{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T08:25:45Z","timestamp":1786955145456,"version":"build-2736575974"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The comparative sampling efficacy of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) needles in mediastinal lymphadenopathy remains unclear. Would the fine needle biopsy (FNB), with its Franseen design, provide better results than the fine needle aspiration (FNA) during EBUS-TBNA?<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>We performed a single-center, investigator-initiated, single-blinded, randomized, parallel-group, superiority trial between August 2022 and July 2023. Consecutive patients were randomly assigned (1:1) to undergo EBUS-TBNA with either 19-gauge (G) FNA or 22-G FNB. The primary endpoint was the diagnostic yield, while the secondary endpoints were specimen adequacy and complication rates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The study included 150 patients with a mean age of 44.5\u00b115.1 years (50.7% female patients). The diagnostic yield of FNB was not significantly different from FNA (94.7% vs. 89.3%; difference, 5.4%; 95% CI: \u22124.0% to 15.0%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.23). Despite this, FNB had a higher rate of adequate tissue (98.6% vs. 86.7%; difference, 11.9%; 95% CI: 4.0%-22.0%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001) and larger core tissue (11.52 vs. 9.29\u00a0mm; mean difference, 2.23\u00a0mm; 95% CI: 1.4-3.1mm;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001) than FNA. FNB showed a significantly higher diagnostic yield for histologic samples (90.7% vs. 76.0%; difference, 14.7%; 95% CI: 3.0-27.0;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.016) in post hoc analysis; however, this should be considered a hypothesis-generating finding. All procedures were well tolerated except for minor bleeding.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Despite similar diagnostic yields, FNB was more effective than FNA in providing larger, adequate core tissue samples. This improvement in specimen quality may suggest a potential clinical benefit for comprehensive diagnosis and advanced pathologic work-up.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/lbr.0000000000001085","type":"journal-article","created":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T08:00:06Z","timestamp":1786953606000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Endobronchial Ultrasound-Guided Fine Needle Biopsy in the Diagnosis of Mediastinal Lymphadenopathy"],"prefix":"10.1097","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4727-3554","authenticated-orcid":false,"given":"Ajmal","family":"Khan","sequence":"first","affiliation":[{"name":"\u200b\u200b\u200b\u200b\u200bPulmonary Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atul","family":"Tiwari","sequence":"additional","affiliation":[{"name":"\u200b\u200b\u200b\u200b\u200bPulmonary Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mansi","family":"Gupta","sequence":"additional","affiliation":[{"name":"\u200b\u200b\u200b\u200b\u200bPulmonary Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zia","family":"Hashim","sequence":"additional","affiliation":[{"name":"\u200b\u200b\u200b\u200b\u200bPulmonary Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alok","family":"Nath","sequence":"additional","affiliation":[{"name":"\u200b\u200b\u200b\u200b\u200bPulmonary Medicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vinita","family":"Agrawal","sequence":"additional","affiliation":[{"name":"Pathology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ojas","family":"Gupta","sequence":"additional","affiliation":[{"name":"Pathology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anup","family":"Kumar","sequence":"additional","affiliation":[{"name":"Biostatics and Health Informatics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, UP, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,17]]},"reference":[{"key":"R2-20260817","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1183\/09031936.06.00124905","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration of lymph nodes in the radiologically normal mediastinum","volume":"28","author":"Herth","year":"2006","journal-title":"Eur Respir J"},{"key":"R3-20260817","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.lungcan.2005.07.013","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer","volume":"50","author":"Yasufuku","year":"2005","journal-title":"Lung Cancer"},{"key":"R4-20260817","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.rmed.2012.02.014","article-title":"Efficacy and safety of convex probe EBUS-TBNA in sarcoidosis: a