key Laboratory of Advanced Design and Manufacturing Technology for Vehicle, Hunan University"},{"name":"Xiangjiang Laboratory, Changsha, Hunan"},{"name":"Department of Tuina and Spinal Orthopedics in Chinese Medicine, Shenzhen Traditional Chinese Medicine Hospital, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, Guangdong, People\u2019s Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ke","family":"Wu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Advanced Design and Manufacturing Technology for Vehicle, Hunan University"},{"name":"Xiangjiang Laboratory, Changsha, Hunan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tengfei","family":"Tian","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Advanced Design and Manufacturing Technology for Vehicle, Hunan University"},{"name":"Xiangjiang Laboratory, Changsha, Hunan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fuhao","family":"Mo","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Advanced Design and Manufacturing Technology for Vehicle, Hunan University"},{"name":"Xiangjiang Laboratory, Changsha, Hunan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,1]]},"reference":[{"key":"R1-20260304","first-page":"0148","article-title":"Application of finite element techniques to the study of cervical spine mechanics","volume":"48","author":"Kleinberger","year":"1993","journal-title":"SAE Tech Pap"},{"key":"R2-20260304","first-page":"0148","article-title":"Development of a finite element model of the neck","volume":"103","author":"Dauvilliers","year":"1994","journal-title":"SAE Tech Pap"},{"key":"R3-20260304","first-page":"0148","article-title":"Development of a finite element model of the human neck","volume":"42","author":"Yang","year":"1998","journal-title":"SAE Tech Pap"},{"key":"R4-20260304","article-title":"Modeling of the human cervical spine using finite element techniques","author":"Li","year":"1999","journal-title":"SAE Tech Pap"},{"key":"R5-20260304","first-page":"127","article-title":"Investigation of conditions that affect neck compression-flexion injuries using numerical techniques","volume":"44","author":"Halldin","year":"2000","journal-title":"Stapp Car Crash J"},{"key":"R6-20260304","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1080\/10255842.2022.2124860","article-title":"Effects of different helmet-mounted devices on pilot\u2019s neck injury under simulated ejection","volume":"26","author":"Liu","year":"2023","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"R7-20260304","first-page":"37","article-title":"Determination of helmet CG and evaluation of neck injury potentials using \u201cKnox Box criteria\u201d and neck torque limits","volume":"57","author":"Gaur","year":"2013","journal-title":"IJASM"},{"key":"R8-20260304","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.1109\/LRA.2017.2671409","article-title":"Kinematic design of a dynamic brace for measurement of head\/neck motion","volume":"2","author":"Zhang","year":"2017","journal-title":"IEEE Robot Autom Let"},{"key":"R9-20260304","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1109\/LRA.2017.2728858","article-title":"An active neck brace controlled by a joystick to assist head motion","volume":"3","author":"Zhang","year":"2018","journal-title":"IEEE Robot Autom Let"},{"key":"R10-20260304","doi-asserted-by":"crossref","first-page":"110971","DOI":"10.1016\/j.exger.2020.110971","article-title":"Long-term assessment of morphological, functional, and quantitative parameters of skeletal muscle in older patients after unilateral total hip arthroplasty","volume":"137","author":"Yoshiko","year":"2020","journal-title":"Exp Gerontol"},{"key":"R11-20260304","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.1017\/wtc.2024.3","article-title":"A novel neck brace to characterize neck mobility impairments following neck dissection in head and neck cancer patients \u2013 ADDENDUM","volume":"5","author":"Chang","year":"2024","journal-title":"Wearable Technol"},{"key":"R12-20260304","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1186\/s12891-020-3103-1","article-title":"Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary?","volume":"21","author":"Liang","year":"2020","journal-title":"BMC Musculoskelet Disord"},{"key":"R13-20260304","doi-asserted-by":"crossref","first-page":"1710","DOI":"10.1111\/os.12797","article-title":"Finite element analysis of insertion angle of absorbable screws for the fixation of radial head fractures","volume":"12","author":"Xu","year":"2020","journal-title":"Orthop Surg"},{"key":"R14-20260304","doi-asserted-by":"crossref","first-page":"061005","DOI":"10.1115\/1.4032966","article-title":"A female ligamentous cervical spine finite element model validated for physiological loads","volume":"138","author":"Osth","year":"2016","journal-title":"J Biomech Eng"},{"key":"R15-20260304","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1080\/15389580802381954","article-title":"Research study on neck injury lessening with active head restraint using human body FE model","volume":"9","author":"Kitagawa","year":"2008","journal-title":"Traffic Inj Prev"},{"issue":"suppl 1","key":"R16-20260304","doi-asserted-by":"crossref","first-page":"S49","DOI":"10.1080\/15389588.2015.1021418","article-title":"Development of a computationally efficient full human body finite element model","volume":"16","author":"Schwartz","year":"2015","journal-title":"Traffic Inj Prev"},{"key":"R17-20260304","first-page":"509","article-title":"Development and full body validation of a 5th percentile female finite element model","volume":"60","author":"Davis","year":"2016","journal-title":"Stapp Car Crash J"},{"key":"R18-20260304","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1097\/BRS.0b013e3181f5cb87","article-title":"Comparison of cervical spine biomechanics after fixed- and mobile-core artificial disc replacement: a finite element analysis","volume":"36","author":"Lee","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"R19-20260304","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1016\/j.clinbiomech.2015.08.013","article-title":"Influence of sagittal and axial types of ossification of posterior longitudinal ligament on mechanical stress in cervical spinal cord: a finite element analysis","volume":"30","author":"Khuyagbaatar","year":"2015","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R21-20260304","doi-asserted-by":"crossref","first-page":"467","DOI":"10.5312\/wjo.v12.i7.467","article-title":"Technological advancements in the analysis of human motion and posture management through digital devices","volume":"12","author":"Roggio","year":"2021","journal-title":"World J Orthop"},{"key":"R22-20260304","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jbiomech.2017.05.005","article-title":"Dynamic head-neck stabilization and modulation with perturbation bandwidth investigated using a multisegment neuromuscular model","volume":"58","author":"Happee","year":"2017","journal-title":"J Biomech"},{"key":"R23-20260304","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1016\/j.jbiomech.2015.10.035","article-title":"Fundamental biomechanics of the spine--What we have learned in the past 25 years and future directions","volume":"49","author":"Oxland","year":"2016","journal-title":"J Biomech"},{"key":"R24-20260304","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1093\/tse\/tdz012","article-title":"A review of neck injury and protection in vehicle accidents","volume":"1","author":"Li","year":"2019","journal-title":"Transp Saf Environ"},{"key":"R25-20260304","doi-asserted-by":"crossref","first-page":"1658","DOI":"10.1016\/j.jbiomech.2016.03.052","article-title":"Joint kinematic calculation based on clinical direct kinematic versus inverse kinematic gait models","volume":"49","author":"Kainz","year":"2016","journal-title":"J Biomech"},{"key":"R26-20260304","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.gaitpost.2021.02.016","article-title":"Impact of scaling errors of the thigh and shank segments on musculoskeletal simulation results","volume":"87","author":"Koller","year":"2021","journal-title":"Gait Posture"},{"key":"R27-20260304","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/s10237-003-0036-1","article-title":"Anatomically based geometric modelling of the musculo-skeletal system and other organs","volume":"2","author":"Fernandez","year":"2004","journal-title":"Biomech Model Mechanobiol"},{"key":"R28-20260304","doi-asserted-by":"crossref","first-page":"2778","DOI":"10.1016\/j.jbiomech.2013.09.005","article-title":"Subject-specific knee joint geometry improves predictions of medial tibiofemoral contact forces","volume":"46","author":"Gerus","year":"2013","journal-title":"J Biomech"},{"key":"R29-20260304","doi-asserted-by":"crossref","first-page":"3444","DOI":"10.1109\/TBME.2019.2905956","article-title":"Improving musculoskeletal model scaling using an anatomical atlas: the importance of gender and anthropometric similarity to quantify joint reaction forces","volume":"66","author":"Ding","year":"2019","journal-title":"IEEE Trans Biomed Eng"},{"key":"R30-20260304","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1007\/s10237-019-01245-y","article-title":"Best methods and data to reconstruct paediatric lower limb bones for musculoskeletal modelling","volume":"19","author":"Davico","year":"2020","journal-title":"Biomech Model Mechanobiol"},{"key":"R31-20260304","doi-asserted-by":"crossref","first-page":"1940","DOI":"10.1109\/TBME.2007.901024","article-title":"OpenSim: open-source software to create and analyze dynamic simulations of movement","volume":"54","author":"Delp","year":"2007","journal-title":"IEEE Trans Biomed Eng"},{"key":"R32-20260304","doi-asserted-by":"crossref","first-page":"021019","DOI":"10.1115\/1.4032127","article-title":"Influence of the level of muscular redundancy on the validity of a musculoskeletal model","volume":"138","author":"Moissenet","year":"2016","journal-title":"J Biomech Eng"},{"key":"R33-20260304","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1007\/s10439-019-02207-2","article-title":"Anthropometric scaling of anatomical datasets for subject-specific musculoskeletal modelling of the shoulder","volume":"47","author":"Klemt","year":"2019","journal-title":"Ann Biomed Eng"},{"key":"R34-20260304","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0021-9290(98)00158-4","article-title":"Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints","volume":"32","author":"Lu","year":"1999","journal-title":"J Biomech"},{"key":"R35-20260304","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1016\/j.jbiomech.2013.12.010","article-title":"Evaluation of a morphing based method to estimate muscle attachment sites of the lower extremity","volume":"47","author":"Pellikaan","year":"2014","journal-title":"J Biomech"},{"key":"R36-20260304","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1080\/15389580590903203","article-title":"The effect of muscle activation on neck response","volume":"6","author":"Brolin","year":"2005","journal-title":"Traffic Inj Prev"},{"key":"R38-20260304","doi-asserted-by":"crossref","first-page":"106761","DOI":"10.1016\/j.cmpb.2022.106761","article-title":"Quantitative cervical spine injury responses in whiplash loading with a numerical method of natural neural reflex consideration","volume":"219","author":"Liang","year":"2022","journal-title":"Comput Methods Programs Biomed"},{"key":"R39-20260304","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1243\/095441104323118905","article-title":"Prediction of inter-segment stability and osteophyte formation on the multi-segment C2-C7 after unilateral and bilateral facetectomy","volume":"218","author":"Ng","year":"2004","journal-title":"Proc Inst Mech Eng H"},{"key":"R40-20260304","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.jbiomech.2004.10.029","article-title":"Finite element analysis of moment-rotation relationships for human cervical spine","volume":"39","author":"Zhang","year":"2006","journal-title":"J Biomech"},{"key":"R41-20260304","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.jbiomech.2007.10.012","article-title":"An accurate finite element model of the cervical spine under quasi-static loading","volume":"41","author":"del Palomar","year":"2008","journal-title":"J Biomech"},{"key":"R42-20260304","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1080\/14763140802630006","article-title":"A cervical spine model to predict injury scenarios and clinical instability","volume":"8","author":"Tchako","year":"2009","journal-title":"Sports Biomech"},{"key":"R43-20260304","article-title":"HUMOS: human model for safety~ a joint effort towards the development of refined human-like car occupant models","author":"Robin","year":"2001","journal-title":"SAE Tech Pap"},{"key":"R44-20260304","first-page":"177","article-title":"Human neck finite element model development