{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T11:12:54Z","timestamp":1791976374796,"version":"4.4.0"},"reference-count":42,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T00:00:00Z","timestamp":1753228800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>End-stage heart failure remains a major global health challenge with high mortality. While heart transplantation is the gold-standard treatment, the scarcity of donor hearts necessitates alternative therapies. Left ventricular assist devices effectively support patients with end-stage left heart failure, but no mature biventricular assist devices (BiVADs) currently exist for those with biventricular failure. To address this gap, we developed the DuoCor BiVAD, a novel, integrated, magnetically levitated miniaturized biventricular assist system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This study reports the results of animal experiments and short-term clinical outcomes focusing on the DuoCor BiVAD. Animal experiments were conducted on three healthy adult male Chinese Merino sheep, with the endpoint being 2\u00a0months after device implantation, followed by retrieval and evaluation. Clinical data were collected from eight patients who underwent DuoCor BiVAD implantation at Wuhan Union Hospital between July 2024 and December 2024, with a median follow-up period of 6\u00a0months. During this period, device parameters, changes in patient heart function, and the occurrence of device-related adverse events (such as infection, thrombosis, and bleeding) were monitored.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>All animal implants achieved technical success (4.0\u00a0\u00b1\u00a00.7\u00a0h procedure time) with sustained 60-day hemodynamic stability and absence of device malfunction, thrombosis, or infection. In the clinical study, the median operative time was 5.1\u00a0hours, and the median postoperative hospital stay was 35\u00a0days. There were no in-hospital mortalities or device-related infections, and all patients were discharged home with DuoCor BiVAD support. During the 6-month postoperative follow-up period, one 81-year-old patient succumbed to frailty and COVID-19 infection 2 weeks post-discharge. The remaining seven patients survived with ongoing DuoCor BiVAD support, with no incidents of hemolysis, bleeding, device-related infection, or chronic renal insufficiency. This cohort includes one patient who developed right ventricular assist device thrombosis at 2\u00a0months post-implantation. Evaluation confirmed recovery of right ventricular function after the acute postoperative phase, prompting the discontinuation of right pump support. This patient subsequently maintained hemodynamic stability with left ventricular assist device support and experienced no further adverse events throughout follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>As a feasibility validation study of the first artificial BiVAD, DuoCor BiVAD demonstrated acceptable safety profiles during the short-term observation period. Although preliminary clinical outcomes were promising, these findings warrant cautious interpretation due to study size limitations and restricted follow-up duration. Furthermore, the device\u2019s integrated lightweight design and differential ventricular support technology confer advantages over existing solutions. Further validation through prospective multicenter cohort studies remains essential to establish long-term safety and efficacy profiles.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000002879","type":"journal-article","created":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T17:00:14Z","timestamp":1753376414000},"page":"6743-6754","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Implantation of integrated magnetically levitated biventricular assist devices (DuoCor) \u2013 a single-center clinical experience"],"prefix":"10.1097","volume":"111","author":[{"given":"Shijie","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yixuan","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shunzhou","family":"Yu","sequence":"additional","affiliation":[{"name":"Shenzhen Core Medical Technology Co., Ltd., Shenzhen, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fanwu","family":"Kong","sequence":"additional","affiliation":[{"name":"Shenzhen Core Medical Technology Co., Ltd., Shenzhen, Guangdong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nianguo","family":"Dong","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,23]]},"reference":[{"key":"R1-20260109","doi-asserted-by":"crossref","first-page":"717\u201334","DOI":"10.1038\/s41569-024-01046-6","article-title":"Global