{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T19:54:14Z","timestamp":1794081254306,"version":"4.8.0"},"reference-count":81,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","license":[{"start":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T00:00:00Z","timestamp":1728259200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-sa\/4.0\/ http:\/\/creativecommons.org\/licenses\/by-sa\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>One of the most important surgical steps during thyroidectomy is the safe ligation of vessels. In fact, it is crucial to avoid postoperative bleeding and nerves\u2019 injury. The \u201cclamp and tie\u201d technique was first introduced in the 19<jats:sup>th<\/jats:sup> century. Since then, a lot of other techniques have been adopted to facilitate the safe ligation and sectioning of thyroidal vessels; however, one of the most relevant advances is the introduction of energy-based devices (EBDs), which occurred three decades ago.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>The aim of this systematic review and meta-analysis is to evaluate the safety and effectiveness of sutureless FOCUS harmonic scalpel (second-generation EBDs) versus conventional clamps-and-tie technique) in total thyroidectomy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>This systematic review and meta-analysis represent the largest comparison in the literature between the thyroidectomy procedure with the second-generation advanced harmonic scalpel ultrasonic focus (UAS FOCUS) versus the conventional clamp-and-tie (CT) technique: as a matter of fact, it includes 43 randomized controlled trials (RCTs) and a total of 10\u00a0361 patients. The incidence of transient recurrent laryngeal nerve palsy was statistically lower in patients undergoing UAS (3.99%) rather than CT (5.23%) (RR 0.79, 95% CI 0.63\u20130.99). The incidence of transient hypocalcemia was 11.3% in patients who underwent thyroidectomy with UAS FOCUS and 15.4% in those who underwent thyroidectomy with CT.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Sutureless EBD is associated with a lower risk of damage to the laryngeal nerves and parathyroid glands. The rate of hypocalcemia and nerve paresis is indeed lower due to less thermic damage. Sutureless EBD can also diminish the rate of postoperative bleeding and cervical hematoma, a rare but potentially fatal complication.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/js9.0000000000002113","type":"journal-article","created":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T12:02:10Z","timestamp":1728302530000},"page":"8083-8096","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":13,"title":["Sutureless FOCUS harmonic scalpel versus clamp-and-tie techniques for thyroidectomy: a meta-analysis of 43 randomized controlled trials"],"prefix":"10.1097","volume":"110","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2457-0636","authenticated-orcid":false,"given":"Roberto","family":"Cirocchi","sequence":"first","affiliation":[{"name":"Department of General Surgery, University of Perugia, Terni"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8724-2859","authenticated-orcid":false,"given":"Matteo","family":"Matteucci","sequence":"additional","affiliation":[{"name":"Department of General Surgery, University of Milan, Milan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1943-4952","authenticated-orcid":false,"given":"Eleonora","family":"Lori","sequence":"additional","affiliation":[{"name":"Department of Surgery, Sapienza University of Rome, Rome"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5709-2530","authenticated-orcid":false,"given":"Vito","family":"D\u2019Andrea","sequence":"additional","affiliation":[{"name":"Department of Surgery, Sapienza University of Rome, Rome"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Arezzo","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, University of Torino, Turin, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1545-0779","authenticated-orcid":false,"given":"Daniele","family":"Pironi","sequence":"additional","affiliation":[{"name":"Department of Surgery, Sapienza University of