{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T05:34:03Z","timestamp":1793424843967,"version":"4.5.0"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2022,9,6]],"date-time":"2022-09-06T00:00:00Z","timestamp":1662422400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/ http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Robotic assisted bronchoscopy (RAB) is designed to increase bronchoscopic accessibility for difficult to reach pulmonary lesions. One limitation to success of RAB is computed tomography (CT) to body divergence. Real time imaging with cone beam CT is increasingly utilized for confirmation of correct navigation and tool-in-lesion during RAB. O-arm CT is a 3-dimensional imaging modality, which has not previously been described for use with RAB. Our purpose is to display the feasibility, ease of use, and high rate of confirmation of tool-in-lesion when using O-arm CT during RAB.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Single center, retrospective review of 75 patients undergoing RAB with intraprocedural use of O-arm CT.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Median patient age was 65 years. Forty-nine percent of cases involved nodules \u22642\u00a0cm. Bronchus sign was absent in 44% of cases. Median procedure time was 80 minutes. Median number of O-arm CT runs per case was 2. The median effective dose of radiation was 7.2 millisieverts. Tool-in-lesion was confirmed in 97% (77 of 79) of cases. Definitive diagnosis was reached in 61 to 68 of 79 cases (77% to 86%). There were 2 cases of pneumothorax (2.5%), one of which needed intervention with tube thoracostomy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>O-arm CT is an effective, and convenient alternative to other 3-dimensional imaging modalities for intraprocedural confirmation of tool-in-lesion during RAB.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/lbr.0000000000000894","type":"journal-article","created":{"date-parts":[[2022,9,6]],"date-time":"2022-09-06T14:00:12Z","timestamp":1662472812000},"page":"155-162","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":28,"title":["O-arm CT for Confirmation of Successful Navigation During Robotic Assisted Bronchoscopy"],"prefix":"10.1097","volume":"30","author":[{"given":"Jefferson","family":"Chambers","sequence":"first","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Intermountain Medical Center, Murray"},{"name":"Division of Pulmonary and Critical Care Medicine, University of Utah, Salt Lake City, UT"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Knox","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Intermountain Medical Center, Murray"},{"name":"Division of Pulmonary and Critical Care Medicine, University of Utah, Salt Lake City, UT"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy","family":"Leclair","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Intermountain Medical Center, Murray"},{"name":"Division of Pulmonary and Critical Care Medicine, University of Utah, Salt Lake City, UT"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,4]]},"reference":[{"key":"R1-20240809","first-page":"395","article-title":"Reduced lung-cancer mortality with low-dose computed tomographic screening","volume":"5","year":"2011","journal-title":"N Engl J Med"},{"key":"R2-20240809","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1164\/rccm.201505-0990OC","article-title":"Recent trends in the identification of incidental pulmonary nodules","volume":"10","author":"Gould","year":"2015","journal-title":"Am J Respir Crit Care Med"},{"key":"R3-20240809","doi-asserted-by":"crossref","first-page":"e93S","DOI":"10.1378\/chest.12-2351","article-title":"Evaluation of individuals with pulmonary nodules: when is it lung cancer? Diagnosis and management of lung cancer: American College of Chest Physicians evidence-based clinical practice guidelines","volume":"5","author":"Gould","year":"2013","journal-title":"Chest"},{"key":"R4-20240809","doi-asserted-by":"crossref","first-page":"137","DOI":"10.7326\/0003-4819-155-3-201108020-00003","article-title":"Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records","volume":"3","author":"Wiener","year":"2011","journal-title":"Ann Intern Med"},{"key":"R5-20240809","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1159\/000355710","article-title":"Diagnostic yield and safety of electromagnetic navigation bronchoscopy for lung nodules: a systematic review and meta-analysis","volume":"2","author":"Gex","year":"2014","journal-title":"Respiration"},{"key":"R6-20240809","doi-asserted-by":"crossref","first-page":"1753","DOI":"10.1016\/j.chest.2020.05.534","article-title":"Sensitivity and safety of electromagnetic navigation bronchoscopy for lung cancer diagnosis: systematic review and meta-analysis","volume":"4","author":"Folch","year":"2020","journal-title":"Chest"},{"key":"R7-20240809","first-page":"1","article-title":"Electromagnetic