{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:41:44Z","timestamp":1787010104683,"version":"build-2736575974"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Previous studies have shown that needle gauge size has no significant impact on diagnostic yield during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Our objective was to determine whether cell blocks obtained via the new Flex 19G EBUS-TBNA needle would contain more cellular material based on cell area compared with those obtained from a 21G needle.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A prospective analysis of patients undergoing EBUS-TBNA at our institutions was performed. Sampling of the same lesion(s) with both the Flex 19G and 21G needles was performed in an alternating manner. In total, 47 patients with suspected lung cancer or mediastinal\/hilar lymphadenopathy were included with a total of 83 lesions biopsied. Cell block area was calculated using the Aperio ImageScope software.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Mean cell area in the Flex 19G group was 7.34\u00b112.46\u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      compared with 5.23\u00b110.73\u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      in the 21G group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.02). In the malignant subgroup, the average cell area was 16.16\u00b116.30\u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      in the Flex 19G group versus 11.09\u00b115.55\u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      in the 21G group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.02). No significant difference was noted in the mean cell area within the nonmalignant subgroup, 1.80\u00b13.01\u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      in the 19G group versus 1.56\u00b11.79\u2009mm\n                      <jats:sup>2<\/jats:sup>\n                      in the 21G group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.60).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The cell area obtained via the 19G needle was significantly larger than that obtained with the 21G needle. Further multicenter randomized studies are needed to identify the utility of the Flex 19G needle in diagnosing\/subtyping lymphoproliferative disorders and adequacy for molecular testing in non\u2013small cell lung cancer.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/lbr.0000000000000562","type":"journal-article","created":{"date-parts":[[2018,12,19]],"date-time":"2018-12-19T22:28:13Z","timestamp":1545258493000},"page":"237-244","source":"Crossref","is-referenced-by-count":39,"title":["Tissue Acquisition During EBUS-TBNA"],"prefix":"10.1097","volume":"26","author":[{"given":"Edward M.","family":"Pickering","sequence":"first","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Van K.","family":"Holden","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathon E.","family":"Heath","sequence":"additional","affiliation":[{"name":"Department of Pathology, University of Maryland School of Medicine, Baltimore, MD"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Avelino C.","family":"Verceles","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Or","family":"Kalchiem-Dekel","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashutosh","family":"Sachdeva","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230927","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.1378\/chest.14-1355","article-title":"Diagnosing and staging lung cancer involving the mediastinum","volume":"147","author":"Murgu","year":"2015","journal-title":"Chest"},{"key":"R2-20230927","doi-asserted-by":"crossref","first-page":"2245","DOI":"10.1001\/jama.2010.1705","article-title":"Mediastinoscopy vs endosonography for mediastinal nodal staging of lung cancer: a randomized trial","volume":"304","author":"Annema","year":"2010","journal-title":"JAMA"},{"key":"R3-20230927","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1097\/JTO.0b013e3181753b5e","article-title":"Diagnosis of mediastinal adenopathy-real-time endobronchial ultrasound guided needle aspiration versus mediastinoscopy","volume":"3","author":"Ernst","year":"2008","journal-title":"J Thorac Oncol"},{"key":"R4-20230927","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.1016\/j.jtcvs.2011.08.037","article-title":"A prospective controlled trial of endobronchial ultrasound-guided transbronchial needle aspiration compared with mediastinoscopy for mediastinal lymph node staging of lung cancer","volume":"142","author":"Yasufuku","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R5-20230927","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1164\/rccm.201203-0393OC","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration prevents mediastinoscopies in the diagnosis of isolated mediastinal lymphadenopathy: a