{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T14:58:49Z","timestamp":1793199529637,"version":"4.5.0"},"reference-count":41,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T00:00:00Z","timestamp":1771891200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Subtrochanteric femur fractures account for 40% of proximal femur fractures, and intramedullary nailing (IMN) is the treatment of choice, but there is a lack of uniformity in the selection of models. The challenge of individualized adaptation of diameter and length needs to be resolved, as too large or too small may lead to a lack of stability or increased surgical risk.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To establish a parametric selection model by analyzing the biomechanical properties of IMNs of different specifications to provide a basis for the clinical optimization of implantation strategies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Finite element analysis combined with\n                      <jats:italic toggle=\"yes\">in vitro<\/jats:italic>\n                      biomechanical experiments was used to construct a three-dimensional model based on femur CT data from healthy volunteers to assess the stress distribution and displacement characteristics of 15 sets of IMN (10\/11\/12 mm in diameter and 280\u2013360 mm in length); a Sawbone artificial bone was used to simulate the Seinsheimer II C fracture, and the strain under axial compression was tested, ultimate load and failure mode.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Result:<\/jats:title>\n                    <jats:p>The 12 mm diameter IMN performed optimally biomechanically, with lower displacement and stress peaks than the smaller diameter group, but may exacerbate the femoral neck stress masking effect. Nail length had no significant effect on stress. Re-fracture around the locking screws occurred in all groups at a load of 5 kN, suggesting a mechanically weak zone near the fracture line.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>For patients with Seinsheimer type IIC subtrochanteric femoral fractures who have good bone quality and a femoral neck anteversion angle \u226415\u00b0, this study proposes a personalized selection strategy using CT-based 3D reconstruction of the narrowest medullary cavity diameter, recommending an anatomically matched IMN (320 mm length) to optimize both mechanical stability and biological healing. The results provide important theoretical support for clinical precision treatment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000004568","type":"journal-article","created":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T13:00:23Z","timestamp":1766408423000},"page":"9310-9319","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Optimization strategies for intramedullary nailing parameters in subtrochanteric fractures of the femur: a multimodal assessment based on finite element and biomechanical experiments"],"prefix":"10.1097","volume":"112","author":[{"given":"Xiangyu","family":"Qi","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"},{"name":"Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiawen","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"},{"name":"Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qing","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"},{"name":"Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xu","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"},{"name":"Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yazhong","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongxiang","family":"Lv","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenbo","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-8732-5541","authenticated-orcid":false,"given":"Ziqiang","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The Second Affiliated Hospital of XuZhou Medical University, Xuzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,2,24]]},"reference":[{"key":"R1-20260424","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/s10195-022-00645-8","article-title":"Subtrochanteric femoral fractures and intramedullary nailing complications: a comparison of two implants","volume":"23","author":"Panteli","year":"2022","journal-title":"J Orthop Traumatol"},{"key":"R2-20260424","doi-asserted-by":"crossref","first-page":"145\u201351","DOI":"10.1302\/2058-5241.6.200048","article-title":"Subtrochanteric femur fractures: current review of