{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T22:53:56Z","timestamp":1791586436235,"version":"4.3.4"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2025,6,26]],"date-time":"2025-06-26T00:00:00Z","timestamp":1750896000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Because of its ability to identify isoattenuating gallstones, electron density (Rho) and effective atomic number (Z) maps derived from dual-energy computed tomography (CT) hold promise for secondary choledocholithiasis detection in lieu of magnetic resonance cholangiopancreatography (MRCP). The aim of this study was to investigate the diagnostic performance of dual-energy CT Rho\/Z maps in detecting secondary choledocholithiasis in patients with gallbladder stones.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods:<\/jats:title>\n                    <jats:p>This retrospective single-center study included patients who underwent unenhanced abdominal dual-energy CT and MRCP for suspected secondary choledocholithiasis between July 2019 and March 2023. Conventional CT, Rho and Z images were generated. Two radiologists performed blinded consensus choledocholithiasis evaluation in four reading sessions (session 1, conventional CT images; session 2, Rho maps alone; session 3, Z maps alone; session 4, Rho plus Z maps). Diagnostic performance in choledocholithiasis detection was compared between reading sessions using the McNemar and DeLong tests.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 89 patients (mean age, 54\u00a0years\u00a0\u00b1\u00a013 [SD]; 45 male) were enrolled, including 41 patients (48.2%) with secondary choledocholithiasis. Diagnostic performance was greater with Rho plus Z maps compared with conventional CT for choledocholithiasis detection, with an area under the receiver operating characteristic curve (AUC) of 0.734 for conventional CT and 0.855 for Rho plus Z maps (P\u00a0=\u00a0.007); corresponding sensitivities were 51.2% (22 of 43 patients) for conventional CT and 74.4% (32 of 43 patients) for Rho plus Z maps (P\u00a0=\u00a0.004). The corresponding specificities were equal (95.7%, 44 of 46 patients) (P\u00a0=\u00a01.000). Additionally, Rho plus Z maps achieved comparable diagnostic performance with MRCP for diagnosing choledocholithiasis (AUCs: 0.855 vs 0.875, P =\u00a0.526).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Combined use of Rho and Z maps from unenhanced dual-energy CT improved detection of secondary choledocholithiasis compared with conventional CT and held promise for an alternative to MRCP.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000002886","type":"journal-article","created":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T08:00:15Z","timestamp":1751011215000},"page":"6638-6646","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Diagnostic accuracy of dual-energy CT Rho\/Z maps for detecting secondary choledocholithiasis"],"prefix":"10.1097","volume":"111","author":[{"given":"Hui-Hui","family":"Zhang","sequence":"first","affiliation":[{"name":"Department of Radiology, Hunan Provincial People\u2019s Hospital and the First Affiliated Hospital of Hunan Normal University, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chang-Hui","family":"Xiao","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hunan Provincial People\u2019s Hospital and the First Affiliated Hospital of Hunan Normal University, Changsha, China"},{"name":"Department of Radiology, Changde Hospital, Xiangya School of Medicine, Central South University, Changde, Hunan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fan","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hunan Provincial People\u2019s Hospital and the First Affiliated Hospital of Hunan Normal University, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hunan Provincial People\u2019s Hospital and the First Affiliated Hospital of Hunan Normal University, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hunan Provincial People\u2019s Hospital and the First Affiliated Hospital of Hunan Normal University, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9319-1237","authenticated-orcid":false,"given":"Xian-Zheng","family":"Tan","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hunan Provincial People\u2019s Hospital and the First Affiliated Hospital of Hunan Normal University, Changsha, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,6,26]]},"reference":[{"key":"R1-20260109","first-page":"148\u201358","article-title":"The