Rome, Rome"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5818-6405","authenticated-orcid":false,"given":"Stefano","family":"Avenia","sequence":"additional","affiliation":[{"name":"Department of General Surgery, University of Perugia, Terni"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6733-5380","authenticated-orcid":false,"given":"Justus","family":"Randolph","sequence":"additional","affiliation":[{"name":"Georgia Baptist College of Nursing, Mercer University, Atlanta, GA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-9446-4693","authenticated-orcid":false,"given":"Ileana","family":"Tiraboschi","sequence":"additional","affiliation":[{"name":"Division of General and Hepatobiliary Surgery, Department of Surgical Science, Dentistry, Gynecology and Pediatrics, University of Verona, Verona"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7152-4096","authenticated-orcid":false,"given":"Giovanni Domenico","family":"Tebala","sequence":"additional","affiliation":[{"name":"Department of Digestive and Emergency, Hospital of Terni, Terni, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georgi I.","family":"Popivanov","sequence":"additional","affiliation":[{"name":"Department of Surgery, Medical Military Academy of Sofia, Sofia, Bulgaria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0427-6648","authenticated-orcid":false,"given":"Salvatore","family":"Sorrenti","sequence":"additional","affiliation":[{"name":"Department of Surgery, Sapienza University of Rome, Rome"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,12]]},"reference":[{"key":"R1-20250824","doi-asserted-by":"crossref","first-page":"2446","DOI":"10.1002\/lary.21076","article-title":"The increasing incidence of small thyroid cancers: where are the cases coming from?","volume":"120","author":"Davies","year":"2010","journal-title":"Laryngoscope"},{"key":"R2-20250824","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1001\/jamaoto.2017.1746","article-title":"Nationwide variation in rates of thyroidectomy among US medicare beneficiaries","volume":"143","author":"Francis","year":"2017","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R3-20250824","doi-asserted-by":"crossref","first-page":"1793","DOI":"10.1007\/s00268-010-0580-7","article-title":"Historical evolution of thyroid surgery: from the ancient times to the dawn of the 21st century","volume":"34","author":"Sakorafas","year":"2010","journal-title":"World J Surg"},{"key":"R4-20250824","first-page":"510","article-title":"Kocher\u2019s gland dissector, thyroid retractor and artery forceps","volume":"16","author":"Ellis","year":"2006","journal-title":"J Perioper Pract"},{"key":"R5-20250824","first-page":"268","article-title":"Total thyroidectomy for non-toxic multinodular goiter with versus without the use of harmonic FOCUS dissecting shears\u2014a prospective randomized study","volume":"7","author":"Konturek","year":"2012","journal-title":"Wideochir Inne Tech Maloinwazyjne"},{"key":"R6-20250824","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1016\/j.otohns.2009.06.745","article-title":"Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy","volume":"141","author":"Pons","year":"2009","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R7-20250824","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1002\/hed.24449","article-title":"Comparison between Focus Harmonic scalpel and other hemostatic techniques in open thyroidectomy: a systematic review and meta-analysis","volume":"38","author":"Cannizzaro","year":"2016","journal-title":"Head Neck"},{"key":"R8-20250824","doi-asserted-by":"crossref","first-page":"399","DOI":"10.2147\/CEOR.S164747","article-title":"Procedure costs associated with the use of Harmonic devices compared to conventional techniques in various surgeries: a systematic review and meta-analysis","volume":"10","author":"Cheng","year":"2018","journal-title":"Clinicoecon Outcomes Res"},{"key":"R9-20250824","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1186\/1477-7819-8-112","article-title":"Meta-analysis of thyroidectomy with ultrasonic dissector versus conventional clamp and tie","volume":"8","author":"Cirocchi","year":"2010","journal-title":"World J Surg Oncol"},{"key":"R10-20250824","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1007\/s00423-013-1137-7","article-title":"ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery--the