epidemiology of heart failure","volume":"21","author":"Khan","year":"2024","journal-title":"Nat Rev Cardiol"},{"key":"R2-20260109","doi-asserted-by":"crossref","first-page":"e008406","DOI":"10.1161\/CIRCHEARTFAILURE.121.008406","article-title":"Prevalence and incidence of heart failure among urban patients in China: a national population-based analysis","volume":"14","author":"Wang","year":"2021","journal-title":"Circ Heart Fail"},{"key":"R3-20260109","doi-asserted-by":"crossref","first-page":"e611","DOI":"10.1016\/S2214-109X(23)00605-8","article-title":"Mortality in patients admitted to hospital with heart failure in China: a nationwide Cardiovascular Association Database-Heart Failure Centre Registry cohort study","volume":"12","author":"Wang","year":"2024","journal-title":"Lancet Glob Health"},{"key":"R4-20260109","doi-asserted-by":"crossref","first-page":"889\u201398","DOI":"10.1016\/j.athoracsur.2020.05.163","article-title":"Long-term survival after heart transplantation: a population-based nested case-control study","volume":"111","author":"Suarez-Pierre","year":"2021","journal-title":"Ann Thorac Surg"},{"key":"R5-20260109","doi-asserted-by":"crossref","first-page":"25\u201336","DOI":"10.1038\/s41569-023-00902-1","article-title":"Heart transplantation: advances in expanding the donor pool and xenotransplantation","volume":"21","author":"Jou","year":"2024","journal-title":"Nat Rev Cardiol"},{"key":"R6-20260109","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1001\/jama.2022.16197","article-title":"Five-year outcomes in patients with fully magnetically levitated vs axial-flow left ventricular assist devices in the MOMENTUM 3 randomized trial","volume":"328","author":"Mehra","year":"2022","journal-title":"JAMA"},{"key":"R7-20260109","first-page":"18","article-title":"2022 AHA\/ACC\/HFSA guideline for the management of heart failure: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"145","author":"Heidenreich","year":"2022","journal-title":"Circulation"},{"key":"R8-20260109","doi-asserted-by":"crossref","first-page":"613\u201325","DOI":"10.1093\/eurheartj\/ehad658","article-title":"Fully magnetically centrifugal left ventricular assist device and long-term outcomes: the ELEVATE registry","volume":"45","author":"Schmitto","year":"2024","journal-title":"Eur Heart J"},{"key":"R9-20260109","doi-asserted-by":"crossref","first-page":"S179","DOI":"10.1161\/CIRCULATIONAHA.110.011502","article-title":"Biventricular circulatory support with two miniaturized implantable assist devices","volume":"124","author":"Krabatsch","year":"2011","journal-title":"Circulation"},{"key":"R10-20260109","doi-asserted-by":"crossref","first-page":"722\u201332","DOI":"10.1016\/j.jchf.2021.05.009","article-title":"Advanced heart failure epidemiology and outcomes: a population-based study","volume":"9","author":"Dunlay","year":"2021","journal-title":"JACC Heart Fail"},{"key":"R11-20260109","doi-asserted-by":"crossref","first-page":"230\u201370","DOI":"10.1093\/ejcts\/ezz098","article-title":"2019 EACTS expert consensus on long-term mechanical circulatory support","volume":"56","author":"Potapov","year":"2019","journal-title":"Eur J Cardiothorac Surg"},{"key":"R12-20260109","doi-asserted-by":"crossref","first-page":"187\u2013219","DOI":"10.1016\/j.healun.2020.01.1329","article-title":"American Association for Thoracic Surgery\/International Society for Heart and Lung Transplantation guidelines on selected topics in mechanical circulatory support","volume":"39","author":"Kirklin","year":"2020","journal-title":"J Heart Lung Transplant"},{"key":"R13-20260109","doi-asserted-by":"crossref","first-page":"813\u201328","DOI":"10.1038\/s41569-022-00723-8","article-title":"The ongoing quest for the first total artificial heart as destination therapy","volume":"19","author":"Vis","year":"2022","journal-title":"Nat Rev Cardiol"},{"key":"R14-20260109","doi-asserted-by":"crossref","first-page":"1093\u2013101","DOI":"10.1016\/j.healun.2018.05.001","article-title":"Multicenter experience with durable biventricular assist devices","volume":"37","author":"Shah","year":"2018","journal-title":"J Heart Lung Transplant"},{"key":"R15-20260109","doi-asserted-by":"crossref","first-page":"822\u201324","DOI":"10.1016\/j.healun.2010.02.012","article-title":"Long-term biventricular support with the heartware implantable continuous flow pump","volume":"29","author":"Hetzer","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R16-20260109","doi-asserted-by":"crossref","first-page":"1037\u201345","DOI":"10.1093\/ejcts\/ezz173","article-title":"Results