and validation against original experimental data","volume":"48","author":"Meyer","year":"2004","journal-title":"Stapp Car Crash J"},{"key":"R47-20260304","doi-asserted-by":"crossref","first-page":"20190086","DOI":"10.1098\/rsif.2019.0086","article-title":"Passive cervical spine ligaments provide stability during head impacts","volume":"16","author":"Kuo","year":"2019","journal-title":"J R Soc Interface"},{"key":"R48-20260304","doi-asserted-by":"crossref","first-page":"3177","DOI":"10.1016\/j.jbiomech.2008.08.025","article-title":"Predictive modelling of cervical disc implant wear","volume":"41","author":"de Jongh","year":"2008","journal-title":"J Biomech"},{"key":"R49-20260304","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.clinbiomech.2020.02.008","article-title":"Numerical investigation of the relative effect of disc bulging and ligamentum flavum hypertrophy on the mechanism of central cord syndrome","volume":"74","author":"Bailly","year":"2020","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R50-20260304","doi-asserted-by":"crossref","first-page":"110077","DOI":"10.1016\/j.jbiomech.2020.110077","article-title":"Febio finite element models of the human cervical spine","volume":"113","author":"Herron","year":"2020","journal-title":"J Biomech"},{"key":"R51-20260304","doi-asserted-by":"crossref","first-page":"154","DOI":"10.3389\/fbioe.2020.00154","article-title":"Optimization of three-level cervical hybrid surgery to prevent adjacent segment disease: a finite element study","volume":"8","author":"Wong","year":"2020","journal-title":"Front Bioeng Biotechnol"},{"key":"R52-20260304","doi-asserted-by":"crossref","first-page":"7645","DOI":"10.3390\/app11167645","article-title":"Biomechanical analysis of posterior ligaments of cervical spine and laminoplasty","volume":"11","author":"Nishida","year":"2021","journal-title":"Appl Sci"},{"key":"R53-20260304","doi-asserted-by":"crossref","first-page":"105475","DOI":"10.1016\/j.compbiomed.2022.105475","article-title":"A finite element study on the effects of follower load on the continuous biomechanical responses of subaxial cervical spine","volume":"145","author":"Sun","year":"2022","journal-title":"Comput Biol Med"},{"key":"R54-20260304","doi-asserted-by":"crossref","first-page":"2152","DOI":"10.1007\/s10439-011-0315-4","article-title":"Cervical spine model to predict capsular ligament response in rear impact","volume":"39","author":"Fice","year":"2011","journal-title":"Ann Biomed Eng"},{"key":"R55-20260304","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.1016\/j.jbiomech.2009.04.007","article-title":"Parametric and subject-specific finite element modelling of the lower cervical spine. Influence of geometrical parameters on the motion patterns","volume":"42","author":"Laville","year":"2009","journal-title":"J Biomech"},{"key":"R56-20260304","doi-asserted-by":"crossref","first-page":"1645","DOI":"10.1007\/s10439-021-02783-2","article-title":"Vestibulocollic and cervicocollic muscle reflexes in a finite element neck model during multidirectional impacts","volume":"49","author":"Correia","year":"2021","journal-title":"Ann Biomed Eng"},{"key":"R57-20260304","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s10439-020-02512-1","article-title":"Optimization of female head-neck model with active reflexive cervical muscles in low severity rear impact collisions","volume":"49","author":"Putra","year":"2021","journal-title":"Ann Biomed Eng"},{"key":"R58-20260304","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1109\/TNSRE.2021.3095624","article-title":"A novel neuromuscular head-neck model and its application on impact analysis","volume":"29","author":"Zheng","year":"2021","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"R59-20260304","doi-asserted-by":"crossref","first-page":"7289648","DOI":"10.1155\/2020\/7289648","article-title":"Application of simulation methods in cervical spine dynamics","volume":"2020","author":"Sun","year":"2020","journal-title":"J Healthc Eng"},{"key":"R60-20260304","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.compmedimag.2006.09.004","article-title":"Intervertebral disc biomechanical analysis using the finite element modeling based on medical images","volume":"30","author":"Li","year":"2006","journal-title":"Comput Med Imaging Graph"},{"key":"R61-20260304","doi-asserted-by":"crossref","first-page":"13","DOI":"10.14444\/2013","article-title":"Role of posterior elements in the disc bulging of a degenerated cervical spine","volume":"9","author":"Amirouche","year":"2015","journal-title":"Int J Spine Surg"},{"key":"R62-20260304","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1080\/10255842.2020.1767776","article-title":"Contribution of injured posterior ligamentous complex and intervertebral disc on post-traumatic instability at the cervical spine","volume":"23","author":"Beaus\u00e9jour","year":"2020","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R63-20260304","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1177\/0954411916637383","article-title":"Effect of posterior decompression extent on biomechanical parameters of the spinal cord in cervical ossification of the posterior longitudinal ligament","volume":"230","author":"Khuyagbaatar","year":"2016","journal-title":"Proc Inst Mech Eng H"},{"key":"R64-20260304","doi-asserted-by":"crossref","first-page":"772853","DOI":"10.3389\/fbioe.2021.772853","article-title":"Comparative analysis of the biomechanical characteristics after different minimally invasive surgeries for cervical spondylopathy: a finite element analysis","volume":"9","author":"He","year":"2021","journal-title":"Front Bioeng Biotechnol"},{"key":"R65-20260304","doi-asserted-by":"crossref","first-page":"100070","DOI":"10.1016\/j.medntd.2021.100070","article-title":"A critical review on the biomechanical study of cervical interbody fusion cage","volume":"11","author":"Huang","year":"2021","journal-title":"Med Nov Technol Devices"},{"key":"R66-20260304","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1080\/10255842.2020.1765162","article-title":"Percutaneous posterior full-endoscopic cervical foraminotomy and discectomy: a finite element analysis and radiological assessment","volume":"23","author":"Ke","year":"2020","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R67-20260304","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1097\/01.BRS.0000134574.36487.EB","article-title":"Biomechanical effects of C2-C7 intersegmental stability due to laminectomy with unilateral and bilateral facetectomy","volume":"29","author":"Hong-Wan","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R68-20260304","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1080\/13588265.2012.732293","article-title":"Development and validation of a coupled head-neck FEM \u2013 application to whiplash injury criteria investigation","volume":"18","author":"Meyer","year":"2013","journal-title":"Int J Crashworthiness"},{"key":"R69-20260304","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1533\/ijcr.2005.0384","article-title":"Evaluation of head injury criteria using a finite element model validated against experiments on localized brain motion, intracerebral acceleration, and intracranial pressure","volume":"11","author":"Kleiven","year":"2006","journal-title":"Int J Crashworthiness"},{"key":"R70-20260304","doi-asserted-by":"crossref","first-page":"E236","DOI":"10.1097\/BRS.0b013e31816b8812","article-title":"How does a three-dimensional continuum muscle model affect the kinematics and muscle strains of a finite element neck model compared to a discrete muscle model in rear-end, frontal, and lateral impacts","volume":"33","author":"Hedenstierna","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R71-20260304","doi-asserted-by":"crossref","first-page":"2626","DOI":"10.1097\/BRS.0b013e3181b46bdd","article-title":"Neck muscle load distribution in lateral, frontal, and rear-end impacts: a three-dimensional finite element analysis","volume":"34","author":"Hedenstierna","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"R72-20260304","doi-asserted-by":"crossref","DOI":"10.4271\/760800","article-title":"The effect of duration, rate of onset, and peak sled acceleration on the dynamic response of the human head and neck","author":"Ewing","year":"1976","journal-title":"SAE Tech Pap"},{"key":"R73-20260304","doi-asserted-by":"crossref","first-page":"2692","DOI":"10.1097\/00007632-200112150-00012","article-title":"Mechanical properties of the human cervical spine as shown by three-dimensional load-displacement curves","volume":"26","author":"Panjabi","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R74-20260304","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/0021-9290(88)90285-0","article-title":"Load-displacement properties of lower cervical spine motion segments","volume":"21","author":"Moroney","year":"1988","journal-title":"J Biomech"},{"key":"R75-20260304","doi-asserted-by":"crossref","DOI":"10.4271\/680792","article-title":"Dynamic response of the head and neck of the living human to\u2014G x impact acceleration","author":"Ewing","year":"1968","journal-title":"SAE Tech Pap"},{"key":"R76-20260304","article-title":"Dynamic response of the human head and neck to+ Gy impact acceleration","author":"Ewing","year":"1977","journal-title":"SAE Tech Pap"},{"key":"R77-20260304","first-page":"819","article-title":"Omni-directional human head-neck response","volume":"95","author":"Wismans","year":"1986","journal-title":"SAE trans"},{"key":"R78-20260304","first-page":"3906","article-title":"Biofidelity of anthropomorphic test devices for rear impact","volume":"106","author":"Prasad","year":"1997","journal-title":"SAE trans"},{"key":"R79-20260304","article-title":"Cervical spine stiffness and geometry of the young human male","author":"Liu","year":"1982","journal-title":"Tulane Univ New Orleans La School Med"},{"key":"R81-20260304","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/00002517-199106000-00005","article-title":"Flexion, extension, and lateral bending of the upper cervical spine in response to alar ligament transections","volume":"4","author":"Panjabi","year":"1991","journal-title":"J Spinal Disord"},{"key":"R82-20260304","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1097\/00007632-199015100-00002","article-title":"Ligamentous laxity across C0-C1-C2 complex. Axial torque-rotation characteristics until failure","volume":"15","author":"Goel","year":"1990","journal-title":"Spine (Phila Pa 1976)"},{"key":"R83-20260304","first-page":"85","article-title":"Tensile properties of the human muscular and ligamentous cervical spine","volume":"44","author":"Van Ee","year":"2000","journal-title":"Stapp Car Crash J"},{"key":"R84-20260304","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1097\/01.BRS.0000090820.99182.2D","article-title":"Development of a finite element model of the upper cervical spine and a parameter study of ligament characteristics","volume":"29","author":"Brolin","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R85-20260304","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/0021-9290(95)00056-9","article-title":"Dynamic responses of the head and cervical spine to axial impact loading","volume":"29","author":"Nightingale","year":"1996","journal-title":"J Biomech"},{"key":"R91-20260304","first-page":"3859","article-title":"Cervical injury mechanism based on the analysis of human cervical vertebral motion and head-neck-torso kinematics during low speed rear impacts","volume":"106","author":"Ono","year":"1997","journal-title":"SAE Trans"},{"key":"R92-20260304","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.1097\/01.BRS.0000135840.92373.5C","article-title":"Using a finite element model to evaluate human injuries application to the HUMOS model in whiplash situation","volume":"29","author":"Tropiano","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R93-20260304","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1115\/1.1835364","article-title":"Influence of cervical disc degeneration after posterior surgical techniques in combined flexion-extension \u2013 a nonlinear analytical study","volume":"127","author":"Ng","year":"2005","journal-title":"J Biomech Eng"},{"key":"R94-20260304","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.jmbbm.2018.09.043","article-title":"Forces and moments in cervical spinal column segments in frontal impacts using finite element modeling and human cadaver tests","volume":"90","author":"Meyer","year":"2019","journal-title":"J Mech Behav Biomed Mater"},{"key":"R95-20260304","doi-asserted-by":"crossref","first-page":"104318","DOI":"10.1016\/j.jmbbm.2021.104318","article-title":"Development of a detailed human neck finite element model and injury risk curves under lateral impact","volume":"116","author":"Meyer","year":"2021","journal-title":"J Mech Behav Biomed