{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T09:26:38Z","timestamp":1789550798100,"version":"build-2803163510"},"reference-count":59,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,12,16]],"date-time":"2025-12-16T00:00:00Z","timestamp":1765843200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Precise prenatal diagnosis of placenta accreta spectrum disorders (PAS) is challenging, and the diagnostic performance of conventional imaging modalities remains suboptimal. Artificial intelligence (AI) technologies have emerged as promising tools in assisting image analysis and improving diagnostic accuracy of PAS. Therefore, this study aims to systematically evaluate the diagnostic performance of AI models in diagnosing PAS and predicting adverse pregnancy outcomes (APO) associated with PAS.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A systematic search was conducted across multiple databases, including PubMed, Embase, and Cochrane Library, to identify studies assessing the diagnostic performance of AI-based models in PAS or their ability to predict APO. Diagnostic metrics such as sensitivity, specificity, area under the curve (AUC), positive likelihood ratio, negative likelihood ratio, and summary receiver operating characteristic (SROC) curves were pooled to evaluate diagnostic accuracy. Heterogeneity was assessed using Cochran\n                      <jats:italic toggle=\"yes\">Q<\/jats:italic>\n                      and\n                      <jats:italic toggle=\"yes\">I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      statistics, and meta-regression and subgroup analysis were conducted to examine potential sources of heterogeneity. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was utilized to assess the study quality.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 16 studies involving 4457 participants were included. The pooled results showed that AI models exhibit high sensitivity (88%, 95% CI: 81\u201393%) and specificity (88%, 95% CI: 76\u201394%) for diagnosing PAS, with an excellent AUC of 0.94 (95% CI: 0.91\u20130.96). Moreover, AI models also indicated promising performance in predicting clinically significant APO such as massive hemorrhage and hysterectomy, yielding a pooled sensitivity of 80% (95% CI: 73\u201385%), specificity of 86% (95% CI: 78\u201392%), and AUC of 0.87 (95% CI: 0.84\u20130.90). Meta-regression and subgroup analysis identified study design as a primary source of heterogeneity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>AI algorithms exhibited favorable performance for diagnosing PAS and predicting APO associated with PAS, suggesting the clinical translation potential of AI in enhancing the efficiency of diagnostic workflows and potentially reducing maternal morbidity and mortality.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000004443","type":"journal-article","created":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T15:00:15Z","timestamp":1765983615000},"page":"8478-8490","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Artificial intelligence (AI) in the diagnosis and prediction of adverse pregnancy outcomes for placenta accreta spectrum disorders (PAS): a systematic review and meta-analysis of diagnostic accuracy"],"prefix":"10.1097","volume":"112","author":[{"given":"Kai","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Obstetrics and Gynecology, Jinan City People\u2019s Hospital, People\u2019s Hospital Affiliated to Shandong First Medical University, Jinan, Shandong Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mei","family":"Xue","sequence":"additional","affiliation":[{"name":"Department of Obstetrics, Shandong Provincial Maternal and Child Health Care Hospital Affiliated to Qingdao University, Jinan, Shandong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianhua","family":"Meng","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Jinan City People\u2019s Hospital, People\u2019s Hospital Affiliated to Shandong First Medical University, Jinan, Shandong Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guifang","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Jinan City People\u2019s Hospital, People\u2019s Hospital Affiliated to Shandong First Medical University, Jinan, Shandong Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaohong","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Jinan City People\u2019s Hospital, People\u2019s Hospital Affiliated to Shandong First Medical University, Jinan, Shandong Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Long","sequence":"additional","affiliation":[{"name":"Medical