{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T03:04:11Z","timestamp":1793934251233,"version":"4.8.0"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2018,10,1]],"date-time":"2018-10-01T00:00:00Z","timestamp":1538352000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/ http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,10]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Electromagnetic navigation bronchoscopy (ENB) has been widely adopted as a guidance technique for biopsy of peripheral lung nodules. However, ENB is limited by the lack of real-time confirmation of the biopsy devices. Intraprocedural cone-beam computed tomography (CBCT) imaging can be utilized to assess or confirm the location of biopsy devices. The aim of this study is to determine the safety and diagnostic yield (DY) of image fusion of intraprocedural CBCT data with live fluoroscopy (augmented fluoroscopy) during ENB-guided biopsy of peripheral lung nodules.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Data from 75 consecutive patients who underwent biopsy with ENB was collected retrospectively. Patients underwent CBCT imaging while temporarily suspending mechanical ventilation. CBCT data were acquired and 3-dimensional segmentation of nodules was performed using commercially available software (OncoSuite). During ENB, the segmented lesions were projected and fused with live fluoroscopy enabling real-time 3-dimensional guidance.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of 93 lesions with a median size of 16.0 mm were biopsied in 75 consecutive patients. The overall DY by lesion was 83.7% (95% confidence interval, 74.8%-89.9%). Multivariate regression analysis showed no independent correlation between lesion size, lesion location, lesion visibility under standard fluoroscopy, and the presence of a bronchus sign with DY. Pneumothorax occurred in 3 patients (4%).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Intraprocedural CBCT imaging with augmented fluoroscopy is feasible and effective and is associated with high DY during ENB-guided biopsies.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/lbr.0000000000000536","type":"journal-article","created":{"date-parts":[[2018,9,3]],"date-time":"2018-09-03T00:51:05Z","timestamp":1535935865000},"page":"274-282","source":"Crossref","is-referenced-by-count":151,"title":["Cone-Beam CT With Augmented Fluoroscopy Combined With Electromagnetic Navigation Bronchoscopy for Biopsy of Pulmonary Nodules"],"prefix":"10.1097","volume":"25","author":[{"given":"Michael A.","family":"Pritchett","sequence":"first","affiliation":[{"name":"Department of Pulmonary and Critical Care, Chest Center of the Carolinas, FirstHealth Moore Regional Hospital"},{"name":"Pinehurst Medical Clinic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"St\u00e9phanie","family":"Schampaert","sequence":"additional","affiliation":[{"name":"Department of Clinical Science and Innovation, Philips, Best, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joris A.H.","family":"de Groot","sequence":"additional","affiliation":[{"name":"Department of Clinical Science and Innovation, Philips, Best, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles C.","family":"Schirmer","sequence":"additional","affiliation":[{"name":"Department of Pathology, FirstHealth Moore Regional Hospital, Pinehurst, NC"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Imramsjah","family":"van der Bom","sequence":"additional","affiliation":[{"name":"Department of Clinical Science and Innovation, Philips, Best, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230927","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1164\/rccm.201507-1332OC","article-title":"Diagnostic yield and complications of bronchoscopy for peripheral lung lesions. results of the AQuIRE registry","volume":"193","author":"Ost","year":"2016","journal-title":"Am J Respir Crit Care Med"},{"key":"R2-20230927","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/s12890-017-0403-9","article-title":"Electromagnetic navigation bronchoscopy to access lung lesions in 1,000 subjects: first results of the prospective, multicenter NAVIGATE study","volume":"17","author":"Khandhar","year":"2017","journal-title":"BMC Pulm Med"},{"key":"R3-20230927","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1378\/chest.117.4.1049","article-title":"Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules","volume":"117","author":"Baaklini","year":"2000","journal-title":"Chest"},{"key":"R4-20230927","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/S1051-0443(98)70279-9","article-title":"Percutaneous transthoracic needle biopsy of the lung: review of 612 lesions","volume":"9","author":"Swischuk","year":"1998","journal-title":"J Vasc Interv Radiol"},{"key":"R5-20230927","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1007\/s002700010067","article-title":"Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique","volume":"23","author":"Laurent","year":"2000","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R6-20230927","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1148\/radiology.198.3.8628859","article-title":"Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients","volume":"198","author":"Klein","year":"1996","journal-title":"Radiology"},{"key":"R7-20230927","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1148\/radiol.2253011465","article-title":"CT-guided percutaneous fine-needle aspiration biopsy of small (\u22641-cm) pulmonary lesions","volume":"225","author":"Wallace","year":"2002","journal-title":"Radiology"},{"key":"R8-20230927","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1148\/radiology.198.2.8596834","article-title":"Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung","volume":"198","author":"Kazerooni","year":"1996","journal-title":"Radiology"},{"key":"R9-20230927","doi-asserted-by":"crossref","first-page":"W678","DOI":"10.2214\/AJR.10.4659","article-title":"Complications