{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T00:48:04Z","timestamp":1794617284759,"version":"4.9.1"},"reference-count":53,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,12]]},"abstract":"<jats:p>The surgical management of rotator cuff (RC) tears has progressed considerably in recent decades. Arthroscopic procedures now represent the mainstay of contemporary treatment approaches. The success of repair is predicated upon the achievement of a secure, durable repair that promotes tendon-to-bone healing. Both single and double row (DR) suture anchor configurations have been described to achieve stable fixation. Although consensus is lacking with regard to the clinical superiority of one configuration over another, trends in the literature suggest that DR repairs may optimize the likelihood of tendon healing and restoration of shoulder strength. In cases of truly irreparable RC tears, superior capsular reconstruction is a promising alternative to open tendon transfer and arthroplasty procedures. The purposes of this concise review are to: (1) explain our preference for a DR repair configuration in almost all circumstances; and (2) advocate superior capsular reconstruction as a viable treatment tactic for truly irreparable RC tears in the absence of significant glenohumeral arthritis.<\/jats:p>","DOI":"10.1097\/jsa.0000000000000228","type":"journal-article","created":{"date-parts":[[2018,11,1]],"date-time":"2018-11-01T13:29:55Z","timestamp":1541078995000},"page":"171-175","source":"Crossref","is-referenced-by-count":11,"title":["Rotator Cuff Repair: Single Row Repair Versus Double Row Repair and Superior Capsular Reconstruction"],"prefix":"10.1097","volume":"26","author":[{"given":"Andrew J.","family":"Sheean","sequence":"first","affiliation":[{"name":"San Antonio Military Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert U.","family":"Hartzler","sequence":"additional","affiliation":[{"name":"The San Antonio Orthopaedic Group, Burkhart Research Institute for Orthopaedics (BRIO), San Antonio, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen S.","family":"Burkhart","sequence":"additional","affiliation":[{"name":"The San Antonio Orthopaedic Group, Burkhart Research Institute for Orthopaedics (BRIO), San Antonio, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20231002","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1302\/0301-620X.75B3.8496210","article-title":"Arthroscopic debridement versus open repair for rotator cuff tears. A prospective cohort study","volume":"75","author":"Ogilvie-Harris","year":"1993","journal-title":"J Bone Joint Surg Br"},{"key":"R2-20231002","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/1058-2746(93)90001-W","article-title":"Ten-year assessment of primary rotator cuff repairs","volume":"2","author":"Adamson","year":"1993","journal-title":"J Shoulder Elbow Surg"},{"key":"R3-20231002","doi-asserted-by":"crossref","first-page":"639","DOI":"10.2106\/00004623-198870050-00001","article-title":"Shoulder arthroscopy","volume":"70","author":"Rockwood","year":"1988","journal-title":"J Bone Joint Surg Am"},{"key":"R4-20231002","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/S0749-8063(05)80496-7","article-title":"The rotator crescent and rotator cable: an anatomic description of the shoulder\u2019s \u201csuspension bridge\u201d","volume":"9","author":"Burkhart","year":"1993","journal-title":"Arthroscopy"},{"key":"R5-20231002","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/00003086-199211000-00018","article-title":"Fluoroscopic comparison of kinematic patterns in massive rotator cuff tears. A suspension bridge model","volume":"284","author":"Burkhart","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"R6-20231002","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/00003086-199106000-00006","article-title":"Arthroscopic treatment of massive rotator cuff tears. Clinical results and biomechanical rationale","volume":"267","author":"Burkhart","year":"1991","journal-title":"Clin Orthop Relat Res"},{"key":"R7-20231002","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0749-8063(91)90070-E","article-title":"Partial thickness rotator cuff tears: results of arthroscopic treatment","volume":"7","author":"Snyder","year":"1991","journal-title":"Arthroscopy"},{"key":"R8-20231002","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/0749-8063(90)90099-Y","article-title":"Arthroscopic assisted rotator cuff repair: preliminary