{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T10:26:40Z","timestamp":1783592800022,"version":"3.55.0"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T00:00:00Z","timestamp":1773619200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To investigate the feasibility, efficacy, and safety of gastric surgery in experimental animals assisted by the domestic Kangduo Surgical Robot 2000 (SR2000).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Eight porcine models were prospectively enrolled between August and December 2023 at Harbin SAGEBOT Intelligent Medical Animal Experiment Center. Preoperative baseline characteristics, intraoperative physiological parameters, surgical procedure, and postoperative assessments and investigations were recorded to compare the feasibility, efficacy, and safety evaluation indexes of experimental animals in the perioperative period. The primary endpoint was surgical success rate. The secondary endpoints were operative workflow parameters, intraoperative blood loss, postoperative laboratory changes, perioperative adverse events, and surgeon workload assessed using the NASA-TLX instrument.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>In eight experimental pig models, the SR2000 successfully assisted in the completion of partial gastrectomy. All surgeries were completed according to plan, with no intermediate open or intraoperative complications, and the perioperative survival rate of animals was 100%. The mean operation time of partial gastrectomy was 76.75 min (range: 50\u2013105 min), and the positioning time was 6\u201317 min. Intraoperative bleeding was \u22645\u00a0ml in all the animals, and some animals showed elevated white blood cell counts and neutrophil counts (Neu) on the first day of the postoperative period. The liver and kidney function indexes (alanine aminotransferase, blood urea nitrogen, creatinine) were not significantly abnormal before and after surgery. The anastomosis healed well without complications such as infection and anastomotic fistula.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The feasibility, efficacy, and safety of the SR2000 were verified in animal experiments, and ergonomically optimized design have the potential for clinical dissemination.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/js9.0000000000005035","type":"journal-article","created":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T13:01:30Z","timestamp":1774270890000},"page":"12679-12686","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Prospective single-arm study of gastric surgery in experimental animals assisted by Kangduo surgical robot"],"prefix":"10.1097","volume":"112","author":[{"given":"Songtao","family":"Yu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuliuming","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianyi","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianyu","family":"Qiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunxiao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunlin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenyang","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chenkai","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haonan","family":"Qi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuxuan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zijing","family":"Guan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bowen","family":"Chi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruoyu","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yinghu","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziming","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guiyu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,16]]},"reference":[{"key":"R1-20260709","doi-asserted-by":"crossref","first-page":"325\u201338","DOI":"10.1007\/s10120-023-01389-y","article-title":"Robotic gastrectomy for gastric cancer: systematic review and future directions","volume":"26","author":"Shibasaki","year":"2023","journal-title":"Gastric Cancer"},{"key":"R2-20260709","first-page":"e50415","article-title":"Advancements in robotic surgery: a comprehensive overview of current utilizations and upcoming frontiers","volume":"15","author":"Reddy","year":"2023","journal-title":"Cureus"},{"key":"R3-20260709","doi-asserted-by":"crossref","first-page":"14\u201321","DOI":"10.1097\/01.sla.0000103020.19595.7d","article-title":"Robotic surgery: a current perspective","volume":"239","author":"Lanfranco","year":"2004","journal-title":"Ann