{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T04:17:21Z","timestamp":1794975441839,"version":"4.9.1"},"reference-count":83,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,9,10]],"date-time":"2025-09-10T00:00:00Z","timestamp":1757462400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>This meta-analysis aimed to compare the perioperative safety and efficacy of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) in bicuspid aortic valve (BAV) stenosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>We systematically analyzed studies from PubMed, Cochrane Library, Embase, and CNKI comparing TAVR and SAVR in BAV stenosis. Outcomes included postoperative mortality, complications, all-cause survival, and freedom from stroke. Data were pooled using random-effects models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Fifteen studies (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 22 085; TAVR = 7840, SAVR = 14 245) were included. No significant difference regarding postoperative mortality between TAVR and SAVR in the whole patient cohort (odds ratio [OR]: 0.85, 95% confidence interval [CI]: 0.64\u20131.13;\n                      <jats:italic toggle=\"yes\">I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 16.13%) or adjusted patient cohort (OR: 0.85, 95% CI: 0.55\u20131.32;\n                      <jats:italic toggle=\"yes\">I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 40.28%) was observed. TAVR was associated with reduced risks of acute kidney injury (OR: 0.51, 95% CI: 0.35\u20130.75;\n                      <jats:italic toggle=\"yes\">I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 88.94%) and major bleeding (OR: 0.42, 95% CI: 0.21\u20130.84;\n                      <jats:italic toggle=\"yes\">I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 95.45%) but increased risks of permanent pacemaker implantation (OR: 2.47, 95% CI: 1.61\u20133.78;\n                      <jats:italic toggle=\"yes\">I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 86.48%) and paravalvular leak (OR: 4.39, 95% CI: 1.32\u201314.61;\n                      <jats:italic toggle=\"yes\">I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 72.93%). Landmark survival analysis demonstrated superior all-cause survival for SAVR beyond 6 months (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). In addition, patients with BAV stenosis receiving SAVR had better freedom from stroke (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). The certainty of evidence was low for several key outcomes due to study limitations.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>TAVR achieves comparable postoperative mortality to SAVR in BAV stenosis with fewer acute complications but inferior long-term survival and higher device-related risks. SAVR demonstrates durable survival benefits and enhanced stroke prevention, underscoring the need for individualized selection based on anatomy and life expectancy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000003377","type":"journal-article","created":{"date-parts":[[2025,9,10]],"date-time":"2025-09-10T14:01:52Z","timestamp":1757512912000},"page":"1763-1774","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of short- and long-term outcomes between transcatheter and surgical aortic valve replacement for bicuspid aortic valve stenosis: a systematic review and meta-analysis"],"prefix":"10.1097","volume":"112","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0844-4071","authenticated-orcid":false,"given":"Junning","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of Cardiovascular Remodeling and Dysfunction, Luzhou, Sichuan, PR China"},{"name":"Department of Cardiovascular Surgery, Beijing Anzhen Nanchong Hospital of Capital Medical University & Nanchong Central Hospital, The Second Clinical Medical College of North Sichuan Medical College, Nanchong, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Duoliang","family":"Wei","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Beijing Aortic Disease Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Clinical Medicine, North Sichuan Medical College, Nanchong, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Clinical Medicine, North Sichuan Medical College, Nanchong, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiao","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Clinical Medicine, North Sichuan Medical College, Nanchong, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenqian","family":"Lei","sequence":"additional","affiliation":[{"name":"Department