prospective trial","volume":"186","author":"Navani","year":"2012","journal-title":"Am J Respir Crit Care Med"},{"key":"R6-20230927","first-page":"CD010383","article-title":"First-line treatment of advanced epidermal growth factor receptor (EGFR) mutation positive non-squamous non-small cell lung cancer","volume":"5","author":"Greenhalgh","year":"2016","journal-title":"Cochrane Database Syst Rev"},{"key":"R7-20230927","doi-asserted-by":"crossref","first-page":"1336","DOI":"10.1513\/AnnalsATS.201503-165OC","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration for the diagnosis and subtyping of lymphoma","volume":"12","author":"Grosu","year":"2015","journal-title":"Ann Am Thorac Soc"},{"key":"R8-20230927","doi-asserted-by":"crossref","first-page":"1856","DOI":"10.1016\/j.athoracsur.2015.12.019","article-title":"Endobronchial ultrasound-transbronchial needle aspiration for lymphoma in patients with low suspicion for lung cancer and mediastinal lymphadenopathy","volume":"101","author":"Nason","year":"2016","journal-title":"Ann Thorac Surg"},{"key":"R9-20230927","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1378\/chest.12-1205","article-title":"Comparison of 21-gauge and 22-gauge aspiration needle in endobronchial ultrasound-guided transbronchial needle aspiration: results of the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation Registry","volume":"143","author":"Yarmus","year":"2013","journal-title":"Chest"},{"key":"R10-20230927","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1111\/j.1440-1843.2010.01871.x","article-title":"Comparison of 21-gauge and 22-gauge aspiration needle during endobronchial ultrasound-guided transbronchial needle aspiration","volume":"16","author":"Nakajima","year":"2011","journal-title":"Respirology"},{"key":"R11-20230927","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1111\/resp.12293","article-title":"Impact of needle gauge on characterization of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) histology samples","volume":"19","author":"Jeyabalan","year":"2014","journal-title":"Respirology"},{"key":"R12-20230927","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/LBR.0b013e318233016c","article-title":"Randomized study of 21-gauge versus 22-gauge endobronchial ultrasound-guided transbronchial needle aspiration needles for sampling histology specimens","volume":"18","author":"Oki","year":"2011","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R13-20230927","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/LBR.0b013e3182273b41","article-title":"Comparison of 21-gauge and 22-gauge needles for endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal and hilar lymph nodes","volume":"18","author":"Saji","year":"2011","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R14-20230927","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1159\/000475504","article-title":"Flexible 19-gauge endobronchial ultrasound-guided transbronchial needle aspiration needle: first experience","volume":"94","author":"Tyan","year":"2017","journal-title":"Respiration"},{"key":"R15-20230927","doi-asserted-by":"crossref","first-page":"64","DOI":"10.5603\/ARM.2017.0012","article-title":"Initial Polish experience of flexible 19 gauge endobronchial ultrasound-guided transbronchial needle aspiration","volume":"85","author":"Gnass","year":"2017","journal-title":"Adv Respir Med"},{"key":"R16-20230927","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/LBR.0000000000000500","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration with a 19-G needle device","volume":"25","author":"Tremblay","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R17-20230927","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1097\/LBR.0000000000000526","article-title":"Use of an additional 19-G EBUS-TBNA needle increases the diagnostic yield of EBUS-TBNA","volume":"25","author":"Garrison","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R18-20230927","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/LBR.0000000000000515","article-title":"Comparison of sample adequacy and diagnostic yield of 19- and 22-G EBUS-TBNA needles","volume":"25","author":"Chaddha","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R19-20230927","doi-asserted-by":"crossref","first-page":"915","DOI":"10.4081\/monaldi.2018.915","article-title":"The effect of 19-gauge endobronchial ultrasound-guided transbronchial needle aspiration biopsies on characterization of malignant and benign disease. The Bristol experience","volume":"88","author":"Jones","year":"2018","journal-title":"Monaldi Arch Chest Dis"},{"key":"R20-20230927","doi-asserted-by":"crossref","first-page":"2388","DOI":"10.21037\/jtd.2018.04.50","article-title":"Clinical evaluation of the utility of a flexible 19-gauge EBUS-TBNA needle","volume":"10","author":"Kinoshita","year":"2018","journal-title":"J