Simulation Center & Department of Obstetrics, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi Zhuang Autonomous Region, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-2880-1344","authenticated-orcid":false,"given":"Hui","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Jinan City People\u2019s Hospital, People\u2019s Hospital Affiliated to Shandong First Medical University, Jinan, Shandong Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,12,16]]},"reference":[{"key":"R1-20260417","doi-asserted-by":"crossref","first-page":"20\u201324","DOI":"10.1002\/ijgo.12761","article-title":"FIGO classification for the clinical diagnosis of placenta accreta spectrum disorders","volume":"146","author":"Jauniaux","year":"2019","journal-title":"Int J Gynaecol Obstet"},{"key":"R2-20260417","doi-asserted-by":"crossref","first-page":"384\u201391","DOI":"10.1016\/j.ajog.2022.02.038","article-title":"New insights into the etiopathology of placenta accreta spectrum","volume":"227","author":"Jauniaux","year":"2022","journal-title":"Am J Obstet Gynecol"},{"key":"R3-20260417","doi-asserted-by":"crossref","first-page":"208\u201318","DOI":"10.1016\/j.ajog.2019.01.233","article-title":"Prevalence and main outcomes of placenta accreta spectrum: a systematic review and meta-analysis","volume":"221","author":"Jauniaux","year":"2019","journal-title":"Am J Obstet Gynecol"},{"key":"R4-20260417","doi-asserted-by":"crossref","first-page":"101329","DOI":"10.1016\/j.ajogmf.2024.101329","article-title":"First-trimester screening for placenta accreta spectrum","volume":"6","author":"Dar","year":"2024","journal-title":"Am J Obstet Gynecol MFM"},{"key":"R5-20260417","doi-asserted-by":"crossref","first-page":"1529\u201336","DOI":"10.1056\/NEJMcp1709324","article-title":"Placenta accreta spectrum","volume":"378","author":"Silver","year":"2018","journal-title":"N Engl J Med"},{"key":"R6-20260417","doi-asserted-by":"crossref","first-page":"193.e1\u2013.e9","DOI":"10.1016\/j.ajog.2018.04.049","article-title":"Placenta percreta is associated with more frequent severe maternal morbidity than placenta accreta","volume":"219","author":"Marcellin","year":"2018","journal-title":"Am J Obstet Gynecol"},{"key":"R7-20260417","doi-asserted-by":"crossref","first-page":"611\u201320","DOI":"10.1097\/AOG.0000000000005903","article-title":"Biology and pathophysiology of placenta accreta spectrum disorder","volume":"145","author":"Afshar","year":"2025","journal-title":"Obstet Gynecol"},{"key":"R8-20260417","doi-asserted-by":"crossref","first-page":"1167\u201376","DOI":"10.1097\/AOG.0000000000002865","article-title":"Association of implementing a multidisciplinary team approach in the management of morbidly adherent placenta with maternal morbidity and mortality","volume":"132","author":"Bartels","year":"2018","journal-title":"Obstet Gynecol"},{"key":"R9-20260417","first-page":"274\u201380","article-title":"FIGO consensus guidelines on placenta accreta spectrum disorders: prenatal diagnosis and screening","volume":"140","author":"Jauniaux","year":"2018","journal-title":"Int J Gynaecol Obstet"},{"key":"R10-20260417","doi-asserted-by":"crossref","first-page":"1348\u201355","DOI":"10.1111\/1471-0528.13547","article-title":"Abnormally invasive placenta-prevalence, risk factors and antenatal suspicion: results from a large population-based pregnancy cohort study in the Nordic countries","volume":"123","author":"Thurn","year":"2016","journal-title":"Bjog"},{"key":"R11-20260417","doi-asserted-by":"crossref","first-page":"2604\u201315","DOI":"10.1007\/s00330-019-06617-7","article-title":"Society of Abdominal Radiology (SAR) and European Society of Urogenital Radiology (ESUR) joint consensus statement for MR imaging of placenta accreta spectrum disorders","volume":"30","author":"Jha","year":"2020","journal-title":"Eur Radiol"},{"key":"R12-20260417","first-page":"290\u2013301","article-title":"Counseling in fetal medicine: evidence-based answers to clinical questions on morbidly adherent placenta","volume":"47","author":"D\u2019Antonio","year":"2016","journal-title":"Ultrasound Obstet Gynecol"},{"key":"R13-20260417","first-page":"13\u201324","article-title":"Antenatal diagnosis of placenta accreta spectrum (PAS) disorders","volume":"72","author":"Fny","year":"2021","journal-title":"Best Pract Res Clin Obstet Gynaecol"},{"key":"R14-20260417","doi-asserted-by":"crossref","first-page":"618.e1\u2013.e7","DOI":"10.1016\/j.ajog.2018.03.013","article-title":"Magnetic resonance imaging is often misleading when used as an adjunct to ultrasound in the management of placenta accreta spectrum