systematic review and meta-analysis","volume":"106","author":"Agarwal","year":"2012","journal-title":"Respir Med"},{"key":"R5-20260817","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1513\/AnnalsATS.201902-175OC","article-title":"Diagnostic accuracy of endobronchial ultrasound transbronchial needle aspiration in lymphoma. A systematic review and meta-analysis","volume":"16","author":"Labarca","year":"2019","journal-title":"Ann Am Thorac Soc"},{"key":"R6-20260817","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s42399-022-01379-8","article-title":"The diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) Technique in assessment of mediastinal lymph nodes","volume":"5","author":"Rafieian","year":"2022","journal-title":"SN Comprehensive Clinical Medicine"},{"key":"R7-20260817","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/LBR.0000000000000515","article-title":"Comparison of sample adequacy and diagnostic yield of 19- and 22-G EBUS-TBNA needles","volume":"25","author":"Chaddha","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R8-20260817","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1378\/chest.12-1205","article-title":"Comparison of 21-gauge and 22-gauge aspiration needle in endobronchial ultrasound-guided transbronchial needle aspiration: results of the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation Registry","volume":"143","author":"Yarmus","year":"2013","journal-title":"Chest"},{"key":"R9-20260817","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1111\/crj.13436","article-title":"Comparing diagnostic sensitivity of different needle sizes for lymph nodes suspected of lung cancer in endobronchial ultrasound transbronchial needle aspiration: Systematic review and meta-analysis","volume":"15","author":"Yu Lee-Mateus","year":"2021","journal-title":"Clin Respir J"},{"key":"R10-20260817","doi-asserted-by":"crossref","first-page":"99","DOI":"10.4103\/eus.eus_53_17","article-title":"A multicenter evaluation of a new EUS core biopsy needle: Experience in 200 patients","volume":"8","author":"Adler","year":"2019","journal-title":"Endosc Ultrasound"},{"key":"R11-20260817","doi-asserted-by":"crossref","first-page":"576","DOI":"10.5946\/ce.2018.053","article-title":"Prospective assessment of the performance of a new fine needle biopsy device for EUS-guided sampling of solid lesions","volume":"51","author":"El","year":"2018","journal-title":"Clin Endosc"},{"key":"R12-20260817","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.jasc.2020.04.009","article-title":"Core needle biopsy with endobronchial ultrasonography: single center experience with 100 cases","volume":"9","author":"Balwan","year":"2020","journal-title":"J Am Soc Cytopathol"},{"key":"R13-20260817","doi-asserted-by":"crossref","first-page":"107362","DOI":"10.1016\/j.lungcan.2023.107362","article-title":"Endobronchial ultrasound in diagnosing and staging of lung cancer by Acquire 22G TBNB versus regular 22G TBNA needles: a randomized clinical trial","volume":"185","author":"Kramer","year":"2023","journal-title":"Lung Cancer"},{"key":"R14-20260817","doi-asserted-by":"crossref","first-page":"1282","DOI":"10.1093\/jjco\/hyaf124","article-title":"Utility of ultrasound-guided transbronchial needle biopsy using an acquire needle in the diagnosis of chest and mediastinal diseases","volume":"55","author":"Minami","year":"2025","journal-title":"Jpn J Clin Oncol"},{"key":"R15-20260817","doi-asserted-by":"crossref","first-page":"e081123","DOI":"10.1136\/bmj-2024-081123","article-title":"CONSORT 2025 statement: updated guideline for reporting randomized trials","volume":"389","author":"Hopewell","year":"2025","journal-title":"Brit Med J"},{"key":"R17-20260817","doi-asserted-by":"crossref","first-page":"933","DOI":"10.5858\/arpa.2020-0119-CP","article-title":"Collection and handling of thoracic small biopsy and cytology specimens for ancillary studies: guideline from the College of American Pathologists in Collaboration with the American College of Chest Physicians, Association for Molecular Pathology, American Society of Cytopathology, American Thoracic Society, Pulmonary Pathology Society, Papanicolaou Society of Cytopathology, Society of Interventional Radiology, and Society of Thoracic Radiology","volume":"144","author":"Roy-Chowdhuri","year":"2020","journal-title":"Arch Pathol Lab Med"},{"key":"R18-20260817","doi-asserted-by":"crossref","first-page":"e26","DOI":"10.1164\/rccm.202002-0251ST","article-title":"Diagnosis and detection of sarcoidosis. An Official American Thoracic Society clinical practice guideline","volume":"201","author":"Crouser","year":"2020","journal-title":"Am J Respir Crit Care