of Oncology, Hejiang People\u2019s Hospital, Luzhou, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongjie","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Beijing Anzhen Nanchong Hospital of Capital Medical University & Nanchong Central Hospital, The Second Clinical Medical College of North Sichuan Medical College, Nanchong, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiqiang","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Beijing Anzhen Nanchong Hospital of Capital Medical University & Nanchong Central Hospital, The Second Clinical Medical College of North Sichuan Medical College, Nanchong, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peidong","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Beijing Anzhen Nanchong Hospital of Capital Medical University & Nanchong Central Hospital, The Second Clinical Medical College of North Sichuan Medical College, Nanchong, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juyi","family":"Wan","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of Cardiovascular Remodeling and Dysfunction, Luzhou, Sichuan, PR China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,9,10]]},"reference":[{"key":"R1-20260518","doi-asserted-by":"crossref","first-page":"1890\u2013900","DOI":"10.1016\/S0735-1097(02)01886-7","article-title":"The incidence of congenital heart disease","volume":"39","author":"Hoffman","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"R2-20260518","doi-asserted-by":"crossref","first-page":"513\u201315","DOI":"10.1016\/j.ahj.2004.10.036","article-title":"The prevalence of bicuspid aortic valve in newborns by echocardiographic screening","volume":"150","author":"Tutar","year":"2005","journal-title":"Am Heart J"},{"key":"R3-20260518","doi-asserted-by":"crossref","first-page":"6002","DOI":"10.3390\/jcm11206002","article-title":"Patients with bicuspid aortopathy and aortic dilatation","volume":"11","author":"Nappi","year":"2022","journal-title":"J Clin Med"},{"key":"R4-20260518","doi-asserted-by":"crossref","first-page":"798949","DOI":"10.3389\/fcvm.2021.798949","article-title":"Bicuspid aortic valve stenosis: from pathophysiological mechanism, imaging diagnosis, to clinical treatment methods","volume":"8","author":"Perrin","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"R5-20260518","doi-asserted-by":"crossref","first-page":"33\u201341","DOI":"10.1007\/s11886-021-01617-w","article-title":"Treatment of bicuspid aortic valve stenosis with TAVR: filling knowledge gaps towards reducing complications","volume":"24","author":"Yeats","year":"2022","journal-title":"Curr Cardiol Rep"},{"key":"R6-20260518","doi-asserted-by":"crossref","first-page":"617\u201322","DOI":"10.1093\/icvts\/ivx396","article-title":"The impact of coronary anomalies on the outcome in aortic valve surgery: comparison of bicuspid aortic valve versus tricuspid aortic valve morphotype","volume":"26","author":"Naito","year":"2018","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"R7-20260518","doi-asserted-by":"crossref","first-page":"1949\u201360","DOI":"10.1056\/NEJMoa2307447","article-title":"Transcatheter aortic-valve replacement in low-risk patients at five years","volume":"389","author":"Mack","year":"2023","journal-title":"N Engl J Med"},{"key":"R8-20260518","doi-asserted-by":"crossref","first-page":"1663\u201374","DOI":"10.1016\/j.jacc.2023.02.017","article-title":"3-Year outcomes after transcatheter or surgical aortic valve replacement in low-risk patients with aortic stenosis","volume":"81","author":"Forrest","year":"2023","journal-title":"J Am Coll Cardiol"},{"key":"R9-20260518","doi-asserted-by":"crossref","first-page":"2912\u201319","DOI":"10.1093\/eurheartj\/ehab375","article-title":"Eight-year outcomes for patients with aortic valve stenosis at low surgical risk randomized to transcatheter vs. surgical aortic valve replacement","volume":"42","author":"J\u00f8rgensen","year":"2021","journal-title":"Eur Heart J"},{"key":"R10-20260518","first-page":"1\u20136","article-title":"Transcatheter aortic valve replacement in low-risk bicuspid and tricuspid patients: meta-analysis","volume":"33","author":"Medranda","year":"2021","journal-title":"Cardiovasc Revasc Med"},{"key":"R11-20260518","first-page":"2144\u201355","article-title":"Outcomes after transcatheter aortic valve replacement in bicuspid versus tricuspid anatomy: a systematic review and meta-analysis","volume":"14","author":"Montalto","year":"2021","journal-title":"JACC: Cardiovasc Interv"},{"key":"R12-20260518","doi-asserted-by":"crossref","first-page":"105\u201312","DOI":"10.1016\/j.amjcard.2023.06.120","article-title":"Transcatheter aortic valve replacement in bicuspid versus tricuspid aortic valve stenosis: meta-analysis and systemic review","volume":"203","author":"Saeed Al-Asad","year":"2023","journal-title":"Am J Cardiol"},{"key":"R13-20260518","first-page":"100082","article-title":"Transparency in the reporting of artificial intelligence \u2013 the TITAN guideline","volume":"10","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R14-20260518","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"R15-20260518","doi-asserted-by":"crossref","first-page":"j4008","DOI":"10.1136\/bmj.j4008","article-title":"AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both","volume":"358","author":"Shea","year":"2017","journal-title":"BMJ"},{"key":"R16-20260518","article-title":"The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses","author":"Wells"},{"key":"R17-20260518","doi-asserted-by":"crossref","first-page":"d5928","DOI":"10.1136\/bmj.d5928","article-title":"The Cochrane collaboration\u2019s tool for assessing risk of bias in randomised trials","volume":"343","author":"Higgins","year":"2011","journal-title":"BMJ"},{"key":"R18-20260518","doi-asserted-by":"crossref","first-page":"401\u201306","DOI":"10.1016\/j.jclinepi.2010.07.015","article-title":"GRADE guidelines: 3. Rating the quality of evidence","volume":"64","author":"Balshem","year":"2011","journal-title":"J Clin Epidemiol"},{"key":"R19-20260518","doi-asserted-by":"crossref","first-page":"557\u201360","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses","volume":"327","author":"Higgins","year":"2003","journal-title":"BMJ"},{"key":"R20-20260518","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1186\/s12874-021-01308-8","article-title":"IPDfromKM: reconstruct individual patient data from published Kaplan-Meier survival curves","volume":"21","author":"Liu","year":"2021","journal-title":"BMC Med Res Methodol"},{"key":"R21-20260518","doi-asserted-by":"crossref","first-page":"515\u201326","DOI":"10.1093\/biomet\/81.3.515","article-title":"Proportional hazards tests and diagnostics based on weighted residuals","volume":"81","author":"Grambsch","year":"1994","journal-title":"Biometrika"},{"key":"R22-20260518","doi-asserted-by":"crossref","first-page":"2175\u201397","DOI":"10.1002\/sim.1203","article-title":"Flexible parametric proportional-hazards and proportional-odds models for censored survival data, with application to prognostic modelling and estimation of treatment effects","volume":"21","author":"Royston","year":"2002","journal-title":"Stat Med"},{"key":"R23-20260518","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1186\/1471-2288-13-152","article-title":"Restricted mean survival time: an alternative to the hazard ratio for the design and analysis of randomized trials with a time-to-event outcome","volume":"13","author":"Royston","year":"2013","journal-title":"BMC Med Res Methodol"},{"key":"R24-20260518","doi-asserted-by":"crossref","first-page":"611\u201318","DOI":"10.1016\/j.athoracsur.2022.06.030","article-title":"Transcatheter and surgical aortic valve replacement in patients with bicuspid aortic valve stenosis","volume":"115","author":"Sanaiha","year":"2023","journal-title":"Ann Thorac Surg"},{"key":"R25-20260518","doi-asserted-by":"crossref","first-page":"16\u201320","DOI":"10.1016\/j.carrev.2024.01.009","article-title":"Readmission-related outcomes of surgical versus transcatheter aortic valve replacement in patients aged 65 or older with bicuspid aortic valve","volume":"63","author":"Ogami","year":"2024","journal-title":"Cardiovasc Revasc Med"},{"key":"R26-20260518","doi-asserted-by":"crossref","first-page":"B361","DOI":"10.1016\/j.jacc.2024.09.1042","article-title":"TCT-134 surgical aortic valve implantation versus transcatheter aortic valve implantation in bicuspid aortic stenosis: a matched cohort","volume":"84","author":"Hemelrijk","year":"2024","journal-title":"J Am Coll Cardiol"},{"key":"R27-20260518","doi-asserted-by":"crossref","first-page":"B183","DOI":"10.1016\/j.jacc.2017.09.554","article-title":"Trends in trans-catheter aortic valve replacement in patients with bicuspid aortic valve stenosis: insights from national inpatient sample database","volume":"70","author":"Bhardwaj","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"R28-20260518","doi-asserted-by":"crossref","first-page":"3815\u201317","DOI":"10.1093\/eurheartj\/ehae537","article-title":"Transfemoral