of CT-guided percutaneous needle biopsy of the chest: prevention and management","volume":"196","author":"Wu","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"R10-20230927","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1148\/radiol.2291020499","article-title":"CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate","volume":"229","author":"Geraghty","year":"2003","journal-title":"Radiology"},{"key":"R11-20230927","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1148\/radiology.212.1.r99jl33165","article-title":"Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax","volume":"212","author":"Cox","year":"1999","journal-title":"Radiology"},{"key":"R12-20230927","doi-asserted-by":"crossref","first-page":"137","DOI":"10.7326\/0003-4819-155-3-201108020-00003","article-title":"Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records","volume":"155","author":"Wiener","year":"2011","journal-title":"Ann Intern Med"},{"key":"R13-20230927","doi-asserted-by":"crossref","first-page":"1776","DOI":"10.1378\/chest.12-3046","article-title":"Quality gaps and comparative effectiveness in lung cancer staging: the impact of test sequencing on outcomes","volume":"144","author":"Almeida","year":"2013","journal-title":"Chest"},{"key":"R14-20230927","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.1378\/chest.13-1908","article-title":"Quality-adjusted survival following treatment of malignant pleural effusions with indwelling pleural catheters","volume":"145","author":"Ost","year":"2014","journal-title":"Chest"},{"key":"R15-20230927","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1001\/jama.2015.2365","article-title":"FDG-PET\/CT imaging for mediastinal staging in patients with potentially resectable non-small cell lung cancer","volume":"313","author":"Schmidt-Hansen","year":"2015","journal-title":"JAMA"},{"key":"R16-20230927","first-page":"463","article-title":"Interinstitutional database for comparison of performance in lung fine-needle aspiration cytology. A College of American Pathologists Q-Probe Study of 5264 cases with histologic correlation","volume":"116","author":"Zarbo","year":"1992","journal-title":"Arch Pathol Lab Med"},{"key":"R17-20230927","first-page":"9","article-title":"Bronchoscopic biopsy of peripheral lung lesions under electromagnetic guidance: a pilot study","volume":"12","author":"Becker","year":"2005","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R18-20230927","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1378\/chest.128.1.382","article-title":"Electromagnetic catheter navigation during bronchoscopy: validation of a novel method by conventional fluoroscopy","volume":"128","author":"Hautmann","year":"2005","journal-title":"Chest"},{"key":"R19-20230927","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1378\/chest.129.4.988","article-title":"Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study","volume":"129","author":"Schwarz","year":"2006","journal-title":"Chest"},{"key":"R20-20230927","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1164\/rccm.200603-344OC","article-title":"Electromagnetic navigation diagnostic bronchoscopy: a prospective study","volume":"174","author":"Gildea","year":"2006","journal-title":"Am J Respir Crit Care Med"},{"key":"R21-20230927","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1183\/09031936.00165306","article-title":"Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions","volume":"29","author":"Makris","year":"2007","journal-title":"Eur Respir J"},{"key":"R22-20230927","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1378\/chest.06-3016","article-title":"Electromagnetic navigation diagnostic bronchoscopy in peripheral lung lesions","volume":"131","author":"Eberhardt","year":"2007","journal-title":"Chest"},{"key":"R23-20230927","first-page":"227","article-title":"Improved diagnostic yield of bronchoscopy in a community practice: combination of electromagnetic navigation system and rapid on-site evaluation","volume":"14","author":"Wilson","year":"2007","journal-title":"J Bronchol Intervent Pulmonol"},{"key":"R24-20230927","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s00408-008-9120-8","article-title":"Electromagnetic navigation bronchoscopy in combination with PET-CT and rapid on-site cytopathologic examination for diagnosis of peripheral lung lesions","volume":"187","author":"Lamprecht","year":"2009","journal-title":"Lung"},{"key":"R25-20230927","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1164\/rccm.200612-1866OC","article-title":"Multimodality bronchoscopic diagnosis of peripheral lung lesions: a randomized controlled trial","volume":"176","author":"Eberhardt","year":"2007","journal-title":"Am J Respir Crit Care Med"},{"key":"R26-20230927","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1159\/000226128","article-title":"Accuracy and feasibility of electromagnetic navigated bronchoscopy under nitrous oxide sedation for pulmonary peripheral opacities: an outpatient study","volume":"78","author":"Bertoletti","year":"2009","journal-title":"Respiration"},{"key":"R27-20230927","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1378\/chest.09-2708","article-title":"Diagnostic yield of electromagnetic navigation bronchoscopy is highly dependent on the presence of a Bronchus sign on CT imaging: results from a prospective study","volume":"138","author":"Seijo","year":"2010","journal-title":"Chest"},{"key":"R28-20230927","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1159\/000232394","article-title":"Comparison of suction catheter versus forceps biopsy for sampling of solitary pulmonary nodules guided by electromagnetic navigational