Mater"},{"key":"R96-20260304","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1080\/10255840600980940","article-title":"Finite element model of the human neck during omni-directional impacts. Part II: relation between cervical curvature and risk of injury","volume":"9","author":"Frechede","year":"2006","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"R97-20260304","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1243\/09544119JEIM209","article-title":"Finite element analysis of head-neck kinematics under simulated rear impact at different accelerations","volume":"222","author":"Zhang","year":"2008","journal-title":"Proc Inst Mech Eng H"},{"key":"R98-20260304","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1243\/09544119JEIM367","article-title":"A numerical study of the effect of axial acceleration on the responses of the cervical spine during low-speed rear-end impact","volume":"222","author":"Zhang","year":"2008","journal-title":"Proc Inst Mech Eng H"},{"key":"R99-20260304","doi-asserted-by":"crossref","DOI":"10.4271\/2009-01-2266","article-title":"Development of a human FE model with 3-D geometry of muscles and lateral impact analysis for the arm with muscle activity","author":"Iwamoto","year":"2009","journal-title":"SAE Tech Pap"},{"key":"R100-20260304","first-page":"231","article-title":"Development of a human body finite element model with multiple muscles and their controller for estimating occupant motions and impact responses in frontal crash situations","volume":"56","author":"Iwamoto","year":"2012","journal-title":"Stapp Car Crash J"},{"key":"R102-20260304","doi-asserted-by":"crossref","first-page":"2684","DOI":"10.1097\/00007632-199812150-00007","article-title":"Cervical spine models for biomechanical research","volume":"23","author":"Panjabi","year":"1998","journal-title":"Spine (Phila Pa 1976)"},{"key":"R103-20260304","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1007\/s005860050112","article-title":"Whiplash injuries and the potential for mechanical instability","volume":"7","author":"Panjabi","year":"1998","journal-title":"Eur Spine J"},{"key":"R104-20260304","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1097\/00007632-198807000-00003","article-title":"Three-dimensional movements of the upper cervical spine","volume":"13","author":"Panjabi","year":"1988","journal-title":"Spine (Phila Pa 1976)"},{"key":"R105-20260304","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/0021-9290(84)90030-7","article-title":"An in-vitro study of the kinematics of the normal, injured and stabilized cervical spine","volume":"17","author":"Goel","year":"1984","journal-title":"J Biomech"},{"key":"R106-20260304","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/0021-9290(88)90204-7","article-title":"Moment-rotation relationships of the ligamentous occipito-atlanto-axial complex","volume":"21","author":"Goel","year":"1988","journal-title":"J Biomech"},{"key":"R107-20260304","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1097\/00007632-199803150-00008","article-title":"Prediction of load sharing among spinal components of a C5-C6 motion segment using the finite element approach","volume":"23","author":"Goel","year":"1998","journal-title":"Spine (Phila Pa 1976)"},{"key":"R108-20260304","doi-asserted-by":"crossref","first-page":"1694","DOI":"10.1016\/j.jbiomech.2004.07.015","article-title":"Evaluation of the intervertebral neck injury criterion using simulated rear impacts","volume":"38","author":"Panjabi","year":"2005","journal-title":"J Biomech"},{"key":"R109-20260304","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1115\/1.1992527","article-title":"Development and validation of a CO-C7 FE complex for biomechanical study","volume":"127","author":"Zhang","year":"2005","journal-title":"J Biomech Eng"},{"key":"R110-20260304","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/S0021-9290(98)00178-X","article-title":"Surface friction in near-vertex head and neck impact increases risk of injury","volume":"32","author":"Camacho","year":"1999","journal-title":"J Biomech"},{"key":"R111-20260304","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1007\/BF02344708","article-title":"Validation of a head-neck computer model for whiplash simulation","volume":"42","author":"Stemper","year":"2004","journal-title":"Med Biol Eng Comput"},{"key":"R112-20260304","first-page":"1645","article-title":"Development of a finite element model of the neck","volume":"103","author":"Dauvilliers","year":"1994","journal-title":"SAE Trans"},{"key":"R115-20260304","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.jbiomech.2004.11.014","article-title":"Experimental flexion\/extension data corridors for validation of finite element models of the young, normal cervical spine","volume":"39","author":"Wheeldon","year":"2006","journal-title":"J Biomech"},{"key":"R116-20260304","doi-asserted-by":"crossref","DOI":"10.4271\/730976","article-title":"Torque versus angular displacement response of human head to-Gx impact acceleration","author":"Ewing","year":"1973","journal-title":"SAE Tech Pap"},{"key":"R117-20260304","first-page":"1323","article-title":"Comparison of human volunteer and cadaver head-neck response in frontal flexion","volume":"96","author":"Wismans","year":"1987","journal-title":"SAE Trans"},{"key":"R118-20260304","first-page":"329","article-title":"Comparison of kinematic responses of the head and spine for children and adults in low-speed frontal sled tests","volume":"53","author":"Arbogast","year":"2009","journal-title":"Stapp Car Crash J"},{"key":"R120-20260304","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1097\/00007632-199808010-00006","article-title":"A kinematic study of the cervical spine before and after segmental arthrodesis","volume":"23","author":"Fuller","year":"1998","journal-title":"Spine (Phila Pa 1976)"},{"key":"R121-20260304","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1177\/036354659602400407","article-title":"The effect of protective football equipment on alignment of the injured cervical spine. Radiographic analysis in a cadaveric model","volume":"24","author":"Palumbo","year":"1996","journal-title":"Am J Sports Med"},{"key":"R122-20260304","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.medengphy.2006.01.007","article-title":"Finite element analysis of head-neck kinematics during motor vehicle accidents: analysis in multiple planes","volume":"29","author":"Teo","year":"2007","journal-title":"Med Eng Phys"},{"key":"R123-20260304","doi-asserted-by":"crossref","first-page":"051013","DOI":"10.1115\/1.3118763","article-title":"Stress changes in intervertebral discs of the cervical spine due to partial discectomies and fusion","volume":"131","author":"Tchako","year":"2009","journal-title":"J Biomech Eng"},{"key":"R124-20260304","doi-asserted-by":"crossref","first-page":"2875","DOI":"10.1016\/j.jbiomech.2010.07.027","article-title":"Computational analysis of bone remodeling during an anterior cervical fusion","volume":"43","author":"Espinha","year":"2010","journal-title":"J Biomech"},{"key":"R125-20260304","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.medengphy.2010.03.001","article-title":"Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data","volume":"32","author":"Kallemeyn","year":"2010","journal-title":"Med Eng Phys"},{"key":"R126-20260304","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.medengphy.2010.02.009","article-title":"Influence of surgical treatment for disc degeneration disease at C5-C6 on changes in some biomechanical parameters of the cervical spine","volume":"32","author":"Li","year":"2010","journal-title":"Med Eng Phys"},{"key":"R127-20260304","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1016\/j.scient.2011.10.002","article-title":"Generating a finite element model of the cervical spine: Estimating muscle forces and internal loads","volume":"18","author":"Toosizadeh","year":"2011","journal-title":"Scientia Iranica"},{"key":"R128-20260304","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.1097\/BRS.0b013e31815e62ea","article-title":"Influence of the geometry of a ball-and-socket intervertebral prosthesis at the cervical spine: a finite element study","volume":"33","author":"Rousseau","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R129-20260304","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.2106\/JBJS.F.00200","article-title":"Level-dependent coronal and axial moment-rotation corridors of degeneration-free cervical spines in lateral flexion","volume":"89","author":"Yoganandan","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"R130-20260304","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1097\/BRS.0b013e3181657f67","article-title":"Normative segment-specific axial and coronal angulation corridors of subaxial cervical column in axial rotation","volume":"33","author":"Yoganandan","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R131-20260304","first-page":"2040","article-title":"The influence of end condition on human cervical spine injury mechanisms","volume":"100","author":"Nightingale","year":"1991","journal-title":"SAE Trans"},{"key":"R132-20260304","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1016\/j.jbiomech.2006.02.015","article-title":"Flexion and extension structural properties and strengths for male cervical spine segments","volume":"40","author":"Nightingale","year":"2007","journal-title":"J Biomech"},{"key":"R133-20260304","first-page":"150","article-title":"The effect of multi-level laminoplasty and laminectomy on the biomechanics of the cervical spine: a finite element study","volume":"34","author":"Kode","year":"2014","journal-title":"Iowa Orthop J"},{"key":"R134-20260304","doi-asserted-by":"crossref","first-page":"491","DOI":"10.14444\/6066","article-title":"Biomechanical analysis of the cervical spine following disc degeneration, disc fusion, and disc replacement: a finite element study","volume":"13","author":"Gandhi","year":"2019","journal-title":"Int J Spine Surg"},{"key":"R135-20260304","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.clinbiomech.2020.02.009","article-title":"A comprehensive finite element model of surgical treatment for cervical myelopathy","volume":"74","author":"Stoner","year":"2020","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R136-20260304","first-page":"633","article-title":"Influence of assigned material combination in a simulated total cervical disc replacement design on kinematics of a model of the full cervical spine: a finite element analysis study","volume":"27","author":"Qi","year":"2016","journal-title":"Biomed Mater Eng"},{"key":"R137-20260304","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1016\/j.medengphy.2011.05.004","article-title":"Cervical spine response in frontal crash","volume":"33","author":"Panzer","year":"2011","journal-title":"Med Eng Phys"},{"key":"R138-20260304","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1007\/s11517-010-0708-9","article-title":"A three-dimensional finite element model of the cervical spine: an investigation of whiplash injury","volume":"49","author":"Zhang","year":"2011","journal-title":"Med Biol Eng Comput"},{"key":"R139-20260304","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.phpro.2011.11.064","article-title":"Effects of lateral mass screw rod fixation to the stability of cervical spine after laminectomy","volume":"22","author":"Rosli","year":"2011","journal-title":"Phys Proc"},{"key":"R140-20260304","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1007\/s11517-012-0908-6","article-title":"Finite element analysis of the influence of loading rate on a model of the full lumbar spine under dynamic loading conditions","volume":"50","author":"Wagnac","year":"2012","journal-title":"Med Biol Eng Comput"},{"key":"R141-20260304","doi-asserted-by":"crossref","first-page":"2395","DOI":"10.1097\/01.brs.0000143173.92241.ab","article-title":"Cervical spine ligament injury during simulated frontal impact","volume":"29","author":"Panjabi","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R142-20260304","first-page":"8373","article-title":"Passenger air bag impact and injury response using a hybrid III test dummy and human surrogates: phase 2b","author":"Bolton","year":"2006","journal-title":"National Highway Traffic Safety Administration NHTSA Biomechanics Test Database"},{"key":"R143-20260304","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1080\/10286580008902576","article-title":"Human volunteer kinematics in rear-end sled collisions","volume":"2","author":"Davidsson","year":"2001","journal-title":"J Crash Prev Inj Contr"},{"key":"R145-20260304","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s00586-003-0590-3","article-title":"Injury of the anterior longitudinal ligament during whiplash simulation","volume":"13","author":"Ivancic","year":"2004","journal-title":"Eur Spine