treatment of gallstone disease","volume":"117","author":"Gutt","year":"2020","journal-title":"Dtsch Arztebl Int"},{"key":"R2-20260109","doi-asserted-by":"crossref","first-page":"470\u201378","DOI":"10.1148\/radiol.2021201115","article-title":"Percutaneous Transhepatic Papillary Balloon Dilation versus Endoscopic Retrograde Cholangiopancreatography for Common Bile Duct Stones: a Multicenter Prospective Study","volume":"300","author":"Liu","year":"2021","journal-title":"Radiology"},{"key":"R3-20260109","doi-asserted-by":"crossref","first-page":"1067\u201374","DOI":"10.7150\/ijms.52974","article-title":"Advances in risk factors for recurrence of common bile duct stones","volume":"18","author":"Wu","year":"2021","journal-title":"Int J Med Sci"},{"key":"R4-20260109","doi-asserted-by":"crossref","first-page":"118\u201326","DOI":"10.1148\/radiol.2021210607","article-title":"Early prediction of acute biliary pancreatitis using clinical and abdominal CT features","volume":"302","author":"Zver","year":"2022","journal-title":"Radiology"},{"key":"R5-20260109","doi-asserted-by":"crossref","first-page":"6447\u201357","DOI":"10.1007\/s00330-019-06258-w","article-title":"Combination of CT findings can reliably predict radiolucent common bile duct stones: a novel approach using a CT-based nomogram","volume":"29","author":"Min","year":"2019","journal-title":"Eur Radiol"},{"key":"R6-20260109","doi-asserted-by":"crossref","first-page":"60\u201367","DOI":"10.1056\/NEJMra2304821","article-title":"Acute Abdomen in the Modern Era","volume":"391","author":"Rogers","year":"2024","journal-title":"N Engl J Med"},{"key":"R7-20260109","doi-asserted-by":"crossref","first-page":"e231112","DOI":"10.1001\/jamasurg.2023.1112","article-title":"Diagnostic Accuracy of Unenhanced Computed Tomography for evaluation of acute abdominal pain in the Emergency Department","volume":"158","author":"Shaish","year":"2023","journal-title":"JAMA Surg"},{"key":"R8-20260109","doi-asserted-by":"crossref","first-page":"452","DOI":"10.3390\/medicina61030452","article-title":"Perforated calculous cholecystitis and incidental squamous cell carcinoma of the gallbladder-a complex relationship with a difficult management in the acute setting","volume":"61","author":"Zanchetta","year":"2025","journal-title":"Medicina (Kaunas)"},{"key":"R9-20260109","doi-asserted-by":"crossref","first-page":"407\u201308","DOI":"10.1148\/radiol.2019191172","article-title":"Will dual-energy CT become the reference standard to evaluate gallstone disease?","volume":"292","author":"Matos","year":"2019","journal-title":"Radiology"},{"key":"R10-20260109","doi-asserted-by":"crossref","first-page":"400\u201306","DOI":"10.1148\/radiol.2019190083","article-title":"A technique to identify isoattenuating gallstones with dual-layer spectral CT: an ex vivo phantom study","volume":"292","author":"Soesbe","year":"2019","journal-title":"Radiology"},{"key":"R11-20260109","first-page":"2933\u201339","article-title":"Making the invisible visible: improving conspicuity of noncalcified gallstones using dual-energy CT","volume":"42","author":"Uyeda","year":"2017","journal-title":"Abdom Radiol (NY)"},{"key":"R12-20260109","doi-asserted-by":"crossref","first-page":"35\u201341","DOI":"10.1097\/RCT.0000000000001535","article-title":"Gallstones detection on dual-energy computerized tomography-is it ready for real-world use? A retrospective observational study","volume":"48","author":"Guha Roy","year":"2024","journal-title":"J Comput Assist Tomogr"},{"key":"R13-20260109","doi-asserted-by":"crossref","first-page":"478\u201382","DOI":"10.1016\/j.acra.2016.10.006","article-title":"Clinical Application of Dual-Energy Spectral Computed Tomography in detecting cholesterol gallstones from surrounding bile","volume":"24","author":"Yang","year":"2017","journal-title":"Acad Radiol"},{"key":"R14-20260109","doi-asserted-by":"crossref","first-page":"292\u201398","DOI":"10.1016\/j.diii.2024.02.004","article-title":"Incremental diagnostic value of virtual non-contrast dual-energy CT for the diagnosis of choledocholithiasis over conventional unenhanced CT","volume":"105","author":"Xiao","year":"2024","journal-title":"Diagn Interv Imaging"},{"key":"R15-20260109","doi-asserted-by":"crossref","first-page":"34\u201340","DOI":"10.1016\/j.ejrad.2019.04.008","article-title":"Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: virtual non-contrast