results","volume":"6","author":"Levy","year":"1990","journal-title":"Arthroscopy"},{"key":"R9-20231002","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1177\/036354659302100621","article-title":"Pull-out strength of suture anchors for rotator cuff and Bankart lesion repairs","volume":"21","author":"Hecker","year":"1993","journal-title":"Am J Sports Med"},{"key":"R10-20231002","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/S0749-8063(05)80415-3","article-title":"A technique for arthroscopic mattress suture placement","volume":"9","author":"Thal","year":"1993","journal-title":"Arthroscopy"},{"key":"R11-20231002","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/S0030-5898(21)00046-8","article-title":"Evaluation and treatment of the rotator cuff","volume":"24","author":"Snyder","year":"1993","journal-title":"Orthop Clin North Am"},{"key":"R13-20231002","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.1016\/j.arthro.2017.10.027","article-title":"Comparison of short-term complications after rotator cuff repair: open versus arthroscopic","volume":"34","author":"Day","year":"2018","journal-title":"Arthroscopy"},{"key":"R14-20231002","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1111\/ans.14176","article-title":"Arthroscopic, open and mini-open approach for rotator cuff repair: no difference in pain or function at 24 months","volume":"88","author":"Bond","year":"2018","journal-title":"ANZ J Surg"},{"key":"R15-20231002","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1053\/jars.2002.32930","article-title":"Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area","volume":"18","author":"Apreleva","year":"2002","journal-title":"Arthroscopy"},{"key":"R16-20231002","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.jse.2006.03.004","article-title":"Rotator cuff repair: the effect of double-row fixation on three-dimensional repair site","volume":"15","author":"Meier","year":"2006","journal-title":"J Shoulder Elbow Surg"},{"key":"R17-20231002","doi-asserted-by":"crossref","first-page":"1861","DOI":"10.1177\/0363546505279575","article-title":"Arthroscopic single-row versus double-row suture anchor rotator cuff repair","volume":"33","author":"Mazzocca","year":"2005","journal-title":"Am J Sports Med"},{"key":"R18-20231002","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1177\/0363546505281238","article-title":"Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair","volume":"34","author":"Kim","year":"2006","journal-title":"Am J Sports Med"},{"key":"R19-20231002","first-page":"403","article-title":"Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation","volume":"88","author":"Ma","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R20-20231002","doi-asserted-by":"crossref","first-page":"1813","DOI":"10.1016\/j.jse.2014.03.008","article-title":"Does transosseous-equivalent rotator cuff repair biomechanically provide a \u201cself-reinforcement\u201d effect compared with single-row repair?","volume":"23","author":"Park","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"R21-20231002","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1016\/j.jse.2009.07.002","article-title":"Double-row vs single-row rotator cuff repair: a review of the biomechanical evidence","volume":"18","author":"Wall","year":"2009","journal-title":"J Shoulder Elbow Surg"},{"key":"R22-20231002","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.jse.2009.09.006","article-title":"In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions","volume":"19","author":"Grimberg","year":"2010","journal-title":"J Shoulder Elbow Surg"},{"key":"R23-20231002","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/j.jse.2006.09.010","article-title":"Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique","volume":"16","author":"Park","year":"2007","journal-title":"J Shoulder Elbow Surg"},{"key":"R24-20231002","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.jse.2006.09.011","article-title":"Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique","volume":"16","author":"Park","year":"2007","journal-title":"J Shoulder Elbow Surg"},{"key":"R25-20231002","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1177\/0363546515590596","article-title":"The optimum tension for bridging sutures in transosseous-equivalent rotator cuff repair: a cadaveric biomechanical study","volume":"43","author":"Park","year":"2015","journal-title":"Am J Sports