or surgical aortic valve replacement in young low-risk patients with tricuspid and bicuspid aortic valve stenosis","volume":"45","author":"Schofer","year":"2024","journal-title":"Eur Heart J"},{"key":"R29-20260518","first-page":"1811\u201322","article-title":"Temporal trends and outcomes of transcatheter versus surgical aortic valve replacement for bicuspid aortic valve stenosis","volume":"12","author":"Elbadawi","year":"2019","journal-title":"JACC: Cardiovasc Interv"},{"key":"R30-20260518","article-title":"Up to 7-year follow-up of bicuspid aortic valves (BAV) undergoing TAVI versus surgical aortic valve replacement (SAVR)","volume":"67","author":"Josic","year":"2019","journal-title":"Thorac Cardiovasc Surg"},{"key":"R31-20260518","doi-asserted-by":"crossref","first-page":"B421","DOI":"10.1016\/j.jacc.2019.08.517","article-title":"TCT-426 TAVR versus SAVR for bicuspid aortic valve","volume":"74","author":"Lisko","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"R32-20260518","article-title":"Surgical versus transcatheter aortic valve replacement for treatment of bicuspid aortic valve stenosis","volume":"68","author":"Fujita","year":"2020","journal-title":"Thorac Cardiovasc Surg"},{"key":"R33-20260518","doi-asserted-by":"crossref","first-page":"2518\u201319","DOI":"10.1016\/j.jacc.2020.02.069","article-title":"Transcatheter versus surgical aortic valve replacement in patients with bicuspid aortic valve stenosis","volume":"75","author":"Mentias","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"R34-20260518","first-page":"22\u201328","article-title":"Transcatheter aortic valve replacement in patients with bicuspid aortic valve stenosis: national trends and in-hospital outcomes","volume":"10","author":"Soud","year":"2020","journal-title":"Avicenna J Med"},{"key":"R35-20260518","doi-asserted-by":"crossref","first-page":"429\u201339","DOI":"10.1007\/s00392-020-01761-3","article-title":"Transcatheter and surgical aortic valve replacement in patients with bicuspid aortic valve","volume":"110","author":"Husso","year":"2021","journal-title":"Clin Res Cardiol"},{"key":"R36-20260518","doi-asserted-by":"crossref","first-page":"828\u201333","DOI":"10.1111\/jocs.15304","article-title":"Major adverse cardiac events and functional capacity in patients at intermediate risk undergoing transcatheter versus surgical aortic valve replacement for aortic stenosis with bicuspid valves","volume":"36","author":"Tsai","year":"2021","journal-title":"J Card Surg"},{"key":"R37-20260518","first-page":"1002\u201307","article-title":"Progression of ascending aortic dilatation and adverse aortic events after transcatheter aortic valve replacement in patients with bicuspid aortic valve comparison with surgical aortic valve replacement","volume":"37","author":"An","year":"2022","journal-title":"Chin Circ J"},{"key":"R38-20260518","doi-asserted-by":"crossref","first-page":"23\u201332","DOI":"10.4244\/EIJ-D-21-00757","article-title":"Early outcomes of transcatheter versus surgical aortic valve implantation in patients with bicuspid aortic valve stenosis","volume":"18","author":"Majmundar","year":"2022","journal-title":"EuroIntervention"},{"key":"R39-20260518","first-page":"978\u201383","article-title":"Long-term prognosis of elderly patients with bicuspid and tricuspid aortic valve stenosis","volume":"21","author":"Li","year":"2023","journal-title":"Chin J Integr Med Cardio Cerebrovasc Dis"},{"key":"R40-20260518","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1016\/j.jtcvs.2023.12.002","article-title":"Bicuspid aortic stenosis: national three-year outcomes of transcatheter versus surgical aortic valve replacement among medicare beneficiaries","volume":"168","author":"Chen","year":"2024","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R41-20260518","first-page":"ivae100","article-title":"Progression of the ascending aorta diameter after surgical or transcatheter bicuspid aortic valve replacement","volume":"38","author":"Chiariello","year":"2024","journal-title":"Interdiscip Cardiovasc Thorac Surg"},{"key":"R42-20260518","doi-asserted-by":"crossref","first-page":"3804\u201314","DOI":"10.1093\/eurheartj\/ehae331","article-title":"Transcatheter aortic valve implantation in low-risk tricuspid or bicuspid aortic stenosis: the NOTION-2 trial","volume":"45","author":"J\u00f8rgensen","year":"2024","journal-title":"Eur Heart J"},{"key":"R43-20260518","doi-asserted-by":"crossref","first-page":"1261\u201369","DOI":"10.1016\/j.athoracsur.2024.11.023","article-title":"Transcatheter