image can replace true non-contrast image regarding biliary stone detection","volume":"116","author":"Bae","year":"2019","journal-title":"Eur J Radiol"},{"key":"R16-20260109","doi-asserted-by":"crossref","first-page":"74\u201380","DOI":"10.2214\/AJR.15.14570","article-title":"Comparison of virtual unenhanced images derived from dual-energy CT with true unenhanced images in evaluation of gallstone disease","volume":"206","author":"Lee","year":"2016","journal-title":"AJR Am J Roentgenol"},{"key":"R17-20260109","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1148\/radiol.2020192421","article-title":"Dual-energy CT of gallstone ileus","volume":"295","author":"Liu","year":"2020","journal-title":"Radiology"},{"key":"R18-20260109","first-page":"100082","article-title":"Transparency in the reporting of Artificial INtelligence \u2013 the TITAN guideline","volume":"10","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R19-20260109","doi-asserted-by":"crossref","first-page":"381\u201390","DOI":"10.1148\/radiol.2019181100","article-title":"Virtual unenhanced images at dual-energy CT: influence on renal lesion characterization","volume":"291","author":"Meyer","year":"2019","journal-title":"Radiology"},{"key":"R20-20260109","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1016\/j.gie.2018.10.001","article-title":"ASGE guideline on the role of endoscopy in the evaluation and management of choledocholithiasis","volume":"89","author":"Buxbaum","year":"2019","journal-title":"Gastrointest Endosc"},{"key":"R21-20260109","first-page":"472\u201391","article-title":"Endoscopic management of common bile duct stones: European Society of Gastrointestinal Endoscopy (ESGE) guideline","volume":"51","author":"Manes","year":"2019","journal-title":"Endoscopy"},{"key":"R22-20260109","doi-asserted-by":"crossref","first-page":"247\u201348","DOI":"10.1016\/j.diii.2024.02.011","article-title":"Dual-energy CT: bridging the gap between innovation and clinical practice","volume":"105","author":"Calame","year":"2024","journal-title":"Diagn Interv Imaging"},{"key":"R23-20260109","doi-asserted-by":"crossref","first-page":"7334\u201346","DOI":"10.1007\/s00330-024-10782-9","article-title":"Electron density dual-energy CT can improve the detection of lumbar disc herniation with higher image quality than standard and virtual non-calcium images","volume":"34","author":"Jeong","year":"2024","journal-title":"Eur Radiol"},{"key":"R24-20260109","doi-asserted-by":"crossref","first-page":"7934\u201343","DOI":"10.1007\/s00330-024-10820-6","article-title":"In vitro blood sample assessment: investigating correlation of laboratory hemoglobin and spectral properties of dual-energy CT measurements (rho\/Z)","volume":"34","author":"Schulz","year":"2024","journal-title":"Eur Radiol"},{"key":"R25-20260109","doi-asserted-by":"crossref","first-page":"2209\u201320","DOI":"10.1007\/s00330-021-08374-y","article-title":"Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images","volume":"32","author":"Shim","year":"2022","journal-title":"Eur Radiol"},{"key":"R26-20260109","doi-asserted-by":"crossref","first-page":"e222680","DOI":"10.1148\/radiol.222680","article-title":"Spinal Hematoma visualized with dual-energy CT-derived electron density overlay maps","volume":"307","author":"Nelles","year":"2023","journal-title":"Radiology"},{"key":"R27-20260109","doi-asserted-by":"crossref","first-page":"479\u201380","DOI":"10.1148\/radiol.2021210890","article-title":"Management of choledocholithiasis: interventional radiologists continue to push the envelope","volume":"300","author":"vanSonnenberg","year":"2021","journal-title":"Radiology"},{"key":"R28-20260109","doi-asserted-by":"crossref","first-page":"1587\u201394","DOI":"10.1007\/s00261-015-0387-y","article-title":"Clinical value of spectral CT in diagnosis of negative gallstones and common bile duct stones","volume":"40","author":"Li","year":"2015","journal-title":"Abdom Imaging"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000002886","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T13:02:43Z","timestamp":1767963763000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000002886"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,26]]},"references-count":28,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000002886","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,26]]},"assertion":[{"value":"2025-03-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}