Thorac Dis"},{"key":"R21-20230927","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1159\/000489473","article-title":"A randomized clinical trial of flex 19G needles versus 22G needles for endobronchial ultrasonography in suspected lung cancer","volume":"96","author":"Dooms","year":"2018","journal-title":"Respiration"},{"key":"R22-20230927","first-page":"PA823","article-title":"Comparison of diagnostic performance of 19-gauge and 21-gauge needles during endobronchial ultrasound-guided transbronchial needle aspiration","volume":"50","author":"Porfyridis","year":"2017","journal-title":"Eur Respir J"},{"key":"R23-20230927","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1097\/JTO.0b013e3181a0d82e","article-title":"The IASLC lung cancer staging project: a proposal for a new international lymph node map in the forthcoming seventh edition of the TNM classification for lung cancer","volume":"4","author":"Rusch","year":"2009","journal-title":"J Thorac Oncol"},{"key":"R24-20230927","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1159\/000332321","article-title":"Cellular fixation: a study of cytorich red and cytospin collection fluid","volume":"41","author":"Weidmann","year":"1997","journal-title":"Acta Cytol"},{"key":"R25-20230927","doi-asserted-by":"crossref","first-page":"1622","DOI":"10.2214\/AJR.06.1403","article-title":"Diffusion-weighted MRI in the body: applications and challenges in oncology","volume":"188","author":"Koh","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"R26-20230927","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1097\/RLI.0b013e3181bbdc2f","article-title":"Preliminary results for characterization of pelvic lymph nodes in patients with prostate cancer by diffusion-weighted MR-imaging","volume":"45","author":"Eiber","year":"2010","journal-title":"Invest Radiol"},{"key":"R27-20230927","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1159\/000480154","article-title":"A preclinical evaluation comparing the performance of a novel 19-G flexible needle to a commercially available 22-G EBUS-TBNA needle","volume":"95","author":"Czarnecka-Kujawa","year":"2018","journal-title":"Respiration"},{"key":"R28-20230927","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.rmed.2012.02.014","article-title":"Efficacy and safety of convex probe EBUS-TBNA in sarcoidosis: a systematic review and meta-analysis","volume":"106","author":"Agarwal","year":"2012","journal-title":"Respir Med"},{"key":"R29-20230927","doi-asserted-by":"crossref","first-page":"2457","DOI":"10.1001\/jama.2013.5823","article-title":"Endosonography vs conventional bronchoscopy for the diagnosis of sarcoidosis: the GRANULOMA randomized clinical trial","volume":"309","author":"von Bartheld","year":"2013","journal-title":"JAMA"},{"key":"R30-20230927","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1097\/LBR.0000000000000502","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration using 19-G needle for sarcoidosis","volume":"25","author":"Balwan","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R31-20230927","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1038\/ajg.2011.350","article-title":"Endoscopic ultrasound-guided fine needle aspiration biopsy for diagnosis of lymphoproliferative disorders: feasibility of immunohistological, flow cytometric, and cytogenetic assessments","volume":"107","author":"Yasuda","year":"2012","journal-title":"Am J Gastroenterol"},{"key":"R32-20230927","doi-asserted-by":"crossref","first-page":"3673","DOI":"10.1200\/JCO.2014.57.3055","article-title":"Molecular testing for selection of patients of lung cancer for epidermal growth factor receptor and anaplastic lymphoma kinase tyrosine kinase inhibitors: American Society of Clinical Oncology endorsement of the College of American Pathologists\/International Association for the study of lung cancer\/association for molecular pathology guideline","volume":"32","author":"Leighl","year":"2014","journal-title":"J Clin Oncol"},{"key":"R33-20230927","doi-asserted-by":"crossref","first-page":"1681","DOI":"10.1093\/annonc\/mdu145","article-title":"Second ESMO consensus conference on lung cancer: pathology and molecular biomarkers for non-small-cell lung cancer","volume":"25","author":"Kerr","year":"2014","journal-title":"Ann Oncol"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000562","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T00:46:03Z","timestamp":1695775563000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000562"}},"subtitle":["Comparison of Cell Blocks Obtained From a 19G Versus 21G Needle"],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":33,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000000562","relation":{},"ISSN":["1944-6586"],"issn-type":[{"value":"1944-6586","type":"print"}],"subject":[],"published":{"date-parts":[[2019,10]]}}}