{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T16:04:01Z","timestamp":1791821041386,"version":"4.3.4"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T00:00:00Z","timestamp":1753315200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The aim of this retrospective study and systematic review was to examine the causes, management strategies, and outcomes of thoracic endovascular aortic repair (TEVAR) stent graft misplacement in the false lumen (FL). Accordingly, we analyzed cases from China Medical University Hospital along with data from published articles.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>This single-center retrospective study analyzed six TEVAR stent graft misplacement cases among 1227 patients who had an aortic dissection and underwent TEVAR at China Medical University Hospital (2011\u20132024). Furthermore, a systematic search of PubMed, Embase, Web of Science, and Cochrane CENTRAL and ClinicalTrials.gov for relevant studies was performed. Outcome data on symptoms, clinical outcomes, placement method, management strategies, treatment quality, potential causes of misplacement, and factors related to oversight were independently extracted by two reviewers in a standardized manner.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 35 cases from 23 studies, including 6 from our institution, were reviewed. TEVAR misplacement predominantly occurred in type A dissections (62.9%) and in cases of anterogradely placed TEVAR stents (68.6%). Complications, mainly visceral malperfusion (48.6%), were reported in 77.1% of the cases. Intraoperative misplacement was more accurately detected by transesophageal echocardiogram (TEE) or intravascular ultrasound (IVUS) than by aortography alone (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Endovascular retrograde stent extension with or without septal fenestration was linked to improved survival (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =\u00a00.018). Early symptom onset within 3\u00a0days and delayed treatment increased mortality (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =\u00a00.029). Overall mortality was 28.6%, mainly due to multiorgan failure (80%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Although rare, accidental TEVAR stent graft placement in the FL markedly increases mortality. Despite seemingly acceptable survival rates, challenges in diagnosis and the potential for publication bias may lead to misleading conclusions. Clinicians must immediately administer comprehensive aortography, TEE, IVUS, or intraoperative computed tomography when they suspect an instance of accidental placement to ensure timely intervention.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000003028","type":"journal-article","created":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T17:00:20Z","timestamp":1753376420000},"page":"8529-8539","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Inadvertent placement of thoracic stent grafts in false lumen during aortic dissection surgery \u2013 unicentric analysis and systematic review"],"prefix":"10.1097","volume":"111","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-9747-3519","authenticated-orcid":false,"given":"Hsiu-Ming","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Surgery, Chang Gung Memorial Hospital at Linkou, Chang Gung University, Taoyuan, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying Sheng","family":"Li","sequence":"additional","affiliation":[{"name":"Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital at Linkou, Chang Gung University, Taoyuan, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingli Levin","family":"Li","sequence":"additional","affiliation":[{"name":"Cardiovascular Surgery, China Medical University Hospital, Taichung City, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,7,24]]},"reference":[{"key":"R1-20260512","doi-asserted-by":"crossref","first-page":"152\u201362","DOI":"10.1053\/j.optechstcvs.2019.10.002","article-title":"Frozen elephant trunk procedure","volume":"24","author":"Arnaoutakis","year":"2019","journal-title":"Oper Tech Thorac Cardiovasc Surg"},{"key":"R2-20260512","doi-asserted-by":"crossref","first-page":"708\u201321","DOI":"10.21037\/cdt-22-330","article-title":"The frozen elephant trunk procedure: indications, outcomes and future