J"},{"key":"R146-20260304","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1097\/00007632-200406010-00011","article-title":"Injury mechanisms of the cervical intervertebral disc during simulated whiplash","volume":"29","author":"Panjabi","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R147-20260304","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1097\/01.BRS.0000090836.50508.F7","article-title":"Facet joint kinematics and injury mechanisms during simulated whiplash","volume":"29","author":"Pearson","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R148-20260304","doi-asserted-by":"crossref","first-page":"2095","DOI":"10.1097\/00007632-200110010-00010","article-title":"Mechanical evidence of cervical facet capsule injury during whiplash: a cadaveric study using combined shear, compression, and extension loading","volume":"26","author":"Siegmund","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R149-20260304","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/S0021-9290(02)00037-4","article-title":"Comparative strengths and structural properties of the upper and lower cervical spine in flexion and extension","volume":"35","author":"Nightingale","year":"2002","journal-title":"J Biomech"},{"key":"R150-20260304","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1097\/01.BRS.0000042246.09816.20","article-title":"Biomechanical evaluation of cervical double-door laminoplasty using hydroxyapatite spacer","volume":"28","author":"Kubo","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"R151-20260304","first-page":"117","article-title":"Cervical spine stabilization. A three-dimensional, biomechanical evaluation of rotational stability, strength, and failure mechanisms","volume":"16","author":"Pelker","year":"1991","journal-title":"Spine (Phila Pa 1976)"},{"key":"R152-20260304","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1007\/s00776-003-0675-1","article-title":"Effects of lumbar spinal fusion on the other lumbar intervertebral levels (three-dimensional finite element analysis)","volume":"8","author":"Goto","year":"2003","journal-title":"J Orthop Sci"},{"key":"R153-20260304","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1002\/jor.1100040203","article-title":"Three-dimensional load-displacement curves due to forces on the cervical spine","volume":"4","author":"Panjabi","year":"1986","journal-title":"J Orthop Res"},{"key":"R154-20260304","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1002\/jor.1100060514","article-title":"Analysis and measurement of neck loads","volume":"6","author":"Moroney","year":"1988","journal-title":"J Orthop Res"},{"key":"R155-20260304","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/j.jbiomech.2012.01.016","article-title":"Investigation of whiplash injuries in the upper cervical spine using a detailed neck model","volume":"45","author":"Fice","year":"2012","journal-title":"J Biomech"},{"key":"R156-20260304","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.jmbbm.2013.01.006","article-title":"Finite element modeling of potential cervical spine pain sources in neutral position low speed rear impact","volume":"33","author":"Cronin","year":"2014","journal-title":"J Mech Behav Biomed Mater"},{"key":"R157-20260304","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1080\/15389588.2014.1003551","article-title":"Out-of-Position Rear Impact Tissue-Level Investigation Using Detailed Finite Element Neck Model","volume":"16","author":"Shateri","year":"2015","journal-title":"Traffic Inj Prev"},{"key":"R158-20260304","doi-asserted-by":"crossref","first-page":"E893","DOI":"10.1097\/BRS.0000000000001468","article-title":"A biomechanical analysis of an artificial disc with a shock-absorbing core property by using whole-cervical spine finite element analysis","volume":"41","author":"Lee","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"R159-20260304","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1177\/0954411914527074","article-title":"Stability of cervical spine after one-level corpectomy using different numbers of screws and plate systems","volume":"228","author":"Rosli","year":"2014","journal-title":"Proc Inst Mech Eng H"},{"key":"R160-20260304","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s13246-013-0182-4","article-title":"Straightened cervical lordosis causes stress concentration: a finite element model study","volume":"36","author":"Wei","year":"2013","journal-title":"Austr Phys Eng Sci Med"},{"key":"R161-20260304","doi-asserted-by":"crossref","first-page":"2719","DOI":"10.1007\/s00586-013-2992-1","article-title":"Biomechanical comparison of laminectomy, hemilaminectomy and a new minimally invasive approach in the surgical treatment of multilevel cervical intradural tumour: a finite element analysis","volume":"22","author":"Xie","year":"2013","journal-title":"Eur Spine J"},{"key":"R162-20260304","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1016\/j.clinbiomech.2013.07.016","article-title":"Effect of the transverse ligament rupture on the biomechanics of the cervical spine under a compressive loading","volume":"28","author":"Mesfar","year":"2013","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R163-20260304","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1016\/j.medengphy.2014.02.020","article-title":"Application of an asymmetric finite element model of the C2-T1 cervical spine for evaluating the role of soft tissues in stability","volume":"36","author":"Erbulut","year":"2014","journal-title":"Med Eng Phys"},{"key":"R166-20260304","doi-asserted-by":"crossref","first-page":"081008","DOI":"10.1115\/1.3127257","article-title":"Tension and combined tension-extension structural response and tolerance properties of the human male ligamentous cervical spine","volume":"131","author":"Dibb","year":"2009","journal-title":"J Biomech Eng"},{"key":"R167-20260304","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1007\/s00586-004-0758-5","article-title":"Biofidelic whole cervical spine model with muscle force replication for whiplash simulation","volume":"14","author":"Ivancic","year":"2005","journal-title":"Eur Spine J"},{"key":"R168-20260304","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1007\/s00586-004-0783-4","article-title":"Cervical intervertebral disc injury during simulated frontal impact","volume":"14","author":"Ito","year":"2005","journal-title":"Eur Spine J"},{"key":"R169-20260304","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1080\/15389580500488499","article-title":"Predicting multiplanar cervical spine injury due to head-turned rear impacts using IV-NIC","volume":"7","author":"Ivancic","year":"2006","journal-title":"Traffic Inj Prev"},{"key":"R170-20260304","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.clinbiomech.2005.10.011","article-title":"Effect of rotated head posture on dynamic vertebral artery elongation during simulated rear impact","volume":"21","author":"Ivancic","year":"2006","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R171-20260304","first-page":"2007","article-title":"Dummy requirements and injury criteria for a low-speed rear impact whiplash dummy","volume":"505","author":"Hynd","year":"2007","journal-title":"Eur Enhanced Vehicle-Saf Committee"},{"key":"R172-20260304","first-page":"3065","article-title":"Human volunteer head-neck response in frontal flexion: a new analysis","volume":"104","author":"Thunnissen","year":"1995","journal-title":"SAE Trans"},{"key":"R173-20260304","doi-asserted-by":"crossref","first-page":"96","DOI":"10.3171\/jns.1993.79.1.0096","article-title":"Biomechanical comparison of anterior Caspar plate and three-level posterior fixation techniques in a human cadaveric model","volume":"79","author":"Traynelis","year":"1993","journal-title":"J Neurosurg"},{"key":"R174-20260304","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1080\/10255842.2013.792918","article-title":"Cross-sectional neck response of a total human body FE model during simulated frontal and side automobile impacts","volume":"18","author":"White","year":"2015","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"R175-20260304","doi-asserted-by":"crossref","first-page":"110528","DOI":"10.1016\/j.jbiomech.2021.110528","article-title":"Importance of the cervical capsular joint cartilage geometry on head and facet joint kinematics assessed in a finite element neck model","volume":"123","author":"Corrales","year":"2021","journal-title":"J Biomech"},{"key":"R176-20260304","doi-asserted-by":"crossref","first-page":"681134","DOI":"10.3389\/fbioe.2021.681134","article-title":"Sex, age and stature affects neck biomechanical responses in frontal and rear impacts assessed using finite element head and neck models","volume":"9","author":"Corrales","year":"2021","journal-title":"Front Bioeng Biotechnol"},{"key":"R177-20260304","doi-asserted-by":"crossref","first-page":"061013","DOI":"10.1115\/1.4050030","article-title":"Load-sharing and kinematics of the human cervical spine under multi-axial transverse shear loading: combined experimental and computational investigation","volume":"143","author":"Whyte","year":"2021","journal-title":"J Biomech Eng"},{"key":"R178-20260304","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1007\/s10439-023-03396-7","article-title":"Quantifying the importance of active muscle repositioning a finite element neck model in flexion using kinematic, kinetic, and tissue-level responses","volume":"52","author":"Hadagali","year":"2024","journal-title":"Ann Biomed Eng"},{"key":"R179-20260304","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1007\/s10439-022-03089-7","article-title":"Spinal cord boundary conditions affect brain tissue strains in impact simulations","volume":"51","author":"Rycman","year":"2023","journal-title":"Ann Biomed Eng"},{"key":"R180-20260304","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1177\/0954411916644634","article-title":"Motion analysis study on sensitivity of finite element model of the cervical spine to geometry","volume":"230","author":"Zafarparandeh","year":"2016","journal-title":"Proc Inst Mech Eng H"},{"key":"R181-20260304","doi-asserted-by":"crossref","first-page":"16","DOI":"10.3390\/bioengineering9010016","article-title":"Investigation into cervical spine biomechanics following single, multilevel and hybrid disc replacement surgery with dynamic cervical implant and fusion: a finite element study","volume":"9","author":"Mumtaz","year":"2022","journal-title":"Bioengineering"},{"issue":"suppl 1","key":"R182-20260304","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1080\/10255842.2014.931140","article-title":"A framework towards personalisation and active muscle integration in a 3D finite-element neck model for orthopaedic applications","volume":"17","author":"Howley","year":"2014","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R183-20260304","doi-asserted-by":"crossref","first-page":"4578","DOI":"10.1007\/s11434-014-0452-x","article-title":"A dynamic finite element model of human cervical spine with in vivo kinematic validation","volume":"59","author":"Wang","year":"2014","journal-title":"Chin Sci Bull"},{"key":"R184-20260304","doi-asserted-by":"crossref","first-page":"e2048","DOI":"10.1097\/MD.0000000000002048","article-title":"Hybrid strategy of two-level cervical artificial disc and intervertebral cage: biomechanical effects on tissues and implants","volume":"94","author":"Chung","year":"2015","journal-title":"Medicine (Baltimore)"},{"key":"R185-20260304","doi-asserted-by":"crossref","first-page":"2854","DOI":"10.1016\/j.jbiomech.2016.06.027","article-title":"Resection or degeneration of uncovertebral joints altered the segmental kinematics and load-sharing pattern of subaxial cervical spine: A biomechanical investigation using a C2-T1 finite element model","volume":"49","author":"Wang","year":"2016","journal-title":"J Biomech"},{"key":"R186-20260304","doi-asserted-by":"crossref","first-page":"E580","DOI":"10.1097\/BRS.0b013e31817ecc57","article-title":"The effect of cerebrospinal fluid on the biomechanics of spinal cord: an ex vivo bovine model using bovine and physical surrogate spinal cord","volume":"33","author":"Jones","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R187-20260304","doi-asserted-by":"crossref","first-page":"315","DOI":"10.3171\/2009.1.SPINE08286","article-title":"The effect of bone fragment size and cerebrospinal fluid on spinal cord deformation during trauma: an ex vivo study","volume":"10","author":"Persson","year":"2009","journal-title":"J Neurosurg Spine"},{"key":"R188-20260304","doi-asserted-by":"crossref","first-page":"081003","DOI":"10.1115\/1.4033794","article-title":"Biomechanical behaviors in three types of spinal cord injury mechanisms","volume":"138","author":"Khuyagbaatar","year":"2016","journal-title":"J Biomech Eng"},{"key":"R189-20260304","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.jbiomech.2017.03.019","article-title":"Biomechanical