{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T11:19:19Z","timestamp":1790680759000,"version":"4.1.0"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>This study aims to correlate nodule, patient, and technical risk factors less commonly investigated in the literature with pneumothorax development during computed tomography-guided core needle lung nodule biopsy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients and Methods:<\/jats:title>\n                    <jats:p>Retrospective data on 671 computed tomography-guided percutaneous core needle lung biopsies from 671 patients at a tertiary care center between March 2014 and August 2016. Univariate and multivariable logistic regression analyses were used to identify pneumothorax risk factors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The overall incidence of pneumothorax was 26.7% (n=179). Risk factors identified on univariate analysis include anterior [odds ratio (OR)=1.98;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001] and lateral (OR=2.17;\n                      <jats:italic toggle=\"yes\">P=<\/jats:italic>\n                      0.002) pleural surface puncture relative to posterior puncture, traversing more than one pleural surface with the biopsy needle (OR=2.35;\n                      <jats:italic toggle=\"yes\">P=<\/jats:italic>\n                      0.06), patient positioning in supine (OR=2.01;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001) and decubitus nodule side up (OR=2.54;\n                      <jats:italic toggle=\"yes\">P=<\/jats:italic>\n                      0.001) orientation relative to decubitus nodule side down positioning, and presence of emphysema in the path of the biopsy needle (OR=3.32;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). In the multivariable analysis, the presence of emphysematous parenchyma in the path of the biopsy needle was correlated most strongly with increased odds of pneumothorax development (OR=3.03;\n                      <jats:italic toggle=\"yes\">P=<\/jats:italic>\n                      0.0004). Increased body mass index (OR=0.95;\n                      <jats:italic toggle=\"yes\">P=<\/jats:italic>\n                      0.001) and larger nodule width (cm; OR=0.74;\n                      <jats:italic toggle=\"yes\">P=<\/jats:italic>\n                      0.02) were protective factors most strongly correlated with decreased odds of pneumothorax development.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Emphysema in the needle biopsy path is most strongly associated with pneumothorax development. Increases in patient body mass index and width of the target lung nodule are most strongly associated with decreased odds of pneumothorax.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/lbr.0000000000000816","type":"journal-article","created":{"date-parts":[[2021,10,19]],"date-time":"2021-10-19T23:06:58Z","timestamp":1634684818000},"page":"198-205","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Risk Factors for Pneumothorax Development Following CT-Guided Core Lung Nodule Biopsy"],"prefix":"10.1097","volume":"29","author":[{"given":"Tyler","family":"Sargent","sequence":"first","affiliation":[{"name":"Oakland University William Beaumont School of Medicine, Rochester"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathan","family":"Kolderman","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology and Molecular Imaging"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Girish B.","family":"Nair","sequence":"additional","affiliation":[{"name":"Division of Pulmonary Critical Care, Beaumont Health System, Royal Oak, MI"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle","family":"Jankowski","sequence":"additional","affiliation":[{"name":"Oakland University William Beaumont School of Medicine, Rochester"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sayf","family":"Al-Katib","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology and Molecular Imaging"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,10,14]]},"reference":[{"key":"R1-20240809","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1055\/s-0033-1342952","article-title":"Percutaneous lung biopsy: technique, efficacy, and complications","volume":"30","author":"Winokur","year":"2013","journal-title":"Semin Intervent Radiol"},{"key":"R2-20240809","doi-asserted-by":"crossref","first-page":"16","DOI":"10.3747\/co.19.871","article-title":"Fine-needle aspiration biopsy versus core-needle biopsy in diagnosing lung cancer: a systematic review","volume":"19","author":"Yao","year":"2012","journal-title":"Curr Oncol"},{"key":"R3-20240809","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.2147\/OTT.S45013","article-title":"Diagnostic efficacy of computed tomography-guided transthoracic needle aspiration and biopsy in patients with pulmonary disease","volume":"6","author":"Ozkaya","year":"2013","journal-title":"Onco Targets Ther"},{"key":"R4-20240809","first-page":"S99","article-title":"Pneumothorax after transthoracic needle biopsy of lung lesions under CT guidance","volume":"6","author":"Boskovic","year":"2014","journal-title":"J Thorac Dis"},{"key":"R5-20240809","doi-asserted-by":"crossref","first-page":"19","DOI":"10.2478\/v10019-012-0004-4","article-title":"Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy","volume":"46","author":"Beslic","year":"2012","journal-title":"Radiol Oncol"},{"key":"R6-20240809","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1148\/radiology.198.3.8628859","article-title":"Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients","volume":"198","author":"Klein","year":"1996","journal-title":"Radiology"},{"key":"R7-20240809","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1097\/01.RVI.0000071087.76348.C7","article-title":"Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures","volume":"14","author":"Yeow","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"R8-20240809","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1007\/s00330-016-4357-8","article-title":"Complication rates of CT-guided transthoracic lung biopsy: meta-analysis","volume":"27","author":"Heerink","year":"2017","journal-title":"Eur Radiol"},{"key":"R9-20240809","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1259\/bjr.20190866","article-title":"Pneumothorax rates in CT-Guided lung biopsies: a comprehensive systematic review and meta-analysis of risk factors","volume":"93","author":"Huo","year":"2020","journal-title":"Br