{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T03:56:36Z","timestamp":1793505396672,"version":"4.5.0"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>The ION system is a shape-sensing robotic-assisted bronchoscopy (SS-RAB) platform developed to biopsy peripheral pulmonary nodules (PPNs). There is a lack of data describing the use of this system in the Chinese population. The study aimed to assess the feasibility and safety of using SS-RAB to diagnose PPNs across multiple centers within China.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This prospective, multicenter study used SS-RAB in consecutive patients with solid or sub-solid PPNs 8 to 30\u00a0mm in largest diameter. Primary endpoints were diagnostic yield and the rates of procedure- or device-related complications. Radial endobronchial ultrasound (rEBUS) was to confirm lesion localization, followed by sampling, using the Flexision biopsy needle, biopsy forceps, and cytology brush. Subjects with nonmalignant index biopsy results were followed up to 6 months.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of 90 PPNs were biopsied from 90 subjects across 3 centers using SS-RAB. The median nodule size was 19.4\u00a0mm (IQR: 19.3, 24.6) in the largest dimension. In all (100%) cases, the catheter successfully reached the target nodule with tissue samples obtained. The diagnostic yield was 87.8% with a sensitivity for malignancy of 87.7% (71\/81). In a univariate analysis, nodule lobar location, presence of bronchus sign, and rEBUS view were associated with a diagnostic sample, but only rEBUS view showed an association in a multivariate analysis. The overall pneumothorax rate was 1.1% without pneumothorax requiring intervention, and there was no periprocedural bleeding.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>As an emerging technology in the Chinese population, SS-RAB can safely biopsy PPNs with strong diagnostic performance.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/lbr.0000000000000981","type":"journal-article","created":{"date-parts":[[2024,8,8]],"date-time":"2024-08-08T12:00:59Z","timestamp":1723118459000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":22,"title":["Shape-sensing Robotic-assisted Bronchoscopy (SS-RAB) in Sampling Peripheral Pulmonary Nodules"],"prefix":"10.1097","volume":"31","author":[{"given":"Fangfang","family":"Xie","sequence":"first","affiliation":[{"name":"Department of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine"},{"name":"Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Quncheng","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Respiratory and Critical Care Medicine, Zhengzhou University People\u2019s Hospital, Henan Provincial People\u2019s Hospital, Zhengzhou"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuanyong","family":"Mu","sequence":"additional","affiliation":[{"name":"Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qin","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine"},{"name":"Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huizhen","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Respiratory and Critical Care Medicine, Zhengzhou University People\u2019s Hospital, Henan Provincial People\u2019s Hospital, Zhengzhou"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingyu","family":"Mao","sequence":"additional","affiliation":[{"name":"Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Simoff","sequence":"additional","affiliation":[{"name":"Bronchoscopy and Interventional Pulmonology, Lung Cancer Screening Program, Department of Pulmonary and Critical Care Medicine, Henry Ford Hospital, Wayne State University School of Medicine, Detroit, MI"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian\u2019an","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Soochow University, Suzhou, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoju","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Respiratory and Critical Care Medicine, Zhengzhou University People\u2019s Hospital, Henan Provincial People\u2019s Hospital, Zhengzhou"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiayuan","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Respiratory Endoscopy, Department of Respiratory and Critical Care Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine"},{"name":"Shanghai Engineering Research Center of Respiratory Endoscopy, Shanghai"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,10]]},"reference":[{"key":"R1-20240809","doi-asserted-by":"crossref","first-page":"209","DOI":"10.3322\/caac.21660","article-title":"Global cancer statistics 2020: Globocan estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"71","author":"Sung","year":"2021","journal-title":"CA Cancer J Clin"},{"key":"R2-20240809","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1038\/s41571-020-00432-6","article-title":"Lung cancer ldct screening and mortality reduction\u2014evidence, pitfalls and future perspectives","volume":"18","author":"Oudkerk","year":"2021","journal-title":"Nat Rev Clin Oncol"},{"key":"R3-20240809","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1056\/NEJMoa1911793","article-title":"Reduced