investigation of post-operative C5 palsy due to ossification of the posterior longitudinal ligament in different types of cervical spinal alignment","volume":"57","author":"Khuyagbaatar","year":"2017","journal-title":"J Biomech"},{"key":"R190-20260304","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1177\/0954411917718222","article-title":"Increased stress and strain on the spinal cord due to ossification of the posterior longitudinal ligament in the cervical spine under flexion after laminectomy","volume":"231","author":"Khuyagbaatar","year":"2017","journal-title":"Proc Inst Mech Eng H"},{"key":"R191-20260304","doi-asserted-by":"crossref","first-page":"071006","DOI":"10.1115\/1.4039826","article-title":"Biomechanical effects on cervical spinal cord and nerve root following laminoplasty for ossification of the posterior longitudinal ligament in the cervical spine: a comparison between open-door and double-door laminoplasty using finite element analysis","volume":"140","author":"Khuyagbaatar","year":"2018","journal-title":"J Biomech Eng"},{"key":"R192-20260304","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.clinbiomech.2017.10.017","article-title":"Biomechanics of anterior plating failure in treating distractive flexion injury in the caudal subaxial cervical spine","volume":"50","author":"Wang","year":"2017","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R193-20260304","doi-asserted-by":"crossref","first-page":"6023","DOI":"10.1038\/s41598-021-85257-8","article-title":"Biomechanical influence of the surgical approaches, implant length and density in stabilizing ankylosing spondylitis cervical spine fracture","volume":"11","author":"Liu","year":"2021","journal-title":"Sci Rep"},{"key":"R194-20260304","doi-asserted-by":"crossref","first-page":"2308","DOI":"10.1007\/s00586-017-5193-5","article-title":"A finite element study of traditional Chinese cervical manipulation","volume":"26","author":"Deng","year":"2017","journal-title":"Eur Spine J"},{"key":"R195-20260304","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.msksp.2017.01.005","article-title":"Cervical traction therapy with and without neck support: a finite element analysis","volume":"28","author":"Wang","year":"2017","journal-title":"Musculoskelet Sci Pract"},{"key":"R196-20260304","doi-asserted-by":"crossref","first-page":"1926","DOI":"10.1016\/j.spinee.2017.07.009","article-title":"The biomechanical impact of facet tropism on the intervertebral disc and facet joints in the cervical spine","volume":"17","author":"Rong","year":"2017","journal-title":"Spine J"},{"key":"R197-20260304","doi-asserted-by":"crossref","first-page":"10","DOI":"10.3171\/2017.5.SPINE17189","article-title":"Intubation biomechanics: validation of a finite element model of cervical spine motion during endotracheal intubation in intact and injured conditions","volume":"28","author":"Gadomski","year":"2018","journal-title":"J Neurosurg Spine"},{"issue":"suppl 2","key":"R198-20260304","doi-asserted-by":"crossref","first-page":"S116","DOI":"10.1080\/15389588.2019.1670818","article-title":"Comparison of control strategies for the cervical muscles of an average female head-neck finite element model","volume":"20","author":"Putra","year":"2019","journal-title":"Traffic Inj Prev"},{"key":"R199-20260304","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.jbiomech.2016.11.066","article-title":"A female head-neck model for rear impact simulations","volume":"51","author":"\u00d6sth","year":"2017","journal-title":"J Biomech"},{"key":"R200-20260304","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.jbiomech.2007.07.007","article-title":"Head and neck anthropometry, vertebral geometry and neck strength in height-matched men and women","volume":"41","author":"Vasavada","year":"2008","journal-title":"J Biomech"},{"key":"R201-20260304","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1002\/ar.1091220409","article-title":"Dimensions of the cervical vertebrae","volume":"122","author":"Francis","year":"1955","journal-title":"Anat Rec"},{"key":"R202-20260304","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jmbbm.2014.09.023","article-title":"A method to characterize average cervical spine ligament response based on raw data sets for implementation into injury biomechanics models","volume":"41","author":"Mattucci","year":"2015","journal-title":"J Mech Behav Biomed Mater"},{"key":"R203-20260304","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.jmbbm.2012.02.004","article-title":"Strain rate dependent properties of younger human cervical spine ligaments","volume":"10","author":"Mattucci","year":"2012","journal-title":"J Mech Behav Biomed Mater"},{"key":"R204-20260304","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1097\/00007632-198805000-00016","article-title":"Tensile strength of spinal ligaments","volume":"13","author":"Myklebust","year":"1988","journal-title":"Spine (Phila Pa 1976)"},{"key":"R205-20260304","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1080\/15389588.2016.1227072","article-title":"Effects of whole spine alignment patterns on neck responses in rear end impact","volume":"18","author":"Sato","year":"2017","journal-title":"Traffic Inj Prev"},{"key":"R206-20260304","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/S0021-9290(03)00159-3","article-title":"Gender dependent cervical spine segmental kinematics during whiplash","volume":"36","author":"Stemper","year":"2003","journal-title":"J Biomech"},{"key":"R207-20260304","doi-asserted-by":"crossref","first-page":"1764","DOI":"10.1097\/01.BRS.0000134563.10718.A7","article-title":"Gender- and region-dependent local facet joint kinematics in rear impact: implications in whiplash injury","volume":"29","author":"Stemper","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R208-20260304","first-page":"149","article-title":"Response corridors of the human head-neck complex in rear impact","volume":"48","author":"Stemper","year":"2004","journal-title":"Annu Proc Assoc Adv Automot Med"},{"key":"R209-20260304","first-page":"121+","article-title":"Motion in the cervical spine. An experimental study on autopsy specimens","volume":"(Suppl 1)23","author":"Lysell","year":"1969","journal-title":"Acta Orthop Scand"},{"key":"R210-20260304","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.wneu.2015.09.025","article-title":"Subaxial cervical intradiscal pressure and segmental kinematics following atlantoaxial fixation in different angles","volume":"87","author":"Liu","year":"2016","journal-title":"World Neurosurg"},{"key":"R211-20260304","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1007\/s10237-022-01616-y","article-title":"Analysis of control strategies for VIVA OpenHBM with active reflexive neck muscles","volume":"21","author":"Putra","year":"2022","journal-title":"Biomech Model Mechanobiol"},{"key":"R212-20260304","doi-asserted-by":"crossref","first-page":"968939","DOI":"10.3389\/fbioe.2022.968939","article-title":"Finite element human body models with active reflexive muscles suitable for sex based whiplash injury prediction","volume":"10","author":"Putra","year":"2022","journal-title":"Front Bioeng Biotechnol"},{"key":"R213-20260304","doi-asserted-by":"crossref","first-page":"e3651","DOI":"10.1002\/cnm.3651","article-title":"Experimental and numerical analysis of biomechanical effects in cervical spine positioning rotation manipulation","volume":"38","author":"Chang","year":"2022","journal-title":"Int J Numeric Methods Biomed Eng"},{"key":"R214-20260304","first-page":"1989","article-title":"Biomechanical analysis of brachial plexus injury: availability of three-dimensional finite element model of the brachial plexus","volume":"15","author":"Mihara","year":"2018","journal-title":"Exp Ther Med"},{"key":"R215-20260304","doi-asserted-by":"crossref","first-page":"4542750","DOI":"10.1155\/2018\/4542750","article-title":"Investigation of the effect of neck muscle active force on whiplash injury of the cervical spine","volume":"2018","author":"Yan","year":"2018","journal-title":"Appl Bionics Biomech"},{"key":"R216-20260304","doi-asserted-by":"crossref","first-page":"111008","DOI":"10.1115\/1.4043666","article-title":"Rear-impact neck whiplash: role of head inertial properties and spine morphological variations on segmental rotations","volume":"141","author":"John","year":"2019","journal-title":"J Biomech Eng"},{"key":"R217-20260304","doi-asserted-by":"crossref","first-page":"18850","DOI":"10.1038\/s41598-019-54785-9","article-title":"Biomechanical investigation of extragraft bone formation influences on the operated motion segment after anterior cervical spinal discectomy and fusion","volume":"9","author":"Park","year":"2019","journal-title":"Sci Rep"},{"key":"R218-20260304","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1186\/s13018-019-1502-5","article-title":"The appropriate hybrid surgical strategy in three-level cervical degenerative disc disease: a finite element analysis","volume":"14","author":"Xie","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R219-20260304","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.hcl.2004.09.004","article-title":"Adult brachial plexus injuries: mechanism, patterns of injury, and physical diagnosis","volume":"21","author":"Moran","year":"2005","journal-title":"Hand Clin"},{"key":"R220-20260304","doi-asserted-by":"crossref","first-page":"S24","DOI":"10.1016\/0303-8467(93)90030-K","article-title":"Mechanisms of brachial plexus lesions","volume":"95 (Suppl)","author":"Coene","year":"1993","journal-title":"Clin Neurol Neurosurg"},{"key":"R221-20260304","article-title":"Relationship between localized spine deformation and cervical vertebral motions for low speed rear impacts using human volunteers","author":"Ono","year":"1999","journal-title":"SAE Tech Pap"},{"key":"R222-20260304","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1097\/00007632-198603000-00010","article-title":"A study of vertebra and disc geometric relations of the human cervical and lumbar spine","volume":"11","author":"Gilad","year":"1986","journal-title":"Spine (Phila Pa 1976)"},{"key":"R223-20260304","doi-asserted-by":"crossref","first-page":"E44","DOI":"10.1097\/BRS.0b013e318160462a","article-title":"Anatomical gender differences in cervical vertebrae of size-matched volunteers","volume":"33","author":"Stemper","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"R224-20260304","doi-asserted-by":"crossref","first-page":"1520","DOI":"10.1007\/s00586-009-1085-7","article-title":"Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty","volume":"18","author":"Finn","year":"2009","journal-title":"Eur Spine J"},{"issue":"suppl 1","key":"R225-20260304","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1093\/milmed\/usaa338","article-title":"Neck vertebral level-specific forces and moments under G-x accelerative loading","volume":"186","author":"Purushothaman","year":"2021","journal-title":"Mil Med"},{"key":"R226-20260304","doi-asserted-by":"crossref","first-page":"269","DOI":"10.4103\/jcvjs.JCVJS_158_20","article-title":"Effects of different severities of disc degeneration on the range of motion of cervical spine","volume":"11","author":"Yoganandan","year":"2020","journal-title":"J Craniovertebr Junction Spine"},{"key":"R227-20260304","doi-asserted-by":"crossref","first-page":"2631","DOI":"10.1007\/s00586-019-06113-y","article-title":"Unique biomechanical signatures of Bryan, Prodisc C, and Prestige LP cervical disc replacements: a finite element modelling study","volume":"29","author":"Choi","year":"2020","journal-title":"Eur Spine J"},{"issue":"Suppl 1","key":"R228-20260304","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1093\/milmed\/usaa378","article-title":"Comparative finite element modeling study of anterior cervical arthrodesis versus cervical arthroplasty with bryan disc or prodisc C","volume":"186","author":"Choi","year":"2021","journal-title":"Mil Med"},{"key":"R229-20260304","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s00701-020-04619-9","article-title":"Influence of cervical spine sagittal alignment on range of motion after corpectomy: a finite element study","volume":"163","author":"John","year":"2021","journal-title":"Acta Neurochir"},{"key":"R230-20260304","doi-asserted-by":"crossref","first-page":"103735","DOI":"10.1016\/j.jmbbm.2020.103735","article-title":"External and internal responses of cervical disc arthroplasty and anterior cervical discectomy and fusion: a finite element modeling study","volume":"106","author":"Purushothaman","year":"2020","journal-title":"J Mech Behav Biomed Mater"},{"key":"R231-20260304","doi-asserted-by":"crossref","first-page":"103857","DOI":"10.1016\/j.medengphy.2022.103857","article-title":"Normalization technique to build patient specific muscle model in finite element head neck spine","volume":"107","author":"Varghese","year":"2022","journal-title":"Med