ENERCON systematic review and network meta-analysis","volume":"398","author":"Contin","year":"2013","journal-title":"Langenbecks Arch Surg"},{"key":"R11-20250824","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.otohns.2010.03.018","article-title":"Hemostasis in thyroid surgery: harmonic scalpel versus other techniques\u2014a meta-analysis","volume":"143","author":"Ecker","year":"2010","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R12-20250824","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1089\/thy.2012.0588","article-title":"Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies","volume":"23","author":"Garas","year":"2013","journal-title":"Thyroid"},{"key":"R13-20250824","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1007\/s00405-016-4190-3","article-title":"A comparison of surgical outcomes and complications between hemostatic devices for thyroid surgery: a network meta-analysis","volume":"274","author":"Luo","year":"2017","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R14-20250824","first-page":"396079","article-title":"Harmonic scalpel compared to conventional hemostasis in thyroid surgery: a meta-analysis of randomized clinical trials","volume":"2010","author":"Melck","year":"2010","journal-title":"Int J Surg Oncol"},{"key":"R15-20250824","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1001\/archsurg.2009.201","article-title":"Prospective clinical trials of thyroidectomy with LigaSure vs conventional vessel ligation: a systematic review and meta-analysis","volume":"144","author":"Yao","year":"2009","journal-title":"Arch Surg"},{"key":"R16-20250824","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1177\/1553350610362084","article-title":"Ultrasonic coagulator for thyroidectomy: a systematic review of randomized controlled trials","volume":"17","author":"Zhang","year":"2010","journal-title":"Surg Innov"},{"key":"R17-20250824","doi-asserted-by":"crossref","first-page":"e6141","DOI":"10.1097\/MD.0000000000006141","article-title":"A meta-analysis comparing the outcomes of LigaSure Small Jaw versus clamp-and-tie technique or Harmonic Focus Scalpel in thyroidectomy","volume":"96","author":"Zhang","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"R18-20250824","doi-asserted-by":"crossref","first-page":"105906","DOI":"10.1016\/j.ijsu.2021.105906","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"88","author":"Page","year":"2021","journal-title":"Int J Surg"},{"key":"R19-20250824","doi-asserted-by":"crossref","first-page":"j4008","DOI":"10.1136\/bmj.j4008","article-title":"AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both","volume":"358","author":"Shea","year":"2017","journal-title":"BMJ"},{"key":"R20-20250824","doi-asserted-by":"crossref","first-page":"g1687","DOI":"10.1136\/bmj.g1687","article-title":"Better reporting of interventions: template for intervention description and replication (TIDieR) checklist and guide","volume":"348","author":"Hoffmann","year":"2014","journal-title":"BMJ"},{"key":"R21-20250824","doi-asserted-by":"crossref","first-page":"j2998","DOI":"10.1136\/bmj.j2998","article-title":"Enhancing the usability of systematic reviews by improving the consideration and description of interventions","volume":"358","author":"Hoffmann","year":"2017","journal-title":"BMJ"},{"key":"R23-20250824","author":"Deeks"},{"key":"R24-20250824","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1002\/sim.1186","article-title":"Quantifying heterogeneity in a meta-analysis","volume":"21","author":"Higgins","year":"2022","journal-title":"Stat Med"},{"key":"R25-20250824","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses","volume":"327","author":"Higgins","year":"2003","journal-title":"BMJ"},{"key":"R26-20250824","doi-asserted-by":"crossref","first-page":"569","DOI":"10.37723\/jumdc.v14i1.802","article-title":"Comparison of Harmonic scalpel and conventional homeostasis in understanding complications followed by total thyroidectomy","volume":"14","author":"Memon","year":"2023","journal-title":"J Univ Med Dent College"},{"key":"R27-20250824","doi-asserted-by":"crossref","first-page":"175","DOI":"10.21608\/aumj.2022.165485.1024","article-title":"Safety and feasibility