Surg"},{"key":"R4-20260709","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1186\/s12885-025-14395-3","article-title":"Short-term outcomes of robotic vs. laparoscopic surgery for gastric cancer after neoadjuvant therapy: a systematic review and meta-analysis","volume":"25","author":"Tuohuti","year":"2025","journal-title":"BMC Cancer"},{"key":"R5-20260709","doi-asserted-by":"crossref","first-page":"835\u201336","DOI":"10.1001\/jama.2018.9219","article-title":"Estimation of the acquisition and operating costs for robotic surgery","volume":"320","author":"Childers","year":"2018","journal-title":"Jama"},{"key":"R6-20260709","first-page":"133\u201340","article-title":"Robot-assisted partial nephrectomy with the newly developed kangduo surgical robot versus the da vinci si surgical system: a double-center prospective randomized controlled noninferiority trial","volume":"9","author":"Li","year":"2023","journal-title":"Eur Urol Focus"},{"key":"R7-20260709","doi-asserted-by":"crossref","first-page":"727\u201336","DOI":"10.1590\/s1677-5538.ibju.2024.0230","article-title":"Robot-assisted radical nephroureterectomy using the KangDuo Surgical Robot-01 System versus the da Vinci System: a multicenter prospective randomized controlled trial","volume":"50","author":"Zhang","year":"2024","journal-title":"Int Braz J Urol"},{"key":"R8-20260709","first-page":"1019\u201326","article-title":"Robot-assisted radical prostatectomy with the kangduo surgical system versus the da vinci si system: a prospective, double-center, randomized controlled trial","volume":"10","author":"Shen","year":"2024","journal-title":"Eur Urol Focus"},{"key":"R9-20260709","first-page":"2960\u201366","article-title":"Robotic urologic surgery using the KangDuo-Surgical Robot-01 system: a single-center prospective analysis","volume":"136","author":"Xiong","year":"2023","journal-title":"Chin Med J (Engl)"},{"key":"R10-20260709","doi-asserted-by":"crossref","first-page":"11739","DOI":"10.1038\/s41598-025-95382-3","article-title":"Short-term outcomes comparison of KangDuo 2.0 and Da Vinci Xi in radical cystectomy","volume":"15","author":"Feng","year":"2025","journal-title":"Sci Rep"},{"key":"R11-20260709","first-page":"4797\u2013805","article-title":"Role of 3DCT in laparoscopic total gastrectomy with spleen-preserving splenic lymph node dissection","volume":"20","author":"Wang","year":"2014","journal-title":"World J Gastroenterol"},{"key":"R12-20260709","first-page":"e49780","article-title":"The evolving surgical landscape: a comprehensive review of robotic versus laparoscopic gastrectomy for the treatment of gastric cancer","volume":"15","author":"Kossenas","year":"2023","journal-title":"Cureus"},{"key":"R13-20260709","doi-asserted-by":"crossref","first-page":"1140175","DOI":"10.3389\/fonc.2023.1140175","article-title":"Patient-specific virtual three-dimensional surgical navigation for gastric cancer surgery: a prospective study for preoperative planning and intraoperative guidance","volume":"13","author":"Park","year":"2023","journal-title":"Front Oncol"},{"key":"R14-20260709","doi-asserted-by":"crossref","first-page":"1158804","DOI":"10.3389\/fonc.2023.1158804","article-title":"Robotic versus laparoscopic gastrectomy for gastric cancer in patients with obesity: systematic review and meta-analysis","volume":"13","author":"Yu","year":"2023","journal-title":"Front Oncol"},{"key":"R15-20260709","doi-asserted-by":"crossref","first-page":"e1000412","DOI":"10.1371\/journal.pbio.1000412","article-title":"Improving bioscience research reporting: the ARRIVE guidelines for reporting animal research","volume":"8","author":"Kilkenny","year":"2010","journal-title":"PLoS Biol"},{"key":"R16-20260709","first-page":"100082","article-title":"Transparency in the Reporting of Artificial Intelligence \u2013 the TITAN Guideline","volume":"2","author":"Agha","year":"2025","journal-title":"Prem J Sci"},{"key":"R17-20260709","doi-asserted-by":"crossref","first-page":"2121\u201332","DOI":"10.1080\/00140139.2023.2186322","article-title":"Development and validation of a task load index for process control room operators (PCRO-TLX)","volume":"66","author":"Kazemi","year":"2023","journal-title":"Ergonomics"},{"key":"R18-20260709","doi-asserted-by":"crossref","first-page":"62\u201371","DOI":"10.1016\/j.soard.2023.08.007","article-title":"Robotic versus laparoscopic gastric bypass in bariatric surgery: a systematic review and meta-analysis on perioperative outcomes","volume":"20","author":"Leang","year":"2024","journal-title":"Surg Obes Relat