{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:41:44Z","timestamp":1787010104709,"version":"build-2736575974"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS TBNA) of mediastinal lymphadenopathy has been shown to be equivalent and possibly even superior to mediastinoscopy. Since the original dedicated 22-G aspiration needle, 21-G, 25-G, and recently 19-G needles have been introduced. Smaller needles may be more flexible and adept at accessing more difficult nodes, and may have less blood contamination compared with larger needles.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients and Methods:<\/jats:title>\n                    <jats:p>This is a prospective observational study of 50 consecutive patients who underwent endobronchial ultrasound-guided transbronchial needle aspiration with a 21-G needle and a 25-G needle for a total of 100 biopsies. The study slides were examined by a dedicated lung cytopathologist, who was blinded to the needle size used for each slide. Demographic data, and lymph node size were recorded. Comparisons between the 2 needles with regards to sample adequacy and diagnostic yield was performed using the McNemar test for dichotomous variables and marginal homogeneity test for nondichotomous variables since samples were related.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The majority of lymph nodes (96%) were at least &gt;1\u2009cm. Adequate specimens were obtained in 78% of cases with the 21-G needle and 86% of cases with 25-G needle (P-value=0.424). The overall diagnostic yield was 74% and 80% with the 21-G needle and 25-G needle, respectively (P-value=0.607).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Our study demonstrates that the there is no difference in terms of specimen adequacy and diagnostic yield when the 25-G needle is compared with the 21-G needle.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/lbr.0000000000000753","type":"journal-article","created":{"date-parts":[[2021,2,25]],"date-time":"2021-02-25T11:27:02Z","timestamp":1614252422000},"page":"34-38","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Comparison of Sample Adequacy and Diagnostic Yield of the 21-G and 25-G EBUS TBNA Needles"],"prefix":"10.1097","volume":"29","author":[{"given":"Rahul","family":"Sood","sequence":"first","affiliation":[{"name":"Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Alape","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, UMASS Memorial Medical Center, University of Massachusetts, Worcester"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dhaval","family":"Thakkar","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Southern Arizona Veterans Affairs Health Care System-Tuscon, Tucson, AZ"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Shadchehr","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ghazwan","family":"Acash","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce J.","family":"Tronic","sequence":"additional","affiliation":[{"name":"Department of Anatomic Pathology, Lahey Hospital and Medical Center, Burlington, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla R.","family":"Lamb","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,2,8]]},"reference":[{"key":"R1-20240809","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1097\/JTO.0000000000000388","article-title":"Endobronchial ultrasound versus mediastinoscopy for mediastinal nodal staging of non-small-cell lung cancer","volume":"10","author":"Um","year":"2015","journal-title":"J Thorac Oncol"},{"key":"R2-20240809","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.1016\/j.jtcvs.2011.08.037","article-title":"A prospective controlled trial of endobronchial ultrasound-guided transbronchial needle aspiration compared with mediastinoscopy for mediastinal lymph node staging of lung cancer","volume":"142","author":"Yasufuku","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"suppl","key":"R3-20240809","doi-asserted-by":"crossref","first-page":"e211S","DOI":"10.1378\/chest.12-2355","article-title":"Methods for staging non-small cell lung cancer: diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines","volume":"143","author":"Silvestri","year":"2013","journal-title":"Chest"},{"key":"R4-20240809","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1378\/chest.15-1216","article-title":"Technical aspects of endobronchial ultrasound-guided transbronchial needle aspiration: CHEST guideline and expert panel report","volume":"149","author":"Wahidi","year":"2016","journal-title":"Chest"},{"key":"R5-20240809","doi-asserted-by":"crossref","first-page":"24","DOI":"10.21037\/shc.2019.11.14","article-title":"Endobronchial ultrasound needles: does size matter?","volume":"4","author":"Kanth","year":"2020","journal-title":"Shanghai Chest"},{"key":"R6-20240809","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/LBR.0000000000000515","article-title":"Comparison of sample adequacy and diagnostic yield of 19- and 22-G EBUS-TBNA needles","volume":"25","author":"Chaddha","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R7-20240809","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1111\/j.1440-1746.2008.05636.x","article-title":"Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses","volume":"24","author":"Sakamoto","year":"2009","journal-title":"J Gastroenterol Hepatol"},{"key":"R8-20240809","doi-asserted-by":"crossref","first-page":"877","DOI":"10.3109\/00365521.2013.799222","article-title":"Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS\u2013FNA needles in solid masses","volume":"48","author":"Vilmann","year":"2013","journal-title":"Scand J Gastroenterol"},{"key":"R9-20240809","doi-asserted-by":"crossref","first-page":"e17","DOI":"10.1097\/LBR.0000000000000428","article-title":"Utility of a 25- versus 22-G EBUS needle in difficult-to-acess 2R lymph nodes","volume":"25","author":"Gafoor","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R11-20240809","doi-asserted-by":"crossref","first-page":"3643","DOI":"10.21037\/jtd.2019.04.20","article-title":"Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration","volume":"11","author":"Di Felice","year":"2019","journal-title":"J Thorac Dis"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000753","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T11:16:06Z","timestamp":1723202166000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000753"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,8]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000000753","relation":{},"ISSN":["1944-6586"],"issn-type":[{"value":"1944-6586","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2,8]]},"assertion":[{"value":"2020-04-17","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-01-07","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}