{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T13:44:06Z","timestamp":1783518246830,"version":"3.55.0"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T00:00:00Z","timestamp":1751500800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:p>Inadvertent perioperative hypothermia (IPH) is a common perioperative complication in developing countries, and effective assessment tools for IPH risk stratification are still needed in these regions. In this letter, we report a validated mobile phone app-based heart rate variability (HRV) analysis procedure used in 220 adult patients scheduled for abdominal surgery to explore the relationship between preoperative 5-minute HRV metrics and IPH. Multivariate logistic regression analysis identified the HRV metric\u2014the ratio of low\u2014to high-frequency power (LF\/HF)\u2014as superior to previously reported clinical IPH predictors. For the outcomes of IPH within the first 30\u00a0minutes and 1 hour of surgery, receiver operating characteristic curves for regression models including both baseline core temperature and LF\/HF showed area under the curve values of 0.96 (95% confidence interval, 0.93\u20130.98) and 0.92 (95% confidence interval, 0.87\u20130.96), respectively. Our results suggest that the HRV metric LF\/HF, generated via a wearable sensor during patients\u2019 5-minute preoperative adaptation to the operating room ambient temperature (22\u00b0C\u201323\u00b0C), may serve as a promising biomarker for IPH in future research.<\/jats:p>","DOI":"10.1097\/js9.0000000000002882","type":"journal-article","created":{"date-parts":[[2025,7,3]],"date-time":"2025-07-03T10:00:47Z","timestamp":1751536847000},"page":"7359-7362","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Wearable sensor-derived heart rate variability (LF\/HF): a promising biomarker for predicting inadvertent perioperative hypothermia"],"prefix":"10.1097","volume":"111","author":[{"given":"Ling","family":"Shen","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Eastern Hepatobiliary Surgery Hospital, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Wei","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Eastern Hepatobiliary Surgery Hospital, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongmei","family":"Xiao","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Eastern Hepatobiliary Surgery Hospital, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Ji","sequence":"additional","affiliation":[{"name":"Department of Intensive Care Unit, Eastern Hepatobiliary Surgery Hospital, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1683-3424","authenticated-orcid":false,"given":"Kunming","family":"Tao","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Eastern Hepatobiliary Surgery Hospital, Shanghai, China"},{"name":"Key Laboratory of Anesthesiology (Shanghai Jiao Tong University), Ministry of Education, Shanghai, China"},{"name":"Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,3]]},"reference":[{"key":"R1-20260109","doi-asserted-by":"crossref","first-page":"e18","DOI":"10.1111\/anae.14921","article-title":"Towards high-quality peri-operative care: a global perspective","volume":"75","author":"Santhirapala","year":"2020","journal-title":"Anaesthesia"},{"key":"R2-20260109","doi-asserted-by":"crossref","first-page":"6941\u201352","DOI":"10.1097\/JS9.0000000000002021","article-title":"Perioperative hypothermia and stress jeopardize antimetastatic immunity and TLR-9 immune activation: potential mediating mechanisms (experimental studies)","volume":"110","author":"Sandbank","year":"2024","journal-title":"Int J Surg"},{"key":"R3-20260109","doi-asserted-by":"crossref","first-page":"525\u201339","DOI":"10.1146\/annurev-publhealth-052620-093850","article-title":"Mobile health (mHealth) in low-and middle-income countries","volume":"43","author":"McCool","year":"2022","journal-title":"Annu Rev Public Health"},{"key":"R4-20260109","doi-asserted-by":"crossref","first-page":"6806225","DOI":"10.1155\/2022\/6806225","article-title":"Validation of a prediction model for intraoperative hypothermia in patients receiving general anesthesia","volume":"2022","author":"Dai","year":"2022","journal-title":"Int J Clin Pract"},{"key":"R5-20260109","doi-asserted-by":"crossref","first-page":"1124\u201333","DOI":"10.1016\/j.scitotenv.2017.10.208","article-title":"Experimental study on the human thermal comfort based on the heart rate variability (HRV) analysis under different environments","volume":"616-617","author":"Zhu","year":"2018","journal-title":"Sci Total Environ"},{"key":"R6-20260109","doi-asserted-by":"crossref","first-page":"507\u201318","DOI":"10.1007\/s10286-022-00884-z","article-title":"Self-recorded heart rate variability profiles are associated with health and lifestyle markers in young adults","volume":"32","author":"Grosicki","year":"2022","journal-title":"Clin Auton Res"},{"key":"R7-20260109","first-page":"100082","article-title":"Transparency in the reporting of Artificial INtelligence-the TITAN guideline","volume":"10","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R8-20260109","doi-asserted-by":"crossref","first-page":"6536","DOI":"10.3390\/s22176536","article-title":"Validity of the Polar H10 sensor for heart rate variability analysis during resting state and incremental exercise in recreational men and women","volume":"22","author":"Schaffarczyk","year":"2022","journal-title":"Sensors (Basel)"},{"key":"R9-20260109","doi-asserted-by":"crossref","first-page":"106696","DOI":"10.1016\/j.cmpb.2022.106696","article-title":"Validity and reliability of different smartphones applications to measure HRV during short and ultra-short measurements in elite athletes","volume":"217","author":"Moya-Ramon","year":"2022","journal-title":"Comput Methods Programs Biomed"},{"key":"R10-20260109","doi-asserted-by":"crossref","first-page":"22296","DOI":"10.1038\/s41598-021-01743-z","article-title":"Development and internal validation of an algorithm to predict intraoperative risk of inadvertent hypothermia based on preoperative data","volume":"11","author":"Wallisch","year":"2021","journal-title":"Sci Rep"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000002882","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T13:02:28Z","timestamp":1767963748000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000002882"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,3]]},"references-count":10,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000002882","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,3]]},"assertion":[{"value":"2025-02-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-13","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}