Med"},{"key":"R19-20260817","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/LBR.0000000000000500","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration with a 19-G needle device","volume":"25","author":"Tremblay","year":"2018","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R20-20260817","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1097\/LBR.0000000000000674","article-title":"Evaluating Yield of 19 versus 21G EBUS-TBNA needles: a prospective study","volume":"28","author":"Elmufdi","year":"2021","journal-title":"J Bronchology Interv Pulmonol"},{"key":"R21-20260817","doi-asserted-by":"crossref","first-page":"368","DOI":"10.4103\/lungindia.lungindia_510_22","article-title":"Guidelines for endobronchial ultrasound-transbronchial needle aspiration (EBUS-TBNA): Joint Indian Chest Society (ICS)\/Indian Association for Bronchology (IAB) recommendations","volume":"40","author":"Mohan","year":"2023","journal-title":"Lung India"},{"key":"R22-20260817","doi-asserted-by":"crossref","first-page":"107131","DOI":"10.1016\/j.rmed.2023.107131","article-title":"Endobronchial ultrasound bronchoscopy Franseen fine needle biopsy tool versus standard fine needle aspiration needle: Impact on diagnosis and tissue adequacy","volume":"208","author":"Aboudara","year":"2023","journal-title":"Respir Med"},{"key":"R23-20260817","doi-asserted-by":"crossref","first-page":"3273","DOI":"10.21037\/jtd-22-1747","article-title":"First Asia-Pacific experience of trans-bronchial core biopsy with a Franseen needle","volume":"15","author":"Brown","year":"2023","journal-title":"J Thorac Dis"},{"key":"R24-20260817","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.lungcan.2022.01.018","article-title":"A systematic review and meta-analysis of the adequacy of endobronchial ultrasound transbronchial needle aspiration for next-generation sequencing in patients with non-small cell lung cancer","volume":"166","author":"Zhao","year":"2022","journal-title":"Lung Cancer"},{"key":"R25-20260817","doi-asserted-by":"crossref","first-page":"e15502","DOI":"10.1111\/1759-7714.15502","article-title":"Feasibility of endobronchial ultrasound-guided miniforceps biopsy for PD-L1 expression and quantitative tissue analysis","volume":"16","author":"Wayne","year":"2025","journal-title":"Thorac Cancer"},{"key":"R26-20260817","doi-asserted-by":"crossref","first-page":"1637","DOI":"10.3390\/jcm14051637","article-title":"Real-life comparison of diagnostic yield and sample adequacy of 22 G and 25 G EBUS-TBNB needles: a retrospective study","volume":"14","author":"Lanfranchi","year":"2025","journal-title":"J Clin Med"},{"key":"R27-20260817","doi-asserted-by":"crossref","first-page":"3643","DOI":"10.21037\/jtd.2019.04.20","article-title":"Comparison of specimen adequacy and diagnostic accuracy of a 25-gauge and 22-gauge needle in endobronchial ultrasound-guided transbronchial needle aspiration","volume":"11","author":"Di Felice","year":"2019","journal-title":"J Thorac Dis"},{"key":"R28-20260817","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1080\/17434440.2024.2410913","article-title":"Utility of acquire 22G-fine needle biopsy (FNB) needle vs the standard 22G needle during Endobronchial Ultrasound-guided Transbronchial Needle Aspiration (EBUS-TBNA): a randomized controlled trial (RCT)","volume":"21","author":"Madan","year":"2024","journal-title":"Expert Rev Med Devices"},{"key":"R29-20260817","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1093\/jjco\/hyae077","article-title":"Franseen needle in endobronchial ultrasound-guided transbronchial needle aspiration: a phase II prospective study","volume":"54","author":"Shikano","year":"2024","journal-title":"Jpn J Clin Oncol"},{"key":"R30-20260817","doi-asserted-by":"crossref","first-page":"5879","DOI":"10.3390\/cancers13235879","article-title":"The impact of core tissues on successful next-generation sequencing analysis of specimens obtained through endobronchial ultrasound-guided transbronchial needle aspiration","volume":"13","author":"Uchimura","year":"2021","journal-title":"Cancers (Basel)"}],"container-title":["Journal of Bronchology &amp; Interventional Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/LBR.0000000000001085","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T08:00:10Z","timestamp":1786953610000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/LBR.0000000000001085"}},"subtitle":["A Randomized Trial"],"short-title":[],"issued":{"date-parts":[[2026,8,17]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/lbr.0000000000001085","relation":{},"ISSN":["1948-8270"],"issn-type":[{"value":"1948-8270","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,17]]},"assertion":[{"value":"2025-11-21","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}