vs surgical aortic valve replacement in bicuspid aortic valves","volume":"119","author":"Mehaffey","year":"2025","journal-title":"Ann Thorac Surg"},{"key":"R44-20260518","first-page":"3300\u201310","article-title":"Immediate and late outcomes of transcatheter aortic valve implantation versus surgical aortic valve replacement in bicuspid valves: meta-analysis of reconstructed time-to-event data","volume":"37","author":"S\u00e1","year":"2022","journal-title":"J Card Surg"},{"key":"R45-20260518","doi-asserted-by":"crossref","first-page":"75\u201394","DOI":"10.1016\/j.xjon.2022.11.012","article-title":"Transcatheter versus surgical aortic valve replacement for stenotic bicuspid aortic valve: systematic review and meta-analysis","volume":"13","author":"Sakurai","year":"2023","journal-title":"JTCVS Open"},{"key":"R46-20260518","first-page":"007","article-title":"Transcatheter versus surgical valve replacement in patients with bicuspid aortic valves: an updated meta-analysis","volume":"31","author":"Giannaris","year":"2024","journal-title":"Br J Cardiol"},{"key":"R47-20260518","doi-asserted-by":"crossref","first-page":"304\u201313","DOI":"10.1016\/j.tcm.2023.04.004","article-title":"Surgical vs transcatheter aortic valve replacement in bicuspid aortic valve stenosis: a systematic review and meta-analysis","volume":"34","author":"Kang","year":"2024","journal-title":"Trends Cardiovasc Med"},{"key":"R48-20260518","doi-asserted-by":"crossref","first-page":"196037","DOI":"10.1155\/2012\/196037","article-title":"Bicuspid aortic valve disease: a comprehensive review","volume":"2012","author":"Mordi","year":"2012","journal-title":"Cardiol Res Pract"},{"key":"R49-20260518","doi-asserted-by":"crossref","first-page":"1533\u201338","DOI":"10.1016\/j.amjcard.2016.08.021","article-title":"Comparison of quantity of calcific deposits by multidetector computed tomography in the aortic valve and coronary arteries","volume":"118","author":"van Rosendael","year":"2016","journal-title":"Am J Cardiol"},{"key":"R50-20260518","doi-asserted-by":"crossref","first-page":"1920\u201329","DOI":"10.1056\/NEJMra1207059","article-title":"Aortic dilatation in patients with bicuspid aortic valve","volume":"370","author":"Verma","year":"2014","journal-title":"N Engl J Med"},{"key":"R51-20260518","doi-asserted-by":"crossref","first-page":"143\u201347","DOI":"10.1053\/j.semtcvs.2005.02.005","article-title":"Management of the valve and ascending aorta in adults with bicuspid aortic valve disease","volume":"17","author":"Borger","year":"2005","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"R52-20260518","doi-asserted-by":"crossref","first-page":"2193\u2013202","DOI":"10.1001\/jama.2019.7108","article-title":"Association between transcatheter aortic valve replacement for bicuspid vs tricuspid aortic stenosis and mortality or stroke","volume":"321","author":"Makkar","year":"2019","journal-title":"Jama"},{"key":"R53-20260518","doi-asserted-by":"crossref","first-page":"1034\u201344","DOI":"10.1001\/jama.2021.13346","article-title":"Association between transcatheter aortic valve replacement for bicuspid vs tricuspid aortic stenosis and mortality or stroke among patients at low surgical risk","volume":"326","author":"Makkar","year":"2021","journal-title":"JAMA"},{"key":"R54-20260518","first-page":"511\u201322","article-title":"Propensity-matched 1-Year outcomes following transcatheter aortic valve replacement in low-risk bicuspid and tricuspid patients","volume":"15","author":"Deeb","year":"2022","journal-title":"JACC: Cardiovasc Interv"},{"key":"R55-20260518","doi-asserted-by":"crossref","first-page":"458\u201367","DOI":"10.1016\/j.tcm.2022.04.008","article-title":"Late outcomes of transcatheter aortic valve implantation in bicuspid versus tricuspid valves: meta-analysis of reconstructed time-to-event data","volume":"33","author":"S\u00e1","year":"2023","journal-title":"Trends Cardiovasc Med"},{"key":"R56-20260518","doi-asserted-by":"crossref","first-page":"836\u201352","DOI":"10.1093\/eurheartj\/ehac642","article-title":"Transcatheter versus surgical aortic valve replacement in lower-risk and higher-risk patients: a meta-analysis of randomized trials","volume":"44","author":"Ahmad","year":"2023","journal-title":"Eur Heart J"},{"key":"R57-20260518","first-page":"101458","article-title":"Short- and intermediate-term outcomes of transcatheter aortic valve replacement in low-risk patients: a meta-analysis and systematic