disorders","volume":"218","author":"Einerson","year":"2018","journal-title":"Am J Obstet Gynecol"},{"key":"R15-20260417","doi-asserted-by":"crossref","first-page":"428\u201336","DOI":"10.1002\/uog.24861","article-title":"Diagnosis of placenta accreta spectrum in high-risk women using ultrasonography or magnetic resonance imaging: systematic review and meta-analysis","volume":"59","author":"De Oliveira Carniello","year":"2022","journal-title":"Ultrasound Obstet Gynecol"},{"key":"R16-20260417","doi-asserted-by":"crossref","first-page":"354\u201365","DOI":"10.2463\/mrms.rev.2024-0077","article-title":"Artificial Intelligence in obstetric and gynecological MR imaging","volume":"24","author":"Saida","year":"2025","journal-title":"Magn Reson Med Sci"},{"key":"R17-20260417","doi-asserted-by":"crossref","first-page":"233\u201343","DOI":"10.1097\/AOG.0000000000005944","article-title":"Current state of artificial intelligence model development in obstetrics","volume":"146","author":"Devoe","year":"2025","journal-title":"Obstet Gynecol"},{"key":"R18-20260417","doi-asserted-by":"crossref","first-page":"496\u2013509","DOI":"10.1002\/jmri.28787","article-title":"Prenatal diagnosis of placenta accreta spectrum disorders: deep learning radiomics of pelvic MRI","volume":"59","author":"Peng","year":"2024","journal-title":"J Magn Reson Imaging"},{"key":"R19-20260417","doi-asserted-by":"crossref","first-page":"107699","DOI":"10.1016\/j.cmpb.2023.107699","article-title":"Placental MRI segmentation based on multi-receptive field and mixed attention separation mechanism","volume":"242","author":"Lee","year":"2023","journal-title":"Comput Methods Programs Biomed"},{"key":"R20-20260417","first-page":"054001","article-title":"Deep learning-based segmentation of the placenta and uterus on MR images","volume":"8","author":"Shahedi","year":"2021","journal-title":"J Med Imaging (Bellingham)"},{"key":"R21-20260417","doi-asserted-by":"crossref","first-page":"2705\u201315","DOI":"10.1002\/jmri.29317","article-title":"Deep learning radiomic analysis of MRI combined with clinical characteristics diagnoses placenta accreta spectrum and its subtypes","volume":"60","author":"Zheng","year":"2024","journal-title":"J Magn Reson Imaging"},{"key":"R22-20260417","doi-asserted-by":"crossref","first-page":"1702\u201317","DOI":"10.1002\/jmri.26764","article-title":"MRI evaluation of the placenta from normal variants to abnormalities of implantation and malignancies","volume":"50","author":"Zaghal","year":"2019","journal-title":"J Magn Reson Imaging"},{"key":"R23-20260417","first-page":"324\u201332","article-title":"Barriers to artificial intelligence implementation in radiology practice: what the radiologist needs to know","volume":"64","author":"Nair","year":"2022","journal-title":"Radiologia (Engl Ed)"},{"key":"R24-20260417","doi-asserted-by":"crossref","first-page":"313\u201314","DOI":"10.1148\/radiol.2018180850","article-title":"Systematic reviews and meta-analyses of diagnostic test accuracy: the PRISMA-DTA statement","volume":"289","author":"Frank","year":"2018","journal-title":"Radiology"},{"key":"R25-20260417","doi-asserted-by":"crossref","first-page":"j4008","DOI":"10.1136\/bmj.j4008","article-title":"AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both","volume":"358","author":"Shea","year":"2017","journal-title":"BMJ"},{"key":"R26-20260417","doi-asserted-by":"crossref","first-page":"105906","DOI":"10.1016\/j.ijsu.2021.105906","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"88","author":"Page","year":"2021","journal-title":"Int J Surg"},{"key":"R27-20260417","first-page":"100082","article-title":"Transparency in the reporting of Artificial INtelligence \u2013 the TITAN guideline","volume":"10","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R28-20260417","doi-asserted-by":"crossref","first-page":"e233391","DOI":"10.1001\/jamanetworkopen.2023.3391","article-title":"Artificial Intelligence for hip fracture detection and outcome prediction: a systematic review and meta-analysis","volume":"6","author":"Lex","year":"2023","journal-title":"JAMA Network Open"},{"key":"R29-20260417","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1186\/s12880-024-01440-z","article-title":"Artificial intelligence in predicting recurrence after first-line treatment of liver cancer: a systematic review and meta-analysis","volume":"24","author":"Wu","year":"2024","journal-title":"BMC Med