bronchoscopy","volume":"79","author":"Eberhardt","year":"2010","journal-title":"Respiration"},{"key":"R29-20230927","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1097\/LBR.0b013e318216cee6","article-title":"Electromagnetic navigational bronchoscopy: an effective and safe approach to diagnose peripheral lung lesions unreachable by conventional bronchoscopy in high-risk patients","volume":"18","author":"Mahajan","year":"2011","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R30-20230927","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/LBR.0b013e31824dd9a1","article-title":"Electromagnetic navigational bronchoscopy in the diagnosis of lung lesions","volume":"19","author":"Brownback","year":"2012","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R31-20230927","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/LBR.0b013e3182616ece","article-title":"Multicenter experience with electromagnetic navigation bronchoscopy for the diagnosis of pulmonary nodules","volume":"19","author":"Jensen","year":"2012","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R32-20230927","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1016\/j.rmed.2012.02.002","article-title":"Electromagnetic navigation bronchoscopy (ENB): Increasing diagnostic yield","volume":"106","author":"Lamprecht","year":"2012","journal-title":"Respir Med"},{"key":"R33-20230927","doi-asserted-by":"crossref","first-page":"944","DOI":"10.1016\/j.athoracsur.2011.11.006","article-title":"Electromagnetic navigation bronchoscopy performed by thoracic surgeons: one center\u2019s early success","volume":"93","author":"Pearlstein","year":"2012","journal-title":"Ann Thorac Surg"},{"key":"R34-20230927","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1002\/cncy.21373","article-title":"The emerging technique of electromagnetic navigation bronchoscopy-guided fine-needle aspiration of peripheral lung lesions: promising results in 50 lesions","volume":"122","author":"Loo","year":"2014","journal-title":"Cancer Cytopathol"},{"key":"R35-20230927","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/LBR.0000000000000120","article-title":"The effect of general anesthesia versus intravenous sedation on diagnostic yield and success in electromagnetic navigation bronchoscopy","volume":"22","author":"Bowling","year":"2015","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R36-20230927","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1378\/chest.11-1764","article-title":"Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule","volume":"142","author":"Wang Memoli","year":"2012","journal-title":"Chest"},{"key":"R37-20230927","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1159\/000355710","article-title":"Diagnostic yield and safety of electromagnetic navigation bronchoscopy for lung nodules: a systematic review and meta-analysis","volume":"87","author":"Gex","year":"2014","journal-title":"Respiration"},{"key":"R38-20230927","doi-asserted-by":"crossref","first-page":"694","DOI":"10.3348\/kjr.2012.13.6.694","article-title":"CT-guided percutaneous transthoracic localization of pulmonary nodules prior to video-assisted thoracoscopic surgery using barium suspension","volume":"13","author":"Lee","year":"2012","journal-title":"Korean J Radiol"},{"key":"R39-20230927","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s00330-015-3861-6","article-title":"Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules","volume":"26","author":"Rotolo","year":"2016","journal-title":"Eur Radiol"},{"key":"R40-20230927","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1016\/j.jvir.2016.05.034","article-title":"Prospective randomized trial for image-guided biopsy using cone-beam ct navigation compared with conventional CT","volume":"27","author":"Abi-Jaoudeh","year":"2016","journal-title":"J Vasc Interv Radiol"},{"key":"R41-20230927","doi-asserted-by":"crossref","first-page":"A877","DOI":"10.1016\/j.chest.2017.08.921","article-title":"Cone Beam CT-guided endobronchial biopsy assisted by augmented fluoroscopy","volume":"152","author":"Pritchett","year":"2017","journal-title":"Chest"},{"key":"R42-20230927","doi-asserted-by":"crossref","first-page":"d4770","DOI":"10.1136\/bmj.d4770","article-title":"Verification problems in diagnostic accuracy studies: consequences and solutions","volume":"343","author":"de Groot","year":"2011","journal-title":"BMJ"},{"key":"R45-20230927","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.jvir.2011.02.011","article-title":"Effective dose during needle interventions: cone-beam CT guidance compared with conventional CT guidance","volume":"22","author":"Braak","year":"2011","journal-title":"J Vasc Interv Radiol"},{"key":"R46-20230927","doi-asserted-by":"crossref","first-page":"231","DOI":"10.7150\/jca.8834","article-title":"Cone beam computertomography (CBCT) in interventional chest medicine\u2014high feasibility for endobronchial realtime navigation","volume":"5","author":"Hohenforst-Schmidt","year":"2014","journal-title":"J Cancer"},{"key":"R47-20230927","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1111\/1759-7714.12417","article-title":"Factors associated with the diagnostic yield of computed tomography-guided transbronchial lung biopsy","volume":"8","author":"Park","year":"2017","journal-title":"Thorac Cancer"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01436970-201810000-00007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T04:46:02Z","timestamp":1695789962000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01436970-201810000-00007"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10]]},"references-count":45,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000000536","relation":{},"ISSN":["1944-6586"],"issn-type":[{"value":"1944-6586","type":"print"}],"subject":[],"published":{"date-parts":[[2018,10]]}}}