{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T03:05:44Z","timestamp":1777950344425,"version":"3.51.4"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Recent growth of navigational bronchoscopy has included use of new platforms and tools, the benefit of which remains under study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Research Question:<\/jats:title>\n                    <jats:p>Does diagnostic yield differ between: (a) electromagnetic navigation bronchoscopy versus shape-sensing robotic-assisted bronchoscopy; (b) ssRAB versus ssRAB with cone-beam CT (ssRAB-CBCT); and (c) nodule sampling with versus without cryobiopsy?<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This single-center retrospective study evaluated the diagnostic performance of navigational bronchoscopy cases with acquisition of new platforms and tools at a bronchoscopy referral center between 2016 and March 2024. Diagnostic yield was evaluated for the primary procedural target, with yield defined as per ATS\/ACCP guidelines.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 185 ENB cases, 371 ssRAB cases, and 54 ssRAB-CBCT cases were available for comparison. Diagnostic yield was 57% for ENB, 72% for ssRAB and 78% for ssRAB-CBCT (ENB vs. ssRAB\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.001; ssRAB vs. ssRAB-CBCT\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.307). Diagnostic yield was 78% for ssRAB\/ssRAB-CBCT procedures that used cryobiopsy versus 69% for procedures that did not (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.035). Nodule size differed between procedure types: median size 27\u00a0mm (IQR 17 to 35\u00a0mm) for ENB, 21\u00a0mm (IQR 16 to 30\u00a0mm) for ssRAB (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.001 for ENB vs. ssRAB), and 17\u00a0mm (IQR 13 to 25) for ssRAB-CBCT (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.004 for ssRAB vs. ssRAB-CBCT). Differences were found between ENB and ssRAB procedures regarding nodule location in the peripheral third of lung (ENB 50% vs. ssRAB 62%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.009) and presence of a bronchus sign (ENB 81% vs. ssRAB 43%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =&lt;0.001), whereas other nodule characteristics were similar between groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Acquisition of new tools for navigational bronchoscopy was associated with increased diagnostic yield despite performing biopsies on increasingly difficult cases.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/lbr.0000000000001071","type":"journal-article","created":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T07:00:54Z","timestamp":1777878054000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Evolution of Diagnostic Yield for Peripheral Lung Nodule Biopsies With Changes in Navigational Bronchoscopy Platforms, Tools, and Intraoperative Imaging Guidance"],"prefix":"10.1097","volume":"33","author":[{"given":"Jason","family":"Beattie","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raymond","family":"Parrish","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1582-5809","authenticated-orcid":false,"given":"Paula","family":"Aranguren","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laith","family":"Ayasa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annika","family":"Bharwani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alma","family":"Burbano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fahim","family":"Pyarali","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alex","family":"Chee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenchen","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fayez","family":"Kheir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai","family":"Swenson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mihir","family":"Parikh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adnan","family":"Majid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2026,7]]},"reference":[{"key":"R1-20260504","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.chest.2021.07.2169","article-title":"Shape-sensing robotic-assisted bronchoscopy in the diagnosis of pulmonary parenchymal lesions","volume":"161","author":"Kalchiem-Dekel","year":"2022","journal-title":"Chest"},{"key":"R2-20260504","first-page":"445","article-title":"Electromagnetic navigation bronchoscopy for peripheral pulmonary lesions: one-year results of the prospective, multicenter NAVIGATE study","volume":"14","author":"Folch","year":"2019","journal-title":"J Thorac Oncol Off Publ Int Assoc Study Lung Cancer"},{"key":"R3-20260504","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1016\/j.chest.2018.08.1026","article-title":"Standard bronchoscopy with fluoroscopy vs thin bronchoscopy and radial endobronchial ultrasound for biopsy of pulmonary lesions: a multicenter, prospective, randomized trial","volume":"154","author":"Tanner","year":"2018","journal-title":"Chest"},{"key":"R4-20260504","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1186\/s12890-019-1010-8","article-title":"Robot-assisted bronchoscopy for pulmonary lesion diagnosis: results from the initial multicenter experience","volume":"19","author":"Chaddha","year":"2019","journal-title":"BMC Pulm Med"},{"key":"R5-20260504","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1097\/LBR.0000000000000536","article-title":"Cone-beam CT with augmented fluoroscopy combined with electromagnetic navigation bronchoscopy for biopsy of pulmonary nodules","volume":"25","author":"Pritchett","year":"2018","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R6-20260504","first-page":"214","article-title":"High accuracy of digital tomosynthesis-guided bronchoscopic biopsy confirmed by intraprocedural computed tomography","volume":"100","author":"Katsis","year":"2021","journal-title":"Respir Int Rev Thorac Dis"},{"key":"R7-20260504","doi-asserted-by":"crossref","first-page":"6950","DOI":"10.21037\/jtd.2018.11.21","article-title":"Cone beam computed tomography-guided thin\/ultrathin bronchoscopy for diagnosis of peripheral lung nodules: a prospective pilot study","volume":"10","author":"Casal","year":"2018","journal-title":"J Thorac Dis"},{"key":"R8-20260504","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1097\/LBR.0000000000000949","article-title":"Cone-beam CT-based navigation with