management","volume":"6","author":"Garrison","year":"2021","journal-title":"EFORT Open Reviews"},{"key":"R3-20260424","doi-asserted-by":"crossref","first-page":"323\u201328","DOI":"10.1080\/17453674.2021.1878329","article-title":"Epidemiology and mortality of pelvic and femur fractures-a nationwide register study of 417,840 fractures in Sweden across 16 years: diverging trends for potentially lethal fractures","volume":"92","author":"Lundin","year":"2021","journal-title":"Acta Orthopaedica"},{"key":"R4-20260424","doi-asserted-by":"crossref","first-page":"e944383","DOI":"10.12659\/MSM.944383","article-title":"Enhanced outcomes in femoral subtrochanteric fractures using long INTERTAN nails with titanium cable cerclage: a retrospective analysis","volume":"30","author":"Bei","year":"2024","journal-title":"Med Sci Monit"},{"key":"R5-20260424","doi-asserted-by":"crossref","first-page":"e32155","DOI":"10.1097\/MD.0000000000032155","article-title":"Occurrence and clinical outcome of lateral wall fractures in proximal femoral fractures whose fracture line runs from femoral basal neck to subtrochanteric area","volume":"101","author":"Suzuki","year":"2022","journal-title":"Medicine"},{"key":"R6-20260424","first-page":"389\u2013403","article-title":"Subtrochanteric femur fractures: pearls and pitfalls","volume":"72","author":"Ganta","year":"2023","journal-title":"Instructional Course Lectures"},{"key":"R7-20260424","doi-asserted-by":"crossref","first-page":"259\u201367","DOI":"10.55095\/achot2020\/039","article-title":"[Treatment of Subtrochanteric Fractures, Our Experience, Complications]","volume":"87","author":"Pavelka","year":"2020","journal-title":"Acta Chirurgiae Orthopaedicae Et Traumatologiae Cechoslovaca"},{"key":"R8-20260424","doi-asserted-by":"crossref","first-page":"4761\u201374","DOI":"10.1007\/s00068-022-02003-z","article-title":"The effect of cerclage wiring with intramedullary nail surgery in proximal femoral fracture: a systematic review and meta-analysis","volume":"48","author":"Kim","year":"2022","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R9-20260424","doi-asserted-by":"crossref","first-page":"106438","DOI":"10.1016\/j.clinbiomech.2025.106438","article-title":"Numerical Comparison of the Intramedullary Nail for the Fixation of Different Proximal Femoral Fractures. Clinical Biomechanics","volume":"122","author":"Chen","year":"2025","journal-title":"(Bristol, Avon)"},{"key":"R10-20260424","doi-asserted-by":"crossref","first-page":"2561\u201372","DOI":"10.1007\/s00402-024-05297-3","article-title":"Surgical management and outcomes following atypical subtrochanteric femoral fractures - results from a matched-pair analysis of the registry for geriatric trauma of the German trauma society","volume":"144","author":"Bliemel","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"key":"R11-20260424","first-page":"305\u201310","article-title":"Intramedullary nailing for irreducible spiral subtrochanteric fractures: a comparison of cerclage and non-cerclage wiring","volume":"27","author":"Guo","year":"2024","journal-title":"Chinese Journal of Traumatology = Zhonghua Chuang Shang Za Zhi"},{"key":"R12-20260424","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1186\/s13018-024-05079-y","article-title":"Initial construct stability of long cephalomedullary nails with superior locking for a complex trochanteric fracture model AO31A2.2- a biomechanical study","volume":"19","author":"Schulz","year":"2024","journal-title":"J Orthopaedic Surg Res"},{"key":"R13-20260424","doi-asserted-by":"crossref","first-page":"363\u201373","DOI":"10.4055\/cios23234","article-title":"What is the optimal nail length to treat osteoporotic subtrochanteric fractures? a finite element analysis","volume":"16","author":"Je","year":"2024","journal-title":"Clin Orthopedic Surg"},{"key":"R14-20260424","first-page":"101149","article-title":"The cost-effectiveness of a co-managed care model for elderly hip fracture patients in China: a modelling study","volume":"49","author":"Xu","year":"2024","journal-title":"Lancet Reg Health West Pac"},{"key":"R15-20260424","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1186\/s12891-022-05781-0","article-title":"Does nail size or difference between canal and nail diameter influence likelihood of union or time to union of femoral shaft fractures treated with intramedullary nailing? A retrospective cohort study","volume":"23","author":"Shih","year":"2022","journal-title":"BMC Musculoskeletal