{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:41:40Z","timestamp":1787010100016,"version":"build-2736575974"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T00:00:00Z","timestamp":1763596800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The question of how to quickly and accurately identify and localize living parathyroid tissue, protect its functional integrity, and reduce the risk of intraoperative parathyroid function damage is a great challenge for clinicians and a technical challenge for researchers in the health care field.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective basic research designed a laser-induced fluorescence detection system that utilizes the intrinsic fluorescence of tissues and conducted a single-center clinical validation study from 28 May 2025 to 2 July 2025 which was registered with International Standard Randomised Controlled Trials Number (ISRCTN). The parathyroid gland (PG) detection data were obtained. A total of 106 patients aged between 18 and 99 representing different racial and gender backgrounds participated in this study. All the participating patients signed the informed consent form. This study mainly determines whether the tissue is a PG by measuring the fluorescence intensity values of the relevant human tissues during surgery under the laser-induced fluorescence detection system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The fluorescence detection module designed employs an innovative algorithm, which can effectively overcome the interference from complex environmental light sources such as shadowless surgical lights, thereby significantly improving the accuracy of fluorescence imaging of tissue contrast agents. System performance was evaluated using serial dilutions of indocyanine green to simulate PG autofluorescence, achieving a minimum detectable concentration of 8\u00a0\u00d7\u00a010\n                      <jats:sup>\u221210<\/jats:sup>\n                      mol\/L and a limit of detection of 1.24\u00a0\u00d7\u00a010\n                      <jats:sup>\u221210<\/jats:sup>\n                      mol\/L. The clinical verification of over 100 cases of\n                      <jats:italic toggle=\"yes\">in situ<\/jats:italic>\n                      PG detection showed that the detection accuracy rate was 98.3% (higher than 96% of the PTeye system and the naked eye recognition of clinicians, respectively), confirming its reliability in surgical environments.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>This PG detection system can accurately identify PGs, providing an effective solution for the real-time localization of intraoperative PG, which may improve intraoperative decision-making and patient prognosis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000004078","type":"journal-article","created":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T16:00:14Z","timestamp":1764172814000},"page":"6097-6106","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Real-time detection of parathyroid glands during surgery using a highly sensitive autofluorescence-based system"],"prefix":"10.1097","volume":"112","author":[{"given":"Jing","family":"Sun","sequence":"first","affiliation":[{"name":"Department of Biomaterials and Stem Cells, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hailiang","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Biomaterials and Stem Cells, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China"},{"name":"Laser Spectroscopy Detection Technology Laboratory, Jinan Guoke Medical Technology Development Co., Ltd., Jinan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Binghong","family":"Song","sequence":"additional","affiliation":[{"name":"Department of Biomaterials and Stem Cells, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China"},{"name":"Laser Spectroscopy Detection Technology Laboratory, Jinan Guoke Medical Technology Development Co., Ltd., Jinan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhongyi","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Biomaterials and Stem Cells, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China"},{"name":"Laser Spectroscopy Detection Technology Laboratory, Jinan Guoke Medical Technology Development Co., Ltd., Jinan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Longgang","family":"Yu","sequence":"additional","affiliation":[{"name":"Otolaryngology Head and Neck Surgery, Affiliated Hospital of Qingdao University, Qingdao, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baoyu","family":"Lv","sequence":"additional","affiliation":[{"name":"Shandong Provincial Key Medical and Health Laboratory of Major Chronic Disease Prevention and Treatment, The Third Affiliated Hospital of Shandong First Medical University, Jinan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Jiang","sequence":"additional","affiliation":[{"name":"Otolaryngology Head and Neck Surgery, Affiliated Hospital of Qingdao University, Qingdao, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenyu","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Biomaterials and Stem