{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T14:51:15Z","timestamp":1787064675648,"version":"build-2736575974"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The 2016 CHEST consensus guidelines recommend use of either 21- or 22-G needles for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). We decided to prospectively compare sample adequacy and diagnostic yield of the 19-G with the 22-G EBUS needle, hypothesizing that a larger gauge difference might magnify the differences between 2 needle sizes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Twenty-seven patients undergoing EBUS-TBNA at our institution were evaluated. All cases were performed by a single operator formally trained in interventional pulmonology. Both Olympus 19- and 22-G needles were used at each lymph node station in an alternating manner. Rapid on-site cytology evaluation was used and a separate cell block was prepared for each needle at each station.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Fifty-six lymph nodes were analyzed. Diagnoses included cancer (36%, including 1 lymphoma), reactive lymphoid tissue (53%), and sarcoidosis (11%). One hundred sixty-two and 163 passes were made with the 22- and 19-G needle, respectively. Sample adequacy was 73% and 46% with the 22 and 19-G needle, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). Significantly fewer passes were bloody with the 22-G compared with the 19-G needle (19% vs. 59%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). Diagnostic yield was not different between the 22- and 19-G needles (95% vs. 93%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.62).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>In addition to no difference in diagnostic yield, the 19-G needle yielded samples that were frequently less adequate and more often bloody compared with the 22-G needle. Despite the larger caliber lumen, we conclude that the 19-G needle does not confer a diagnostic advantage.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/lbr.0000000000000515","type":"journal-article","created":{"date-parts":[[2018,5,16]],"date-time":"2018-05-16T21:08:04Z","timestamp":1526504884000},"page":"264-268","source":"Crossref","is-referenced-by-count":39,"title":["Comparison of Sample Adequacy and Diagnostic Yield of 19- and 22-G EBUS-TBNA Needles"],"prefix":"10.1097","volume":"25","author":[{"given":"Udit","family":"Chaddha","sequence":"first","affiliation":[{"name":"Division of Pulmonary, Critical Care and Sleep Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reza","family":"Ronaghi","sequence":"additional","affiliation":[{"name":"Division of Pulmonary, Critical Care and Sleep Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Waafa","family":"Elatre","sequence":"additional","affiliation":[{"name":"Department of Pathology, Keck School of Medicine of the University of Southern California, Los Angeles, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ching-Fei","family":"Chang","sequence":"additional","affiliation":[{"name":"Division of Pulmonary, Critical Care and Sleep Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramyar","family":"Mahdavi","sequence":"additional","affiliation":[{"name":"Division of Pulmonary, Critical Care and Sleep Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230927","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1164\/rccm.201203-0393OC","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration prevents mediastinoscopies in the diagnosis of isolated mediastinal lymphadenopathy: a prospective trial","volume":"186","author":"Navani","year":"2012","journal-title":"Am J Respir Crit Care Med"},{"key":"R2-20230927","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1378\/chest.15-1216","article-title":"Technical aspects of endobronchial ultrasound-guided transbronchial needle aspiration: CHEST guideline and expert panel report","volume":"149","author":"Wahidi","year":"2016","journal-title":"Chest"},{"key":"R3-20230927","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1111\/j.1440-1843.2010.01871.x","article-title":"Comparison of 21-gauge and 22-gauge aspiration needle during endobronchial ultrasound-guided transbronchial needle aspiration","volume":"16","author":"Nakajima","year":"2011","journal-title":"Respirology"},{"key":"R4-20230927","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/LBR.0b013e3182273b41","article-title":"Comparison of 21-gauge and 22-gauge needles for endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal and hilar lymph nodes","volume":"18","author":"Saji","year":"2011","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R5-20230927","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1111\/resp.12293","article-title":"Impact of needle gauge on characterization of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) histology samples","volume":"19","author":"Jeyabalan","year":"2014","journal-title":"Respirology"},{"key":"R6-20230927","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1378\/chest.12-1205","article-title":"Comparison of 21-gauge and 22-gauge aspiration needle in endobronchial ultrasound-guided transbronchial needle aspiration: results of the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation Registry","volume":"143","author":"Yarmus","year":"2013","journal-title":"Chest"},{"key":"R7-20230927","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/LBR.0b013e318233016c","article-title":"Randomized study of 21-gauge versus 22-gauge endobronchial ultrasound-guided transbronchial needle aspiration needles for sampling histology specimens","volume":"18","author":"Oki","year":"2011","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R8-20230927","doi-asserted-by":"crossref","first-page":"71","DOI":"10.4103\/2303-9027.123011","article-title":"Endoscopic ultrasound-guided fine needle aspiration: how to obtain a core biopsy?","volume":"3","author":"Fuccio","year":"2014","journal-title":"Endosc Ultrasound"},{"key":"R9-20230927","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1097\/MPA.0000000000000217","article-title":"Randomized trial comparing the flexible 19G and 25G needles for endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass lesions","volume":"44","author":"Ramesh","year":"2015","journal-title":"Pancreas"},{"key":"R10-20230927","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1159\/000475504","article-title":"Flexible 19-Gauge endobronchial ultrasound-guided transbronchial needle aspiration needle: first experience","volume":"94","author":"Tyan","year":"2017","journal-title":"Respiration"},{"key":"R11-20230927","doi-asserted-by":"crossref","first-page":"64","DOI":"10.5603\/ARM.2017.0012","article-title":"Initial Polish experience of flexible 19 gauge endobronchial ultrasound-guided transbronchial needle aspiration","volume":"85","author":"Gnass","year":"2017","journal-title":"Adv Respir Med"},{"key":"R12-20230927","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1378\/chest.12-0350","article-title":"Complications, consequences, and practice patterns of endobronchial ultrasound-guided transbronchial needle aspiration: results of the AQuIRE registry","volume":"143","author":"Eapen","year":"2013","journal-title":"Chest"},{"key":"R13-20230927","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.1038\/ajg.2010.108","article-title":"The prospective randomized, controlled trial of endoscopic ultrasound-guided fine-needle aspiration using 22G and 19G aspiration needles for solid pancreatic or peripancreatic masses","volume":"105","author":"Song","year":"2010","journal-title":"Am J Gastroenterol"},{"key":"R14-20230927","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1097\/JTO.0b013e3182a471a9","article-title":"Adequacy of lymph node transbronchial needle aspirates using convex probe endobronchial ultrasound for multiple tumor genotyping techniques in non-small-cell lung cancer","volume":"8","author":"Folch","year":"2013","journal-title":"J Thorac Oncol"},{"key":"R15-20230927","first-page":"A2875","article-title":"Feasibility study of using 19G needle for EBUS-TBNA: a prospective-randomized comparison of 19G and 22G EBUS-needles","volume":"195","author":"Oezkan","year":"2017","journal-title":"Am J Respir Crit Care Med"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01436970-201810000-00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T00:39:46Z","timestamp":1695775186000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01436970-201810000-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000000515","relation":{},"ISSN":["1944-6586"],"issn-type":[{"value":"1944-6586","type":"print"}],"subject":[],"published":{"date-parts":[[2018,10]]}}}