{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T16:10:50Z","timestamp":1759939850623},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,6]]},"DOI":"10.1097\/mao.0b013e3182877aee","type":"journal-article","created":{"date-parts":[[2013,4,30]],"date-time":"2013-04-30T12:47:20Z","timestamp":1367326040000},"page":"690-698","source":"Crossref","is-referenced-by-count":8,"title":["A Vibration Investigation of a Flat Surface Contact to Skull Bone for Direct Bone Conduction Transmission in Sheep Skulls In Vivo"],"prefix":"10.1097","volume":"34","author":[{"given":"Hamidreza","family":"Taghavi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bo","family":"H\u00e5kansson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M\u00e5ns","family":"Eeg-Olofsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carina B.","family":"Johansson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anders","family":"Tjellstr\u00f6m","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabine","family":"Reinfeldt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomas","family":"Bergqvist","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joakim","family":"Olsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-17-20210212","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/S0030-6665(20)30567-3","article-title":"The bone-anchored hearing aid compared with conventional hearing aids.","volume":"28","author":"Snik","year":"1995","journal-title":"Otolaryngol Clin North Am"},{"key":"R2-17-20210212","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/S0030-6665(05)70335-2","article-title":"The bone-anchored hearing aids-current status in adults and children.","volume":"34","author":"Tjellstrom","year":"2001","journal-title":"Otolaryngol Clin North Am"},{"key":"R5-17-20210212","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.otohns.2009.12.047","article-title":"The BAHA system in patients with single-sided deafness and contralateral hearing loss.","volume":"142","author":"Wazen","year":"2010","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R6-17-20210212","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1007\/s00405-009-1147-9","article-title":"Pilot study on the effectiveness of the conventional CROS, the Transcranial CROS, and the BAHA transcranial CROS in adults with unilateral inner ear deafness.","volume":"267","author":"Hol","year":"2010","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R7-17-20210212","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1097\/MAO.0b013e3182565b2e","article-title":"Bone-anchored hearing device surgery: a 3- to 6- year follow-up with life table and worst-case scenario calculation.","volume":"33","author":"Tjellstrom","year":"2012","journal-title":"Otol Neurotol"},{"key":"R8-17-20210212","first-page":"21","article-title":"Long-term follow-up with the bone anchored hearing aid: a review of the first 100 patients between 1977 and 1985.","volume":"73","author":"Tjellstrom","year":"1994","journal-title":"ENT J"},{"key":"R9-17-20210212","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/S0194-5998(00)70255-5","article-title":"Evaluation of implant losses and skin reaction around extraoral bone anchored hearing implants: a 0- to 8- year follow-up.","volume":"122","author":"Reyes","year":"2000","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R10-17-20210212","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1016\/j.otc.2006.05.001","article-title":"Revision BAHA surgery.","volume":"39","author":"Battista","year":"2006","journal-title":"Otolaryngol Clin North Am"},{"key":"R11-17-20210212","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.otohns.2005.10.027","article-title":"Perioperative complications with the bone anchored hearing aid.","volume":"134","author":"Shirazi","year":"2006","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R13-17-20210212","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/MAO.0b013e318241c0bf","article-title":"Assessment of more than 1,000 implanted percutaneous bone conduction devices: skin reaction and implant survival.","volume":"33","author":"Dun","year":"2012","journal-title":"Otol Neurotol"},{"key":"R14-17-20210212","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1097\/MAO.0b013e3182267e9c","article-title":"Stability, survival, and tolerability of a novel BAHA implant system: six-month data from multicenter clinical investigation.","volume":"32","author":"Dun","year":"2011","journal-title":"Otol Neurotol"},{"key":"R15-17-20210212","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1177\/000348940911800712","article-title":"Bone-anchored hearing aid surgery in older adults: implant loss and skin reactions.","volume":"118","author":"de Wolf","year":"2009","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R16-17-20210212","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1177\/000348940811701103","article-title":"Nijmegen results with application of a bone-anchored hearing aid in children: simplified surgical technique.","volume":"117","author":"de Wolf","year":"2008","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R17-17-20210212","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1097\/MAO.0b013e3182487fc8","article-title":"Feedback analysis in percutaneous bone-conduction device and bone-conduction implant on a dry cranium.","volume":"33","author":"Taghavi","year":"2012","journal-title":"Otol Neurotol"},{"key":"R18-17-20210212","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1097\/MAO.0b013e31816fdc90","article-title":"Percutaneous versus transcutaneous bone conduction implant system: a feasibility study on a cadaver head.","volume":"29","author":"Hakansson","year":"2008","journal-title":"Otol Neurotol"},{"key":"R19-17-20210212","doi-asserted-by":"crossref","first-page":"203","DOI":"10.3109\/14992020903264462","article-title":"A novel bone conduction implant (BCI): engineering aspects and pre-clinical studies.","volume":"49","author":"Hakansson","year":"2010","journal-title":"Int J Audiol"},{"key":"R22-17-20210212","first-page":"3050","article-title":"Analysis and design of RF power and data link using amplitude modulation of class-E for a novel bone conduction implant. IEEE Trans.","volume":"59","author":"Taghavi","year":"2012","journal-title":"Biomed Eng"},{"key":"R23-17-20210212","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1121\/1.428314","article-title":"Vibration characteristics of bone conducted sound in vitro.","volume":"107","author":"Stenfelt","year":"2000","journal-title":"J Acoust Soc Am"},{"key":"R24-17-20210212","doi-asserted-by":"crossref","first-page":"2373","DOI":"10.1121\/1.2005847","article-title":"Transmission properties of bone conducted sound: measurements in cadaver heads.","volume":"118","author":"Stenfelt","year":"2005","journal-title":"J Acoust Soc Am"},{"key":"R25-17-20210212","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/14992020802311216","article-title":"Transmission of bone conducted sound in the human skull measured by cochlear vibrations.","volume":"47","author":"Eeg-Olofsson","year":"2008","journal-title":"Int J Audiol"},{"key":"R26-17-20210212","doi-asserted-by":"crossref","first-page":"229","DOI":"10.3109\/00016488509104785","article-title":"The bone-anchored hearing aid, principal design and a psychoacoustical evaluation.","volume":"100","author":"Hakansson","year":"1985","journal-title":"Acta Otolaryngol"},{"key":"R29-17-20210212","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1121\/1.1536633","article-title":"The balanced electromagnetic separation transducer: A new bone conduction transducer.","volume":"113","author":"Hakansson","year":"2003","journal-title":"J Acoust Soc Am"},{"key":"R30-17-20210212","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1121\/1.412225","article-title":"Force threshold for hearing by direct bone conduction.","volume":"97","author":"Carlsson","year":"1995","journal-title":"J Acoust Soc Am"},{"key":"R31-17-20210212","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/S0022-460X(87)81349-4","article-title":"Bias errors in mechanical impedance data obtained with impedance heads.","volume":"113","author":"Hakansson","year":"1987","journal-title":"J Sound and Vibration"}],"container-title":["Otology &amp; Neurotology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MAO.0b013e3182877aee","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,14]],"date-time":"2021-05-14T02:06:53Z","timestamp":1620958013000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00129492-201306000-00017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,6]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2013]]}},"URL":"https:\/\/doi.org\/10.1097\/mao.0b013e3182877aee","relation":{},"ISSN":["1531-7129"],"issn-type":[{"value":"1531-7129","type":"print"}],"subject":[],"published":{"date-parts":[[2013,6]]}}}