directions","volume":"12","author":"Acharya","year":"2022","journal-title":"Cardiovasc Diagn Ther"},{"key":"R3-20260512","doi-asserted-by":"crossref","first-page":"205\u201307","DOI":"10.34172\/jcvtr.2022.24","article-title":"Total endovascular repair of a malpositioned frozen elephant trunk with Thoraflex hybrid prosthesis: a case report","volume":"14","author":"Buia","year":"2022","journal-title":"J Cardiovasc Thorac Res"},{"key":"R4-20260512","doi-asserted-by":"crossref","first-page":"3426\u201327","DOI":"10.1111\/jocs.16780","article-title":"Thoracic endovascular aortic repair (TEVAR) to retrieve a stented elephant trunk graft entrapped in the false lumen of dissection patients","volume":"37","author":"Gao","year":"2022","journal-title":"J Card Surg"},{"key":"R5-20260512","first-page":"598\u2013600","article-title":"Endovascular fenestration of aortic dissection membrane after failed frozen elephant trunk procedure","volume":"57","author":"Raupach","year":"2020","journal-title":"Eur J Cardiothorac Surg"},{"key":"R6-20260512","doi-asserted-by":"crossref","first-page":"1222\u201324","DOI":"10.1093\/ejcts\/ezy357","article-title":"Incorrect frozen elephant trunk deployment into the false lumen of a patient with complicated type B acute dissection","volume":"55","author":"Fujii","year":"2019","journal-title":"Eur J Cardiothorac Surg"},{"key":"R7-20260512","doi-asserted-by":"crossref","first-page":"971\u201378","DOI":"10.1161\/CIRCULATIONAHA.110.015081","article-title":"Total arch replacement combined with stented elephant trunk implantation: a new \u201cstandard\u201d therapy for type a dissection involving repair of the aortic arch?","volume":"123","author":"Sun","year":"2011","journal-title":"Circulation"},{"key":"R8-20260512","doi-asserted-by":"crossref","DOI":"10.70389\/PJS.100082","article-title":"Transparency In The reporting of Artificial INtelligence \u2013 the TITAN guideline","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R9-20260512","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"R10-20260512","doi-asserted-by":"crossref","first-page":"j4008","DOI":"10.1136\/bmj.j4008","article-title":"AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both","volume":"358","author":"Shea","year":"2017","journal-title":"BMJ"},{"key":"R11-20260512","doi-asserted-by":"crossref","first-page":"S39","DOI":"10.1016\/j.ejvs.2021.01.032","article-title":"Endovascular exclusion of a post-dissection thoraco-abdominal aneurysm with false lumen implant of frozen elephant trunk + branched EVAR","volume":"61","author":"Catarino","year":"2021","journal-title":"Eur J Vasc Endovascular Surg"},{"key":"R12-20260512","doi-asserted-by":"crossref","first-page":"264\u201367","DOI":"10.1016\/j.jvs.2013.07.101","article-title":"Hybrid endovascular repair of a dissecting thoracoabdominal aortic aneurysm with stent graft implantation through the false lumen","volume":"59","author":"Watanabe","year":"2014","journal-title":"J Vasc Surg"},{"key":"R13-20260512","first-page":"101\u201303","article-title":"Rapid false lumen dilation and pseudocoarctation due to inadvertent preferential false lumen perfusion using the frozen elephant trunk technique in a chronic residual aortic dissection","volume":"6","author":"Fleerakkers","year":"2020","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"R14-20260512","doi-asserted-by":"crossref","first-page":"e81","DOI":"10.1016\/j.athoracsur.2021.08.014","article-title":"Spontaneous dislocation of a frozen elephant trunk stent graft into the false lumen","volume":"113","author":"Kreibich","year":"2022","journal-title":"Ann Thorac Surg"},{"key":"R15-20260512","doi-asserted-by":"crossref","first-page":"101095","DOI":"10.1016\/j.jvscit.2023.101095","article-title":"Trans-sternotomy, snare-assisted thoracic endovascular aortic repair for redirection of a migrated elephant trunk","volume":"9","author":"Fereydooni","year":"2023","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"R16-20260512","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.jvs.2015.05.040","article-title":"Endovascular rescue of an elephant trunk initially positioned in the false lumen of an aortic dissection","volume":"64","author":"Crunelle","year":"2016","journal-title":"J Vasc Surg"},{"key":"R17-20260512","doi-asserted-by":"crossref","first-page":"1770\u201373","DOI":"10.1007\/s00270-016-1453-8","article-title":"Endovascular retrieval