Dis"},{"key":"R19-20260709","doi-asserted-by":"crossref","first-page":"1112473","DOI":"10.3389\/fsurg.2023.1112473","article-title":"Effects of different radical distal gastrectomy on postoperative inflammatory response and nutritional status in patients with gastric cancer","volume":"10","author":"Cheng","year":"2023","journal-title":"Front Surg"},{"key":"R20-20260709","doi-asserted-by":"crossref","first-page":"119\u201327","DOI":"10.1097\/JU.0000000000002498","article-title":"Robot-assisted radical prostatectomy using the kangduo surgical robot-01 system: a prospective, single-center, single-arm clinical study","volume":"208","author":"Fan","year":"2022","journal-title":"J Urol"},{"key":"R21-20260709","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s00345-025-05593-6","article-title":"Robot-assisted partial nephrectomy and robot-assisted radical prostatectomy using the Chinese surgical systems KangDuo-SR-2000 and EDGE MP1000 versus the Da Vinci Xi system: a prospective, single-center, non-randomized clinical trial","volume":"43","author":"Guo","year":"2025","journal-title":"World J Urol"},{"key":"R22-20260709","doi-asserted-by":"crossref","first-page":"759509","DOI":"10.3389\/fonc.2021.759509","article-title":"Comparison of long-term and perioperative outcomes of robotic versus conventional laparoscopic gastrectomy for gastric cancer: a systematic review and meta-analysis of PSM and RCT studies","volume":"11","author":"Feng","year":"2021","journal-title":"Front Oncol"},{"key":"R23-20260709","doi-asserted-by":"crossref","first-page":"3022\u201328","DOI":"10.1111\/ans.17830","article-title":"The National Aeronautics and Space Administration-task load index: NASA-TLX: evaluation of its use in surgery","volume":"92","author":"Bell","year":"2022","journal-title":"ANZ J Surg"},{"key":"R24-20260709","doi-asserted-by":"crossref","first-page":"1867\u201376","DOI":"10.1007\/s00464-024-10682-5","article-title":"Robot-assisted radical resection of colorectal cancer using the KangDuo surgical robot versus the da Vinci Xi robotic system: short-term outcomes of a multicentre randomised controlled noninferiority trial","volume":"38","author":"Sun","year":"2024","journal-title":"Surg Endosc"},{"key":"R25-20260709","doi-asserted-by":"crossref","first-page":"49\u201365","DOI":"10.1109\/RBME.2016.2538080","article-title":"Haptics in robot-assisted surgery: challenges and benefits","volume":"9","author":"Enayati","year":"2016","journal-title":"IEEE Rev Biomed Eng"},{"key":"R26-20260709","doi-asserted-by":"crossref","first-page":"19215","DOI":"10.1038\/s41598-023-46641-8","article-title":"The benefits of haptic feedback in robot assisted surgery and their moderators: a meta-analysis","volume":"13","author":"Bergholz","year":"2023","journal-title":"Sci Rep"},{"key":"R27-20260709","first-page":"1384\u201386","article-title":"Robotic-assisted radical colorectal cancer surgery with the KangDuo surgical robotic system vs. the da Vinci Xi surgical system in elderly patients: a multicenter randomized controlled trial","volume":"138","author":"Zhang","year":"2025","journal-title":"Chin Med J (Engl)"},{"key":"R28-20260709","doi-asserted-by":"crossref","first-page":"3493\u2013505","DOI":"10.1007\/s11695-024-07413-z","article-title":"Comparing the efficacy of robotic versus laparoscopic sleeve gastrectomy: a systematic review and meta-analysis","volume":"34","author":"Zhao","year":"2024","journal-title":"Obes Surg"},{"key":"R29-20260709","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s11701-024-01867-0","article-title":"Clinical applications of artificial intelligence in robotic surgery","volume":"18","author":"Knudsen","year":"2024","journal-title":"J Robot Surg"},{"key":"R30-20260709","doi-asserted-by":"crossref","first-page":"1393898","DOI":"10.3389\/fsurg.2024.1393898","article-title":"Current and future applications of artificial intelligence in surgery: implications for clinical practice and research","volume":"11","author":"Morris","year":"2024","journal-title":"Front Surg"}],"container-title":["International Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000005035","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T10:00:34Z","timestamp":1783591234000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/JS9.0000000000005035"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,16]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/js9.0000000000005035","relation":{},"ISSN":["1743-9159"],"issn-type":[{"value":"1743-9159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,16]]},"assertion":[{"value":"2025-10-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}