Med"},{"key":"R26-20231002","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1016\/j.arthro.2008.09.024","article-title":"A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair","volume":"25","author":"Burkhart","year":"2009","journal-title":"Arthroscopy"},{"key":"R27-20231002","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/j.arthro.2010.02.007","article-title":"Bridging self-reinforcing double-row rotator cuff repair: we really are doing better","volume":"26","author":"Burkhart","year":"2010","journal-title":"Arthroscopy"},{"key":"R28-20231002","first-page":"E244","article-title":"Patient preference before and after arthroscopic rotator cuff repair: which is more important, pain relief or strength return?","volume":"46","author":"Virk","year":"2017","journal-title":"Am J Orthop"},{"key":"R29-20231002","doi-asserted-by":"crossref","first-page":"2325967117750104","DOI":"10.1177\/2325967117750104","article-title":"A comprehensive evaluation of factors affecting healing, range of motion, strength, and patient-reported outcomes after arthroscopic rotator cuff repair","volume":"6","author":"Wylie","year":"2018","journal-title":"Orthop J Sports Med"},{"key":"R30-20231002","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1007\/s11999-017-5251-7","article-title":"What influence does progression of a nonhealing rotator cuff tear have on shoulder pain and function?","volume":"475","author":"Jeon","year":"2017","journal-title":"Clin Orthop Relat Res"},{"key":"R31-20231002","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1177\/0363546516652900","article-title":"The clinical effect of a rotator cuff retear: a meta-analysis of arthroscopic single-row and double-row repairs","volume":"45","author":"Yang","year":"2017","journal-title":"Am J Sports Med"},{"key":"R32-20231002","doi-asserted-by":"crossref","first-page":"1176","DOI":"10.1177\/0363546511428866","article-title":"Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review","volume":"40","author":"DeHaan","year":"2012","journal-title":"Am J Sports Med"},{"key":"R33-20231002","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1016\/j.jse.2013.10.006","article-title":"Clinical and structural outcomes after arthroscopic single-row versus double-row rotator cuff repair: a systematic review and meta-analysis of level I randomized clinical trials","volume":"23","author":"Millett","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"R34-20231002","doi-asserted-by":"crossref","first-page":"732","DOI":"10.2106\/JBJS.I.01295","article-title":"Outcomes of single-row and double-row arthroscopic rotator cuff repair: a systematic review","volume":"92","author":"Saridakis","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R35-20231002","doi-asserted-by":"crossref","first-page":"e1006","DOI":"10.3928\/01477447-20141023-58","article-title":"Incidence of retear with double-row versus single-row rotator cuff repair","volume":"37","author":"Shen","year":"2014","journal-title":"Orthopedics"},{"key":"R36-20231002","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1016\/j.jse.2017.10.040","article-title":"Clinical and radiologic outcome of arthroscopic rotator cuff repair: single-row versus transosseous equivalent repair","volume":"27","author":"Jeong","year":"2018","journal-title":"J Shoulder Elbow Surg"},{"key":"R37-20231002","doi-asserted-by":"crossref","first-page":"2274","DOI":"10.1016\/j.arthro.2015.06.004","article-title":"Retear rates after arthroscopic single-row, double-row, and suture bridge rotator cuff repair at a minimum of 1 year of imaging follow-up: a systematic review","volume":"31","author":"Hein","year":"2015","journal-title":"Arthroscopy"},{"key":"R38-20231002","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.1016\/j.arthro.2013.03.076","article-title":"Outcomes of single-row versus double-row arthroscopic rotator cuff repair: a systematic review and meta-analysis of current evidence","volume":"29","author":"Chen","year":"2013","journal-title":"Arthroscopy"},{"key":"R39-20231002","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.1016\/j.arthro.2017.11.015","article-title":"Factors affecting cost, outcomes, and tendon healing after arthroscopic rotator cuff repair","volume":"34","author":"Chalmers","year":"2018","journal-title":"Arthroscopy"},{"key":"R40-20231002","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.2106\/JBJS.16.01044","article-title":"Double-row arthroscopic rotator cuff repair is more cost-effective than single-row repair","volume":"99","author":"Huang","year":"2017","journal-title":"J Bone Joint Surg Am"},{"key":"R41-20231002","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1016\/j.arthro.2011.12.007","article-title":"Long-term