review","volume":"53","author":"Rahman","year":"2024","journal-title":"Int J Cardiol Heart Vasc"},{"key":"R58-20260518","doi-asserted-by":"crossref","first-page":"e036179","DOI":"10.1161\/JAHA.124.036179","article-title":"Trends in transcatheter versus surgical aortic valve replacement outcomes in patients with low-surgical risk: a systematic review and meta-analysis of randomized trials","volume":"13","author":"Kazemian","year":"2024","journal-title":"J Am Heart Assoc"},{"key":"R59-20260518","doi-asserted-by":"crossref","first-page":"1706\u201315","DOI":"10.1056\/NEJMoa1816885","article-title":"Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients","volume":"380","author":"Popma","year":"2019","journal-title":"N Engl J Med"},{"key":"R60-20260518","doi-asserted-by":"crossref","first-page":"e26123","DOI":"10.1097\/MD.0000000000026123","article-title":"Pacemaker dependency after transcatheter aortic valve replacement compared to surgical aortic valve replacement","volume":"100","author":"Hwang","year":"2021","journal-title":"Medicine (Baltimore)"},{"key":"R61-20260518","doi-asserted-by":"crossref","first-page":"559\u201369","DOI":"10.1111\/pace.12104","article-title":"Transcatheter aortic valve implantation and requirements of pacing over time","volume":"36","author":"Pereira","year":"2013","journal-title":"Pacing Clin Electrophysiol"},{"key":"R62-20260518","doi-asserted-by":"crossref","first-page":"74\u201381","DOI":"10.1161\/CIRCINTERVENTIONS.108.780858","article-title":"Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve","volume":"1","author":"Piazza","year":"2008","journal-title":"Circ Cardiovasc Interv"},{"key":"R63-20260518","doi-asserted-by":"crossref","first-page":"309\u201322","DOI":"10.1080\/17434440.2020.1741349","article-title":"Can we reduce conduction disturbances following transcatheter aortic valve replacement?","volume":"17","author":"Alperi Garcia","year":"2020","journal-title":"Expert Rev Med Devices"},{"key":"R64-20260518","doi-asserted-by":"crossref","first-page":"288\u201398","DOI":"10.1161\/CIRCULATIONAHA.124.070753","article-title":"Conduction disturbances and outcome after surgical aortic valve replacement in patients with bicuspid and tricuspid aortic stenosis","volume":"151","author":"Wedin","year":"2025","journal-title":"Circulation"},{"key":"R65-20260518","doi-asserted-by":"crossref","first-page":"1043\u201361","DOI":"10.1161\/CIRCULATIONAHA.120.048048","article-title":"Transcatheter aortic valve replacement in bicuspid aortic valve stenosis","volume":"143","author":"Vincent","year":"2021","journal-title":"Circulation"},{"key":"R66-20260518","doi-asserted-by":"crossref","first-page":"339\u201347","DOI":"10.1016\/j.jcct.2020.10.002","article-title":"Short membranous septum length in bicuspid aortic valve stenosis increases the risk of conduction disturbances","volume":"15","author":"Hamdan","year":"2021","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R67-20260518","doi-asserted-by":"crossref","first-page":"91","DOI":"10.3389\/fcvm.2018.00091","article-title":"Transcatheter treatment of bicuspid aortic valve disease: imaging and interventional considerations","volume":"5","author":"Das","year":"2018","journal-title":"Front Cardiovasc Med"},{"key":"R68-20260518","doi-asserted-by":"crossref","first-page":"7371","DOI":"10.3390\/jcm12237371","article-title":"A meta-analysis of short-term outcomes of TAVR versus SAVR in bicuspid aortic valve stenosis and TAVR results in different bicuspid valve anatomies","volume":"12","author":"Improta","year":"2023","journal-title":"J Clin Med"},{"key":"R69-20260518","first-page":"1387","article-title":"Determinants of paravalvular leakage following transcatheter aortic valve replacement in patients with bicuspid and tricuspid aortic stenosis","volume":"22","author":"Kim","year":"2021","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"R70-20260518","doi-asserted-by":"crossref","first-page":"52\u201367","DOI":"10.1038\/s41569-022-00734-5","article-title":"Transcatheter aortic valve implantation in patients with bicuspid valve morphology: a roadmap towards standardization","volume":"20","author":"Xiong","year":"2023","journal-title":"Nat Rev Cardiol"},{"key":"R71-20260518","doi-asserted-by":"crossref","first-page":"1088681","DOI":"10.3389\/fphys.2022.1088681","article-title":"Aortic valve morphology and paravalvular leak regression after a self-expandable transcatheter aortic valve replacement","volume":"13","author":"Jin","year":"2022","journal-title":"Front