of sutureless total thyroidectomy","volume":"2","author":"Basha","year":"2022","journal-title":"Aswan Univ Med J"},{"key":"R28-20250824","doi-asserted-by":"crossref","first-page":"559","DOI":"10.18203\/2349-2902.isj20210363","article-title":"Harmonic scalpel thyroidectomy versus conventional haemostasis thyroidectomy","volume":"8","author":"Haq","year":"2021","journal-title":"Int Surg J"},{"key":"R29-20250824","doi-asserted-by":"crossref","first-page":"511","DOI":"10.21608\/amj.2021.147966","article-title":"Harmonic scalpel versus conventional technique in total thyroidectomy (comparative study)","volume":"50","author":"Soliman Mohamed","year":"2021","journal-title":"Al-Azhar Med J"},{"key":"R30-20250824","doi-asserted-by":"crossref","first-page":"1","DOI":"10.21608\/ejentas.2021.56244.1300","article-title":"Total thyroidectomy: conventional suture ligation technique versus sutureless techniques, Sohag experince","volume":"22","author":"Amer","year":"2021","journal-title":"Egyptian J Ear Nose Throat Allied Sci"},{"key":"R31-20250824","doi-asserted-by":"crossref","first-page":"954","DOI":"10.18203\/2349-2902.isj20201372","article-title":"A comparative study between harmonic scalpel hemostasis and conventional hemostasis in total thyroidectomy","volume":"7","author":"El Sherpiny","year":"2020","journal-title":"Int Surg J"},{"key":"R32-20250824","doi-asserted-by":"crossref","first-page":"98","DOI":"10.4103\/AZMJ.AZMJ_131_19","article-title":"A comparative study between sutureless total thyroidectomy by harmonic scalpel and traditional method (clamp and tie)","volume":"18","author":"Elghany","year":"2020","journal-title":"Al-Azhar Assiut Med J"},{"key":"R33-20250824","first-page":"107","article-title":"Comparison between conventional and harmonic techniques in bleeding control during thyroidectomy","volume":"6","author":"Saim","year":"2020","journal-title":"World JPharma Med Res"},{"key":"R34-20250824","first-page":"7","article-title":"Role of harmonic scalpel versus conventional haemostasis among patients undergoing total thyroidectomy","volume":"31","author":"Buzdar","year":"2020","journal-title":"Med Forum"},{"key":"R35-20250824","doi-asserted-by":"crossref","first-page":"186","DOI":"10.18203\/issn.2454-5929.ijohns20195712","article-title":"Merits of harmonic scalpel over conventional hemostasis in open thyroid surgery: a randomised controlled trial","volume":"6","author":"Bajaj","year":"2020","journal-title":"Int J Otorhinolaryngol Head Neck Surg"},{"key":"R36-20250824","doi-asserted-by":"crossref","first-page":"68","DOI":"10.29309\/TPMJ\/2019.27.01.3278","article-title":"Comparison of Harmonic Scalpel versus conventional hemostasis in Thyroid surgery in terms of per-operative and postoperative outcome","volume":"27","author":"Ali","year":"2020","journal-title":"Professional Med J"},{"key":"R37-20250824","doi-asserted-by":"crossref","first-page":"300","DOI":"10.4103\/MJBL.MJBL_45_18","article-title":"Sutureless focus harmonic thyroidectomy versus conventional clamping and knot\u2011tying technique","volume":"15","author":"Noori","year":"2018","journal-title":"Med J Babylon"},{"key":"R38-20250824","first-page":"553","article-title":"Comparison of surgical outcomes and complications between the Harmonic FOCUS and conventional surgery for open thyroidectomy","volume":"8","author":"Maeda","year":"2018","journal-title":"Mol Clin Oncol"},{"key":"R39-20250824","first-page":"296","article-title":"Comparison of outcome after thyroid surgery using harmonic versus conventional clamp and tie method","volume":"10","author":"Ahmed","year":"2018","journal-title":"Isra Med J"},{"key":"R40-20250824","doi-asserted-by":"crossref","first-page":"1431","DOI":"10.18203\/2349-2902.isj20171156","article-title":"Prospective randomised study using focus harmonic scalpel versus conventional hemostasis for vessel ligation in open thyroid surgery","volume":"4","author":"Anandaravi","year":"2017","journal-title":"Int Surg J"},{"key":"R41-20250824","doi-asserted-by":"crossref","first-page":"132","DOI":"10.16956\/jes.2018.18.2.132","article-title":"Post-operative Hypocalcaemia following open thyroidectomy for benign multinodular goiters using FOCUS harmonic scalpel versus conventional suture ligation technique for