of primary biventricular support: an analysis of data from the EUROMACS registry","volume":"56","author":"Vierecke","year":"2019","journal-title":"Eur J Cardiothorac Surg"},{"key":"R17-20260109","doi-asserted-by":"crossref","first-page":"525\u201331","DOI":"10.1111\/aor.14933","article-title":"Two coupled continuous-flow ventricular assist devices as a novel BIVAD with one driveline-acute animal study results","volume":"49","author":"Knigge","year":"2025","journal-title":"Artif Organs"},{"key":"R18-20260109","first-page":"100082","article-title":"Transparency in the reporting of artificial intelligence \u2013 the TITAN guideline","volume":"10","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R19-20260109","doi-asserted-by":"crossref","first-page":"e1000412","DOI":"10.1371\/journal.pbio.1000412","article-title":"Improving bioscience research reporting: the ARRIVE guidelines for reporting animal research","volume":"8","author":"Kilkenny","year":"2010","journal-title":"PLoS Biol"},{"key":"R20-20260109","doi-asserted-by":"crossref","first-page":"33\u201344","DOI":"10.1016\/j.athoracsur.2023.11.004","article-title":"The Society of Thoracic Surgeons Intermacs 2023 annual report: focus on magnetically levitated devices","volume":"117","author":"Jorde","year":"2024","journal-title":"Ann Thorac Surg"},{"key":"R21-20260109","doi-asserted-by":"crossref","first-page":"1234516","DOI":"10.3389\/fcvm.2023.1234516","article-title":"Current and future options for adult biventricular assistance: a review of literature","volume":"10","author":"Loardi","year":"2023","journal-title":"Front Cardiovasc Med"},{"key":"R22-20260109","doi-asserted-by":"crossref","first-page":"661\u201372","DOI":"10.1182\/blood.2022018096","article-title":"Hemocompatibility and biophysical interface of left ventricular assist devices and total artificial hearts","volume":"143","author":"Nascimbene","year":"2024","journal-title":"Blood"},{"key":"R23-20260109","doi-asserted-by":"crossref","first-page":"69\u201380","DOI":"10.21037\/acs.2020.03.07","article-title":"Comparison of SynCardia total artificial heart and HeartWare HVAD biventricular support for management of biventricular heart failure: a systematic review and meta-analysis","volume":"9","author":"Maynes","year":"2020","journal-title":"Ann Cardiothorac Surg"},{"key":"R24-20260109","doi-asserted-by":"crossref","first-page":"383\u201390","DOI":"10.1016\/j.athoracsur.2023.02.058","article-title":"Timing and outcomes of concurrent and sequential biventricular assist device implantation: a Society of Thoracic Surgeons Intermacs analysis","volume":"116","author":"Ahmed","year":"2023","journal-title":"Ann Thorac Surg"},{"key":"R25-20260109","doi-asserted-by":"crossref","first-page":"90\u201397","DOI":"10.1002\/ejhf.1284","article-title":"Long-term evaluation of a fully magnetically levitated circulatory support device for advanced heart failure-two-year results from the HeartMate 3\u2009CE mark study","volume":"21","author":"Schmitto","year":"2019","journal-title":"Eur J Heart Fail"},{"key":"R26-20260109","doi-asserted-by":"crossref","first-page":"1399\u2013402","DOI":"10.1016\/j.healun.2018.08.008","article-title":"An international multicenter experience of biventricular support with HeartMate 3 ventricular assist systems","volume":"37","author":"Lavee","year":"2018","journal-title":"J Heart Lung Transplant"},{"key":"R27-20260109","doi-asserted-by":"crossref","first-page":"220\u201328","DOI":"10.1016\/j.healun.2020.11.012","article-title":"Outcomes after heart transplantation and total artificial heart implantation: a multicenter study","volume":"40","author":"Carrier","year":"2021","journal-title":"J Heart Lung Transplant"},{"key":"R28-20260109","doi-asserted-by":"crossref","first-page":"544\u201351","DOI":"10.1097\/MAT.0000000000001900","article-title":"HeartMate-3 ventricular assist devices versus the total artificial heart for biventricular support: a single-center series","volume":"69","author":"Satish","year":"2023","journal-title":"ASAIO J"},{"key":"R29-20260109","doi-asserted-by":"crossref","first-page":"193\u2013200","DOI":"10.1016\/j.healun.2020.12.006","article-title":"The results of a single-center experience with HeartMate 3 in a biventricular configuration","volume":"40","author":"McGiffin","year":"2021","journal-title":"J Heart Lung Transplant"},{"key":"R30-20260109","doi-asserted-by":"crossref","first-page":"939\u201340","DOI":"10.1093\/icvts\/ivac009","article-title":"Heartmate 3 implantation in small patients: CT-guided chest diameter assessment","volume":"34","author":"Van