Eng Phys"},{"key":"R232-20260304","doi-asserted-by":"crossref","first-page":"105352","DOI":"10.1016\/j.cmpb.2020.105352","article-title":"Biomechanical evaluation of adjacent segment degeneration after one- or two-level anterior cervical discectomy and fusion versus cervical disc arthroplasty: a finite element analysis","volume":"189","author":"Hua","year":"2020","journal-title":"Comput Methods Programs Biomed"},{"key":"R233-20260304","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1186\/s12893-020-00729-4","article-title":"Adjacent-level biomechanics after single-level anterior cervical interbody fusion with anchored zero-profile spacer versus cage-plate construct: a finite element study","volume":"20","author":"Li","year":"2020","journal-title":"BMC Surg"},{"key":"R234-20260304","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1080\/10255842.2020.1764545","article-title":"Fatigue damage prediction in the annulus of cervical spine intervertebral discs using finite element analysis","volume":"23","author":"Subramani","year":"2020","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"R235-20260304","doi-asserted-by":"crossref","first-page":"103760","DOI":"10.1016\/j.compbiomed.2020.103760","article-title":"Adjacent segment biomechanical changes after one- or two-level anterior cervical discectomy and fusion using either a zero-profile device or cage plus plate: a finite element analysis","volume":"120","author":"Hua","year":"2020","journal-title":"Comput Biol Med"},{"key":"R236-20260304","doi-asserted-by":"crossref","first-page":"121004","DOI":"10.1115\/1.4028107","article-title":"High rotation rate behavior of cervical spine segments in flexion and extension","volume":"136","author":"Barker","year":"2014","journal-title":"J Biomech Eng"},{"key":"R237-20260304","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1097\/00006123-199902000-00078","article-title":"Intradiscal pressure recordings in the cervical spine","volume":"44","author":"Pospiech","year":"1999","journal-title":"Neurosurgery"},{"key":"R239-20260304","doi-asserted-by":"crossref","first-page":"2668","DOI":"10.1016\/j.jbiomech.2012.08.012","article-title":"The effects of ligamentous injury in the human lower cervical spine","volume":"45","author":"Leahy","year":"2012","journal-title":"J Biomech"},{"key":"R241-20260304","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.clinbiomech.2017.03.007","article-title":"Cervical facet force analysis after disc replacement versus fusion","volume":"44","author":"Patel","year":"2017","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R242-20260304","first-page":"3109","article-title":"Biomechanical analysis of cervical range of motion and facet contact force after a novel artificial cervical disc replacement","volume":"11","author":"Zhao","year":"2019","journal-title":"Am J Transl Res"},{"key":"R243-20260304","doi-asserted-by":"crossref","first-page":"E778","DOI":"10.1097\/BRS.0b013e31824780b8","article-title":"Adjacent-level range of motion and intradiscal pressure after posterior cervical decompression and fixation: an in vitro human cadaveric model","volume":"37","author":"Kretzer","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"R244-20260304","doi-asserted-by":"crossref","first-page":"2431","DOI":"10.1097\/00007632-200211150-00003","article-title":"Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion","volume":"27","author":"Eck","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R245-20260304","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/BF01631392","article-title":"Anatomic bases for anterior spinal surgery: surgical anatomy of the cervical vertebral body and disc space","volume":"21","author":"Lu","year":"1999","journal-title":"Surg Radiol Anat"},{"key":"R246-20260304","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/00007632-200201010-00011","article-title":"A method to simulate in vivo cervical spine kinematics using in vitro compressive preload","volume":"27","author":"Miura","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"issue":"Database issue","key":"R247-20260304","doi-asserted-by":"crossref","first-page":"D782","DOI":"10.1093\/nar\/gkn613","article-title":"BodyParts3D: 3D structure database for anatomical concepts","volume":"37","author":"Mitsuhashi","year":"2009","journal-title":"Nucleic Acids Res"},{"key":"R248-20260304","doi-asserted-by":"crossref","first-page":"325","DOI":"10.4067\/S0717-95022011000200003","article-title":"Morphometric study of cervical vertebrae C3-C7 in a population from Northeastern Mexico","volume":"29","author":"Bazald\u00faa Cruz","year":"2011","journal-title":"Int J Morphol"},{"key":"R249-20260304","doi-asserted-by":"crossref","first-page":"105174","DOI":"10.1016\/j.clinbiomech.2020.105174","article-title":"Biomechanical comparison of spinal cord compression types occurring in degenerative cervical myelopathy","volume":"81","author":"L\u00e9vy","year":"2021","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R250-20260304","doi-asserted-by":"crossref","first-page":"106355","DOI":"10.1016\/j.cmpb.2021.106355","article-title":"Impact of adjacent pre-existing disc degeneration status on its biomechanics after single-level anterior cervical interbody fusion","volume":"209","author":"Li","year":"2021","journal-title":"Comput Methods Programs Biomed"},{"key":"R251-20260304","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1186\/s13018-020-1549-3","article-title":"Biomechanical comparison of noncontiguous cervical disc arthroplasty and noncontiguous cervical discectomy and fusion in the treatment of noncontinuous cervical degenerative disc disease: a finite element analysis","volume":"15","author":"Sun","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"R252-20260304","doi-asserted-by":"crossref","first-page":"011004","DOI":"10.1115\/1.4047866","article-title":"Multilevel validation of a male neck finite element model with active musculature","volume":"143","author":"Barker","year":"2021","journal-title":"J Biomech Eng"},{"key":"R253-20260304","doi-asserted-by":"crossref","first-page":"e0250270","DOI":"10.1371\/journal.pone.0250270","article-title":"Comparison of biomechanical performance of single-level triangular and quadrilateral profile anterior cervical plates","volume":"16","author":"Cao","year":"2021","journal-title":"PLoS One"},{"key":"R254-20260304","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1177\/09544119211018112","article-title":"Development of a finite element neck model for head-first compressive impacts: toward the assessment of motorcycle neck protective equipment","volume":"235","author":"Nasim","year":"2021","journal-title":"Proc Inst Mech Eng H"},{"key":"R255-20260304","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1186\/s12891-019-2425-3","article-title":"Biomechanics following skip-level cervical disc arthroplasty versus skip-level cervical discectomy and fusion: a finite element-based study","volume":"20","author":"Wu","year":"2019","journal-title":"BMC Musculoskelet Disord"},{"key":"R256-20260304","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.1097\/BRS.0b013e3181fc1aff","article-title":"Disc replacement adjacent to cervical fusion: a biomechanical comparison of hybrid construct versus two-level fusion","volume":"36","author":"Lee","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"R257-20260304","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1097\/00024720-200310000-00002","article-title":"Internal stress distribution in cervical intervertebral discs: the influence of an artificial cervical joint and simulated anterior interbody fusion","volume":"16","author":"Wigfield","year":"2003","journal-title":"J Spinal Disord Tech"},{"key":"R258-20260304","doi-asserted-by":"crossref","first-page":"1701","DOI":"10.1007\/s00586-007-0458-z","article-title":"The internal mechanical properties of cervical intervertebral discs as revealed by stress profilometry","volume":"16","author":"Skrzypiec","year":"2007","journal-title":"Eur Spine J"},{"key":"R259-20260304","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/1687814015602597","article-title":"Effect of a novel compressible artificial disk on biomechanical performance of cervical spine: a finite element study","volume":"7","author":"Chen","year":"2015","journal-title":"Adv Mech Eng"},{"key":"R260-20260304","first-page":"171","article-title":"Kinematics of human cadaver cervical spine during low speed rear-end impacts","volume":"44","author":"Deng","year":"2000","journal-title":"Stapp Car Crash J"},{"key":"R261-20260304","doi-asserted-by":"crossref","DOI":"10.4271\/861895","article-title":"Simulation of head-neck dynamic response in \u2212Gx and +Gy","author":"Bosio","year":"1986","journal-title":"SAE Tech Pap"},{"key":"R262-20260304","first-page":"1360","article-title":"Performance criteria for a mechanical head\/neck that predicts secondary impact force levels during frontal flexion","volume":"96","author":"Spenny","year":"1987","journal-title":"SAE Trans"},{"key":"R263-20260304","first-page":"459","article-title":"Performance requirements for mechanical necks in lateral flexion","volume":"92","author":"Wismans","year":"1983","journal-title":"SAE Trans"},{"key":"R264-20260304","doi-asserted-by":"crossref","first-page":"412","DOI":"10.2106\/00004623-199603000-00013","article-title":"Experimental impact injury to the cervical spine: relating motion of the head and the mechanism of injury","volume":"78","author":"Nightingale","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"R265-20260304","first-page":"3968","article-title":"The dynamic responses of the cervical spine: buckling, end conditions, and tolerance in compressive impacts","volume":"106","author":"Nightingale","year":"1997","journal-title":"SAE Trans"},{"key":"R266-20260304","doi-asserted-by":"crossref","first-page":"151856","DOI":"10.1016\/j.aanat.2021.151856","article-title":"Biomechanical analysis of the cervical spine segment as a method for studying the functional and dynamic anatomy of the human neck","volume":"240","author":"Ovsepyan","year":"2021","journal-title":"Ann Anat"},{"key":"R267-20260304","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1186\/s12891-021-04244-2","article-title":"A lattice topology optimization of cervical interbody fusion cage and finite element comparison with ZK60 and Ti-6Al-4V cages","volume":"22","author":"Sun","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"key":"R268-20260304","doi-asserted-by":"crossref","first-page":"680769","DOI":"10.3389\/fbioe.2021.680769","article-title":"Biomechanical analysis of cervical artificial disc replacement using cervical subtotal discectomy prosthesis","volume":"9","author":"Wo","year":"2021","journal-title":"Front Bioeng Biotechnol"},{"key":"R269-20260304","doi-asserted-by":"crossref","first-page":"8825150","DOI":"10.1155\/2021\/8825150","article-title":"Effect of a traction exercise neck brace on cervical spondylopathy radiculopathy: a clinical study and finite element analysis","volume":"2021","author":"Xiao","year":"2021","journal-title":"Evid Based Complement Alternat Med"},{"key":"R270-20260304","doi-asserted-by":"crossref","first-page":"106987","DOI":"10.1016\/j.clineuro.2021.106987","article-title":"Biomechanical evaluation of the craniovertebral junction after odontoidectomy with anterior C1 arch preservation: a finite element study","volume":"211","author":"Xie","year":"2021","journal-title":"Clin Neurol Neurosurg"},{"key":"R271-20260304","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/0021-9290(91)90354-P","article-title":"Variations of stiffness and strength along the human cervical spine","volume":"24","author":"Shea","year":"1991","journal-title":"J Biomech"},{"key":"R272-20260304","doi-asserted-by":"crossref","first-page":"317","DOI":"10.2214\/ajr.130.2.317","article-title":"Normal movements of the cervical spine","volume":"130","author":"Penning","year":"1978","journal-title":"Am J Roentgenol"},{"key":"R273-20260304","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1097\/00007632-198710000-00003","article-title":"Rotation of the cervical spine. A CT study in normal subjects","volume":"12","author":"Penning","year":"1987","journal-title":"Spine (Phila Pa 1976)"},{"key":"R274-20260304","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1097\/00007632-198911000-00001","article-title":"Three-dimensional motion analysis of the cervical spine with special reference to the axial rotation","volume":"14","author":"Mimura","year":"1989","journal-title":"Spine (Phila Pa 1976)"},{"key":"R275-20260304","doi-asserted-by":"crossref","first-page":"2505","DOI":"10.1097\/00007632-199411001-00003","article-title":"The range and nature of flexion-extension motion in the cervical spine","volume":"19","author":"Holmes","year":"1994","journal-title":"Spine (Phila Pa 