Physiol"},{"key":"R72-20260518","doi-asserted-by":"crossref","first-page":"1252163","DOI":"10.3389\/fcvm.2023.1252163","article-title":"Results of new-generation balloon vs. self-expandable transcatheter heart valves for bicuspid aortic valve stenosis","volume":"10","author":"Deutsch","year":"2023","journal-title":"Front Cardiovasc Med"},{"key":"R73-20260518","first-page":"2649\u201359","article-title":"Global cost-effectiveness of transcatheter vs surgical aortic valve replacement in severe aortic stenosis: a systematic review and meta-analysis","volume":"40","author":"Zhou","year":"2024","journal-title":"Can J Cardiol"},{"key":"R74-20260518","doi-asserted-by":"crossref","first-page":"e010858","DOI":"10.1161\/CIRCOUTCOMES.124.010858","article-title":"Cost-effectiveness of aortic valve replacement in low- and intermediate-risk chinese patients with severe aortic stenosis","volume":"18","author":"Peng","year":"2025","journal-title":"Circ Cardiovasc Qual Outcomes"},{"key":"R75-20260518","doi-asserted-by":"crossref","first-page":"977\u201387","DOI":"10.1093\/ejcts\/ezab516","article-title":"Five-year outcomes in trials comparing transcatheter aortic valve implantation versus surgical aortic valve replacement: a pooled meta-analysis of reconstructed time-to-event data","volume":"61","author":"Barili","year":"2022","journal-title":"Eur J Cardiothorac Surg"},{"key":"R76-20260518","doi-asserted-by":"crossref","first-page":"e030012","DOI":"10.1161\/JAHA.123.030012","article-title":"Midterm survival of low-risk patients treated with transcatheter versus surgical aortic valve replacement: meta-analysis of reconstructed time-to-event data","volume":"12","author":"S\u00e1","year":"2023","journal-title":"J Am Heart Assoc"},{"key":"R77-20260518","doi-asserted-by":"crossref","first-page":"2383\u201392","DOI":"10.1016\/S0140-6736(17)30757-2","article-title":"Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study","volume":"389","author":"Chakravarty","year":"2017","journal-title":"Lancet"},{"key":"R78-20260518","first-page":"1565\u201374","article-title":"Postoperative atrial fibrillation or flutter following transcatheter or surgical aortic valve replacement: PARTNER 3 trial","volume":"14","author":"Shahim","year":"2021","journal-title":"JACC: Cardiovasc Interv"},{"key":"R79-20260518","doi-asserted-by":"crossref","first-page":"Ii291","DOI":"10.1161\/01.cir.0000087449.03964.fb","article-title":"Failure to prevent progressive dilation of ascending aorta by aortic valve replacement in patients with bicuspid aortic valve: comparison with tricuspid aortic valve","volume":"108","author":"Yasuda","year":"2003","journal-title":"Circulation"},{"key":"R80-20260518","doi-asserted-by":"crossref","first-page":"877\u201383","DOI":"10.1016\/j.amjcard.2012.04.064","article-title":"Feasibility and outcomes of transcatheter aortic valve implantation in high-risk patients with stenotic bicuspid aortic valves","volume":"110","author":"Himbert","year":"2012","journal-title":"Am J Cardiol"},{"key":"R81-20260518","doi-asserted-by":"crossref","first-page":"43\u201349","DOI":"10.1016\/j.athoracsur.2013.03.086","article-title":"Dilatation of the remaining aorta after aortic valve or aortic root replacement in patients with bicuspid aortic valve: a 5-year follow-up","volume":"96","author":"Abdulkareem","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"R82-20260518","doi-asserted-by":"crossref","first-page":"E234","DOI":"10.25270\/jic\/19.3108.E234","article-title":"Progression of the ascending aortic diameter after transcatheter aortic valve implantation: based on computed tomography images","volume":"31","author":"Lv","year":"2019","journal-title":"J Invasive Cardiol"},{"key":"R83-20260518","doi-asserted-by":"crossref","first-page":"332\u201341","DOI":"10.3904\/kjim.2019.089","article-title":"Progression of ascending aortopathy may not occur after transcatheter aortic valve replacement in severe bicuspid aortic stenosis","volume":"36","author":"Jung","year":"2021","journal-title":"Korean J Intern Med"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000003377","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T13:18:39Z","timestamp":1779110319000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000003377"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,10]]},"references-count":83,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000003377","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,10]]},"assertion":[{"value":"2025-04-23","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}