outcome of arthroscopic massive rotator cuff repair: the importance of double-row fixation","volume":"28","author":"Denard","year":"2012","journal-title":"Arthroscopy"},{"key":"R42-20231002","doi-asserted-by":"crossref","first-page":"e37","DOI":"10.1016\/j.eats.2011.12.005","article-title":"A load-sharing rip-stop fixation construct for arthroscopic rotator cuff repair","volume":"1","author":"Denard","year":"2012","journal-title":"Arthrosc Tech"},{"key":"R43-20231002","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1177\/0363546513516602","article-title":"Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears","volume":"42","author":"Burkhart","year":"2014","journal-title":"Am J Sports Med"},{"key":"R44-20231002","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/j.arthro.2017.09.046","article-title":"Preoperative radiographic risk factors for incomplete arthroscopic supraspinatus tendon repair in massive rotator cuff tears","volume":"34","author":"Sheean","year":"2018","journal-title":"Arthroscopy"},{"key":"R45-20231002","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1016\/j.arthro.2017.04.003","article-title":"Functional outcome and healing of large and massive rotator cuff tears repaired with a load-sharing rip-stop construct","volume":"33","author":"Noyes","year":"2017","journal-title":"Arthroscopy"},{"key":"R46-20231002","doi-asserted-by":"crossref","first-page":"271","DOI":"10.3928\/01477447-20170920-02","article-title":"Superior capsular reconstruction","volume":"40","author":"Hartzler","year":"2017","journal-title":"Orthopedics"},{"key":"R47-20231002","doi-asserted-by":"crossref","first-page":"2628","DOI":"10.1016\/j.arthro.2016.08.011","article-title":"The rotator cuff and the superior capsule: why we need both","volume":"32","author":"Adams","year":"2016","journal-title":"Arthroscopy"},{"key":"R48-20231002","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1016\/j.jse.2011.04.034","article-title":"The superior capsule of the shoulder joint complements the insertion of the rotator cuff","volume":"21","author":"Nimura","year":"2012","journal-title":"J Shoulder Elbow Surg"},{"key":"R49-20231002","doi-asserted-by":"crossref","first-page":"962","DOI":"10.2106\/JBJS.G.00427","article-title":"Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff","volume":"90","author":"Mochizuki","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"R50-20231002","doi-asserted-by":"crossref","first-page":"2248","DOI":"10.1177\/0363546512456195","article-title":"Superior capsule reconstruction to restore superior stability in irreparable rotator cuff tears: a biomechanical cadaveric study","volume":"40","author":"Mihata","year":"2012","journal-title":"Am J Sports Med"},{"key":"R51-20231002","first-page":"320","article-title":"The arthroscopic superior capsular reconstruction","volume":"45","author":"Adams","year":"2016","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"R52-20231002","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.arthro.2017.08.265","article-title":"Preliminary results of arthroscopic superior capsule reconstruction with dermal allograft","volume":"34","author":"Denard","year":"2018","journal-title":"Arthroscopy"},{"key":"R53-20231002","doi-asserted-by":"crossref","first-page":"1764","DOI":"10.1016\/j.arthro.2018.01.009","article-title":"Arthroscopic superior capsular reconstruction for the treatment of massive irreparable rotator cuff tears in the active patient: 1-2 year results","volume":"34","author":"Pennington","year":"2018","journal-title":"Arthroscopy"},{"key":"R54-20231002","doi-asserted-by":"crossref","first-page":"e3","DOI":"10.1016\/j.arthro.2017.04.030","article-title":"Arthroscopic superior capsule reconstruction (ASCR) vs. latissimus dorsi transfer (LDT): a comparison of early clinical outcomes","volume":"33","author":"Millett","year":"2017","journal-title":"Arthroscopyy"}],"container-title":["Sports Medicine and Arthroscopy Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00132585-201812000-00009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T20:47:25Z","timestamp":1696279645000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00132585-201812000-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12]]},"references-count":53,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/jsa.0000000000000228","relation":{},"ISSN":["1062-8592"],"issn-type":[{"value":"1062-8592","type":"print"}],"subject":[],"published":{"date-parts":[[2018,12]]}}}