{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,21]],"date-time":"2026-11-21T00:37:12Z","timestamp":1795221432020,"version":"4.10.3"},"reference-count":6,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:sec>\n            <jats:title>Hypothesis:<\/jats:title>\n            <jats:p>Audio processor magnets used in transcutaneous active hearing implants vary in retention force. We hypothesized that a range of optimal magnetic retention forces could be derived, based on objective in-situ measurements of individual retention forces.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>The magnetic force required to retain the proper placement of transcutaneous active hearing implants varies among patients. Currently, audiologists rely on personal experience in deciding which magnet to use. Insufficient force causes frequent loss of the single-unit processors or external coils of behind-the-ear devices, and excessive force causes pain and skin irritations.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>We experimentally determined magnetic retention force as a function of the distance between two magnets for different processor-implant magnet combinations. In addition, we studied individual in situ retention forces in 100 patients with hearing devices. Skin status was evaluated by a physician and assessed by patient self-reporting and a questionnaire.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Force\u2013distance functions showed that different magnet strengths had differential effects only at distances less than 6\u200amm. Examiner and patient skin status assessments and comfort scores showed that optimal retention force range was 0.23 to 0.4\u200aN.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>We found that the currently available magnet types restrict the range of feasible skin flap thicknesses to a maximum of 6\u200amm. Further we conclude that retention forces between 0.23 and 0.4\u200aN could provide the appropriate trade-off between the risk of losing device fixation and of causing skin irritations. We recommend measuring the retention force in all patients.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/mao.0000000000002201","type":"journal-article","created":{"date-parts":[[2019,4,27]],"date-time":"2019-04-27T10:54:17Z","timestamp":1556362457000},"page":"e482-e487","source":"Crossref","is-referenced-by-count":17,"title":["Optimal Retention Force of Audio Processor Magnets"],"prefix":"10.1097","volume":"40","author":[{"given":"Luise","family":"Wagner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elisabeth","family":"H\u00f6nig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Fr\u00f6hlich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Plontke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Torsten","family":"Rahne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230821","first-page":"148","article-title":"Skin flap thickness in cochlear implant patients - a prospective study","volume":"8","author":"Raine","year":"2007","journal-title":"Cochlear Implants Int"},{"key":"R3-20230821","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1097\/WON.0000000000000281","article-title":"Revised national pressure ulcer advisory panel pressure injury staging system: revised pressure injury staging system","volume":"43","author":"Edsberg","year":"2016","journal-title":"J Wound Ostomy Continence Nurs"},{"key":"R4-20230821","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1097\/AUD.0b013e3181645366","article-title":"Benefit of the vibrant soundbridge device in patients implanted for 5 to 8 years","volume":"29","author":"Mosnier","year":"2008","journal-title":"Ear Hear"},{"key":"R5-20230821","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1007\/s00405-016-4361-2","article-title":"Systematic review to evaluate the safety, efficacy and economical outcomes of the Vibrant Soundbridge for the treatment of sensorineural hearing loss","volume":"274","author":"Bruchhage","year":"2017","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R6-20230821","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1679\/aohc.71.303","article-title":"Comparison between a weight compression and a magnet compression for experimental pressure ulcers in the rat. Histological studies and effects of anesthesia","volume":"71","author":"Hashimoto","year":"2008","journal-title":"Arch Histol Cytol"},{"key":"R8-20230821","doi-asserted-by":"crossref","first-page":"413","DOI":"10.2147\/MDER.S90704","article-title":"Magnetic resonance imaging investigation of the bone conduction implant - a pilot study at 1.5 Tesla","volume":"8","author":"Fred\u00e9n Jansson","year":"2015","journal-title":"Med Devices"}],"container-title":["Otology &amp; Neurotology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00129492-201906000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T22:22:26Z","timestamp":1692656546000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00129492-201906000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6]]},"references-count":6,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/mao.0000000000002201","relation":{},"ISSN":["1531-7129","1537-4505"],"issn-type":[{"value":"1531-7129","type":"print"},{"value":"1537-4505","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6]]}}}