Puyvelde","year":"2022","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"R31-20260109","doi-asserted-by":"crossref","first-page":"281\u201388","DOI":"10.21037\/acs-2020-cfmcs-28","article-title":"Conventional and alternative sites for left ventricular assist device inflow and outflow cannula placement","volume":"10","author":"Loforte","year":"2021","journal-title":"Ann Cardiothorac Surg"},{"key":"R32-20260109","doi-asserted-by":"crossref","first-page":"230\u201346","DOI":"10.1053\/j.optechstcvs.2024.01.001","article-title":"Fully magnetically levitated durable biventricular assist device insertion","volume":"29","author":"Ziegler","year":"2024","journal-title":"Oper Tech Thorac Cardiovasc Surg"},{"key":"R33-20260109","doi-asserted-by":"crossref","first-page":"926\u201334","DOI":"10.1111\/aor.13675","article-title":"Right atrial versus right ventricular HeartWare HVAD position in patients on biventricular HeartWare HVAD support: a systematic review","volume":"44","author":"Maynes","year":"2020","journal-title":"Artif Organs"},{"key":"R34-20260109","doi-asserted-by":"crossref","first-page":"466\u201373","DOI":"10.1016\/j.healun.2015.12.001","article-title":"Long-term biventricular HeartWare ventricular assist device support\u2013case series of right atrial and right ventricular implantation outcomes","volume":"35","author":"Shehab","year":"2016","journal-title":"J Heart Lung Transplant"},{"key":"R35-20260109","doi-asserted-by":"crossref","first-page":"655\u201364","DOI":"10.1111\/aor.14741","article-title":"HeartMate 3 implantation with an emphasis on the biventricular configuration","volume":"48","author":"Marasco","year":"2024","journal-title":"Artif Organs"},{"key":"R36-20260109","doi-asserted-by":"crossref","first-page":"4341\u201351","DOI":"10.21037\/jtd-22-325","article-title":"Analysis of systemic vascular resistance after cardiac surgery: a retrospective cohort study","volume":"14","author":"Umeki","year":"2022","journal-title":"J Thorac Dis"},{"key":"R37-20260109","doi-asserted-by":"crossref","first-page":"140\u201344","DOI":"10.1053\/j.semtcvs.2010.09.007","article-title":"Vasoplegia during cardiac surgery: current concepts and management","volume":"22","author":"Fischer","year":"2010","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"R38-20260109","doi-asserted-by":"crossref","first-page":"64\u201374","DOI":"10.1016\/j.niox.2024.03.004","article-title":"Inhaled nitric oxide and postoperative outcomes in cardiac surgery with cardiopulmonary bypass: a systematic review and meta-analysis","volume":"146","author":"Yan","year":"2024","journal-title":"Nitric Oxide-biol Ch"},{"key":"R39-20260109","doi-asserted-by":"crossref","first-page":"800\u201304","DOI":"10.1164\/ajrccm.165.6.2106079","article-title":"Continuous subcutaneous infusion of treprostinil, a prostacyclin analogue, in patients with pulmonary arterial hypertension: a double-blind, randomized, placebo-controlled trial","volume":"165","author":"Simonneau","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"R40-20260109","doi-asserted-by":"crossref","first-page":"509\u201311","DOI":"10.1161\/CIRCULATIONAHA.124.069726","article-title":"A prospective randomized trial of direct oral anticoagulant therapy with a fully magnetically levitated LVAD: the DOT-HM3 study","volume":"150","author":"Netuka","year":"2024","journal-title":"Circulation"},{"key":"R41-20260109","doi-asserted-by":"crossref","first-page":"1199\u2013234","DOI":"10.1016\/j.healun.2024.04.065","article-title":"An ISHLT consensus statement on strategies to prevent and manage hemocompatibility related adverse events in patients with a durable, continuous-flow ventricular assist device","volume":"43","author":"Hollis","year":"2024","journal-title":"J Heart Lung Transplant"},{"key":"R42-20260109","doi-asserted-by":"crossref","first-page":"2771\u201379","DOI":"10.1007\/s10554-022-02683-z","article-title":"Left ventricular assist device and pump thrombosis: the importance of the inflow cannula position","volume":"38","author":"Kortekaas","year":"2022","journal-title":"Int J Cardiovasc Imaging"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000002879","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T13:00:41Z","timestamp":1767963641000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000002879"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,23]]},"references-count":42,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000002879","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,23]]},"assertion":[{"value":"2025-03-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}