hemostasis: a prospective, single-blind, randomized controlled trial","volume":"18","author":"Zehra","year":"2018","journal-title":"J Endocr Surg"},{"key":"R42-20250824","doi-asserted-by":"crossref","first-page":"241","DOI":"10.32007\/jfacmedbagdad.583257","article-title":"Comparative study between Harmonic FOCUS\u2122 to clamp and tie technique for total thyroidectomy","volume":"58","author":"Saloom","year":"2016","journal-title":"J Fac Med Baghdad [Internet]"},{"key":"R43-20250824","first-page":"256","article-title":"Therapeutic effects of bipolar coagulation forceps on open thyroid surgery","volume":"68","author":"Su","year":"2016","journal-title":"Rev Invest Clin"},{"key":"R44-20250824","first-page":"175","article-title":"Comparative study between Focus harmonic scalpel and conventional hemostasis in open total thyroidectomy","volume":"31","author":"Gaber","year":"2018","journal-title":"Menoufia Med J"},{"key":"R45-20250824","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.asjsur.2016.12.004","article-title":"Is the superior laryngeal nerve really safe when using harmonic focus in total thyroidectomy? A prospective randomized study","volume":"41","author":"Arslan","year":"2018","journal-title":"Asian J Surg"},{"key":"R46-20250824","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1002\/bjs5.2","article-title":"Randomized clinical trial of ultrasonic scissors versus conventional haemostasis to compare complications and economics after total thyroidectomy (FOThyr)","volume":"1","author":"Blanchard","year":"2017","journal-title":"BJS Open"},{"key":"R47-20250824","doi-asserted-by":"crossref","first-page":"62","DOI":"10.4103\/1110-1121.199893","article-title":"Sutureless thyroidectomy for controlled toxic goiter: a single-institute experience","volume":"36","author":"Shaaban","year":"2017","journal-title":"Egyptian J Surg"},{"key":"R48-20250824","first-page":"141","article-title":"Safety and cost-effectiveness in thyroidectomy using the HARMONIC scalpel compared to traditional hemostasis: a controlled clinical assay","volume":"30","author":"Basurto-Kuba","year":"2017","journal-title":"Surg Technol Int"},{"key":"R49-20250824","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.amsu.2015.11.010","article-title":"Total thyroidectomy: conventional suture ligation technique versus sutureless techniques using harmonic scalpel or maxium","volume":"5","author":"Al-Dhahiry","year":"2015","journal-title":"Ann Med Surg (Lond)"},{"key":"R50-20250824","first-page":"3544","article-title":"Study on the use of focus harmonic scalpel in thyroidectomies: is it useful also in preserving voice function?","volume":"20","author":"Minni","year":"2016","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"R51-20250824","first-page":"48","article-title":"Suture-less thyroidectomy using harmonic scalpel versus conventional thyroidectomy: a randomized controlled trial","volume":"6","author":"Aziz","year":"2016","journal-title":"J Pioneer Med Sci"},{"key":"R53-20250824","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1186\/2193-1801-3-639","article-title":"The use of FOCUS Harmonic scalpel compared to conventional haemostasis (knot and tie ligation) for thyroid surgery: a prospective randomized study","volume":"3","author":"Cannizzaro","year":"2014","journal-title":"Springerplus"},{"key":"R54-20250824","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1007\/s12262-012-0627-0","article-title":"Harmonic scalpel compared to conventional hemostasis in thyroid surgery","volume":"76","author":"Yener","year":"2014","journal-title":"Indian J Surg"},{"key":"R55-20250824","first-page":"19266","article-title":"The comparison of the harmonic focus shears device with conventional clamp binding in total thyroidectomy","volume":"8","author":"\u00c7ift\u00e7i","year":"2015","journal-title":"Int J Clin Exp Med"},{"issue":"Suppl 1","key":"R56-20250824","doi-asserted-by":"crossref","first-page":"S132","DOI":"10.1016\/j.ijsu.2014.05.028","article-title":"The safety of the Harmonic\u00ae FOCUS in open thyroidectomy: a prospective, randomized study comparing the Harmonic\u00ae FOCUS and traditional suture ligation (knot and tie) technique","volume":"12","author":"Zangh\u00ec","year":"2014","journal-title":"Int