Cells, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,11,20]]},"reference":[{"key":"R1-20260417","first-page":"1531\u201344","article-title":"Thyroid cancer","volume":"401","author":"Chen","year":"2024","journal-title":"Lancet"},{"key":"R2-20260417","first-page":"359\u201386","article-title":"Cancer incidence and mortality worldwide: sources, methods and major patterns in GLOBOCAN 2012","volume":"136","author":"Ferlay","year":"2014","journal-title":"Int J Cancer"},{"key":"R3-20260417","doi-asserted-by":"crossref","first-page":"1687\u201395","DOI":"10.1002\/bjs.7219","article-title":"Outcome of protracted hypoparathyroidism after total thyroidectomy","volume":"97","author":"Sitges-Serra","year":"2010","journal-title":"Br J Surg"},{"key":"R4-20260417","doi-asserted-by":"crossref","first-page":"1517\u201331","DOI":"10.1089\/thy.2017.0716","article-title":"Developing a clinical prototype to guide surgeons for intraoperative label-free identification of parathyroid glands in real time","volume":"28","author":"Thomas","year":"2018","journal-title":"Thyroid"},{"key":"R5-20260417","first-page":"313\u201318","article-title":"Cost-benefit analysis of intraoperative autofluorescence for parathyroid identification","volume":"151","author":"Serrao-Brown","year":"2025","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R6-20260417","doi-asserted-by":"crossref","first-page":"480\u201386","DOI":"10.1016\/j.jss.2014.05.061","article-title":"Near infrared fluorescence imaging of rabbit thyroid and parathyroid glands","volume":"192","author":"Antakia","year":"2014","journal-title":"J Surg Res"},{"key":"R7-20260417","doi-asserted-by":"crossref","first-page":"067012\u2013067012","DOI":"10.1117\/1.3583571","article-title":"Near-infrared autofluorescence for the detection of parathyroid glands","volume":"16","author":"Paras","year":"2011","journal-title":"J Biomed Opt"},{"key":"R8-20260417","doi-asserted-by":"crossref","first-page":"744\u201351","DOI":"10.1016\/j.jamcollsurg.2018.12.044","article-title":"Randomized controlled trial comparing white light with near-infrared autofluorescence for parathyroid gland identification during total thyroidectomy","volume":"228","author":"Dip","year":"2019","journal-title":"J Am Coll Surg"},{"key":"R9-20260417","doi-asserted-by":"crossref","first-page":"165\u201372","DOI":"10.1016\/j.jamcollsurg.2017.10.015","article-title":"Near-infrared autofluorescence image-guided parathyroid gland mapping in thyroidectomy","volume":"226","author":"Kim","year":"2018","journal-title":"J Am Coll Surg"},{"key":"R10-20260417","doi-asserted-by":"crossref","first-page":"119\u201320","DOI":"10.1016\/j.jamcollsurg.2018.08.323","article-title":"Objective identification of parathyroid tissue using autofluorescence during thyroidectomy: a quantitative analysis","volume":"227","author":"Kose","year":"2018","journal-title":"J Am Coll Surg"},{"key":"R11-20260417","doi-asserted-by":"crossref","first-page":"979\u201385","DOI":"10.1001\/jamaoto.2024.3095","article-title":"Near-infrared autofluorescence signatures of single-vs multigland disease in primary hyperparathyroidism","volume":"150","author":"Akgun","year":"2024","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R12-20260417","doi-asserted-by":"crossref","first-page":"669\u201371","DOI":"10.1001\/jamaoto.2021.0615","article-title":"Use of near-infrared molecular imaging for localizing visually occult parathyroid glands in ectopic locations","volume":"147","author":"Kennedy","year":"2021","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R13-20260417","first-page":"249\u201356","article-title":"Complications after total thyroidectomy","volume":"150","author":"Ristou","year":"2013","journal-title":"J Visc Surg"},{"key":"R14-20260417","doi-asserted-by":"crossref","first-page":"142\u201346","DOI":"10.1097\/MOO.0000000000000346","article-title":"Hypoparathyroidism after thyroidectomy: prevention, assessment and management","volume":"25","author":"Dedivitis","year":"2017","journal-title":"Curr Opin Otolaryngol Head Neck Surg"},{"key":"R15-20260417","doi-asserted-by":"crossref","first-page":"1347\u201364","DOI":"10.1016\/S0140-6736(24)01614-3","article-title":"Hypothyroidism","volume":"404","author":"Taylor","year":"2024","journal-title":"Lancet"},{"key":"R16-20260417","doi-asserted-by":"crossref","first-page":"131879","DOI":"10.1016\/j.snb.2022.131879","article-title":"A highly sensitive optical fiber based near-infrared laser induced fluorescence detector (LIF) for parathyroid gland detection","volume":"364","author":"Duan","year":"2022","journal-title":"Sens Actuators B Chem"},{"key":"R17-20260417","doi-asserted-by":"crossref","first-page":"730\u201343","DOI":"10.1016\/j.jamcollsurg.2019.01.017","article-title":"Enhancing parathyroid gland visualization using a near infrared fluorescence-based overlay imaging system","volume":"228","author":"McWade","year":"2019","journal-title":"J Am Coll Surg"},{"key":"R18-20260417","doi-asserted-by":"crossref","first-page":"1506\u201312","DOI":"10.1007\/s00268-017-3903-0","article-title":"Intraoperative identification of the parathyroid gland with a fluorescence detection