augmented fluoroscopy of the airways for image-guided bronchoscopic biopsy of peripheral pulmonary nodules: a prospective clinical study","volume":"31","author":"Pritchett","year":"2024","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R9-20260504","first-page":"44","article-title":"Cone-beam computed tomography-guided electromagnetic navigation for peripheral lung nodules","volume":"100","author":"Kheir","year":"2021","journal-title":"Respir Int Rev Thorac Dis"},{"key":"R10-20260504","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1186\/s12890-022-02003-0","article-title":"Diagnostic value of a new cryoprobe for peripheral pulmonary lesions: a prospective study","volume":"22","author":"Tanaka","year":"2022","journal-title":"BMC Pulm Med"},{"key":"R11-20260504","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1007\/s00408-022-00578-3","article-title":"Novel robotic-assisted cryobiopsy for peripheral pulmonary lesions","volume":"200","author":"Oberg","year":"2022","journal-title":"Lung"},{"key":"R12-20260504","doi-asserted-by":"crossref","first-page":"2175","DOI":"10.21037\/tlcr-24-304","article-title":"Diagnostic efficacy of cryobiopsy for peripheral pulmonary lesions with ground-glass opacity: a propensity score-matched analysis","volume":"13","author":"Furuse","year":"2024","journal-title":"Transl Lung Cancer Res"},{"key":"R14-20260504","doi-asserted-by":"crossref","first-page":"106966","DOI":"10.1016\/j.rmed.2022.106966","article-title":"Does transbronchial lung cryobiopsy improve diagnostic yield of digital tomosynthesis-assisted electromagnetic navigation guided bronchoscopic biopsy of pulmonary nodules? A pilot study","volume":"202","author":"Benn","year":"2022","journal-title":"Respir Med"},{"key":"R16-20260504","doi-asserted-by":"crossref","first-page":"5529","DOI":"10.21037\/jtd-24-178","article-title":"Cone-beam computed tomography-guided shape-sensing robotic bronchoscopy vs. electromagnetic navigation bronchoscopy for pulmonary nodules","volume":"16","author":"Abdelghani","year":"2024","journal-title":"J Thorac Dis"},{"key":"R17-20260504","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1016\/j.chest.2022.10.019","article-title":"Shape-sensing robotic-assisted bronchoscopy vs digital tomosynthesis-corrected electromagnetic navigation bronchoscopy: a comparative cohort study of diagnostic performance","volume":"163","author":"Low","year":"2023","journal-title":"Chest"},{"key":"R19-20260504","doi-asserted-by":"crossref","DOI":"10.1186\/s13063-023-07863-3","article-title":"Robotic versus Electromagnetic bronchoscopy for pulmonary LesIon AssessmeNT: the RELIANT pragmatic randomized trial","author":"Paez","year":"2024","journal-title":"Trials"},{"key":"R20-20260504","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1164\/rccm.202401-0192ST","article-title":"Assessment of Advanced Diagnostic Bronchoscopy Outcomes for Peripheral Lung Lesions: A Delphi Consensus Definition of Diagnostic Yield and Recommendations for Patient-centered Study Designs. An Official American Thoracic Society\/American College of Chest Physicians Research Statement","volume":"209","author":"Gonzalez","year":"2024","journal-title":"Am J Respir Crit Care Med"},{"key":"R21-20260504","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1378\/chest.117.4.1049","article-title":"Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules","volume":"117","author":"Baaklini","year":"2000","journal-title":"Chest"},{"key":"R22-20260504","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.chest.2020.08.2047","article-title":"Robotic bronchoscopy for peripheral pulmonary lesions: a multicenter pilot and feasibility study (BENEFIT)","volume":"159","author":"Chen","year":"2021","journal-title":"Chest"},{"key":"R23-20260504","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1186\/s12890-023-02465-w","article-title":"Diagnostic outcomes of robotic-assisted bronchoscopy for pulmonary lesions in a real-world multicenter community setting","volume":"23","author":"Khan","year":"2023","journal-title":"BMC Pulm Med"},{"key":"R25-20260504","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1007\/s00408-022-00590-7","article-title":"Shape-sensing robotic-assisted bronchoscopy with concurrent use of radial endobronchial ultrasound and cone beam computed tomography in the evaluation of pulmonary lesions","volume":"200","author":"Styrvoky","year":"2022","journal-title":"Lung"},{"key":"R26-20260504","doi-asserted-by":"crossref","first-page":"A1622","DOI":"10.1016\/j.chest.2021.07.1479","article-title":"Integration of shape-sensing robotic-assisted bronchoscopy and cone-beam ct for the biopsy of pulmonary nodules","volume":"160","author":"Pritchett","year":"2021","journal-title":"Chest"},{"key":"R27-20260504","doi-asserted-by":"crossref","first-page":"e0971","DOI":"10.1097\/LBR.0000000000000971","article-title":"Added value of a robotic-assisted bronchoscopy platform in cone beam computed tomography-guided bronchoscopy for the diagnosis of pulmonary parenchymal lesions","volume":"31","author":"Shaller","year":"2024","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R28-20260504","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1016\/j.chest.2021.05.015","article-title":"Diagnostic outcomes and safety of cryobiopsy added to conventional sampling methods: an observational study","volume":"160","author":"Matsumoto","year":"2021","journal-title":"Chest"},{"issue":"Suppl 68","key":"R30-20260504","first-page":"OA4681","article-title":"Diagnostic yield of ssRAB combined with CBCT imaging in comparison with CBCT-based navigation bronchoscopy using a passive catheter-based approach: preliminary results","volume":"64","author":"Bruinen","year":"2024","journal-title":"Eur Respir J [Internet]"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000001071","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T07:00:56Z","timestamp":1777878056000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/LBR.0000000000001071"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,4]]},"references-count":25,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000001071","relation":{},"ISSN":["1948-8270"],"issn-type":[{"value":"1948-8270","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,4]]},"assertion":[{"value":"2025-03-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-04","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}