Disorders"},{"key":"R16-20260424","first-page":"100082","article-title":"Transparency in the reporting of Artificial Intelligence \u2013 the TITAN Guideline","volume":"2","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R17-20260424","doi-asserted-by":"crossref","first-page":"1437\u201345","DOI":"10.1016\/j.arth.2013.01.010","article-title":"Stemmed TKA in a femur with a total hip arthroplasty: is there a safe distance between the stem tips?","volume":"28","author":"Soenen","year":"2013","journal-title":"The Journal of Arthroplasty"},{"key":"R18-20260424","doi-asserted-by":"crossref","first-page":"106499","DOI":"10.1016\/j.cmpb.2021.106499","article-title":"Biomechanical analysis of femoral stems in hinged total knee arthroplasty in physiological and osteoporotic bone","volume":"213","author":"Bori","year":"2022","journal-title":"Computer Methods And Programs In Biomedicine"},{"key":"R19-20260424","doi-asserted-by":"crossref","first-page":"e0253862","DOI":"10.1371\/journal.pone.0253862","article-title":"Biomechanics of subtrochanteric fracture fixation using short cephalomedullary nails: a finite element analysis","volume":"16","author":"Kwak","year":"2021","journal-title":"PloS One"},{"key":"R20-20260424","doi-asserted-by":"crossref","first-page":"1116976","DOI":"10.3389\/fbioe.2023.1116976","article-title":"Biomechanical evaluation of two modified intramedullary fixation system for treating unstable femoral neck fractures: a finite element analysis","volume":"11","author":"Huang","year":"2023","journal-title":"Front Bioeng Biotechnol"},{"key":"R21-20260424","doi-asserted-by":"crossref","first-page":"1189\u2013209","DOI":"10.1007\/s00402-023-05138-9","article-title":"Extramedullary versus intramedullary fixation of unstable trochanteric femoral fractures (AO type 31-A2): a systematic review and meta-analysis","volume":"144","author":"Zeelenberg","year":"2024","journal-title":"Arch Orthop Trauma Surg"},{"key":"R22-20260424","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1007\/s00068-025-02850-6","article-title":"Predicting mechanical complications in proximal femoral nailing for elderly patients: a radiological scoring system based on a single-centre retrospective cohort with 586 cases","volume":"51","author":"Han\u00e7erli","year":"2025","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R23-20260424","doi-asserted-by":"crossref","first-page":"389\u201396","DOI":"10.2106\/JBJS.24.00404","article-title":"Cephalomedullary nailing for subtrochanteric and reverse-oblique femoral fractures: comparison of a single versus dual lag screw device","volume":"107","author":"Ablett","year":"2025","journal-title":"J Bone Joint Surg Am Vol"},{"key":"R24-20260424","first-page":"1355\u201361","article-title":"The history of intramedullary nailing","volume":"45","author":"Bekos","year":"2021","journal-title":"Nt Orthop"},{"key":"R25-20260424","doi-asserted-by":"crossref","first-page":"104230","DOI":"10.1016\/j.medengphy.2024.104230","article-title":"Long vs short intramedullary nails for reverse pertrochanteric fractures: a biomechanical study","volume":"131","author":"Udin","year":"2024","journal-title":"Med Eng Phys"},{"key":"R26-20260424","doi-asserted-by":"crossref","first-page":"403\u201316","DOI":"10.1007\/s11914-021-00690-y","article-title":"Finite element analysis of fracture fixation","volume":"19","author":"Lewis","year":"2021","journal-title":"Curr Osteoporosis Rep"},{"key":"R27-20260424","doi-asserted-by":"crossref","first-page":"163\u201387","DOI":"10.1007\/s10237-021-01525-6","article-title":"Multiscale modeling of cancellous bone considering full coupling of mechanical, electric and magnetic effects","volume":"21","author":"Blaszczyk","year":"2022","journal-title":"Biomech. Model. Mechanobiol"},{"key":"R28-20260424","doi-asserted-by":"crossref","first-page":"1022506","DOI":"10.3389\/fbioe.2022.1022506","article-title":"Cortical bone continuum damage mechanics constitutive model with stress triaxiality criterion to predict fracture initiation and pattern","volume":"10","author":"Cronin","year":"2022","journal-title":"Front Bioeng Biotechnol"},{"key":"R29-20260424","doi-asserted-by":"crossref","first-page":"27247","DOI":"10.1038\/s41598-024-78819-z","article-title":"Relationship between the microstructural energy release rate of cortical bone and age under compression condition","volume":"14","author":"Fan","year":"2024","journal-title":"Sci Rep"},{"key":"R30-20260424","doi-asserted-by":"crossref","first-page":"1493555","DOI":"10.3389\/fbioe.2025.1493555","article-title":"Computational