navigation bronchoscopy to access lung lesions in 1,000 subjects: first results of the prospective, multicenter NAVIGATE study","volume":"1","author":"Khandhar","year":"2017","journal-title":"BMC Pulm Med"},{"key":"R8-20240809","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.jtho.2018.11.013","article-title":"Electromagnetic navigation bronchoscopy for peripheral pulmonary lesions: one-year results of the prospective, multicenter NAVIGATE study","volume":"3","author":"Folch","year":"2019","journal-title":"J Thorac Oncol"},{"issue":"suppl 4","key":"R9-20240809","first-page":"S304","article-title":"Transthoracic needle biopsy of the lung","volume":"7","author":"DiBardino","year":"2015","journal-title":"J Thorac Dis"},{"key":"R10-20240809","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.athoracsur.2021.06.086","article-title":"Ion: technology and techniques for shape-sensing robotic-assisted bronchoscopy","volume":"1","author":"Reisenauer","year":"2022","journal-title":"Ann Thorac Surg"},{"key":"R11-20240809","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.chest.2020.08.2047","article-title":"Robotic bronchoscopy for peripheral pulmonary lesions: a multicenter pilot and feasibility study (BENEFIT)","volume":"2","author":"Chen","year":"2021","journal-title":"Chest"},{"key":"R12-20240809","first-page":"1","article-title":"Robot-assisted bronchoscopy for pulmonary lesion diagnosis: results from the initial multicenter experience","volume":"1","author":"Chaddha","year":"2019","journal-title":"BMC Pulm Med"},{"key":"R13-20240809","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.21037\/jtd.2020.01.35","article-title":"Virtual or reality: divergence between preprocedural computed tomography scans and lung anatomy during guided bronchoscopy","volume":"4","author":"Pritchett","year":"2020","journal-title":"J Thorac Dis"},{"key":"R14-20240809","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1378\/chest.14-1425","article-title":"The effect of respiratory motion on pulmonary nodule location during electromagnetic navigation bronchoscopy","volume":"5","author":"Chen","year":"2015","journal-title":"Chest"},{"key":"R15-20240809","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1097\/LBR.0000000000000536","article-title":"Cone-beam CT with augmented fluoroscopy combined with electromagnetic navigation bronchoscopy for biopsy of pulmonary nodules","volume":"4","author":"Pritchett","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R16-20240809","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s00408-021-00421-1","article-title":"Robotic-assisted navigation bronchoscopy as a paradigm shift in peripheral lung access","volume":"2","author":"Benn","year":"2021","journal-title":"Lung"},{"key":"R17-20240809","first-page":"1","article-title":"Video-assisted thoracoscopic surgery using mobile computed tomography: new method for locating of small lung nodules","volume":"1","author":"Ohtaka","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R18-20240809","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1097\/LBR.0000000000000738","article-title":"Feasibility of using the O-arm imaging system during ENB-rEBUS\u2013guided peripheral lung biopsy: a dual-center experience","volume":"4","author":"Cho","year":"2021","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R19-20240809","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1097\/LBR.0000000000000697","article-title":"Cone-beam CT image guidance with and without electromagnetic navigation bronchoscopy for biopsy of peripheral pulmonary lesions","volume":"1","author":"Verhoeven","year":"2021","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R20-20240809","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.chest.2021.07.2169","article-title":"Shape-sensing robotic-assisted bronchoscopy in the diagnosis of pulmonary parenchymal lesions","volume":"161","author":"Kalchiem-Dekel","year":"2022","journal-title":"Chest"},{"key":"R21-20240809","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1002\/acm2.12534","article-title":"Radiation dose and image quality comparison during spine surgery with two different, intraoperative 3D imaging navigation systems","volume":"2","author":"Nachabe","year":"2019","journal-title":"J Appl Clin Med Phys"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000894","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T15:25:28Z","timestamp":1723217128000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000894"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,6]]},"references-count":21,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000000894","relation":{},"ISSN":["1948-8270"],"issn-type":[{"value":"1948-8270","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,6]]},"assertion":[{"value":"2021-12-02","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-07-29","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}