J Surg"},{"key":"R57-20250824","first-page":"10","article-title":"Technique of clamp-tie thyroidectomy versus Harmonic focus\u00ae. Is there a need for technology?","volume":"41","author":"Bangash","year":"2014","journal-title":"J Sci Soc"},{"key":"R58-20250824","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1186\/1916-0216-42-62","article-title":"FOCUS harmonic scalpel compared to conventional hemostasis in open total thyroidectomy - a prospective randomized study","volume":"42","author":"Duan","year":"2013","journal-title":"J Otolaryngol Head Neck Surg"},{"key":"R59-20250824","article-title":"Harmonic scalpel is more secure than conventional methods in total thyroidectomy: a randomized clinical trial","volume":"2","author":"Soroush","year":"2013","journal-title":"J Minim Invasive Surg Sci"},{"key":"R60-20250824","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1089\/lap.2011.0266","article-title":"New ultrasonic dissector versus conventional hemostasis in thyroid surgery: a randomized prospective study","volume":"22","author":"Sista","year":"2012","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"R61-20250824","doi-asserted-by":"crossref","first-page":"357195","DOI":"10.1155\/2011\/357195","article-title":"Focus harmonic scalpel compared to conventional haemostasis in open total thyroidectomy: a prospective randomized trial","volume":"2011","author":"Ferri","year":"2011","journal-title":"Int J Otolaryngol"},{"key":"R62-20250824","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1007\/s13304-013-0223-2","article-title":"The impact of the Harmonic FOCUS\u2122 on complications in thyroid surgery: a prospective multicenter study","volume":"65","author":"Materazzi","year":"2013","journal-title":"Updates Surg"},{"key":"R63-20250824","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s13304-011-0099-y","article-title":"Harmonic Focus\u2122 versus \u201cknot tying\u201d during total thyroidectomy: a randomized trial","volume":"63","author":"Gentileschi","year":"2011","journal-title":"Updates Surg"},{"key":"R64-20250824","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1186\/1477-7819-9-141","article-title":"Harmonic focus in total thyroidectomy plus level III-IV and VI dissection: a prospective randomized study","volume":"9","author":"He","year":"2011","journal-title":"World J Surg Oncol"},{"key":"R65-20250824","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.amjsurg.2010.07.047","article-title":"Randomized clinical trial on Harmonic Focus shears versus clamp-and-tie technique for total thyroidectomy","volume":"202","author":"Mourad","year":"2011","journal-title":"Am J Surg"},{"key":"R66-20250824","doi-asserted-by":"crossref","first-page":"48","DOI":"10.21608\/ejsur.2011.367367","article-title":"The use of harmonic scalpel versus knot tying for total-thyroidectomy. A prospective randomized study","volume":"30","author":"Askar","year":"2011","journal-title":"Egypt J Surg"},{"key":"R67-20250824","first-page":"296","article-title":"Studio comparativo tra tecnica tradizionale, Ligasure Precise ed Harmonic Focus nella tiroidectomia totale [Comparison of conventional technique, ligasure precise and harmonic focus in total thyroidectomy]","volume":"31","author":"Di Rienzo","year":"2010","journal-title":"G Chir"},{"key":"R68-20250824","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s12262-013-0856-x","article-title":"Salient anatomical landmarks of thyroid and their practical significance in thyroid surgery: a pictorial review of thyroid surgical anatomy (revisited)","volume":"76","author":"Bhargav","year":"2014","journal-title":"Indian J Surg"},{"key":"R69-20250824","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1007\/s00276-013-1149-6","article-title":"Emerging patterns of the human superior thyroid artery and review of its clinical anatomy","volume":"36","author":"Anagnostopoulou","year":"2014","journal-title":"Surg Radiol Anat"},{"key":"R70-20250824","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.aanat.2005.04.004","article-title":"A meta-analysis of inferior thyroid artery variations in different human ethnic groups and their clinical implications","volume":"187","author":"Toni","year":"2005","journal-title":"Ann