evaluation of the biomechanical effects of position changes in the femoral neck system on Pauwels type III femoral neck fractures: an in silico study","volume":"13","author":"Zhang","year":"2025","journal-title":"Front Bioeng Biotechnol"},{"key":"R31-20260424","doi-asserted-by":"crossref","first-page":"2358\u201366","DOI":"10.1002\/jor.24401","article-title":"Parametric finite element analysis of intramedullary nail fixation of proximal femur fractures","volume":"37","author":"Tucker","year":"2019","journal-title":"J Orthop Res"},{"key":"R32-20260424","doi-asserted-by":"crossref","first-page":"969\u201382","DOI":"10.1039\/D0TB02423F","article-title":"Biodegradable intramedullary nail (BIN) with high-strength bioceramics for bone fracture","volume":"9","author":"Sun","year":"2021","journal-title":"J Mat Chem B"},{"key":"R33-20260424","doi-asserted-by":"crossref","first-page":"107078","DOI":"10.1016\/j.cmpb.2022.107078","article-title":"Improve biomechanical stability using intramedullary nails with femoral neck protection in femoral shaft fractures","volume":"225","author":"Yuan","year":"2022","journal-title":"Computer Methods And Programs In Biomedicine"},{"key":"R34-20260424","doi-asserted-by":"crossref","first-page":"29\u201356","DOI":"10.1007\/s10439-020-02600-2","article-title":"Surgical drill bit design and thermomechanical damage in bone drilling: a review","volume":"49","author":"Akhbar","year":"2021","journal-title":"Ann. Biomed. Eng"},{"key":"R35-20260424","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1186\/s12903-025-06860-z","article-title":"Comparative evaluation of intraosseous temperature and drilling time using four different drill designs in implant site preparation","volume":"25","author":"Gedik","year":"2025","journal-title":"BMC Oral Health"},{"key":"R36-20260424","doi-asserted-by":"crossref","first-page":"107361","DOI":"10.1016\/j.cmpb.2023.107361","article-title":"Thermomechanical damage in cortical bone caused by margins of surgical drill bit: a finite element analysis","volume":"231","author":"Akhbar","year":"2023","journal-title":"Computer methods and programs in biomedicine"},{"key":"R37-20260424","doi-asserted-by":"crossref","first-page":"e283","DOI":"10.1097\/BOT.0000000000002025","article-title":"Quantitative evaluation of embolic load in femoral and tibial shaft fractures treated with reamed intramedullary fixation","volume":"35","author":"Lee","year":"2021","journal-title":"J of Orthop Trauma"},{"key":"R38-20260424","doi-asserted-by":"crossref","first-page":"252\u201357","DOI":"10.1097\/BOT.0000000000001687","article-title":"Reamed versus unreamed intertrochanteric femur fractures, is it time?","volume":"34","author":"Pitts","year":"2020","journal-title":"J of Orthop Trauma"},{"key":"R39-20260424","doi-asserted-by":"crossref","first-page":"e151","DOI":"10.1097\/OI9.0000000000000151","article-title":"Extracorporeal measurement of femoral nail length in the treatment of trochanteric hip fractures: the \u201cbox\u201d technique","volume":"4","author":"Garg","year":"2021","journal-title":"OTA International: The Open Access Journal of Orthopaedic Trauma"},{"key":"R40-20260424","doi-asserted-by":"crossref","first-page":"455\u201361","DOI":"10.52628\/90.3.11997","article-title":"Reamed versus unreamed proximal femoral nailing for intertrochanteric fractures in geriatric patients. A retrospective case control study","volume":"90","author":"Kastanis","year":"2024","journal-title":"Acta Orthopaedica Belgica"},{"key":"R41-20260424","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1302\/0301-620X.102B3.BJJ-2019-0776.R3","article-title":"Short (175 mm) versus standard (220 mm) length intramedullary nail for trochanteric hip fractures: a randomized trial of 229 patients","volume":"102","author":"Parker","year":"2020","journal-title":"The Bone & Joint Journal"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/JS9.0000000000004568","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T17:48:03Z","timestamp":1786038483000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/JS9.0000000000004568"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,24]]},"references-count":41,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000004568","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,24]]},"assertion":[{"value":"2025-05-21","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-03","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}