of entrapped elephant trunk graft during complex hybrid aortic arch repair","volume":"39","author":"Damodharan","year":"2016","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R18-20260512","first-page":"566\u201370","article-title":"Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk","volume":"6","author":"Chen","year":"2020","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"R19-20260512","first-page":"954\u201362","article-title":"Total endovascular repair of an intraoperative stent-graft deployed in the false lumen of Stanford type A aortic dissection: a case report","volume":"8","author":"Li","year":"2020","journal-title":"World J Clin Cases"},{"key":"R20-20260512","doi-asserted-by":"crossref","first-page":"1213\u201317","DOI":"10.1007\/BF02482276","article-title":"Impending rupture of the descending aorta by enlargement of the false lumen after graft replacement with the elephant trunk technique: report of a case","volume":"29","author":"Koshino","year":"1999","journal-title":"Surg Today"},{"key":"R21-20260512","first-page":"217\u201320","article-title":"An elephant trunk stent graft strayed into the false lumen leading to a death during the Sun\u2019s operation: a case report","volume":"46","author":"Zhou","year":"2021","journal-title":"Zhong Nan Da Xue Xue Bao Yi Xue Ban"},{"key":"R22-20260512","doi-asserted-by":"crossref","first-page":"e409","DOI":"10.1016\/j.athoracsur.2021.08.006","article-title":"Endovascular rerouting the errant aortic endoprosthesis","volume":"113","author":"Dervishi","year":"2022","journal-title":"Ann Thorac Surg"},{"key":"R23-20260512","doi-asserted-by":"crossref","first-page":"60\u201363","DOI":"10.1136\/bmjebm-2017-110853","article-title":"Methodological quality and synthesis of case series and case reports","volume":"23","author":"Murad","year":"2018","journal-title":"BMJ Evid Based Med"},{"key":"R24-20260512","doi-asserted-by":"crossref","first-page":"529\u201342","DOI":"10.1007\/s10286-021-00801-w","article-title":"Dyskinesia-hyperpyrexia syndrome in Parkinson\u2019s disease: a systematic review","volume":"31","author":"Wang","year":"2021","journal-title":"Clin Auton Res"},{"key":"R25-20260512","doi-asserted-by":"crossref","first-page":"e479","DOI":"10.1016\/j.athoracsur.2016.12.039","article-title":"Endovascular fenestration for distal aortic sealing after frozen elephant trunk with Thoraflex","volume":"103","author":"Wong","year":"2017","journal-title":"Ann Thorac Surg"},{"key":"R26-20260512","doi-asserted-by":"crossref","first-page":"518\u201322","DOI":"10.1016\/j.jvs.2014.11.072","article-title":"Endovascular rescue after inadvertent false lumen stent graft implantation","volume":"63","author":"Han","year":"2016","journal-title":"J Vasc Surg"},{"key":"R27-20260512","first-page":"553\u201356","article-title":"Endovascular septal fenestration using a radiofrequency wire to salvage inadvertent false lumen deployment of a frozen elephant trunk stent graft","volume":"5","author":"Plotkin","year":"2019","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"R28-20260512","doi-asserted-by":"crossref","first-page":"176\u201379","DOI":"10.1007\/s00270-011-0267-y","article-title":"JAG tearing technique with radiofrequency guide wire for aortic fenestration in thoracic endovascular aneurysm repair","volume":"35","author":"Ricci","year":"2012","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R29-20260512","doi-asserted-by":"crossref","first-page":"242\u201346","DOI":"10.1177\/1526602818759756","article-title":"Reentry devices for lamella neofenestration during endovascular aortic repair of chronic type B aortic dissection","volume":"25","author":"Bertoglio","year":"2018","journal-title":"J Endovasc Ther"},{"key":"R30-20260512","doi-asserted-by":"crossref","first-page":"101402","DOI":"10.1016\/j.jvscit.2023.101402","article-title":"Transcatheter electrosurgical septotomy technique for chronic postdissection aortic aneurysms","volume":"10","author":"Baghbani-Oskouei","year":"2024","journal-title":"J Vasc Surg Cases Innov Tech"},{"key":"R31-20260512","doi-asserted-by":"crossref","first-page":"2078\u201384","DOI":"10.1016\/j.athoracsur.2011.08.018","article-title":"Distal landing zone open fenestration facilitates endovascular elephant trunk completion and false lumen