lung-cancer mortality with volume CT screening in a randomized trial","volume":"382","author":"de Koning","year":"2020","journal-title":"N Engl J Med"},{"key":"R4-20240809","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.1016\/j.chest.2022.12.044","article-title":"Guided bronchoscopy for the evaluation of pulmonary lesions: an updated meta-analysis","volume":"163","author":"Nadig","year":"2023","journal-title":"Chest"},{"key":"R5-20240809","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.athoracsur.2021.06.086","article-title":"Ion: Technology and techniques for shape-sensing robotic-assisted bronchoscopy","volume":"113","author":"Reisenauer","year":"2022","journal-title":"Ann Thorac Surg"},{"key":"R6-20240809","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1159\/000498951","article-title":"First human use of a new robotic-assisted fiber optic sensing navigation system for small peripheral pulmonary nodules","volume":"98","author":"Fielding","year":"2019","journal-title":"Respiration"},{"key":"R7-20240809","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s00408-021-00421-1","article-title":"Robotic-assisted navigation bronchoscopy as a paradigm shift in peripheral lung access","volume":"199","author":"Benn","year":"2021","journal-title":"Lung"},{"key":"R8-20240809","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.chest.2021.07.2169","article-title":"Shape-sensing robotic-assisted bronchoscopy in the diagnosis of pulmonary parenchymal lesions","volume":"161","author":"Kalchiem-Dekel","year":"2022","journal-title":"Chest"},{"key":"R9-20240809","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1016\/j.athoracsur.2022.11.022","article-title":"Accuracy of preliminary pathology for robotic bronchoscopic biopsy","volume":"116","author":"Vu","year":"2023","journal-title":"Ann Thorac Surg"},{"key":"R10-20240809","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.mayocpiqo.2022.02.004","article-title":"Combining shape-sensing robotic bronchoscopy with mobile three-dimensional imaging to verify tool-in-lesion and overcome divergence: a pilot study","volume":"6","author":"Reisenauer","year":"2022","journal-title":"Mayo Clin Proc Innov Qual Outcomes"},{"key":"R11-20240809","doi-asserted-by":"crossref","first-page":"1426","DOI":"10.1016\/j.chest.2021.08.074","article-title":"The impact of alternative approaches to diagnostic yield calculation in studies of bronchoscopy","volume":"161","author":"Vachani","year":"2022","journal-title":"Chest"},{"key":"R12-20240809","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.chest.2020.08.2047","article-title":"Robotic bronchoscopy for peripheral pulmonary lesions: a multicenter pilot and feasibility study (benefit)","volume":"159","author":"Chen","year":"2021","journal-title":"Chest"},{"key":"R13-20240809","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1016\/j.athoracsur.2021.12.041","article-title":"Factors associated with diagnostic accuracy of robotic bronchoscopy with 12-month follow-up","volume":"115","author":"Agrawal","year":"2023","journal-title":"Ann Thorac Surg"},{"key":"R15-20240809","doi-asserted-by":"crossref","first-page":"3279","DOI":"10.21037\/jtd.2020.03.35","article-title":"Robotic bronchoscopy for pulmonary lesions: a review of existing technologies and clinical data","volume":"12","author":"Agrawal","year":"2020","journal-title":"J Thorac Dis"},{"key":"R16-20240809","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/j.jtho.2021.12.008","article-title":"Navigate 24-month results: electromagnetic navigation bronchoscopy for pulmonary lesions at 37 centers in europe and the united states","volume":"17","author":"Folch","year":"2022","journal-title":"J Thorac Oncol"},{"key":"R17-20240809","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.1513\/AnnalsATS.202109-1071OC","article-title":"A novel electromagnetic navigation bronchoscopy system for the diagnosis of peripheral pulmonary nodules: a randomized clinical trial","volume":"19","author":"Zheng","year":"2022","journal-title":"Ann Am Thorac Soc"},{"key":"R18-20240809","doi-asserted-by":"crossref","first-page":"1197","DOI":"10.1136\/thorax-2022-219664","article-title":"Novel electromagnetic navigation bronchoscopy system for the diagnosis of peripheral pulmonary nodules: a prospective, multicentre study","volume":"78","author":"Li","year":"2023","journal-title":"Thorax"},{"key":"R19-20240809","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.3390\/diagnostics13061049","article-title":"The use of robotic-assisted bronchoscopy in the diagnostic evaluation of peripheral pulmonary lesions: a paradigm shift","volume":"13","author":"Hammad Altaq","year":"2023","journal-title":"Diagnostics"},{"key":"R20-20240809","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1513\/AnnalsATS.201711-856OC","article-title":"Computed tomography bronchus sign and the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions. A systematic review and meta-analysis","volume":"15","author":"Ali","year":"2018","journal-title":"Ann Am Thorac