Anat"},{"key":"R71-20250824","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1308\/rcsann.2016.0270","article-title":"Patterns, timing and consequences of post-thyroidectomy haemorrhage","volume":"99","author":"Farooq","year":"2017","journal-title":"Ann R Coll Surg Engl"},{"key":"R72-20250824","doi-asserted-by":"crossref","first-page":"72","DOI":"10.3342\/ceo.2009.2.2.72","article-title":"Patterns of post-thyroidectomy hemorrhage","volume":"2","author":"Lee","year":"2009","journal-title":"Clin Exp Otorhinolaryngol"},{"key":"R73-20250824","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.surg.2013.06.032","article-title":"A multi-institutional international study of risk factors for hematoma after thyroidectomy","volume":"154","author":"Campbell","year":"2013","journal-title":"Surgery"},{"key":"R74-20250824","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1002\/hed.1076","article-title":"Re-operation for bleeding after thyroidectomy and parathyroidectomy","volume":"23","author":"Abbas","year":"2001","journal-title":"Head Neck"},{"key":"R75-20250824","doi-asserted-by":"crossref","first-page":"1156","DOI":"10.1007\/s00268-019-05322-2","article-title":"Reoperation for bleeding after thyroid and parathyroid surgery: incidence, risk factors, prevention, and management","volume":"44","author":"Edafe","year":"2020","journal-title":"World J Surg"},{"key":"R76-20250824","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.jviscsurg.2013.04.003","article-title":"Complications after total thyroidectomy","volume":"150","author":"Christou","year":"2013","journal-title":"J Visc Surg"},{"key":"R77-20250824","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1111\/j.1742-1241.2008.01875.x","article-title":"Diagnosis of recurrent laryngeal nerve palsy after thyroidectomy: a systematic review","volume":"63","author":"Jeannon","year":"2009","journal-title":"Int J Clin Pract"},{"key":"R78-20250824","doi-asserted-by":"crossref","first-page":"490","DOI":"10.21037\/gs.2016.09.01","article-title":"Safety of energy based devices for hemostasis in thyroid surgery","volume":"5","author":"Dionigi","year":"2016","journal-title":"Gland Surg"},{"key":"R79-20250824","doi-asserted-by":"crossref","first-page":"750","DOI":"10.3111\/13696998.2016.1168826","article-title":"Hospital costs associated with thyroidectomy performed with a Harmonic device compared to conventional techniques: a systematic review and meta-analysis","volume":"19","author":"Cheng","year":"2016","journal-title":"J Med Econ"},{"key":"R80-20250824","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1186\/s13044-015-0027-1","article-title":"A systematic review and meta-analysis of Harmonic Focus in thyroidectomy compared to conventional techniques","volume":"8","author":"Cheng","year":"2015","journal-title":"Thyroid Res"},{"key":"R81-20250824","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1590\/1806-9282.64.07.649","article-title":"Effectiveness of harmonic scalpel in patients submitted to total thyroidectomy: systematic review with meta-analysis","volume":"64","author":"Aires","year":"2018","journal-title":"Rev Assoc Med Bras (1992)"},{"issue":"Suppl 1","key":"R82-20250824","doi-asserted-by":"crossref","first-page":"S22","DOI":"10.1016\/j.ijsu.2015.12.050","article-title":"Complications in thyroid surgery. Harmonic scalpel, harmonic focus versus conventional hemostasis: a meta-analysis","volume":"28","author":"Revelli","year":"2016","journal-title":"Int J Surg"},{"key":"R83-20250824","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.amjsurg.2007.01.037","article-title":"Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation","volume":"195","author":"Manouras","year":"2008","journal-title":"Am J Surg"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000002113","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,24]],"date-time":"2025-08-24T19:17:27Z","timestamp":1756063047000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000002113"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,7]]},"references-count":81,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000002113","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,7]]},"assertion":[{"value":"2024-05-17","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}