1976)"},{"key":"R276-20260304","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/00007632-199402000-00004","article-title":"Three-dimensional motion of the upper cervical spine in rheumatoid arthritis","volume":"19","author":"Iai","year":"1994","journal-title":"Spine (Phila Pa 1976)"},{"key":"R277-20260304","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1002\/jor.1100150305","article-title":"Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: quantification using a finite element model of the C5-C6 segment","volume":"15","author":"Clausen","year":"1997","journal-title":"J Orthop Res"},{"key":"R278-20260304","first-page":"692","article-title":"Normal range of motion of the cervical spine","volume":"70","author":"Lind","year":"1989","journal-title":"Arch Phys Med Rehabil"},{"key":"R279-20260304","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1097\/01.brs.0000195173.47334.1f","article-title":"Kinematics of the cervical spine in lateral bending: in vivo three-dimensional analysis","volume":"31","author":"Ishii","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R280-20260304","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1097\/00007632-200405010-00006","article-title":"Soft tissue injury threshold during simulated whiplash: a biomechanical investigation","volume":"29","author":"Ito","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R281-20260304","doi-asserted-by":"crossref","first-page":"2255","DOI":"10.1007\/s11517-023-02817-y","article-title":"Effect of muscle activation on dynamic responses of neck of pilot during emergency ejection: a finite element study","volume":"61","author":"Li","year":"2023","journal-title":"Med Biol Eng Comput"},{"key":"R282-20260304","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1016\/j.spinee.2017.02.007","article-title":"Cervical lordosis: the effect of age and gender","volume":"17","author":"Been","year":"2017","journal-title":"Spine J"},{"key":"R283-20260304","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.1007\/s00586-012-2167-5","article-title":"Age-related changes in osseous anatomy, alignment, and range of motion of the cervical spine. Part I: radiographic data from over 1,200 asymptomatic subjects","volume":"21","author":"Yukawa","year":"2012","journal-title":"Eur Spine J"},{"key":"R284-20260304","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1097\/00002517-199109000-00004","article-title":"Quantitative anatomy of cervical spine ligaments. Part II. Middle and lower cervical spine","volume":"4","author":"Panjabi","year":"1991","journal-title":"J Spinal Disord"},{"key":"R285-20260304","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.jbiomech.2018.05.031","article-title":"Influence of follower load application on moment-rotation parameters and intradiscal pressure in the cervical spine","volume":"76","author":"Bell","year":"2018","journal-title":"J Biomech"},{"key":"R286-20260304","doi-asserted-by":"crossref","first-page":"e0232975","DOI":"10.1371\/journal.pone.0232975","article-title":"Effect of experimental, morphological and mechanical factors on the murine spinal cord subjected to transverse contusion: a finite element study","volume":"15","author":"Fournely","year":"2020","journal-title":"PLoS One"},{"key":"R287-20260304","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jneumeth.2017.09.007","article-title":"High-speed video analysis improves the accuracy of spinal cord compression measurement in a mouse contusion model","volume":"293","author":"Fournely","year":"2018","journal-title":"J Neurosci Methods"},{"key":"R288-20260304","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.jmbbm.2013.04.005","article-title":"Strain rate dependent properties of human craniovertebral ligaments","volume":"23","author":"Mattucci","year":"2013","journal-title":"J Mech Behav Biomed Mater"},{"key":"R289-20260304","first-page":"0148","article-title":"Investigation of upper body and cervical spine kinematics of post mortem human subjects (PMHS) during low-speed, rear-end impacts","author":"White","year":"2009","journal-title":"SAE Tech Pap"},{"key":"R290-20260304","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1097\/00007632-198910000-00013","article-title":"Dynamic response of human cervical spine ligaments","volume":"14","author":"Yoganandan","year":"1989","journal-title":"Spine"},{"key":"R291-20260304","doi-asserted-by":"crossref","first-page":"e358","DOI":"10.1016\/j.wneu.2022.04.112","article-title":"Soft tissue injury in cervical spine is a risk factor for intersegmental instability: a finite element analysis","volume":"164","author":"Nishida","year":"2022","journal-title":"World Neurosurg"},{"key":"R292-20260304","doi-asserted-by":"crossref","first-page":"107479","DOI":"10.1016\/j.cmpb.2023.107479","article-title":"Quantitatively biomechanical response analysis of posterior musculature reconstruction in cervical single-door laminoplasty","volume":"233","author":"Liang","year":"2023","journal-title":"Comput Methods Programs Biomed"},{"key":"R293-20260304","first-page":"135","article-title":"Improved estimation of human neck tensile tolerance: reducing the range of reported tolerance using anthropometrically correct muscles and optimized physiologic initial conditions","volume":"47","author":"Chancey","year":"2003","journal-title":"Stapp Car Crash J"},{"key":"R294-20260304","first-page":"110","article-title":"Multibody modeling of the cervical spine in the simulation of flexion-extension after disc arthroplasty","volume":"4","author":"Galbusera","year":"2006","journal-title":"J Appl Biomater Biomech"},{"key":"R295-20260304","doi-asserted-by":"crossref","first-page":"E330","DOI":"10.1097\/01.brs.0000263331.78903.61","article-title":"Biomechanical testing simulation of a cadaver spine specimen: development and evaluation study","volume":"32","author":"Ahn","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R296-20260304","first-page":"175","article-title":"Development of a multi-body computational model of human head and neck","volume":"221","author":"van Lopik","year":"2007","journal-title":"Proc Inst Mech Eng Part K: J Multi-body Dynam"},{"key":"R297-20260304","first-page":"397","article-title":"Variation of neck muscle strength along the human cervical spine","volume":"48","author":"Oi","year":"2004","journal-title":"Stapp Car Crash J"},{"key":"R298-20260304","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/S0268-0033(02)00067-0","article-title":"Neck muscle strength across the sagittal and coronal planes: an isometric study","volume":"17","author":"Seng","year":"2002","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R299-20260304","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1002\/pri.210","article-title":"Intra- and inter-tester reliability and reference values for isometric neck strength","volume":"6","author":"Peolsson","year":"2001","journal-title":"Physiother Res Int"},{"key":"R300-20260304","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1097\/00007632-199907010-00012","article-title":"Maximal isometric strength of the cervical musculature in 100 healthy volunteers","volume":"24","author":"Jordan","year":"1999","journal-title":"Spine (Phila Pa 1976)"},{"key":"R301-20260304","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1002\/jor.1100090415","article-title":"Effects of alar ligament transection on upper cervical spine rotation","volume":"9","author":"Panjabi","year":"1991","journal-title":"J Orthop Res"},{"key":"R302-20260304","article-title":"Human head and neck response to impact acceleration","author":"Ewing","year":"1972","journal-title":"Naval Aerospace and Regional Medical Centre"},{"key":"R303-20260304","first-page":"287","article-title":"Segmentary antero-posterior mobility of the cervical spine","volume":"44","author":"Aho","year":"1955","journal-title":"Ann Med Intern Fenn"},{"key":"R304-20260304","first-page":"181","article-title":"Normal ranges of intervertebral-joint motion of the cervical spine","volume":"12","author":"Bhalla","year":"1969","journal-title":"Can J Surg"},{"key":"R305-20260304","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1097\/00007632-198807000-00007","article-title":"Functional radiographic diagnosis of the cervical spine: flexion\/extension","volume":"13","author":"Dvorak","year":"1988","journal-title":"Spine (Phila Pa 1976)"},{"key":"R306-20260304","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/0268-0033(93)90014-9","article-title":"Composite motion in cervical disc segments","volume":"8","author":"Milne","year":"1993","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R308-20260304","doi-asserted-by":"crossref","first-page":"111001","DOI":"10.1115\/1.4031351","article-title":"A cervico-thoraco-lumbar multibody dynamic model for the estimation of joint loads and muscle forces","volume":"137","author":"Khurelbaatar","year":"2015","journal-title":"J Biomech Eng"},{"key":"R309-20260304","doi-asserted-by":"crossref","first-page":"e0169329","DOI":"10.1371\/journal.pone.0169329","article-title":"Cervical spine injuries: a whole-body musculoskeletal model for the analysis of spinal loading","volume":"12","author":"Cazzola","year":"2017","journal-title":"PLoS One"},{"key":"R310-20260304","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/S1350-4533(00)00002-3","article-title":"Finite element modeling of the cervical spine: role of intervertebral disc under axial and eccentric loads","volume":"21","author":"Kumaresan","year":"1999","journal-title":"Med Eng Phys"},{"key":"R311-20260304","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1016\/j.medengphy.2005.09.006","article-title":"Finite element modeling of multi-level cervical spinal segments (C3-C6) and biomechanical analysis of an elastomer-type prosthetic disc","volume":"28","author":"Ha","year":"2006","journal-title":"Med Eng Phys"},{"issue":"suppl 5","key":"R312-20260304","doi-asserted-by":"crossref","first-page":"S653","DOI":"10.1007\/s00586-009-1211-6","article-title":"Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation","volume":"21","author":"Faizan","year":"2012","journal-title":"Eur Spine J"},{"key":"R313-20260304","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00221-012-3388-x","article-title":"Dependency of human neck reflex responses on the bandwidth of pseudorandom anterior-posterior torso perturbations","volume":"226","author":"Forbes","year":"2013","journal-title":"Exp Brain Res"},{"key":"R314-20260304","doi-asserted-by":"crossref","first-page":"378","DOI":"10.2106\/JBJS.G.01483","article-title":"Motion of the shoulder complex during multiplanar humeral elevation","volume":"91","author":"Ludewig","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"R315-20260304","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1016\/j.clinbiomech.2010.01.015","article-title":"Comparison of scapular local coordinate systems","volume":"25","author":"Ludewig","year":"2010","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"Suppl 10","key":"R316-20260304","doi-asserted-by":"crossref","first-page":"S393","DOI":"10.1097\/00007632-199210001-00009","article-title":"Age and gender related normal motion of the cervical spine","volume":"17","author":"Dvorak","year":"1992","journal-title":"Spine (Phila Pa 1976)"},{"key":"R317-20260304","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1097\/00007632-198710000-00002","article-title":"CT-functional diagnostics of the rotatory instability of the upper cervical spine. Part 2. An evaluation on healthy adults and patients with suspected instability","volume":"12","author":"Dvorak","year":"1987","journal-title":"Spine (Phila Pa 1976)"},{"key":"R318-20260304","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/00007632-199301000-00018","article-title":"Clinical validation of functional flexion\/extension radiographs of the cervical spine","volume":"18","author":"Dvor\u00e1k","year":"1993","journal-title":"Spine (Phila Pa 1976)"},{"key":"R319-20260304","doi-asserted-by":"crossref","first-page":"E1403","DOI":"10.1097\/BRS.0000000000002176","article-title":"Prediction of cervical spinal joint loading and secondary motion using a musculoskeletal multibody dynamics model via force-dependent kinematics approach","volume":"42","author":"Diao","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"key":"R320-20260304","doi-asserted-by":"crossref","first-page":"e0199912","DOI":"10.1371\/journal.pone.0199912","article-title":"The inclusion of hyoid muscles improve moment generating capacity and dynamic simulations in musculoskeletal models of the head and neck","volume":"13","author":"Mortensen","year":"2018","journal-title":"PLoS One"},{"key":"R321-20260304","doi-asserted-by":"crossref","first-page":"751291","DOI":"10.3389\/fbioe.2022.751291","article-title":"Sensitivity of the Cervical disc loads, translations, intradiscal pressure, and muscle activity due to segmental mass, disc stiffness, and muscle