Imaging"},{"key":"R30-20260417","doi-asserted-by":"crossref","first-page":"529\u201336","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"key":"R31-20260417","doi-asserted-by":"crossref","first-page":"557\u201360","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses","volume":"327","author":"Higgins","year":"2003","journal-title":"BMJ"},{"key":"R32-20260417","doi-asserted-by":"crossref","first-page":"882\u201393","DOI":"10.1016\/j.jclinepi.2005.01.016","article-title":"The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed","volume":"58","author":"Deeks","year":"2005","journal-title":"J Clin Epidemiol"},{"key":"R33-20260417","doi-asserted-by":"crossref","first-page":"94\u2013103","DOI":"10.1148\/radiol.212530","article-title":"Contrast-enhanced mammography versus contrast-enhanced breast MRI: a systematic review and meta-analysis","volume":"305","author":"P\u00f6tsch","year":"2022","journal-title":"Radiology"},{"key":"R34-20260417","doi-asserted-by":"crossref","first-page":"71\u201376","DOI":"10.1016\/j.mri.2019.05.017","article-title":"Machine learning analysis of MRI-derived texture features to predict placenta accreta spectrum in patients with placenta previa","volume":"64","author":"Romeo","year":"2019","journal-title":"Magn Reson Imaging"},{"key":"R35-20260417","first-page":"281\u201392","article-title":"Machine learning for the prediction of surgical morbidity in placenta accreta spectrum","volume":"42","author":"Futterman","year":"2025","journal-title":"Am J Perinatol"},{"key":"R36-20260417","doi-asserted-by":"crossref","first-page":"424\u201331","DOI":"10.1002\/ijgo.13993","article-title":"Placenta accreta risk-antepartum score in predicting clinical outcomes of placenta accreta spectrum: a multicenter validation study","volume":"158","author":"Shazly","year":"2022","journal-title":"Int J Gynaecol Obstet"},{"key":"R37-20260417","doi-asserted-by":"crossref","first-page":"6644\u201353","DOI":"10.1080\/14767058.2021.1918670","article-title":"Prediction of clinical outcomes in women with placenta accreta spectrum using machine learning models: an international multicenter study","volume":"35","author":"Shazly","year":"2022","journal-title":"J Matern Fetal Neonatal Med"},{"key":"R38-20260417","doi-asserted-by":"crossref","first-page":"108757","DOI":"10.1016\/j.compbiomed.2024.108757","article-title":"Diagnosis of placenta accreta spectrum using ultrasound texture feature fusion and machine learning","volume":"178","author":"Young","year":"2024","journal-title":"Comput Biol Med"},{"key":"R39-20260417","doi-asserted-by":"crossref","first-page":"1833\u201342","DOI":"10.1093\/bjr\/tqae164","article-title":"Radiomic study of antenatal prediction of severe placenta accreta spectrum from MRI","volume":"97","author":"Bartels","year":"2024","journal-title":"Br J Radiol"},{"key":"R40-20260417","first-page":"492\u2013501","article-title":"Usefulness of decision tree analysis of MRI features for diagnosis of placenta accreta spectrum in cases with placenta previa","volume":"43","author":"Tanaka","year":"2025","journal-title":"Jpn J Radiol"},{"key":"R41-20260417","doi-asserted-by":"crossref","DOI":"10.1007\/s10278-025-01475-w","article-title":"Deep learning-assisted diagnosis of placenta accreta spectrum using the DenseNet-121 model: a multicenter, retrospective study","author":"Hu","year":"2025","journal-title":"J Imaging Inform Med"},{"key":"R42-20260417","first-page":"024502","article-title":"Ensemble of fine-tuned machine learning models for hysterectomy prediction in pregnant women using magnetic resonance images","volume":"12","author":"Reddy","year":"2025","journal-title":"J Med Imaging (Bellingham)"},{"key":"R43-20260417","doi-asserted-by":"crossref","first-page":"483\u201393","DOI":"10.1002\/jmri.28770","article-title":"A deep learning pipeline using prior knowledge for automatic evaluation of placenta accreta spectrum disorders with MRI","volume":"59","author":"Wang","year":"2024","journal-title":"J Magn Reson Imaging"},{"key":"R44-20260417","first-page":"3452176","article-title":"Deep learning algorithm-based ultrasound image information in diagnosis and treatment of pernicious placenta previa","volume":"2022","author":"Yang","year":"2022","journal-title":"Comput Math Methods Med"},{"key":"R45-20260417","doi-asserted-by":"crossref","first-page":"510\u201321","DOI":"10.1002\/jmri.29023","article-title":"Deep learning model based on multisequence MRI images for assessing adverse pregnancy outcome in placenta accreta","volume":"59","author":"Zong","year":"2024","journal-title":"J Magn Reson Imaging"},{"key":"R46-20260417","first-page":"120320N","article-title":"CascadeNet for hysterectomy prediction in pregnant women due to placenta accreta spectrum","volume":"12032","author":"Dormer","year":"2022","journal-title":"Proc SPIE Int Soc Opt