J Radiol"},{"key":"R10-20240809","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1007\/s00270-015-1097-0","article-title":"The effect of needle gauge on the risk of pneumothorax and chest tube placement after percutaneous computed tomographic (CT)-guided lung biopsy","volume":"38","author":"Kuban","year":"2015","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R11-20240809","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/S1051-0443(98)70279-9","article-title":"Percutaneous transthoracic needle biopsy of the lung: review of 612 lesions","volume":"9","author":"Swischuk","year":"1998","journal-title":"J Vasc Interv Radiol"},{"key":"R12-20240809","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1148\/radiol.2291020499","article-title":"CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate","volume":"229","author":"Geraghty","year":"2003","journal-title":"Radiology"},{"key":"R14-20240809","doi-asserted-by":"crossref","first-page":"W511","DOI":"10.2214\/AJR.10.4657","article-title":"CT-guided percutaneous needle biopsy of the chest: preprocedural evaluation and technique","volume":"196","author":"Wu","year":"2011","journal-title":"Am J Roentgenol"},{"key":"R15-20240809","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1148\/radiol.2019182321","article-title":"CT-guided lung biopsy: effect of biopsy-side down position on pneumothorax and chest tube placement","volume":"292","author":"Drumm","year":"2019","journal-title":"Radiology"},{"key":"R16-20240809","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1148\/radiol.11103506","article-title":"Rapid needle-out patient-rollover time after percutaneous CT-guided transthoracic biopsy of lung nodules: effect on pneumothorax rate","volume":"262","author":"O\u2019Neill","year":"2011","journal-title":"Radiology"},{"key":"R17-20240809","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1148\/radiology.208.2.9680552","article-title":"Technical aspects of needle aspiration lung biopsy: a personal perspective","volume":"208","author":"Moore","year":"1998","journal-title":"Radiology"},{"key":"R18-20240809","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1148\/radiology.175.3.2343123","article-title":"Positional precautions in needle aspiration lung biopsy","volume":"175","author":"Moore","year":"1990","journal-title":"Radiology"},{"key":"R19-20240809","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1148\/radiology.181.2.1924776","article-title":"Effect of patient positioning after needle aspiration lung biopsy","volume":"181","author":"Moore","year":"1991","journal-title":"Radiology"},{"key":"R20-20240809","first-page":"51","article-title":"Position may stop pneumothorax progression in dogs","volume":"126","author":"Zidulka","year":"1982","journal-title":"Am Rev Respir Dis"},{"key":"R21-20240809","doi-asserted-by":"crossref","first-page":"926","DOI":"10.2214\/AJR.05.0226","article-title":"CT-guided transthoracic needle biopsy using a puncture site-down positioning technique","volume":"187","author":"Kinoshita","year":"2006","journal-title":"Am J Roentgenol"},{"key":"R22-20240809","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1055\/s-0031-1273943","article-title":"Transthoracic needle biopsy","volume":"28","author":"Birchard","year":"2011","journal-title":"Semin Intervent Radiol"},{"key":"R23-20240809","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/S0009-9260(96)80191-7","article-title":"CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration","volume":"51","author":"Arakawa","year":"1996","journal-title":"Clin Radiol"},{"key":"R24-20240809","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1148\/radiology.176.3.2389013","article-title":"Automated biopsy devices: significance and safety","volume":"176","author":"Bernardino","year":"1990","journal-title":"Radiology"},{"key":"R25-20240809","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1056\/NEJM199005103221906","article-title":"Interventional radiology in the chest and abdomen","volume":"322","author":"Mueller","year":"1990","journal-title":"N Engl J Med"},{"key":"R26-20240809","doi-asserted-by":"crossref","first-page":"407","DOI":"10.5114\/pjr.2018.79205","article-title":"Risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle biopsy of lung lesions: a single-centre experience with 822 biopsies","volume":"83","author":"Ozturk","year":"2018","journal-title":"Polish J Radiol"},{"key":"R27-20240809","doi-asserted-by":"crossref","first-page":"S211","DOI":"10.1016\/j.jvir.2018.01.547","article-title":"Abstract No. 502. Increased rate of pneumothorax in underweight patient after CT-guided lung biopsy","volume":"29","author":"Hussain","year":"2018","journal-title":"J Vasc Interv Radiol"},{"key":"R28-20240809","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1148\/radiology.218.2.r01fe33491","article-title":"Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?","volume":"218","author":"Ko","year":"2001","journal-title":"Radiology"},{"key":"R29-20240809","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1378\/chest.93.4.742","article-title":"Prediction of pneumothorax rate in percutaneous needle aspiration of the lung","volume":"93","author":"Miller","year":"1988","journal-title":"Chest"},{"key":"R30-20240809","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1007\/s00270-015-1167-3","article-title":"Pneumothorax complicating coaxial and non-coaxial CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients","volume":"39","author":"Nour-Eldin","year":"2016","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R31-20240809","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1007\/s11547-011-0619-9","article-title":"Risk factors for complications of CT-guided lung biopsies","volume":"116","author":"Rizzo","year":"2011","journal-title":"Radiol Medica"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000816","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T11:23:06Z","timestamp":1723202586000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000816"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,14]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000000816","relation":{},"ISSN":["1944-6586"],"issn-type":[{"value":"1944-6586","type":"print"}],"subject":[],"published":{"date-parts":[[2021,10,14]]},"assertion":[{"value":"2021-05-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-09-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}