strength in an upright neutral posture","volume":"10","author":"Arshad","year":"2022","journal-title":"Front Bioeng Biotechnol"},{"key":"R322-20260304","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/S0021-9290(00)00191-3","article-title":"Muscle recruitment by the min\/max criterion - a comparative numerical study","volume":"34","author":"Rasmussen","year":"2001","journal-title":"J Biomech"},{"key":"R323-20260304","doi-asserted-by":"crossref","first-page":"E594","DOI":"10.1097\/BRS.0b013e31828ca5c7","article-title":"Motion path of the instant center of rotation in the cervical spine during in vivo dynamic flexion-extension: implications for artificial disc design and evaluation of motion quality after arthrodesis","volume":"38","author":"Anderst","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"key":"R324-20260304","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1097\/00007632-199802150-00002","article-title":"Influence of muscle morphometry and moment arms on the moment-generating capacity of human neck muscles","volume":"23","author":"Vasavada","year":"1998","journal-title":"Spine (Phila Pa 1976)"},{"key":"R326-20260304","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1016\/j.medengphy.2013.03.007","article-title":"Is it possible to estimate the compressive force in the lumbar spine from intradiscal pressure measurements? A finite element evaluation","volume":"35","author":"Dreischarf","year":"2013","journal-title":"Med Eng Phys"},{"key":"R327-20260304","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/00003086-198001000-00019","article-title":"Intradiskal pressure and volume recording: evaluation of normal and abnormal cervical disks","volume":"146","author":"Kambin","year":"1980","journal-title":"Clin Orthop Relat Res"},{"key":"R328-20260304","first-page":"568","article-title":"Cervical intradiscal pressure in movements and traction of the cervical spine","volume":"119","author":"Hattori","year":"1981","journal-title":"Z Orthop"},{"key":"R329-20260304","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1080\/00140139.2019.1677944","article-title":"Cervical spine joint loading with neck flexion","volume":"63","author":"Barrett","year":"2020","journal-title":"Ergonomics"},{"issue":"suppl 1","key":"R330-20260304","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1080\/10255840512331388001","article-title":"Cervical muscles forces and spinal loads estimation in standing position: asymptomatic cases","volume":"8","author":"Assi","year":"2005","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R332-20260304","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.clinbiomech.2017.12.001","article-title":"A subject-specific biomechanical control model for the prediction of cervical spine muscle forces","volume":"51","author":"Van den Abbeele","year":"2018","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R335-20260304","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1186\/s40001-021-00521-x","article-title":"The future of basic science in orthopaedics and traumatology: Cassandra or Prometheus?","volume":"26","author":"Madry","year":"2021","journal-title":"Eur J Med Res"},{"key":"R336-20260304","doi-asserted-by":"crossref","first-page":"2356","DOI":"10.1007\/s10439-019-02314-0","article-title":"In vivo measurement of plantar tissue characteristics and its indication for foot modeling","volume":"47","author":"Mo","year":"2019","journal-title":"Ann Biomed Eng"},{"key":"R337-20260304","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ijmecsci.2022.107108","article-title":"A three-dimensional finite element foot-ankle model and its personalisation methods analysis","volume":"219","author":"Mo","year":"2022","journal-title":"Int J Mech Sci"},{"key":"R338-20260304","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1016\/j.jbiomech.2014.04.002","article-title":"Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together","volume":"47","author":"Dreischarf","year":"2014","journal-title":"J Biomech"},{"key":"R339-20260304","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.compbiomed.2019.04.010","article-title":"Development and validation of a geometrically personalized finite element model of the lower ligamentous cervical spine for clinical applications(C3-7)","volume":"109","author":"Nikkhoo","year":"2019","journal-title":"Comput Biol Med"},{"key":"R340-20260304","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1038\/s41467-022-28387-5","article-title":"Deep learning-based high-accuracy quantitation for lumbar intervertebral disc degeneration from MRI","volume":"13","author":"Zheng","year":"2022","journal-title":"Nat Commun"},{"key":"R341-20260304","doi-asserted-by":"crossref","first-page":"25","DOI":"10.5312\/wjo.v3.i4.25","article-title":"Applications of finite element simulation in orthopedic and trauma surgery","volume":"3","author":"Herrera","year":"2012","journal-title":"World J Orthop"},{"key":"R342-20260304","doi-asserted-by":"crossref","first-page":"33","DOI":"10.14245\/ns.1836084.042","article-title":"Ossification of the posterior longitudinal ligament in cervical spine: prevalence, management, and prognosis","volume":"15","author":"Wu","year":"2018","journal-title":"Neurospine"},{"key":"R343-20260304","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.jbspin.2007.07.019","article-title":"Prevalence of ossification of the posterior longitudinal ligament of the cervical spine","volume":"75","author":"Kim","year":"2008","journal-title":"Joint Bone Spine"},{"key":"R344-20260304","doi-asserted-by":"crossref","first-page":"1822","DOI":"10.1016\/j.spinee.2021.06.010","article-title":"Kinematics after cervical laminoplasty: risk factors for cervical kyphotic deformity after laminoplasty","volume":"21","author":"Kim","year":"2021","journal-title":"Spine J"},{"key":"R345-20260304","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1080\/15389588.2014.931949","article-title":"A human body model with active muscles for simulation of pretensioned restraints in autonomous braking interventions","volume":"16","author":"Osth","year":"2015","journal-title":"Traffic Inj Prev"},{"issue":"suppl 1","key":"R346-20260304","doi-asserted-by":"crossref","first-page":"S36","DOI":"10.1080\/15389588.2015.1015000","article-title":"Development and validation of the total HUman model for safety (THUMS) toward further understanding of occupant injury mechanisms in precrash and during crash","volume":"16","author":"Iwamoto","year":"2015","journal-title":"Traffic Inj Prev"},{"key":"R349-20260304","doi-asserted-by":"crossref","first-page":"124","DOI":"10.20485\/jsaeijae.9.3_124","article-title":"Finite element analysis for investigating the effects of muscle activation on head-neck injury risks of drivers rear-ended by a car after an autonomous emergency braking","volume":"9","author":"Iwamoto","year":"2018","journal-title":"Int J Automot Eng"},{"key":"R350-20260304","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1080\/10255842.2016.1170123","article-title":"Implementation of reflex loops in a biomechanical finite element model","volume":"19","author":"Salin","year":"2016","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R351-20260304","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.jbiomech.2019.05.001","article-title":"Implementation of controlling strategy in a biomechanical lower limb model with active muscles for coupling multibody dynamics and finite element analysis","volume":"91","author":"Mo","year":"2019","journal-title":"J Biomech"},{"key":"R352-20260304","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1093\/icb\/icaa027","article-title":"\u201cSimple\u201d biomechanical model for ants reveals how correlated evolution among body segments minimizes variation in center of mass as heads get larger","volume":"60","author":"Anderson","year":"2020","journal-title":"Integr Comp Biol"},{"issue":"2S","key":"R353-20260304","doi-asserted-by":"crossref","first-page":"e099","DOI":"10.1097\/OI9.0000000000000099","article-title":"Biomechanical models: key considerations in study design","volume":"4","author":"Augat","year":"2021","journal-title":"OTA International"},{"key":"R355-20260304","doi-asserted-by":"crossref","first-page":"1925","DOI":"10.1080\/02699052.2017.1385853","article-title":"The effects of tackle height on inertial loading of the head and neck in Rugby Union: A multibody model analysis","volume":"31","author":"Tierney","year":"2017","journal-title":"Brain Inj"},{"key":"R356-20260304","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1007\/s10439-019-02359-1","article-title":"Validation of a football helmet finite element model and quantification of impact energy distribution","volume":"48","author":"Corrales","year":"2020","journal-title":"Ann Biomed Eng"},{"key":"R357-20260304","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/s40870-019-00189-9","article-title":"Component-level finite element model and validation for a modern American Football Helmet","volume":"5","author":"Bustamante","year":"2019","journal-title":"J Dynamic Behav Mater"},{"key":"R358-20260304","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1136\/bjsports-2011-090360","article-title":"Mechanisms of cervical spine injury in rugby union: a systematic review of the literature","volume":"46","author":"Kuster","year":"2012","journal-title":"Br J Sports Med"},{"key":"R359-20260304","doi-asserted-by":"crossref","first-page":"2914","DOI":"10.1007\/s10439-021-02855-3","article-title":"Head kinematics and injury metrics for laboratory hockey-relevant head impact experiments","volume":"49","author":"Levy","year":"2021","journal-title":"Ann Biomed Eng"},{"key":"R360-20260304","doi-asserted-by":"crossref","first-page":"121007","DOI":"10.1115\/1.4040605","article-title":"Distribution of brain strain in the cerebrum for laboratory impacts to ice hockey goaltender masks","volume":"140","author":"Michio Clark","year":"2018","journal-title":"J Biomech Eng"},{"key":"R361-20260304","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s12283-020-00325-y","article-title":"Protective capacity of ice hockey helmets at different levels of striking compliance","volume":"23","author":"de Grau","year":"2020","journal-title":"Sports Eng"},{"key":"R362-20260304","first-page":"125","article-title":"A comparative numerical study to compute ocular injury in boxing","volume":"234","author":"Razaghi","year":"2020","journal-title":"Proc Inst Mech Eng P J Sport Eng Technol"},{"key":"R363-20260304","doi-asserted-by":"crossref","first-page":"459","DOI":"10.21037\/atm-21-134","article-title":"Numerical simulation and analysis of midfacial impacts and traumatic brain injuries","volume":"9","author":"Li","year":"2021","journal-title":"Ann Transl Med"},{"key":"R364-20260304","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.clinbiomech.2019.05.003","article-title":"Head dynamic response and brain tissue deformation for boxing punches with and without loss of consciousness","volume":"67","author":"Cournoyer","year":"2019","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R365-20260304","doi-asserted-by":"crossref","first-page":"160","DOI":"10.21037\/tp.2017.04.08","article-title":"Epidemiology of sports-related musculoskeletal injuries in young athletes in United States","volume":"6","author":"Patel","year":"2017","journal-title":"Transl Pediatr"},{"key":"R366-20260304","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/s40621-018-0175-6","article-title":"The burden of hospitalized sports-related injuries in children: an Australian population-based study, 2005\u20132013","volume":"5","author":"Schneuer","year":"2018","journal-title":"Injury Epidemiology"},{"key":"R367-20260304","doi-asserted-by":"crossref","first-page":"595619","DOI":"10.3389\/fspor.2020.595619","article-title":"An interdisciplinary examination of stress and injury occurrence in athletes","volume":"2","author":"Fisher","year":"2020","journal-title":"Front Sports Act Living"},{"key":"R368-20260304","doi-asserted-by":"crossref","first-page":"4857","DOI":"10.3390\/ijerph18094857","article-title":"Epidemiology of sports-related injuries and associated risk factors in adolescent athletes: an injury surveillance","volume":"18","author":"Prieto-Gonz\u00e1lez","year":"2021","journal-title":"Int J Environ Res Public Health"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000001941","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T12:04:51Z","timestamp":1772625891000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000001941"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,11]]},"references-count":341,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000001941","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,11]]},"assertion":[{"value":"2024-05-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-06-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}