Eng"},{"key":"R47-20260417","first-page":"4205\u201318","article-title":"Prediction of placenta accreta spectrum by combining deep learning and radiomics using T2WI: a multicenter study","volume":"47","author":"Ye","year":"2022","journal-title":"Abdom Radiol (NY)"},{"key":"R48-20260417","doi-asserted-by":"crossref","first-page":"2382\u201396","DOI":"10.1038\/s41379-020-0569-1","article-title":"Classification and reporting guidelines for the pathology diagnosis of placenta accreta spectrum (PAS) disorders: recommendations from an expert panel","volume":"33","author":"Hecht","year":"2020","journal-title":"Mod Pathol"},{"key":"R49-20260417","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1186\/s12884-023-05675-6","article-title":"Diagnostic accuracy of ultrasound in the diagnosis of Placenta accreta spectrum: systematic review and meta-analysis","volume":"23","author":"Maged","year":"2023","journal-title":"BMC Pregnancy Childbirth"},{"key":"R50-20260417","doi-asserted-by":"crossref","first-page":"112108","DOI":"10.1016\/j.ejrad.2025.112108","article-title":"Ultrasound versus magnetic resonance imaging features in diagnosing placenta accreta: a systematic review and meta-analysis","volume":"187","author":"Li","year":"2025","journal-title":"Eur J Radiol"},{"key":"R51-20260417","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1186\/s12884-024-07076-9","article-title":"Prenatal ultrasound scoring in diagnosis and postpartum outcomes prediction for Placenta Accreta Spectrum (PAS): a systematic review","volume":"24","author":"Peng","year":"2024","journal-title":"BMC Pregnancy Childbirth"},{"key":"R52-20260417","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1186\/s13244-022-01192-w","article-title":"Performance comparison of ultrasonography and magnetic resonance imaging in their diagnostic accuracy of placenta accreta spectrum disorders: a systematic review and meta-analysis","volume":"13","author":"Hong","year":"2022","journal-title":"Insights Imaging"},{"key":"R53-20260417","doi-asserted-by":"crossref","first-page":"e943461","DOI":"10.12659\/MSM.943461","article-title":"Accuracy of MRI-based radiomics in diagnosis of placenta accreta spectrum: a PRISMA systematic review and meta-analysis","volume":"30","author":"Huang","year":"2024","journal-title":"Med Sci Monit"},{"key":"R54-20260417","doi-asserted-by":"crossref","first-page":"1095\u2013110","DOI":"10.1016\/j.ccell.2022.09.012","article-title":"Artificial intelligence for multimodal data integration in oncology","volume":"40","author":"Lipkova","year":"2022","journal-title":"Cancer Cell"},{"key":"R55-20260417","first-page":"100362","article-title":"Machine learning applications in placenta accreta spectrum disorders","volume":"25","author":"Danaei","year":"2025","journal-title":"Eur J Obstet Gynecol Reprod Biol X"},{"key":"R56-20260417","doi-asserted-by":"crossref","first-page":"1805\u201311","DOI":"10.1007\/s00330-020-07230-9","article-title":"Applications of artificial intelligence (AI) in diagnostic radiology: a technography study","volume":"31","author":"Rezazade Mehrizi","year":"2021","journal-title":"Eur Radiol"},{"key":"R57-20260417","doi-asserted-by":"crossref","first-page":"879","DOI":"10.3390\/bioengineering12080879","article-title":"Beyond post hoc explanations: a comprehensive framework for accountable AI in medical imaging through transparency, interpretability, and explainability","volume":"12","author":"Singh","year":"2025","journal-title":"Bioengineering (Basel)"},{"key":"R58-20260417","doi-asserted-by":"crossref","first-page":"31892","DOI":"10.1038\/s41598-025-15867-z","article-title":"Personalized health monitoring using explainable AI: bridging trust in predictive healthcare","volume":"15","author":"Vani","year":"2025","journal-title":"Sci Rep"},{"key":"R59-20260417","doi-asserted-by":"crossref","first-page":"566\u201379","DOI":"10.1148\/radiol.213170","article-title":"Diagnostic accuracy of cardiac MRI versus FDG PET for cardiac sarcoidosis: a systematic review and meta-analysis","volume":"304","author":"Aitken","year":"2022","journal-title":"Radiology"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000004443","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T11:05:07Z","timestamp":1776423907000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000004443"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,16]]},"references-count":59,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000004443","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,16]]},"assertion":[{"value":"2025-09-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-25","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}