Soc"},{"key":"R21-20240809","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1164\/rccm.201507-1332OC","article-title":"Diagnostic yield and complications of bronchoscopy for peripheral lung lesions. Results of the aquire registry","volume":"193","author":"Ost","year":"2016","journal-title":"Am J Respir Crit Care Med"},{"key":"R22-20240809","doi-asserted-by":"crossref","first-page":"1801","DOI":"10.1513\/AnnalsATS.202301-075OC","article-title":"Diagnostic performance and safety profile of robotic-assisted bronchoscopy: a systematic review and meta-analysis","volume":"20","author":"Ali","year":"2023","journal-title":"Ann Am Thorac Soc"},{"key":"R23-20240809","doi-asserted-by":"crossref","first-page":"e326","DOI":"10.1016\/j.chest.2021.04.075","article-title":"Robotic bronchoscopy for diagnosing peripheral lung lesions: Are we there yet?","volume":"160","author":"Kramer","year":"2021","journal-title":"Chest"},{"key":"R24-20240809","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1159\/000522516","article-title":"Robotic assisted bronchoscopy: the ultimate solution for peripheral pulmonary nodules?","volume":"101","author":"van der Heijden","year":"2022","journal-title":"Respiration"},{"key":"R25-20240809","doi-asserted-by":"crossref","first-page":"6950","DOI":"10.21037\/jtd.2018.11.21","article-title":"Cone beam computed tomography-guided thin\/ultrathin bronchoscopy for diagnosis of peripheral lung nodules: a prospective pilot study","volume":"10","author":"Casal","year":"2018","journal-title":"J Thorac Dis"},{"key":"R26-20240809","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1136\/thoraxjnl-2021-216885","article-title":"Bronchoscopic needle-based confocal laser endomicroscopy (ncle) as a real-time detection tool for peripheral lung cancer","volume":"77","author":"Kramer","year":"2022","journal-title":"Thorax"},{"key":"R27-20240809","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1111\/resp.14438","article-title":"Robotic bronchoscopic needle-based confocal laser endomicroscopy to diagnose peripheral lung nodules","volume":"28","author":"Manley","year":"2023","journal-title":"Respirology"},{"key":"R28-20240809","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1007\/s00408-022-00578-3","article-title":"Novel robotic-assisted cryobiopsy for peripheral pulmonary lesions","volume":"200","author":"Oberg","year":"2022","journal-title":"Lung"},{"key":"R29-20240809","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1097\/LBR.0000000000000936","article-title":"A cone beam CT bronchoscopy study of the ultrathin cryoprobe for biopsy of peripheral lung lesions","volume":"31","author":"Bhadra","year":"2024","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R30-20240809","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1378\/chest.11-1764","article-title":"Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule","volume":"142","author":"Wang Memoli","year":"2012","journal-title":"Chest"},{"key":"R31-20240809","doi-asserted-by":"crossref","first-page":"20170805","DOI":"10.1259\/bjr.20170805","article-title":"Cone beam computed tomography virtual navigation-guided transthoracic biopsy of small (\u22641 cm) pulmonary nodules: impact of nodule visibility during real-time fluoroscopy","volume":"91","author":"Hwang","year":"2018","journal-title":"Br J Radiol"},{"key":"R32-20240809","doi-asserted-by":"crossref","first-page":"1963","DOI":"10.21037\/tlcr-20-957","article-title":"A pilot study of the ultrathin cryoprobe in the diagnosis of peripheral pulmonary ground-glass opacity lesions","volume":"9","author":"Jiang","year":"2020","journal-title":"Transl Lung Cancer Res"},{"key":"R33-20240809","doi-asserted-by":"crossref","first-page":"1656","DOI":"10.1016\/j.chest.2019.12.024","article-title":"An evaluation of diagnostic yield from bronchoscopy: the impact of clinical\/radiographic factors, procedure type, and degree of suspicion for cancer","volume":"157","author":"Silvestri","year":"2020","journal-title":"Chest"},{"key":"R34-20240809","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1111\/resp.14405","article-title":"Virtual bronchoscopic navigation and endobronchial ultrasound with a guide sheath without fluoroscopy for diagnosing peripheral pulmonary lesions with a bronchus leading to or adjacent to the lesion: a randomized non-inferiority trial","volume":"28","author":"Zheng","year":"2022","journal-title":"Respirology"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000981","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T15:25:12Z","timestamp":1723217112000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000000981"}},"subtitle":["A Prospective, Multicenter Clinical Feasibility Study in China"],"short-title":[],"issued":{"date-parts":[[2024,8,8]]},"references-count":33,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000000981","relation":{},"ISSN":["1948-8270"],"issn-type":[{"value":"1948-8270","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,8]]},"assertion":[{"value":"2024-01-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-06-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}