thrombosis","volume":"92","author":"Roselli","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"R32-20260512","doi-asserted-by":"crossref","first-page":"e41","DOI":"10.1016\/j.jtcvs.2015.10.083","article-title":"Successful endoluminal rescue of an endovascular graft unintentionally deployed in the false lumen of Stanford type B aortic dissection","volume":"151","author":"Ma","year":"2016","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R33-20260512","doi-asserted-by":"crossref","first-page":"151\u201356","DOI":"10.1177\/15266028221112259","article-title":"Endovascular rescue aortic fenestration after accidental false lumen TEVAR in type B dissection","volume":"31","author":"Massmann","year":"2024","journal-title":"J Endovasc Ther"},{"key":"R34-20260512","doi-asserted-by":"crossref","first-page":"3948\u201351","DOI":"10.1111\/jocs.15846","article-title":"Endovascular rescue for malpositioned frozen elephant trunk into the false lumen","volume":"36","author":"Takagi","year":"2021","journal-title":"J Card Surg"},{"key":"R35-20260512","doi-asserted-by":"crossref","first-page":"738\u201343","DOI":"10.1177\/15266028221136452","article-title":"Emergency endovascular management of inadvertent false lumen stent graft implantation after frozen elephant trunk procedure: a case report","volume":"31","author":"Zhao","year":"2024","journal-title":"J Endovasc Ther"},{"key":"R36-20260512","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.1016\/j.athoracsur.2022.07.014","article-title":"Rescue of false lumen frozen elephant trunk deployment intraoperatively","volume":"116","author":"Witcher","year":"2023","journal-title":"Ann Thorac Surg"},{"key":"R37-20260512","doi-asserted-by":"crossref","first-page":"1523\u201325","DOI":"10.1016\/j.athoracsur.2006.02.002","article-title":"Iatrogenic type A dissection after attempted stenting of a descending aortic aneurysm","volume":"82","author":"Zhang","year":"2006","journal-title":"Ann Thorac Surg"},{"key":"R38-20260512","doi-asserted-by":"crossref","first-page":"1445\u201347","DOI":"10.1016\/j.athoracsur.2014.06.097","article-title":"Reverse frozen elephant trunk procedure for rescue of a thoracic stent-graft in the false lumen","volume":"99","author":"Isabella","year":"2015","journal-title":"Ann Thorac Surg"},{"key":"R39-20260512","doi-asserted-by":"crossref","first-page":"286\u201390","DOI":"10.1016\/j.ejcts.2005.02.046","article-title":"The frozen elephant trunk technique for the treatment of extensive thoracic aortic aneurysms: operative results and follow-up","volume":"28","author":"Karck","year":"2005","journal-title":"Eur J Cardiothorac Surg"},{"key":"R40-20260512","doi-asserted-by":"crossref","first-page":"597\u201399","DOI":"10.1510\/icvts.2009.223040","article-title":"Endovascular graft deployment in the false lumen of type B dissection","volume":"10","author":"Follis","year":"2010","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"R41-20260512","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1186\/s40792-017-0324-0","article-title":"Antegrade thoracic endovascular aortic repair using an ascending aortofemoral through-and-through wire technique for a severely tortuous aorta associated with rickets","volume":"3","author":"Morishita","year":"2017","journal-title":"Surg Case Rep"},{"key":"R42-20260512","doi-asserted-by":"crossref","first-page":"6380428","DOI":"10.1155\/2021\/6380428","article-title":"Antegrade hybrid chimney TEVAR endograft in a patient with blunt aortic injury: a challenging case with technical success but unfavorable result","volume":"2021","author":"Eforakopoulos","year":"2021","journal-title":"Case Reports in Vascular Medicine"},{"key":"R43-20260512","doi-asserted-by":"crossref","first-page":"135\u201341","DOI":"10.1007\/s11748-013-0299-0","article-title":"Elephant trunk technique for hybrid aortic arch repair","volume":"62","author":"Miyamoto","year":"2014","journal-title":"Gen Thorac Cardiovasc Surg"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000003028","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T12:06:48Z","timestamp":1778587608000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000003028"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,24]]},"references-count":43,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000003028","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,24]]},"assertion":[{"value":"2025-04-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}