system","volume":"41","author":"Shinden","year":"2017","journal-title":"World J Surg"},{"key":"R19-20260417","doi-asserted-by":"crossref","first-page":"14798","DOI":"10.1038\/s41598-017-14941-5","article-title":"Intraoperative assessment of parathyroid viability using laser speckle contrast imaging","volume":"7","author":"Mannoh","year":"2017","journal-title":"Sci Rep"},{"key":"R20-20260417","first-page":"33\u201336","article-title":"Near-infrared autofluorescence imaging to detect parathyroid glands in thyroid surgery","volume":"100","author":"Ladurner","year":"2017","journal-title":"Ann R Coll Surg Engl"},{"key":"R21-20260417","doi-asserted-by":"crossref","first-page":"516","DOI":"10.21037\/gs.2017.05.08","article-title":"Intraoperative real-time localization of parathyroid gland with near infrared fluorescence imaging","volume":"6","author":"Kim","year":"2017","journal-title":"Gland Surg"},{"key":"R22-20260417","doi-asserted-by":"crossref","first-page":"173\u201379","DOI":"10.1016\/j.surg.2019.04.072","article-title":"Autofluorescence imaging of parathyroid glands: an assessment of potential indications","volume":"167","author":"Kose","year":"2020","journal-title":"Surgery"},{"key":"R23-20260417","first-page":"848\u201355","article-title":"The use of near-infrared fluorescence imaging in endocrine surgical procedures","volume":"115","author":"Kahramangil","year":"2019","journal-title":"J Surg Oncol"},{"key":"R24-20260417","doi-asserted-by":"crossref","first-page":"3737\u201342","DOI":"10.1007\/s00464-017-5424-1","article-title":"Increased identification of parathyroid glands using near infrared light during thyroid and parathyroid surgery","volume":"31","author":"Falco","year":"2017","journal-title":"Surg Endosc"},{"key":"R25-20260417","first-page":"4090\u201395","article-title":"Animal models for surgeries and implants: a vital tool in medical research and development","volume":"87","author":"Choudhary","year":"2025","journal-title":"Ann Med Surg (Lond)"},{"key":"R26-20260417","article-title":"Animal anatomical teaching models for enhanced veterinary anatomy education and learning","volume":"9","author":"Choudhary","year":"2025","journal-title":"Pak Vet J"},{"key":"R27-20260417","doi-asserted-by":"crossref","first-page":"973\u201379","DOI":"10.1002\/jso.26098","article-title":"The impact of near infrared fluorescence imaging on parathyroid function after total thyroidectomy","volume":"122","author":"Kim","year":"2020","journal-title":"J Surg Oncol"},{"key":"R28-20260417","doi-asserted-by":"crossref","first-page":"3827\u201338","DOI":"10.1097\/JS9.0000000000001247","article-title":"The impact of using near-infrared autofluorescence on parathyroid gland parameters and clinical outcomes during total thyroidectomy: a meta-analytic study of randomized controlled trials","volume":"110","author":"Safia","year":"2024","journal-title":"Int J Surg"},{"key":"R29-20260417","doi-asserted-by":"crossref","first-page":"1723\u201334","DOI":"10.1097\/JS9.0000000000000991","article-title":"Intraoperative strategies in identification and functional protection of parathyroid glands for patients with thyroidectomy: a systematic review and network meta-analysis","volume":"110","author":"Lu","year":"2024","journal-title":"Int J Surg"},{"key":"R30-20260417","doi-asserted-by":"crossref","first-page":"1\u20135","DOI":"10.1186\/s12893-019-0590-9","article-title":"Parathyroid identification by autofluorescence\u2013preliminary report on five cases of surgery for primary hyperparathyroidism","volume":"19","author":"Serra","year":"2019","journal-title":"BMC Surg"},{"key":"R31-20260417","first-page":"431\u201337","article-title":"Heterogeneous and low-intensity parathyroid autofluorescence: patterns suggesting hyperfunction at parathyroid exploration","volume":"165","author":"Kose","year":"2018","journal-title":"Surgery"},{"key":"R32-20260417","first-page":"100082","article-title":"Transparency in the reporting of Artificial INtelligence\u2013the TITAN guideline","volume":"10","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R33-20260417","first-page":"2451\u201360","article-title":"Comparative study of indocyanine green fluorescence imaging in lung cancer with near-infrared-I\/II windows","volume":"31","author":"Mi","year":"2023","journal-title":"Ann Surg Oncol"},{"key":"R34-20260417","doi-asserted-by":"crossref","first-page":"9168\u201319179","DOI":"10.1039\/D3NR03149G","article-title":"Biomimetic nanoplatform with selectively positioned indocyanine green for accurate sentinel lymph node imaging","volume":"15","author":"Cheng","year":"2023","journal-title":"Nanoscale"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000004078","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T11:00:13Z","timestamp":1776423613000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000004078"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,20]]},"references-count":34,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000004078","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,20]]},"assertion":[{"value":"2025-07-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}